Noise and Vibration Characteristics of Construction structures in Standard Laboratory

표준실험동의 구조별 소음 진동 특성

  • 정영 (한양대학교 건축공학과) ;
  • 유승엽 (한양대학교 건축공학과) ;
  • 전진용 (한양대학교 건축공학부)
  • Published : 2005.11.01

Abstract

In this study, examined heavy-weight floor impact sound to rahmen structure(steel reinforced concrete structure) and bearing-wall structure(box frame type structure) that have slab thickness of 4 form at a standard laboratory through noise and vibration measured. The results of ANSYS modeling of structures was predicted that the nature natural frequency increased according to change of thickness of each slab by finite element analysis, and acceleration value decreased. Rahmen structures compares with bearing-wall structure, nature frequency was predicted low. Measurement results of natural frequency and acceleration level for structures at a standard laboratory, tendency department such as ANSYS modeling appeared. Rahmen structures appeared that reduction effect is less in Acceleration level and heavy impact sound transmission level comparing with bearing-wall structure.

Keywords