• Title/Summary/Keyword: size difference

Search Result 5,011, Processing Time 0.033 seconds

Basic Research for the Tactual User Interface Design (촉각적 사용자 인터페이스 디자인에 관한 기초 연구 -소형 원형 버튼의 크기 판별을 중심으로-)

  • Yang, Seung-Mu;Jeong, Byung-Yong
    • IE interfaces
    • /
    • v.13 no.2
    • /
    • pp.253-257
    • /
    • 2000
  • This study was conducted to test the significance of differences in the tactual difference thresholds and perception time for tactual direction type and finger type and radius size based on small circular button. The results show that difference threshold of vertical tactual perception is significantly greater than horizontal perception, but there are no significant differences in difference thresholds among finger types and radius sizes. Also, there are no significant differences in tactual perception time among tactual direction types, finger types, and radius types. These findings are applicable for tactual user interface design.

  • PDF

Comparison of Activity Capacity Change and GFR Value Change According to Matrix Size during 99mTc-DTPA Renal Dynamic Scan (99mTc-DTPA 신장 동적 검사(Renal Dynamic Scan) 시 동위원소 용량 변화와 Matrix Size 변경에 따른 사구체 여과율(Glomerular Filtration Rate, GFR) 수치 변화 비교)

  • Kim, Hyeon;Do, Yong-Ho;Kim, Jae-Il;Choi, Hyeon-Jun;Woo, Jae-Ryong;Bak, Chan-Rok;Ha, Tae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.27-32
    • /
    • 2020
  • Purpose Glomerular Filtration Rate(GFR) is an important indicator for evaluating renal function and monitoring the progress of renal disease. Currently, the method of measuring GFR in clinical trials by using serum creatinine value and 99mTc-DTPA(diethylenetriamine pentaacetic acid) renal dynamic scan is still useful. After the Gates method of formula was announced, when 99mTc-DTPA Renal dynamic scan is taken, it is applied the GFR is measured using a gamma camera. The purpose of this paper is to measure the GFR by applying the Gates method of formula. It is according to effect activity and matrix size that is related in the GFR. Materials and Methods Data from 5 adult patients (patient age = 62 ± 5, 3 males, 2 females) who had been examined 99mTc-DTPA Renal dynamic scan were analyzed. A dynamic image was obtained for 21 minutes after instantaneous injection of 99mTc-DTPA 15 mCi into the patient's vein. To evaluate the glomerular filtration rate according to changes in activity and matrix size, total counts were measured after setting regions of interest in both kidneys and tissues in 2-3 minutes. The distance from detector to the table was maintained at 30cm, and the capacity of the pre-syringe (PR) was set to 15, 20, 25, 30 mCi, and each the capacity of post-syringe (PO) was 1, 5, 10, 15 mCi is set to evaluate the activity change. And then, each matrix size was changed to 32 × 32, 64 × 64, 128 × 128, 256 × 256, 512 × 512, and 1024 × 1024 to compare and to evaluate the values. Results As the activity increased in matrix size, the difference in GFR gradually decreased from 52.95% at the maximum to 16.67% at the minimum. The GFR value according to the change of matrix size was similar to 2.4%, 0.2%, 0.2% of difference when changing from 128 to 256, 256 to 512, and 512 to 1024, but 54.3% of difference when changing from 32 to 64 and 39.43% of difference when changing from 64 to 128. Finally, based on the presently used protocol, 256 × 256, PR 15 mCi and PO 1 mCi, the GFR value was the largest difference with 82% in PR 15 mCi and PO 1 mCi. conditions, and at the least difference is 0.2% in the conditions of PR 30 mCi and PO 15 mCi. Conclusion Through this paper, it was confirmed that when measuring the GFR using the gate method in the 99mTc-DTPA renal dynamic scan. The GFR was affected by activity and matrix size changes. Therefore, it is considered that when taking the 99mTc-DTPA renal dynamic scan, is should be careful by applying appropriate parameters when calculating GFR in the every hospital.

NUMERICAL ANALYSIS FOR FLOW CHARACTERISTICS WITH GEOMETRIC SHAPE AND CONTROL CONDITIONS IN SUBSEA BY-PASS VALVE (심해저 바이패스 밸브의 기하학적 형상과 제어조건에 따른 유동특성에 관한 수치해석적 연구)

  • Lee, J.H.;Min, C.H.;Oh, J.W.;Cho, S.;Kim, H.W.
    • Journal of computational fluids engineering
    • /
    • v.21 no.2
    • /
    • pp.99-105
    • /
    • 2016
  • The present study has been carried out to analyze the flow characteristics with geometric shape and control conditions in subsea by-pass valve. The function of by-pass valve is to prevent reverse flow. In this study, the static analysis has been perform for analyzing fluid flow in open state. In order to consider the turbulent effect, the standard ${\kappa}-{\varepsilon}$ model was used. A variety of parametric studies, such as by-pass valve type or size, volume flow rate, leakage hole size, leakage hole position, block type, block shape, were performed. The pressure difference across the valve in the model broadened the flow channel cross-sectional area was greater than the base model for the same operating conditions. As the pipe diameter in the block decreases the pressure difference is greatly increased. The pressure difference according to block shape such as edge type and round was almost negligible. For the same Reynolds number the pressure difference was little changed according to the size of the valve.

The Study about Correlations of Heart Sizes in Patients with Anxiety Disorder (불안장애로 진단된 환자의 심(心) 대소(大小) 관련성에 관한 연구)

  • Jung, Chan-Su;Gug, Yun-Jai;Choi, Sung-Youl;Kang, Hyung-Won;Lyu, Yeoung-Su;Kim, Tae-Heon
    • Journal of Oriental Neuropsychiatry
    • /
    • v.16 no.2
    • /
    • pp.35-42
    • /
    • 2005
  • Objective : The relations of the heart size and seven emotions were described in Dong Yi Bo Gam, and we aimed to identify the correlations of the patients with anxiety disorder and their heart sizes. Methods : The subjects were 15 patients with anxiety disorder and 20 control groups. Chest radiography were performed. We measured patients' heart sizes and compared with control groups. Results : 1. The signigicant difference of somatization, anxiety, depression scale and Panic anxiety scale in SCL-90-R in patients with anxiety disorder from controls was confirmed. 2. The difference of thoracic sizes in patients with anxiety disorder and controls had no correlations. 3. The difference of heart sizes in patients with anxiety disorder and controls had no correlations. 4. The difference of cardiothoracic ratio in patients with anxiety disorder and controls had negative correlations. Conclusions : Based on these results, the patients with anxiety disorders and their heart sizes had no correlations. But in cardiothoracic ratio had negative correlations. So heart size and seven emotions have significant correlation.

  • PDF

Sample size determination in dental research (치의학 연구에서의 표본크기 산출)

  • Lim, Hoi-Jeong
    • The Journal of the Korean dental association
    • /
    • v.52 no.9
    • /
    • pp.558-569
    • /
    • 2014
  • Sample size determination is critical, but not easy to do. Sample size defined as the number of observations in a sample to be studied should be big enough to have a high likelihood of detecting a true difference between groups. Practical procedure for determining sample size, using $G^*$power and previous dental articles, was shown in this study. Examples involving independent t-test, paired t-test, one-way analysis of variance(ANOVA), and one-way repeated-measures(RM) ANOVA were used. The purpose of this study is to enable researchers with non-statistical backgrounds to use in practice freely available statistical software G*power to determine sample size and power.

A Study on the Apparel Sizing for Children′s Upper Garment (아동 기성복 상의 치수규격에 관한 연구)

  • 윤정혜;조윤주;박정순
    • The Research Journal of the Costume Culture
    • /
    • v.3 no.2
    • /
    • pp.307-321
    • /
    • 1995
  • The purpose of this study is to make the size chart of the child's ready-made upper garnet. For his study, we used the 1992 national anthropometric database. The results obtained are as follows. (1) It is known that the bust girth-based size chart is better than the age-based one. (2) The size range of the bust girth was 55∼73 cm to the size of the child's upper garment, and the number of the size was 7. Then the cover-rate was 86%. (3) In this study, the unisex chart was newly made because it was hardly difficult to find the actual size difference between boys and girls.

  • PDF

Particle size distributions and concentrations above radiators in indoor environments: Exploratory results from Xi'an, China

  • Chen, Xi;Li, Angui
    • Environmental Engineering Research
    • /
    • v.20 no.3
    • /
    • pp.237-245
    • /
    • 2015
  • Particulate matter in indoor environments has caused public concerns in recent years. The objective of this research is to explore the influence of radiators on particle size distributions and concentrations. The particle size distributions as well as concentrations above radiators and in the adjacent indoor air are monitored in forty-two indoor environments in Xi'an, China. The temperatures, relative humidity and air velocities are also measured. The particle size distributions above radiators at ten locations are analyzed. The results show that the functional difference of indoor environments has little impact on the particle size distributions above radiators. Then the effects of the environmental parameters (particle concentrations in the adjacent indoor air, temperatures, relative humidities and air velocities) on particle concentrations above radiators are assessed by applying multiple linear regression analysis. Three multiple linear regression models are established to predict the concentrations of $PM_{10}$, $PM_{2.5}$ and $PM_1$ above radiators.

The Preparation of Polyurethane Microcapsule and Its Breaking Behavior (폴리우레탄계 마이크로캡슐의 제조 및 그의 파괴 거동)

  • 박형인;김애경;이웅의;최창남
    • Textile Coloration and Finishing
    • /
    • v.10 no.2
    • /
    • pp.37-44
    • /
    • 1998
  • In this study, the polyurethane microcapsules containing disperse dye were prepared by in-situ polymerization method using hexamethylene diisocyanate (HDI, aliphatic type) and m-xylene diisocyanate(XDI, aromatic type) with ethylene glycol (EG) And the size, shape, particle size distribution, and breaking behavior of microcapsules prepared were investigated. The size and shape of microcapsule were observed by scanning electron microscope (SEM) . The particle size distribution was analyzed by image analyzer. The breaking behavior of microcapsule was checked by measuring the optical density of solution that the disperse dye was dissolved after the microcapsule was broken by constant pressure. The particle size was inversely proportional to the stirring speed, and the size of microcapsule prepared from HDI and EG was smaller than that of microcapsule prepared from XDI and EG. Aliphatic type microcapsule was broken easily, compared with aromatic type one. It was considered due to the difference of reactivity between HDI and XDI. And the microcapsule prepared by stirring strongly was broken easily.

  • PDF

Sample Size Calculations for the Development of Biosimilar Products Based on Binary Endpoints

  • Kang, Seung-Ho;Jung, Ji-Yong;Baik, Seon-Hye
    • Communications for Statistical Applications and Methods
    • /
    • v.22 no.4
    • /
    • pp.389-399
    • /
    • 2015
  • It is important not to overcalculate sample sizes for clinical trials due to economic, ethical, and scientific reasons. Kang and Kim (2014) investigated the accuracy of a well-known sample size calculation formula based on the approximate power for continuous endpoints in equivalence trials, which has been widely used for Development of Biosimilar Products. They concluded that this formula is overly conservative and that sample size should be calculated based on an exact power. This paper extends these results to binary endpoints for three popular metrics: the risk difference, the log of the relative risk, and the log of the odds ratio. We conclude that the sample size formulae based on the approximate power for binary endpoints in equivalence trials are overly conservative. In many cases, sample sizes to achieve 80% power based on approximate powers have 90% exact power. We propose that sample size should be computed numerically based on the exact power.

The Influence of Sample Size on Environment Assessment Using Benthic Macroinvertebrates (저서성 대형무척추동물을 이용한 환경평가에서 표본크기가 미치는 영향)

  • Kim, Ah Reum;Oh, Min Woo;Kong, Dongsoo
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.6
    • /
    • pp.790-798
    • /
    • 2013
  • Benthic macroinvertebrates are widely used as biological indicators for assessing the integrity of aquatic ecosystem. However, sampling has usually been done with fixed sample size due to time consuming and costly process. This study was conducted to find out the influence of sample size on the biological indices (H' DI, R1, J, EPT, ESB and BMI) of benthic macroinvertebrates. The 15 replicate samples were quantitatively collected from each 3 different site of two mountain streams in May, 2011. With the replicate data, we combined the abundance of each species with all the possible combinations of the sample size. Along with the increase of sample size, the number of species increased continuously and did not converge. BMI showed little difference whereas other biological indices increased or decreased.