• 제목/요약/키워드: slab thickness

검색결과 365건 처리시간 0.026초

바닥구조에 따른 바닥충격음 차단성능 현황 (A Status of floor impact sound insulation by the floor structure)

  • 이성호;정갑철;정진연;양관섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.513-517
    • /
    • 2004
  • This study aims to evaluate factors of floor structure influencing to the floor impact sound. For this reasons, we measured the vibration of floor and the floor impact sound in moment flame structure. The main results from this study are that slab area and thickness are critical factors of the floor impact sound and aspect ratio slab is not verified in flor impact sound.

  • PDF

광 스트립 도파로의 등가회로망 해석 (Equivalent network analysis of optical strip waveguides)

  • 이재승
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1989년도 제4회 파동 및 레이저 학술발표회 4th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.225-229
    • /
    • 1989
  • Taking the normal mode transmission direction perpendicular to the substrate, an alternative equivalent network formulation is developed for the analysis of optical strip waveguides. All kinds of mode couplings between the normal modes are included in this formulation. Compared to the previous equivalent network formulations, the calculations are simplified especially when the thickness of the uniform slab is thin enough such that no well guided modes are available along the uniform slab waveguide.

  • PDF

1:10 축척 시험동 구조 모형의 바닥충격 진동 전달 (Propagation of floor impact vibration in a 1:10 scale model of a test structure)

  • 이평직;유승엽;김재호;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1455-1458
    • /
    • 2007
  • Vibration characteristics of concrete slabs were investigated using a 1:10 scale model and finite element method. A 1:10 scale model of a test building with 150 and 200mm slab thicknesses was made of acrylic materials. Modal test was conducted to investigate mode shape and modal frequencies. Results show that the mode shapes of two slabs with different thickness are similar each other, whereas natural frequency is different. Through modal analysis using FEM, it was revealed that both mode shapes and natural frequencies calculated from the FEM model are similar to those of the scale model measurement. It was also found that natural frequencies increased with increment of the slab thickness.

  • PDF

Shear behavior and analytical model of perfobond connectors

  • Zheng, Shuangjie;Liu, Yuqing;Yoda, Teruhiko;Lin, Weiwei
    • Steel and Composite Structures
    • /
    • 제20권1호
    • /
    • pp.71-89
    • /
    • 2016
  • In steel and concrete composite girders, the load transfer between the steel beam and the concrete slab is commonly ensured by installing shear connectors. In this paper, to investigate the nonlinear behavior of perfobond connectors, a total of 60 push-out specimens were fabricated and tested with the variables for the hole diameter, the concrete strength, the thickness of concrete slab, the diameter, strength and existence of perforating rebar, the thickness, height and distance of perfobond ribs. The failure mode and the load-slip behavior of perfobond connectors were obtained. A theoretical model was put forward to express the load-slip relationship. Analytical formulas of shear capacity and peak slip were also proposed considering the interaction between the concrete dowel and the perforating rebar. The calculation results of the proposals agreed well with the experimental values.

고무칩을 이용한 공동주택 바닥구조의 차음성능 향상에 관한 연구 (A Study on the Sound Insulation Performance Elevation of Floor Structure that use Rubber chip in Apartment House)

  • 박명길;함진식
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2002년도 추계학술발표대회
    • /
    • pp.237-332
    • /
    • 2002
  • We constructed ceiling structure and floor structure for elevation of sound insulation performance of concrete slab of apartment house. And, we wished to measure heavy floor impact sound level and light floor impact sound level of these structure. As the result, light floor impact sound level interception performance of concrete slab was measured by thing that construction work of gypsum baud is important. Heavy floor impact sound level interception performance was measured by thing that it is effective that construct to thickness about 30 millimeters on concrete Slav. It was measured effectively that heavy floor impact sound level interception performance constructs rubber chip to thickness about 30 millimeters on concrete Slav.

  • PDF

표준실험동의 구조별 소음 진동 특성 (Noise and Vibration Characteristics of Construction structures in Standard Laboratory)

  • 정영;유승엽;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.390-393
    • /
    • 2005
  • In this study, examined heavy-weight floor impact sound to rahmen structure(steel reinforced concrete structure) and bearing-wall structure(box frame type structure) that have slab thickness of 4 form at a standard laboratory through noise and vibration measured. The results of ANSYS modeling of structures was predicted that the nature natural frequency increased according to change of thickness of each slab by finite element analysis, and acceleration value decreased. Rahmen structures compares with bearing-wall structure, nature frequency was predicted low. Measurement results of natural frequency and acceleration level for structures at a standard laboratory, tendency department such as ANSYS modeling appeared. Rahmen structures appeared that reduction effect is less in Acceleration level and heavy impact sound transmission level comparing with bearing-wall structure.

  • PDF

현장실험을 통한 바닥충격음 저감공법의 성능평가 및 중량충격음 저감 방안 (A Evaluation Study on Reduction Method of Floor Impact Noise through Field Test and the Effective Method for Heavy Impact Noise)

  • 이병권;배상환;홍천화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.451-456
    • /
    • 2004
  • In this study, evaluation was carried out for reduction method of floor impact noise through field test and the effective methods for heavy impact noise were proposed. As a field test, impact noise reduction materials such as EPP, EEPS, EVA, PE and so on, did not satisfied the recommandation value at the condition of 150mm thickness concrete slab. The evaluation results for those materials by 'inverse A curve' showed $53\sim55dB$ at heavy impact noise and $53\sim58dB$ at light impact noise. But, two methods proposed by authors were evaluated $47\sim50dB$ at heavy Impact noise and $54\sim58dB$ at light Impact noise on the similar concrete slab thickness.

  • PDF

기둥으로 지지된 슬래브교(橋)의 모멘트 산정(算定)에 관한 연구(硏究) (Simplified Bending Moment Analysis in Slab Bridges supported by Column Type Piers)

  • 김영인;이채규;김우
    • 대한토목학회논문집
    • /
    • 제12권3호
    • /
    • pp.17-24
    • /
    • 1992
  • 철근(鐵筋)콘크리트 슬래브교(橋) 설계시(設計時) 교각(橋脚)을 T형 및 ${\Pi}$형식으로 취하는 것보다 기둥만으로 슬래브를 직접 지지(支持)하도록 함으로써 유효공간(有效空間) 확보 뿐만 아니라 슬래브 자체(自體)의 내하력(耐荷力)을 이용함으로써 구조적(構造的)인 효율측면(效率側面)에도 유리하다. 그러나 기둥으로 지지된 슬래브교의 설계를 위한 휨모멘트계산은 아직 체계화(體系化)되어 있지 않은 상태이다. 중간지지점(中間支持點)의 종방향(縱方向) 최대휨모멘트를 유효폭개념(有效幅槪念)을 적용하여 가상지간(假像支間)을 이용한 단순보해석으로 간단히 구할 수 있는 방법(方法)에 대하여 연구하고 유효폭을 수식화(數式化)하였다. 주요변수(主要變數)는 지간(支間), 교폭(橋幅), 슬래브 두께 및 기둥단면(斷面)으로 하고 유한요소법(有限要素法)을 이용하여 단면력(斷面力)의 변화를 조사하였다.

  • PDF

일방향 중공슬래브의 휨강도 산정방법에 관한 연구 (A Study on the Calculation Method for Flexural Strength of One-way Hollow Slabs)

  • 김현수;임준호;강주원
    • 한국전산구조공학회논문집
    • /
    • 제25권6호
    • /
    • pp.541-548
    • /
    • 2012
  • 중공슬래브 시스템은 슬래브 두께가 증가해도 자중은 크게 증가하지 않고, 일반슬래브에 비해서 휨성능이 크게 저하되지 않는 장점이 있다. 이러한 경제적인 건물 설계 및 친환경 구조물 구현을 가능하게 하는 시스템에도 불구하고 중공슬래브의 활용도는 현재로서는 낮다고 할 수 있다. 특히 국내의 건축분야에 있어서는 매우 낮은 편이다. 이러한 현 상황의 가장 큰 이유는 중공슬래브의 적용을 위한 구조 해석 및 설계방법이 일반화되어 있지 않다는 것이다. 본 연구에서는 실질적인 압축영역을 고려하기 위해 가정한 중공 단면형상에서 중립축 위치에 따른 압축응력블럭의 체적으로 휨강도 산정식을 제시하였다. 기존 중공부 상부만을 압축영역으로 고려한 휨강도 산정방법은 가장 보수적인 방법으로 판단되며 2개의 대체단면을 설정하여 휨내력을 산정하는 것이 더 실질적인 방법으로 판단된다.

지반위에 놓인 콘크리트 슬래브의 수직하중에 대한 슬래브 하부의 수평 저항의 영향 분석 (Effect of Horizontal Resistance at Slab Bottom on Behavior of Concrete Slabs-on-Grade under Vertical Loads)

  • 심재수;김성민
    • 한국도로학회논문집
    • /
    • 제7권4호
    • /
    • pp.141-150
    • /
    • 2005
  • 지반위에 놓인 콘크리트 슬래브가 수직 하중을 받을 때 지반의 전단저항과 슬래브 하부와 지반과의 마찰 등에 의해 생기는 슬래브 하부의 수평저항을 고려하여 지반위에 놓인 콘크리트 슬래브의 거동을 분석하였다. 슬래브 하부의 수평 저항을 고려하기 위한 해석 공식을 유도하였고 퓨리에변환을 이용한 변환영역에서 이러한 공식의 해를 구하였다. 또한 판요소와 쉘요소를 이용한 유한요소법에 의한 모델을 개발하여 수치 해석 결과도 도출하였다. 이러한 해석 공식과 수치해석 모델을 이용한 해석 결과를 비교 분석하였고 매우 비슷한 결과가 도출되는 것을 알 수 있었다. 콘크리트 슬래브의 응력 분포에 슬래브 하부의 수평저항이 미치는 민감성을 여러 가지의 다른 슬래브의 두께, 탄성계수, 그리고 지반의 수직탄성계수 등을 고려하여 분석하였다. 해석 결과에서 슬래브 하부의 수평 저항은 슬래브의 응력에 매우 큰 영향을 미칠 수 있다는 것을 발견하였다.

  • PDF