• Title/Summary/Keyword: slab structure

Search Result 593, Processing Time 0.026 seconds

Dynamic Analysis of Space Frameworks on the Elastic soil (탄성 지반상에 놓인 3차원 골조구조물의 동적해석)

  • 장병순;서상근
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1996.10a
    • /
    • pp.37-44
    • /
    • 1996
  • When a load such as the mechanical load, the wind load, and the seismic load causing a vibration, acts on the body of the 3-D frameworks with slab, it is required to consider the dynamic behavior of elastic soil as well as that of 3-D structure in the structural analysis. Thus, this study presents the analysis of dynamic behavior using finite element method that is formulated by using a model of the 3-D structure. For the idealization of the actual structure closely into a geometric shape, plate is subdivided into 4-node plate element with the flexibility, beam-column is subdivided into 2-node beam element, and elastic soil is subdivided into 8-node brick element.

  • PDF

A Study on Early Strength Estimation of Precast Concrete joint Mortar with Microwave (마이크로파에 의한 PC접합모르타르의 조기강도추정에 관한 연구)

  • 원준연;박일용;백민수;이종균;안형준;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.217-222
    • /
    • 2000
  • A large Pc structure building is system that consisted of bearing wall and slab joint. It has general structure stability from unity thar each members tied at joint. The strength of mortar that packing in joint among panels is important to internal force in entire building system. Do, if we could get early strength estimation with microwave. It would bring good construction planning, reduce construction time, and judge building stability and so on. The purpose of this study is to develop early estimation method for making better quality control and constructing good PC panel structure. The results of this study were as follows :1) With sealed molds, reduced moisture volatilization to more than 60% and enlarged 30% accelerated compressive strength than before one. 2) To get more accelerated strength, we should control maximum temperature difference to $30^{\circ}C$ downward 3)Interrelation with 7-day and 28-day strength were 0.831,0.902, and it is above than before one

  • PDF

Analysis of 3D wall building structures dynamic response

  • Chyzy, T.;Kretowska, J.;Miedzialowski, Cz.
    • Structural Engineering and Mechanics
    • /
    • v.22 no.1
    • /
    • pp.33-52
    • /
    • 2006
  • Three-dimensional description of building structure taking into consideration soil-structure interaction is a very complex problem and solution of this problem is often obtained by using finite element method. However, this method takes a significant amount of computational time and memory. Therefore, an efficient computational model based on subdivision of the structure into building elements such as wall and floor slab elements, plane and three-dimensional joints and lintels, that could provide accurate results with significantly reduced computational time, is proposed in this study for the analysis three-dimensional structures subjected to dynamic load. The examples prove the efficiency and the computing possibilities of the model.

A study on the shallow tunneling method using cover structure (복개 구조물을 이용한 저토피 계곡부 터널의 통과방안에 대한 연구)

  • Chung, Yong-Jin;Nam, Hyun-Woo;Choi, Ho-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.564-569
    • /
    • 2005
  • Usually, Steel pipe grouting method or cut and cover method has been applied to tunnel with very shallow overburden or it is situated in valley. However, in case of lack of overburden height to reinforcement tunnel crown which is very difficult to construction. Also, application of cut and cover method that do not consider surrounding site condition causes popular enmity generation and environmental damage. It is the best alternative method that reduces the amount of excavated soil and excavate tunnel under ground to solve these problems. The tunneling method using cover structure which is to prevent a tunnel from collapse because this method can be reduce excavation area and construct tunnel under ground after set a cover structure and backfill ground. In this study, to know more effective structure type, comparative analysis was performed to behavior characters of slab and arch type construction that can be used to cover structure. Also a 2D and 3D numerical analysis have been performed to verify the stability of ground during excavation. As the result, the tunneling method using cover structure that it can be good alternative method for tunnel with shallow overburden and it through valley

  • PDF

System dentification of Apartment Buildings with Wall-Slab configuration using Modal Analysis (모드해석을 통한 벽식구조 아파트건물의 System Identification)

  • 장극관;천영수
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.191-197
    • /
    • 1998
  • This paper described the dynamic characteristics of 20-story apartment buildings from the results of full-scale measurements and analysis. The natural frequencies and mode shapes are quantified by measuring and analyzing ambient vibrations of the structure and compared with the results from dynamic analysis. Comparison with computed mode shapes and frequencies shows good agreement with the experimental results. It proved that it is important to estimate coupling beam and soil parameters through a comparison of the measured results with calculated results.

  • PDF

Polarization-independent Bragg blazing and Simultaneous Bragg and off-Bragg Blazing in a Periodic Strip Grating Structure over a Grounded Dielectric Slab (접지된 유전채 슬랩 위에 스트립 격자구조에서 입사피의 편파에 무관한 Bragg Blazing 현상과 Bradd 및 off-Bragg Blazing 현상)

  • 조웅희;조영기
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.2
    • /
    • pp.193-198
    • /
    • 2001
  • 접지된 유전체슬랩 위에 주기적으로 스트립이 놓여있는 격자구조에 대한 전자파 산란현상을 반사격자(reflection grating) 관점과 누설파안테나(leaky wave antenna) 관점에서 조사하였다. 수치해석 결과로 입사파의 편파에 무관한 Bragg blazing 현실과 동시에 Bragg 및 off-Bragg blazing 현상이 확인되는 경우를 조사하였으며 그 특성(복소전파상수, 복사패턴, 산란특성)에 대하여 논의하였다.

  • PDF

A Safety Evaluation of Cable Tunnel Exposed to Fire (화재피해 통신구의 안전진단)

  • 김지상;김형우;김효환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.04a
    • /
    • pp.221-226
    • /
    • 1994
  • A safety evaluation of cable tunnel, which is a concrete box structure with telecommunication facilities in it, exposed to fire is given. The immediate field observation was performed to find out any sign of sudden structural failure. In some region, where the fire intensity was heavy, the spalling of concrete cover in upper slab occurred. Next, more careful investigation was done with proper non-desturctive testing methods and structural analysis taking into account the changes in material properties due to fire. It seems that there is no severe damage on concrete, reinforcements and over all structural system.

  • PDF

Design of Reinforced Concrete Members for Serviceability Based on Utility Theory

  • Lee, Young Hak;Kim, Sang Bum
    • Architectural research
    • /
    • v.7 no.2
    • /
    • pp.61-68
    • /
    • 2005
  • A methodology for design of reinforced concrete members for serviceability in general and deflection control in particular is presented based on application of utility theory. The approach is based on minimizing total cost including both initial construction and cost of failure considering variability in structural behavior and various forms of serviceability loss function. The method is demonstrated for the case of a simply supported slab for example.

The application study on the super flowing the polymer based cement mortar (초유동화 폴리머시멘트몰탈의 실용화연구)

  • 손형호;이종열
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.36-41
    • /
    • 1995
  • Recently, as the problems according to the deteriorated structure were gathering sterength, there were required the advent of the high peformance for polymer ceme at compostie in building constrution devision. The polymer cement mortar was developed for improvements of the various problems in ordinary cement mortar. finishing method using the super flowing polymer-based self levelling mortar for concrete slab and floor.

  • PDF

Study for surface wave launcher of dielectric coated coaxial cable using FDTD method (FDTD 방법을 이용한 유전체를 입힌 동축 케이블의 표면파 로운처에 관한 연구)

  • 정진우;이창원김중표손현
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.173-176
    • /
    • 1998
  • The surface wave launcher from the dielectric coated coaxial cable to dielectric slab is investigated. FDTD method using local subcell and contour-path model is applied to determine the fine geometrical features. The reflection coefficient in coaxial cable region is found using extract algorithm. In this paper, two structures are presented as coaxial slot surface wave launcher. One structure has a vertical launching angle, and the other has an arbitrary launching angle. The numerical results show that a certain launching angle is minimized the reflection coefficient.

  • PDF