• Title/Summary/Keyword: site contaminants

Search Result 138, Processing Time 0.022 seconds

Weathering Impact for Rock Properties and Material Characteristics of Concretes Used Stone Pagoda of the Mireuksaji Temple Site, Iksan, Korea (익산 미륵사지 석탑에 사용된 콘크리트의 재료학적 특성과 석재의 풍화에 미치는 영향)

  • Lee Dong-Sik;Lee Chan-Hee;Kim Ji-Young
    • Economic and Environmental Geology
    • /
    • v.39 no.3 s.178
    • /
    • pp.285-299
    • /
    • 2006
  • The Mireuksaji stone pagoda in Iksan is the largest stone pagoda existing in Eastern Asia. It was assumed that originally it had been established in the shape of nine-storied pagoda but as time went by only six-storied pagoda remained partially due to collapsing, repair and reconstruction. According to the reference, we can't make sure when its modification happened. The form that the pagoda is having now, was modified with concrete by the Japanese during the 1910s. The materials mixed in concrete were mixture of Portland cement, all sorts of stone, sand, and a little bit of new building stone, additive and compound. And also these materials were applied to cultural assets without any experiment at the time of 1910s as maintenance, which are still used recently. To prevent the change of its shape, the west side, south side and the north side which is partially destructed was rebuilt and reinforced with concrete and some of the deformed parts were also filled. The amounts of concrete used were about 200 tons. Such method had prevented the pagoda from destructing, however, by choosing a wrong repair method, its surface of the stone has secondary contaminants and precipitation caused by concrete. This kind of contamination speeds up the weathering which accelerates the aging mechanism of the stone to make it even harder to revive the absence of historical nature. Therefore, we are to find the best cleaning method to remove the secondary hazard contaminants.

Soil Pollution and Contaminated Soil Management of the Public Housing Agency in Residential Land Development (전국 토양오염실태 및 공공택지개발지구의 오염토양 관리)

  • Oh, Jeongik;Jin, Kyunam;Lee, Hyunjeong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.7
    • /
    • pp.377-386
    • /
    • 2016
  • The purposes of this research are to examine soil pollution in the nation and to explore the contaminated soil management of the public housing agency in public land for residential development. In so doing, the primary and secondary data were utilized, the former made use of the public data annually released by the Korea Ministry of Environment, and the latter relied on a self-administerd questionnaire survey conducted in the staff of the public housing agency, particularly those in charge of soil contamination in large-scale land, housing and urban development projects. The findings reveal that the national concentrations of 21 inorganic and organic soil contaminants (e.g., Cd, Cu, As, Hg, Pb, Cr, Zn, Ni, F, P, PCB, CN, Phenol, BTEX, TPH, TCE, PCE, Benzo(a)pyrene, and pH) in the land were extracted to be well below the risk level designated by the statutory guidance while industrial areas had them at a relatively modest level. In addition, the survey results indicate that the public housing agency didn't establish specific and clear guidelines for soil pollution and its remediation in the residential land development, so that contaminated sites have been primarily remediated by outsourcing companies. As the unexpected occurrence of contaminated sites causes the incurring expenses added to total project budget, the provision of both professional training and on-site manuals with the sufficient information on techniques and methods of soil contamination is critical to promptly and systematically deal with soil pollution.

Estimation of Cadmium, Copper, Lead Mobility in Column Packed with Furnace Slag (제강슬래그로 충전된 컬럼에서의 카드뮴, 구리, 납의 이동성 평가)

  • Lee, Gwang-Hun;Chung, Jae-Shik;Nam, Kyoung-Phile;Park, Jun-Boum
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.4
    • /
    • pp.54-61
    • /
    • 2008
  • Permeable reactive barriers (PRBs) technology has been focused in contaminated groundwater remediation. It is necessary to select adequate reactive material according to characteristics of contaminant in groundwater. In this research, the reaction between reactive material and heavy metal contaminants was estimated through column test. Reactive material was slag, which has been produced in Gwangyang power plant, and heavy metal contaminants were cadmium, lead and copper. Column test was performed in the condition of 1) single and multi contaminated solution and 2) different initial concentration of cadmium. Retardation factor of cadmium is 3.94 in multi contamination. But that of copper is 40.3 in single and 25 in multi. The difference of retardation between cadmium and copper is due to affinity, resulted from the difference of electronegativity. In multi-contamination, copper effluent concentration was above initial copper concentration and at the same time lead effluent concentration was decreased. This phenomenon was considered that lead extract copper sorbed in slag and then lead was sorbed to the vacant sorption site instead. And as the initial concentration was increased, the retardation factor of cadmium became decreased.

The Contamination Characteristics of the Nanji Uncontrolled Landfill and its Surrounding Hydrogeologic Environment (난지도 매립지 주변 지하수환경의 오염 특성에 관한 연구)

  • 이철효;한정상
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.3 no.1
    • /
    • pp.27-36
    • /
    • 1996
  • The Nanji landfill is one of the biggest uncontrolled landfill in terms of its size and scale in the world. Because the landfill was constructed on the very vulnerable alluvial deposit installing no pollution control systems such as bottom liner and leachate collection systems, it has caused a serious adverse effect to near-by groundwater and surface water systems. A through remedial investigation comprising plume detection and site-characterization was performed to design the remedial measure. As a part the investigation, comprehensive water quality study was conducted, using ten existing observation wells and one bundle type monitoring well, to determine the contaminant indicators for the plume delineation and to define the vertical and horizontal variation of specific contaminants via distances from the landfill. The results clearly shows that EC and temperature are a good pollution indicators and the vertical concentrations of specific contaminants measured in the fully screened wells are 20 to 90% more than those measured at the same depth in bundle type well which is located just 2 m apart. This paper presents a cost effective monitoring and sampling method to define the contaminant plume and obtain a basic data for leachate control measures.

  • PDF

Investigation of the fate of inorganic nitrogens in the near field of bank filtration site (강둑여과지 주변의 밭에 살포된 무기질소의 거동 연구)

  • 공인철;배진희;안호준;권오억;김승현;이철희;박영규
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.1
    • /
    • pp.11-20
    • /
    • 1998
  • Inorganic nitrogens resulting from fertilizers are possible contaminants of bank-filtered ground water, which is an alternative source of safe drinking water. We conducted a laboratory study to determine the fate of inorganic nitrogens in the near field of bank filtration sites and we consequently illustrated the effects of these possible contaminants on the water quailty of bank filtration. Soil properties were found to be well equivalent to those of other cultivated field soils in Korea. Surface soil pH was about 4.3 which is slightly lower than average level. Overall, diverse concentrations of $NO_3$-N and $NH_3$-N were measured, and $NO_2$-N was nearly undetected. $NH_3$-N level in the field decreased, while $NO_3$-N increased along with increasing depth of unsaturated zone. Numbers of viable and nitrifying bacteria ranged from 6.73$\times$$10^{6}$to 10.7$\times$$10^{6}$ and 0.44$\times$$10^{4}$ to 5.21$\times$$10^{4}$ respectively, and both of them were highly correlated ($R^{2}$=0.992). Nitrifying potential assayed by batch test showed relatively lower than other reported results. The oxygen uptake potential of surface and subsurface soil was measured in the presence of ${(NH_4)_2}$$SO_4$. The results demonstrated that surface soil required shorter lag period and uptaked more oxygen than subsurface's.

  • PDF

Recent Progress in Membrane based Colorimetric Sensor for Metal Ion Detection (색 변화를 활용한 중금속 이온 검출에 특화된 멤브레인 기반 센서의 최근 연구 개발 동향)

  • Bhang, Saeyun;Patel, Rajkumar
    • Membrane Journal
    • /
    • v.31 no.2
    • /
    • pp.87-100
    • /
    • 2021
  • With a striking increase in the level of contamination and subsequent degradations in the environment, detection and monitoring of contaminants in various sites has become a crucial mission in current society. In this review, we have summarized the current research areas in membrane-based colorimetric sensors for trace detection of various molecules. The researches covered in this summary utilize membranes composed of cellulose fibers as sensing platforms and metal nanoparticles or fluorophores as optical reagents. Displaying decent or excellent sensitivity, most of the developed sensors achieve a significant selectivity in the presence of interfering ions. The physical and chemical properties of cellulose membrane platforms can be customized by changing the synthesis method or type of optical reagent used, allowing a wide range of applications possible. Membrane-based sensors are also portable and have great mechanical properties, which enable on-site detection of contaminants. With such superior qualities, membrane-based sensors examined in the researches were used for versatile purposes including quantification of heavy metals in drinking water, trace detection of toxic antibiotics and heavy metals in environmental water samples. Some of the sensors exhibited additional features like antimicrobial ability and recyclability. Lastly, while most of the sensors aimed for a detection enabled by naked eyes through rapid colour change, many of them investigated further detection methods like fluorescence, UV-vis spectroscopy, and RGB colour intensity.

Conservation Treatment on the Bamboo Sunblind from the No. 1 Catchment Site in Baesanseongji, Busan (부산 배산성지 1호 집수지 출토 대나무 발 수습 및 보존처리)

  • Park, Ji Hyeon;Park, Jung Hae;Lee, Kwang Hee;Seo, Yeon Ju;Park, Jung Wook;Kim, Soo Chul
    • Journal of Conservation Science
    • /
    • v.37 no.5
    • /
    • pp.536-544
    • /
    • 2021
  • In the present study, safe management and value improvement of bamboo sunblind, which is an item of cultural heritage, were performed by adopting stable conservation treatment methods. The bamboo sunblind used in the present study was excavated from No. 1 catchment site in Baesanseongji, Busan. It was determined that the main material used to make the sunblind was bamboo, and herbal plants were used to weave the bamboo using lacquer as an adhesive agent. All contaminants and soil adhered to the sunblind was removed. Thereafter, the sunblind, which was recovered in the form of blocks, was washed separately after fixing it to a temporary plaster frame and to avoid the blocks from breaking during washing. Then, polyethylene glycol (PEG) impregnation was utilized for the reinforcement treatment. Based on the preliminary test results, the shape of the sunblind was fixed using a stainless-steel frame to prevent physical damage that may occur during the drying process. Thereafter, the bamboo sunblind was vacuum freeze-dried. PEG 20% (in ethyl alcohol) was applied as a surface treatment agent for stabilization the sunblind. After the surface treatment, the bamboo sunblind were joined together to fit the maximum width, and the rectangular shape of the sunblind was restored-as best as possible-while filling in the missing parts by maximizing the use of unknown members such as in the disturbed layers below bamboo sunblind surface. The conservation treatment was completed by fixing the bamboo sunblind into the fabricated frame.

Prediction of Potential Risk Posed by a Military Gunnery Range after Flood Control Reservoir Construction (홍수조절지 건설 후 사격장 주변지역의 위해성예측 사례연구)

  • Ryu, Hye-Rim;Han, Joon-Kyoung;Nam, Kyoung-Phile;Bae, Bum-Han
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.1
    • /
    • pp.87-96
    • /
    • 2007
  • Risk assessment was carried out in order to improve the remediation and management strategy on a contaminated gunnery site, where a flood control reservoir is under construction nearby. Six chemicals, including explosive chemicals and heavy metals, which were suspected to possess risk to humans by leaching events from the site were the target pollutants for the assessment. A site-specific conceptual site model was constructed based on effective, reasonable exposure pathways to avoid any overestimation of the risk. Also, conservative default values were adapted to prevent underestimation of the risk when site-specific values were not available. The risks of the six contaminants were calculated by API's Decision Support System for Exposure and Risk Assessment with several assumptions. In the crater-formed-area(Ac), the non-carcinogenic risks(i.e., HI values) of TNT(Tri-Nitro-Toluene) and Cd were slightly larger than 1, and for RDX(Royal Demolition Explosives), over 50. The total non-carcinogenic risk of the whole gunnery range calculated to a significantly high value of 62.5. Carcinogenicity of Cd was estimated to be about $10^{-3}$, while that of Pb was about $5\;{\times}\;10^{-4}$, which greatly exceeded the generally acceptable carcinogenic risk level of $10^{-4}{\sim}10^{-6}$. The risk assessment results suggest that an immediate remediation practice for both carcinogens and non-carcinogens are required before the reservoir construction. However, for more accurate risk assessment, more specific estimations on condition shifts due to the construction of the reservoir are required, and more over, the effects of the pollutants to the ecosystem is also necessary to be evaluated.

In Situ Surfactant Flushing of Contaminated Site (계면 활성제를 이용한 In Situ 토양 세척)

  • 염익태;안규홍
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.2
    • /
    • pp.9-24
    • /
    • 1997
  • Surfactant-aided in situ soil flushing has been proposed as an alternative for the expensive and time consuming 'pump and treat' technology in remediation of contaminated soil and groundwater Injected surfactants can effectively solubilize contaminants sorbed to the soil matrix or nonaqueous phase liquids(NAPLs) in residual saturation. The contaminants solubilized in groundwater are recovered and treated further. The theoretical background of the technology and the results of the field operations, mostly in the US. were summarized. In addition, the factors crucial to the successful application of the technology were discussed. Cost analyses and technical limitations in current applications were also discussed. In conclusion, it is likely that in situ surfactant flushing become a viable option for soil remediation in limited cases. Currently, further advances with respect to operation cost and to treatment efficiency are required for more extensive application of the technology. However, the current trends in soil remediation, specially the growing emphasis on risk based corrective action and natural attenuation, will increase the competitiveness of the technology. For example, removal of easily washable contaminants by short term soil flushing followed by long term monitoring and natural attenuation can greatly reduce the operation cost and time.

  • PDF

A study on the color controlled of painter's work (페인트 도장공사의 색관리에 관한 연구)

  • Shim, Myung-Sup;Lee, Hyun-Jeong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.1
    • /
    • pp.107-114
    • /
    • 2003
  • This study aims to find methods that prevents aging of buildings paint coating and that limits defects in construction. Defects in painting can occur in four stages: pure paint, during painting, after the paint coating has dried, and after some period of time has passed after coating. Paint may become bad due to precipitation of pigments, formation of membranes, and seeding during manufacturing. Therefore, it is important that the paint is well mixed and kept airtight at a cool, dark place. Indents, paint brush strokes, orange peel, separation of colors, and paint running and spreading during the paint work process can be prevented by using high quality materials and applying a high-level of construction method. After the paint coating has dried, boiling, yellowing, poor drying, poor bonding, and/or glen deficiency may occur. These are influenced by the levels of cleanness of the dried product, drying temperature and hydration. Then, when the coating has been left dried for some period of time, cracking, peeling, scaling, swelling, discoloring, and/or rusting may develop due to the ultraviolet and contaminants in the air. Since these defects occur due to inappropriate construction schedule and/or hot and humid condition, one must use weatherproof materials. Furthermore, poor paint color may be caused by contamination in the sample plate, discoloration, and/or discrepancies in colors which are due to material differences, level of glossiness, degree of dispersion, dual color property of metallic colors, precipitation of pigments, etc. One should achieve reduction in construction cost and effectiveness in paint work by limiting contaminations in the construction site and strictly observing to construction regulations.