• Title/Summary/Keyword: single phase inverter

검색결과 561건 처리시간 0.027초

새로운 단상 3전위 인버터회로의 구성에 관한 연구 (A Study on Composition of A Novel Single Phase 3 Level Inverter Circuit)

  • 이종수;백종현
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권5호
    • /
    • pp.51-56
    • /
    • 1995
  • The transistors of single phase 3 level PWM Inverter compose output power transistors and neutral point clamping transistors, which are NPN transistors. Waveforms of driving signals for this are PWM waves for power transistors and period operating waves for neutral point clamping transistors, which signals made W-type modulation from rectangular and sine wave. The output power transistors operate at ON-time complementary and neutral point clamping transistors operate at OFF-time complementary respectively. Therefore, each transistors operate in half period at parallel. Characteristics of this inverter circuit is parallel switching method about series switching method of general inverter. As modulation of 3 level drive signals made from full-wave rectifier of sine wave and rectangular wave, which are level wave about 3 level of complementary transistor inverter. So, this circuit composed complementary operation inverter of NPN transistors only compare with PNP-NPN complementary inverter, which have high power 3 level inverter of complementary operation.

  • PDF

A Single-Phase Cell-Based Asymmetrical Cascaded Multilevel Inverter

  • Singh, Varsha;Pattnaik, Swapnajit;Gupta, Shubhrata;Santosh, Bokam
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.532-541
    • /
    • 2016
  • A single-phase asymmetrical cascaded multilevel inverter is introduced with the goal of increasing power quality with the reduction of power in insulated-gate bipolar transistor (IGBT) switches. In the present work, the proposed inverter topology is analyzed and generalized with respect to different proposed algorithms for choosing different voltage source values. To prove the advantages of the proposed inverter, a case study involving a 17-level inverter is conducted. The simulation and experimental results with reduced THD are also presented and compared with the MATLAB/SIMULINK simulation results. Finally, the proposed topology is compared with different multilevel inverter topologies available in the literature in terms of the number of IGBT switches required with respect to the number of levels generated in the output of inverter topologies.

Modified RCC MPPT Method for Single-stage Single-phase Grid-connected PV Inverters

  • Boonmee, Chaiyant;Kumsuwan, Yuttana
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1338-1348
    • /
    • 2017
  • In this study, a modified ripple correlation control (RCC) maximum-power point-tracking (MPPT) algorithm is proposed for a single-stage single-phase voltage source inverter (VSI) on a grid-connected photovoltaic system (GCPVS). Unlike classic RCC methods, the proposed algorithm does not require high-pass and low-pass filters or the increment of the AC component filter function in the voltage control loop. A simple arithmetic mean function is used to calculate the average value of the photovoltaic (PV) voltage, PV power, and PV voltage ripples for the MPPT of the RCC method. Furthermore, a high-accuracy and high-precision MPPT is achieved. The performance of the proposed algorithm for the single-stage single-phase VSI GCPVS is investigated through simulation and experimental results.

PLL 기법을 이용한 단상 PWM 인버터의 정상상태 성능개선 (Steady-State Performance Improvement of Single-Phase PWM Inverters Using PLL Technique)

  • 정세교;이대식
    • 전력전자학회논문지
    • /
    • 제9권4호
    • /
    • pp.356-363
    • /
    • 2004
  • 본 논문에서는 무정전 전원장치와 같이 일정전압 일정주파수(constant voltage and constant frequency; CVCF) 운전에 사용되는 단상 PWM 인버터의 정밀 전압제어 기법을 다루었으며 정상상태에서 전압 오차를 최소화하기 위해 phase-locked loop(PLL) 기법을 이용한 새로운 전압 제어 방법을 제안하였다. 제안된 제어기법에서는 출력 커패시터 전압과 전류를 이용하여 PLL 보상기를 구성하였으며 주제어기에 PLL 보상기를 추가하여 출력 전압의 정상상태 성능을 개선하였다. 제안된 방법의 타당성을 검증하기 위하여 시뮬레이션과 실험을 수행하였으며, 그 결과 기존의 방법에 비해 정상상태 전압제어 성능과 Total Harmonic Distortion(THD)이 현저히 개선됨을 입증할 수 있었다.

마이크로컨트롤러를 이용한 벅-부스트 DC-AC 인버터 설계 (Design of Buck-Boost DC-AC Inverter Using Microcontroller)

  • 박종규
    • 조명전기설비학회논문지
    • /
    • 제23권10호
    • /
    • pp.45-51
    • /
    • 2009
  • 단상 벅-부스트 DC-AC 인버터는 2개의 DC-DC 컨버터로 이루어져 있다. 두 컨버터는 $180[^{\circ}]$의 위상차를 가지는 DC 바이어스된 정현파 기준 전압에 의해 구동된다. 교류로 출력되는 인버터의 최대값은 직류 입력전압 크기에 제약을 받지 않아 입력 직류전원보다 높은 교류 출력전압을 만들 수 있다. 본 논문에서는 벅-부스트 DC-AC인버터를 설계하고, 프로토타입을 제작하여 실험한다. 전압과 전류 제어기는 마이크로컨트롤러를 이용한 디지털 제어기로 구현된다.

전력 디커플링 기능을 가진 단상 계통연계 전압형 인버터 (Single Phase Grid Connected Voltage-ed Inverter Utilizing a Power Decoupling Function)

  • 이상욱;문상필;박한석
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.236-241
    • /
    • 2017
  • This paper presents a single-phase grid connected voltage-ed inverter with a power decoupling circuit. In the single-phase grid connected voltage-ed inverter, it is well known that a power pulsation with twice the grid frequency is contained in the input power. In a conventional voltage type inverter, electrolytic capacitors with large capacitance have been used in order to smooth the DC voltage. However, lifetime of those capacitors is shortened by the power pulsation with twice grid frequency. The authors have been studied a active power decoupling(APD) method that reduce the pulsating power on the input DC bus line, this enables to transfer the ripple energy appeared on the input DC capacitors into the energy in a small film capacitor on the additional circuit. Hence, extension of the lifetime of the inverter can be expected because the small film capacitor substitutes for the large electrolytic capacitors. Finally, simulation and experimental results are discussed.

단상 계통연계 인버터를 위한 새로운 고조파 보상법 (A Novel Harmonic Compensation Method for the Single Phase Grid Connected Inverters)

  • 칸 아마드 레이안;아쉬라프 모하마드 노만;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.144-146
    • /
    • 2018
  • In order to meet the harmonics standards such as IEEE 519 and P1547 the output quality of a grid connected inverter should satisfy a certain level of Total Harmonic Distortion (THD) value. However, the output quality of an inverter gets degraded due to the grid voltage harmonics, the dead time effects and the nonlinearity of the switches, which all contributes to a higher THD value of the output. In order to meet the required THD value for the inverter output under the distorted grid condition the use of harmonic controller is essential. In this paper a novel feedforward harmonic compensation method is proposed in order to effectively eliminate the low order harmonics in the inverter current to the grid. In the proposed method, unlike the conventional harmonic control methods, the hamonic components are directly compensated by the feedforward terms generated by the PR controller with the grid current in the stationary frame. The proposed method is simple in implementation but powerful in eliminating the harmonics from the output. The effectiveness of proposed method is verified through the PSIM simulation and the experiments with a 5kW single phase grid connected inverter.

  • PDF

수동 바이패스 필터를 이용한 단상 무변압기형 인버터 (Single-Phase Transformerless Inverter using Passive Bypass Filter)

  • 양민권;허준;이명철;김유진;최우영
    • 전력전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.129-138
    • /
    • 2018
  • Previous single-phase transformerless inverters used active bypass switching circuits that need auxiliary power switches to minimize ground leakage current. However, switching and gate driving losses are increased due to the use of additional power switches. To cope with this drawback, this work proposes a transformerless inverter using a passive bypass filter without any auxiliary power switch. The operation and control of the proposed inverter are described. The ground leakage current characteristics are analyzed for the proposed inverter with the passive bypass filter. The experimental results of the proposed inverter for a 1.0kW prototype system are presented.

냉장고의 선형압축기 구동을 위한 단상 하프브리지 인버터 시스템에서 직류단 불평형 보상에 관한 연구 (DC Voltage Balancing Control of Half-Bridge PWM Inverter for Liniear Compressor of Refrigerator)

  • 김호진;김형진;김동윤;김장목
    • 전력전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.256-262
    • /
    • 2017
  • This paper presents the control algorithm of a single-phase AC/DC/AC PWM converter for the linear compressor of a refrigerator. The AC/DC/AC converter consists of a full-bridge PWM converter for the control of the input power factor and a half-bridge PWM inverter for the control of the single-phase linear compressor. At the DC-link of this topology, two capacitors are connected in series. These DC-link voltages must be balanced for safe operation. Thus, a new control method of DC voltage balancing for the half-bridge PWM inverter is proposed. The balancing algorithm uses the Integral-Proportional controller and inserts the DC-offset current at the Proportional-Resonant current controller of the inverter to solve the DC-link unbalanced voltages between the two capacitors. The proposed algorithm can be easily implemented without much computation and additional hardware circuit. The usefulness of the proposed algorithm is verified through several experiments.

단상 계통연계 인버터를 위한 개선된 고조파 보상법 (An Improved Harmonic Compensation Method for a Single-Phase Grid Connected Inverter)

  • 칸 레이안;최우진
    • 전력전자학회논문지
    • /
    • 제24권3호
    • /
    • pp.215-227
    • /
    • 2019
  • Grid-connected inverters should satisfy a certain level of total harmonic distortion (THD) to meet harmonics standards, such as IEEE 519 and P1547. The output quality of an inverter is typically degraded due to grid voltage harmonics, dead time effects, and the device's turn-on/turn-off delay, which all contribute to increasing the THD value of the output. The use of a harmonic controller is essential to meet the required THD value for inverter output under a distorted grid condition. In this study, an improved feedforward harmonic compensation method is proposed to effectively eliminate low-order harmonics in the inverter current to the grid. In the proposed method, harmonic components are directly compensated through feedforward terms generated by the proportional resonant controller with the grid current in a stationary frame. The proposed method is simple to implement but powerful in eliminating harmonics from the output. The effectiveness of the proposed method is verified through simulation using PSIM software and experiments with a 5 kW single-phase grid-connected inverter.