• Title/Summary/Keyword: single loop control

Search Result 303, Processing Time 0.027 seconds

An FPGA-based Fully Digital Controller for Boost PFC Converter

  • Lai, Li;Luo, Ping
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.644-651
    • /
    • 2015
  • This paper introduces a novel digital one cycle control (DOCC) boost power factor correction (PFC) converter. The proposed PFC converter realizes the FPGA-based DOCC control approach for single-phase PFC rectifiers without input voltage sensing or a complicated two-loop compensation design. It can also achieve a high power factor and the operation of low harmonic input current ingredients over universal loads in continuous conduction mode. The trailing triangle modulation adopted in this approach makes the acquisition of the average input current an easy process. The controller implementation is based on a boost topology power circuit with low speed, low-resolution A/D converters, and economical FPGA development board. Experimental results demonstrate that the proposed PFC rectifier can obtain a PF value of up to 0.999 and a minimum THD of at least 1.9% using a 120W prototype.

Gird-interactive Current Controlled Voltage Source Inverter System with UPS (UPS를 고려한 계통연계 전류제어형 전압원 인버터)

  • Ko, Sung-Hun;Lim, Sung-Hun;Lee, Su-Won;Lee, Seong-Ryong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1064-1070
    • /
    • 2007
  • This paper presents a grid-interactive current controlled voltage source inverter (CCVSI) with uniterruptible power supply (UPS), which uses an inner current control loop (polarized ramp time (PRT)) and outer feedback control loops to improve grid power quality and UPS. To reduce the complexity, cost and number of power conversions, which results in higher efficiency, a single stage CCVSI is used. The operation of this system could be divided into the power quality control (PQC) state mode and the UPS state mode. In PQC mode, the system operated to compensate the reactive power demand by nonlinear load or variation in load. In UPS mode. the system is controlled to provide a sinusoidal voltage at the rated value for the load when the gird fail. To verify the proposed system, a comprehensive evaluation with theoretical analysis, simulation and experimental results for 1KVA load capacity is presented.

Vibration suppression of rotating blade with piezocomposite materials (Piezocomposite 재료를 사용한 회전하는 블레이드의 진동억제)

  • Choi Seung-Chan;Kim Ji-Hwan
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.10a
    • /
    • pp.282-285
    • /
    • 2004
  • The main purpose of this study is the vibration suppression of rotating composite blade containing distributed piezoelectric sensors and actuators. The blade is modeled by thin-walled, single cell composite beam including the warping function, centrifugal force, Coriolis acceleration and piezoelectric effect. Further, the numerical study is performed m ing finite element method. The vibration of composite rotor is suppressed by piezocomposite actuators and PVDF sensors that are embedded between composite layers. A velocity feedback control algorithm coupling the direct and converse piezoelectric effect is used to actively control the' dynamic response of an integrated structure through a closed control loop. Responses of the rotating blade are investigated. Newmark time integration method is used to calculate the time response of the model. In the numerical simulation, the effect of parameters such as rotating speed, fiber orientation of the blade and size of actuators are studied in detail.

  • PDF

A Study on Reliable Control System Using an Additive Redundant Adaptive Controller (가법적 중복적응 제어기를 이용한 신뢰성 제어 시스템에 관한 연구)

  • ;;Zeungnam Bien
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.3
    • /
    • pp.301-311
    • /
    • 1990
  • A multiple controller structure consisting of a typical feedback controller and an additive redundant controller is proposed for enhancing the reliability of the control system. For the case where the main controller is chosen as a pole assignment controller with input/output measurements and the redundant controller as the Model Reference Adaptive Controller (MRAC) whose reference model is the closed-loop combination of the plant and the main controller, it is proven that the tracking error between the command input and plant output converges to zero under failure in one of the controllers or parameter perturbations of the plant, and further that the reliability measured by Mean Time To Failure (MTTF) is greater than that of the system with only a single main controller. A simulation Example is provided to illustrate reliable operation of the proposed control system against the controller failure.

  • PDF

Development of Nested PCR, Multiplex PCR, and Loop-Mediated Isothermal Amplification Assays for Rapid Detection of Cylindrocladium scoparium on Eucalyptus

  • Qiao, Tian-Min;Zhang, Jing;Li, Shu-Jiang;Han, Shan;Zhu, Tian-Hui
    • The Plant Pathology Journal
    • /
    • v.32 no.5
    • /
    • pp.414-422
    • /
    • 2016
  • Eucalyptus dieback disease, caused by Cylindrocladium scoparium, has occurred in last few years in large Eucalyptus planting areas in China and other countries. Rapid, simple, and reliable diagnostic techniques are desired for the early detection of Eucalyptus dieback of C. scoparium prior to formulation of efficient control plan. For this purpose, three PCR-based methods of nested PCR, multiplex PCR, loop-mediated isothermal amplification (LAMP) were developed for detection of C. scoparium based on factor 1-alpha (tef1) and beta-tubulin gene in this study. All of the three methods showed highly specific to C. scoparium. The sensitivities of the nested PCR and LAMP were much higher than the multiplex PCR. The sensitivity of multiplex PCR was also higher than regular PCR. C. scoparium could be detected within 60 min from infected Eucalyptus plants by LAMP, while at least 2 h was needed by the rest two methods. Using different Eucalyptus tissues as samples for C. scoparium detection, all of the three PCR-based methods showed much better detection results than regular PCR. Base on the results from this study, we concluded that any of the three PCR-based methods could be used as diagnostic technology for the development of efficient strategies of Eucalyptus dieback disease control. Particularly, LAMP was the most practical method in field application because of its one-step and rapid reaction, simple operation, single-tube utilization, and simple visualization of amplification products.

A Study on Spark Advance Control System using Microprocessor (마이크로프로세서를 이용한 엔진점화시기 제어장치)

  • Min, Y.B.;Lee, K.M.;Lee, S.K.;Kim, Y.H.
    • Journal of Biosystems Engineering
    • /
    • v.14 no.2
    • /
    • pp.80-84
    • /
    • 1989
  • In order to improve the combustion efficiency of the agricultural engine, an ignition timing control system was developed and tested. The control system was composed of the CDI ignition circuit, the microcomputer and the interfacing devices. In this study, the simplicity of the control system and the flexibility of the control strategy were emphasized for the precision, the applicability and the economical efficiency. The hardware was consisted in almost the same compositions as those of the automobile engine. The softwares of the control algorithms were developed to three types depending on the combination of the quasi-adaptive control and the open loop control which had the different spark advance equations according to the input variables such as engine speed, exhaust gas temperature and brake torque. The test results were summarized as follows: 1. By using the computer control system, the fuel consumption efficiency could be improved and the fuel consumption could be reduced by 0 to 57% compared to that of the fixed spark advance system. 2. The fuel consumption of the control mode with the quasi-adaptive algorithm was reduced by average 0.8% compared to that of the control mode without quasi-adaptive algorithm. 3. It was found that the control mode with the quasi-adaptive algorithm adopting single input of engine speed had most applicability and economical efficiency among three types of the control algorithms.

  • PDF

A Study on the Single Phase Voltage-Controlled Active Power Filter for Power Quality Improvement (전력품질 개선을 위한 단상 전압제어형 능동전력필터 시스템에 관한 연구)

  • 손진근
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.5
    • /
    • pp.238-245
    • /
    • 2003
  • In this paper, a single Phase voltage source voltage-controlled active power filter(APF) for power quality improvement was proposed. The proposed APF has the performance of harmonic suppression and unity power factor correction. The performance of harmonic suppression can be obtained by controlling the waveshape of the APF output voltage to be sine wave. And, unity power factor is controlled by the reactive power control loop of the APF output. Simulation and experimental results using diode rectifier showed that the voltage-controlled APF, unlike the current-controlled APF, can reduce the voltage harmonics as well as current harmonics. Also the results showed that the input dover factor and power quality were greatly improved.

The Starting System Implementation of SPIM with Detecting Main Winding Current (주권선 전류검출에 의한 단상유도전동기의 구동시스템 구현)

  • 최낙일;박수강;오금곤;백형래;임양수;오기진
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.166-170
    • /
    • 1997
  • A Single phase induction motor is the predominant fractional horsepower power rated, extensively used in domestic and industrial application. For example, these motors provide the motive power to washing machines, fans, refrigerators, etc. In this paper, single phase induction motor input current was detected by a small current transformer and determined TRIAC gate signal by using op-amp analog circuit. The soft-start strategy is based on limited auxiliary current angle during starting period in the closed-loop control. The Simulation and experimental result show the motor's starting characteristics of the proposal starting system and are compared with centrifugal switch starting motor.

  • PDF

Controller Design of Single-phase Inverter Based on Pole-assignment Method (극 배치 기법을 기반으로 한 단상인버터의 제어기 설계)

  • Son, Kyoung-Min;Lee, Jin-Mok;Noh, Se-Jin;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.139-141
    • /
    • 2008
  • This paper presents a PID controller and PI-PI dual loop controller for a single-phase inverter. The control parameters of conventional controllers are very difficult to make. But parameters of controllers based on pole-assignment are easy to make. Simulation results are presented for the system under R-L load, no load and change reference voltage.

  • PDF

A Single-ended Simultaneous Bidirectional Transceiver in 65-nm CMOS Technology

  • Jeon, Min-Ki;Yoo, Changsik
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.6
    • /
    • pp.817-824
    • /
    • 2016
  • A simultaneous bidirectional transceiver over a single wire has been developed in a 65 nm CMOS technology for a command and control bus. The echo signals of the simultaneous bidirectional link are cancelled by controlling the decision level of receiver comparators without power-hungry operational amplifier (op-amp) based circuits. With the clock information embedded in the rising edges of the signals sent from the source side to the sink side, the data is recovered by an open-loop digital circuit with 20 times blind oversampling. The data rate of the simultaneous bidirectional transceiver in each direction is 75 Mbps and therefore the overall signaling bandwidth is 150 Mbps. The measured energy efficiency of the transceiver is 56.7 pJ/b and the bit-error-rate (BER) is less than $10^{-12}$ with $2^7-1$ pseudo-random binary sequence (PRBS) pattern for both signaling directions.