• 제목/요약/키워드: size difference

Search Result 5,036, Processing Time 0.075 seconds

The Analysis of Lower-Trunk Sizes and Ease of Pants Patterns for Elementary Boys -Focus on Tall and Plump Boys- (학령기남아 바지패턴설계를 위한 체간하부치수 및 가상치수맞음새 분석 -큰키아동 및 비만아동을 중심으로)

  • Kang, Yeo-Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.1
    • /
    • pp.153-166
    • /
    • 2010
  • The study analyzes the lower-trunk sizes of 7-12 year old elementary school boys and compares sizes with boys, juniors, and men for analyzing and image fit. For the study, the data of SizeKorea (2004) was analyzed. Waist, hip, and the ratio of hip-thickness to hip-width were significantly different between age groups as well as between boys, juniors, and men. In the same height group, over 145cm boys had bigger waist than juniors and smaller waists than men. Therefore, the difference of waist size and the length of leg could cause the dissatisfaction of the pant fit when tall and plump boys chose a corresponding pants size to individual height or waist. The hip-thickness of body and pants patterns were compared in the analysis of the ease of hip-thickness. Tall and plump boys will feel discomfort in the crotch area because of the insufficiency of the hip-thickness of pants. Therefore, the amount of crotch extension of individual pants should be calculated by hip size instead of using the fixed amount. The reference sizes for discriminative pants for tall and plump boys were analyzed for a better fit.

Size Distribution and Source Identification of Airborne Particulate Matter and Metallic Elements in a Typical Industrial City

  • Ny, Mai Tra;Lee, Byeong-Kyu
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.1
    • /
    • pp.9-19
    • /
    • 2010
  • The size distribution of airborne particulate matter (PM) and the concentrations of associated metallic elements were investigated in a busy urban region of a typical Korean industrial city. The PM concentrations measured during the spring, except for those in the size range of 1.1 to 2.1 ${\mu}m$, were slightly higher than the PM concentrations in the summer. Coarse particles contributed greatly to the variation in PM concentrations in the spring, while fine and submicron particles contributed largely to the variation in PM concentrations in the summer. The difference in size modes of the PM concentrations between spring and summer may be explained by the Asian dust effect and its accompanying wind direction and speed. Extremely high enrichment factors (EFs) values (6,971 to 60,966) for all of the size distributions in PM were identified for cadmium (Cd). High EFs values (12 to 907) were also identified for other heavy metals including Cr, Cu, Ni, Pb, Zn and Mn. Low EF values (0.29 to 8.61) were identified for Ca, K, Mg and Na. These results support the common hypothesis that most heavy metals in ambient PM have anthropogenic sources and most light metals have crustal sources. The results of principal components analyses and cluster analyses for heavy metals indicate that the principal sources of PM and metals were emissions from non-ferrous metal smelters, oil combustion, incinerators, vehicular traffic and road dust.

Developmental characterization of embryo size mutant in rice (Oryza sativa L.)

  • Hong, Soon-Kwan
    • Plant Resources
    • /
    • v.5 no.2
    • /
    • pp.141-154
    • /
    • 2002
  • In this experiment, three kinds of mutations(ge, re, and eml )relating to the size of embryos were used to study their generation, genetic mechanism and developmental characteristics, and the interactions between embryo and endosperm were also examined. Giant embryo mutation comprises 7 kinds including the already isolated ge, and ge-2, which share an identical gene site. The SAM and the size of radicule for the ge showed little difference compared to a normal type. The number of embryo cells did not increased as much as it would affect the size of embryo. Therefore, the enlargement of embryo was due to the enlargement of scutellum that originated from the corpulence of each cell. Both F$_1$' s of re ]and odm 49 formed reduce embryos, and other combinations of hybridization showed all wild type of embryo sizes. Accordingly, the odm 49 must have an identical gene site of re 1, while odm 48 and odm 62 have different gene sites. Their shoots and radicules also shrank by the same ratio, however no sign of physical change was noticed. The size of embryo cell showed no change, while the number of cells was the half of that of wild types. The three gene sites of re represent all of them control the size of the entire embryo forming organs. The eml 1 was defined to have temperature sensibilities that the generation of endosperms was active at a high temperature while that was hampered at a low temperature.

  • PDF

A Study on the Dose Distribution of Various Field and Penumbra Shield in the Telecobalt-60 (코발트-60의 조사야(照射野) 변형(變形) 및 반음영(半陰影) 차폐(遮蔽)효과에 따른 선량분포(線量分布)에 관한 연구(硏究))

  • Kim, Young-Il;Lee, Hye-Kyong
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.71-72
    • /
    • 1985
  • This study was performed on the dose distribution of various field size and the effect of penumbra shield in the telecobalt unit. The results obtained are as follows. 1. Errors of the light and ${\gamma}-ray$ field size was below the regulation as 0.52 percentage. 2. The coefficient of field area was increased with the larger field area, and this coefficient was showed the more difference in larger SSD. 3. The rectangular field areas, which were described by level of the same percentage depth does, were decreased with the more elongation factor. At the same elongation factor, the compensating factor was decreased with the larger field size. 4. The lead block or extension collimator was able to shield r-ray exposure of outside field size from 50 to 80 percentage. 5. On the matching adjacent fields, while the gap between beam edges are contacted, that overlapped beam edges indicated up to 140 percentage, and while the gap was 1 cm, it could be reduced to 90 Percentage. The lead-libocking on the overlapped area was more effective to lower dose, as 80 percentage in this case. 6. Percentage depth dose of various trimming field sizes were increased linearlly according to area 1 perimeter size, but the center split field size did not maintain linearlly.

  • PDF

RELATIONSHIP BETWEEN PARTICLE POOL SIZE IN THE RETICULO-RUMEN AND CHEWING TIME IN SHEEP

  • Okamoto, Masahiro;Miyazaki, H.;Oura, R.;Sekine, J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.3 no.3
    • /
    • pp.225-229
    • /
    • 1990
  • Sixteen mature sheep were fed chaffed orchardgrass hay once a day. Jaw movement of the sheep was recorded for 24 hours before slaughter. Four sheep were slaughtered either prior to eating, 2, 8 or 16 hours after the commencement of eating to measure digesta pool size and particle size distribution in the reticulo-rumen. Eating time was restricted to 120 minutes. Rumination time and actual chewing time during rumination increased with time after the meal. Mean dry matter (DM) pool size before and 2 hours after the meal were 1.36 and 2.45 times of DM intake, respectively. The proportion of large particle (>1.18 mm; LP) in the DM ingested during the meal was caculated to be about 70%. The mean DM and LP pool sizes per DM intake and the mean proportion of LP in the DM pool decreased with time after the meal. There were close negative relationships between either DM or LP pool sizes per DM intake and the chewing activities either expressed as time spent rumination, actual chewing time during rumination or total actual chewing time(total of eating time and actual chewing time during rumination). The difference between DM intake and LP pool size were assumed to be LP degradation in the present experiment, and correlated positively with the chewing activities. A large proportion of the digesta load was comprised of small particles, in excess of the daily intake.

The Classification of Elderly Men's Feet - With the Three-dimensional Body Scanner Data of Size Korea - (노년 남성의 발 유형 분류 -Size Korea의 3차원 측정 데이터를 이용하여-)

  • Seok, Hye-Jung;Park, Ji-Eun
    • Journal of the Korean Society of Costume
    • /
    • v.57 no.10
    • /
    • pp.50-59
    • /
    • 2007
  • This study has been conducted to classify elderly men's feet with the three-dimensional body scanner data of Size Korea. It was intended to assist the manufacturing of the shoes that can appropriately perform the functions of feet, by providing the specific information about the shapes of elderly men's feet that are altered as a result of aging and shoe-wearing for a long time. The findings are as follows. 1. The investigations into the average and standard deviation of the measurements and index values for the elderly men's feet showed a large personal difference in the items of length and circumference. 2. The factors constituting the elderly men's feet were observed to be the size of foot width(Factor 1), the central angle of feet and the extension of toes(Factor 2), the size of ankle(Factor 3), the positions of lateral malleolus and pternion(Factor 4), and the position and size of medial malleolus(Factor 5). 3. The cluster analysis for the classification of elderly men's feet produced three types of them.

Study on a Full-Size Tester for Manual Transmision Clutches (수동변속기용 클러치의 관성시험장치에 관한 연구)

  • 이병수;신현명;허만대
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.4
    • /
    • pp.101-109
    • /
    • 2004
  • Three models with various degree-of-freedom for a manual transmission clutch full-size tester have been developed and the models' reliability and accuracy have been verified using the measured data. A simulation study has also been conducted to understand dynamic behavior of the tester. The model for this simulation study includes clutch disk friction and damper dynamics. The developed model is very accurate in terms of maximum torque exerted on the clutch, slip duration and the vibration response except a slight difference compared to the measured data. In a history graph of the clutch torque, the maximum torque response from simulation is flat but the measured is sunken with a noticeable curvature. This phenomenon is found to be irrelevant to the dynamics of the full-size tester but is originated from the characteristics of the clutch itself. Thus, the full-size tester has been proven to be a reliable tester for clutch's power and torque transmission capability. To obtain a better understanding of clutch's characteristics and relationship between full-size tester and other testing methodologies, future research directions have been suggested.

A study on the bycatches by mesh size of spring-net-pot in Geo-je & Tong-young waters of Korea (거제·통영해역 스프링그물통발의 망목별 혼획 연구)

  • Cha, Bong-Jin;Cho, Sam-Kwang;Lee, Gun-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.3
    • /
    • pp.204-213
    • /
    • 2010
  • Test fishing was carried out using six kinds of different mesh sizes (20, 22, 24, 28, 35, 40mm) for springnet-pot to study bycatches according to the mesh size and catches survey was done for another one (mesh size : 22mm, entrance round : 350mm) in Geo-je & Tong-young waters of Korea. On the first sea experiment, it was thought that suitable mesh size of spring-net-pot catching conger-eel over 35cm with decreasing the catches of conger-eel (Conger myriaster) below 35cm was 24mm. On the second sea experiment, commercial catches were crabs (Charybdis bimaculata), octopus minor (Octopus variabilis) and others including conger-eel, and catches proportion was 60% of total catches weights. There was no big difference for the monthly catches. Self-consumption catches were 9 species including conger-eel below 35cm holding 50% of catches in the side of weights. There were 40% of bycatches for the catches weights and 63% for catches numbers in the 22mm mesh size of spring-net-pot having entrance round over 140mm. It showed that 50% of catches weights were discarded.

An experimental study on search speed and error rate according to Korean letter size and font on search task with VDT (VDT 화면에서 한글의 글자크기와 서체에 따른 탐색속도와 오류율에 관한 실험적 연구)

  • 황우상;이동춘;이상도;이진호
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.29-38
    • /
    • 1997
  • The research on the factors which effect on legibility is mainly utilized as the basic data of selecting the standard guideline of VDT screen. But the research on Korean is scarcer than that of English. Furthermore, it is unreasonable to apply the results of the foreign language to Korean, beause of the difference between the typography of English and that of Korean. Therefore, more systematic and ergonomic research of the Korean typography on VDT screen is needed. In this paper, an experimental study on search speed and error rate is designed and performed according to different Korean letter size and font on search task with VDT. The experimental screen based on popular Ming and Gothic style is made up of total 12 artificial screens, each 6 different font size. As the criteria of the performance, searching speed(s.s.) and error rate (e) are selected, and CFF value is measured to evaluate user's visual fatigue. The results of experiment in font show that the Korean Gothic style is superior to the Korean Ming style in user's visual performance. The letter size that gives user the optimal performance ranges from the visual angle 39.8' to 55.5' in Ming style, from the visual angle 39.8' to 52.6' in Gothic systle. In visual fatigue experiment, the better performance of letter size is, the less tired user feels. And the smaller letter size is, the more tired user feels. There is no relationship between font and user's visual fatigue.

  • PDF

The effects of non-uniform droplets distribution on the characteristics of group combustion for liquid fuel droplets cloud (비균일 액적분포가 액적군의 집단연소 특성에 미치는 영향)

  • 김호영;전철균
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.3
    • /
    • pp.479-487
    • /
    • 1987
  • In order to predict the effects of droplets distributions such as number density and droplets size on group combustion characteristics and flame structure for liquid fuel sprays, modifications of group combustions model were made by changing the droplets distributions from uniform to non-uniform. Various droplets distribution models were adopted in this analysis to examine the effect of number density distribution on combustion characteristics and the difference between uniform and non-uniform droplets size distributions for a spherical droplets cloud. As results of present study, hollow droplets could with outer concentrating distribution has shorter total combustion time compare with the case of solid droplets cloud with inner concentrating distribution. Uniform droplets size distribution model predicts the shorter total combustion time compare with non-uniform droplets size distribution model, and the uniform droplets size distribution model may be used to predict the total combustion time for the droplets cloud containing larger initial size of droplets.