• 제목/요약/키워드: single implants

검색결과 194건 처리시간 0.023초

Changes in Plasma Levels of Inhibin and Follicle Stimulating Hormone in Buffaloes Superovulated with eCG

  • Singh, Baljit;Dixit, V.D.;Dixit, V.P.;Singh, P.;Georgie, G.C.;Lohan, I.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제13권9호
    • /
    • pp.1205-1209
    • /
    • 2000
  • The present study was undertaken to investigate the effect of stimulation of follicular development with eCG on the peripheral levels of inhibin and FSH in Murrah buffaloes. Estrus was synchronized in five normally cycling females by insertion of Crestar (Intervet, Boxmeer, Holland) implants for nine days. Estradiol valerate was administered i.m. on the day of implant insertion. On the 10th day of the induced estrous cycle a single dose of 3000 IU eCG (Folligon, Intervet, Boxmeer, Holland) was given, followed by treatment with 25 mg of $PGF_2$ alpha (Lutalyse, Upjohn, Belgium) 48 h later. Blood samples were obtained during the induced estrus, on cycle day 10 (luteal phase), at the superovulatory estrus (43 h after PGF) and during the periovulatory period (64 h after PGF). Ultrasonography was done daily to monitor follicular development. Plasma concentrations of inhibin and FSH were determined by specific radioimmunoassays. Differences between $mean{\pm}SEM$ values of different phases of the cycle were compared by ANOVA. The mean number of small (2-5 mm), medium (6-9 mm) and large (>10 mm) follicles observed two days after eCG treatment and on the day of superovulatory estrus was $2.8{\pm}0.31$, $5.2{\pm}0.30$ and $1.4{\pm}0.09$ and $1.9{\pm}0.21$, $2.8{\pm}0.40$ and $5.0{\pm}0.83$, respectively. The mean number of ovulations was $3.6{\pm}0.37$ and the mean number of unovulated follicles was $6.1{\pm}0.47$. Most of the follicles >10 mm in diameter had ovulated (72%). The mean ${\pm}SEM $ of plasma inhibin concentration $(2584.15{\pm}17.92pg/ml)$ during the superovulatory estrus was significantly higher $(p{\leq}0.05)$ than during the induced estrus $(749.87{\pm}17.29pg/ml)$, the luteal phase $(1099.54{\pm}24.98pg/ml)$ and periovulatory period $(1682.71{\pm}29.88pg/ml)$, respectively. $Mean{\pm}SEM$ plasma FSH concentration during the induced estrus $(10.35{\pm}0.41ng/ml)$ was not different from that during the superovulatory estrus $(8.52{\pm}0.39ng/ml)$, but was significantly higher $(p{\leq}0.05)$ than during the luteal phase $(2.81{\pm}0.42ng/ml)$ and periovulatory period $(5.7{\pm}0.28ng/ml)$. These data indicate that treatment with eCG in buffaloes for inducing superovulation results in a significant elevation in plasma inhibin levels and a decrease in plasma FSH levels during the superovulatory estrus. Thus, we suggest that the elevated plasma inhibin coming from fully developed follicles continued for a long time which results in inhibition of FSH leading to poor ovulation in the remaining follicles, which may be the cause of suboptimal superovulatory response.

진료실 CAD-CAM에 의한 컴퓨터 가이드 임플란트 수술과 즉시 임시보철치료: 증례보고 (Computer-guided implant surgery and immediate provisionalization by chair-side CAD-CAM: A case report)

  • 현상우;이성복;이석원;조영은
    • 대한치과보철학회지
    • /
    • 제59권4호
    • /
    • pp.478-486
    • /
    • 2021
  • 치과와 기공실을 오가며 복잡하게 진행되는 기존 CAD-CAM 컴퓨터 가이드 제작 방식을 단 순화하기 위하여, 진료실에 설치한 바로가이드 시스템(VARO Guide, CAD, Pre-Guide, VARO-mill, NeoBiotech, Seoul, South Korea)을 통하여 Top-Down 개념과 수복 주도개념을 적용하여 1-day 수술과 임시보철을 완료하는 증례를 보고하고자 한다. Pre-Guide를 통해 환자의 중심위에서 교합을 채득하고 CT를 촬영하며, 진료실 내 컴퓨터에서 CAD를 통해 바로가이드를 1시간 내에 제작하였다. 미리 제작된 광중합 레진이 담긴 Pre-Guide 트레이를 술부에 위치시킨 후 중심위에서 CT를 촬영하였다. CT 데이터가 진료실 내 컴퓨터로 전송되면 수복 위치를 정한 후 이어서 3차원적으로 턱뼈에서 임플란트를 식립할 위치를 디자인하여 STL 파일로 추출하였다. 그리고 진료실에 설비된 밀링 기계(VARO-mill)에 Pre-Guide를 고정하여 수술용 가이드를 15분 내에 제작한다. 이 가이드로 환자는 한번 내원하여 임플란트를 계획한 위치에 안전하고 정확하게 수술해 줌과 더불어, 초기고정력이 양호한 임플란트에 대해서는 즉시임시치아까지 장착해 주어 환자에게 즉시 기능이 가능하도록 할 수 있었다.

심한 치조골 소실이 있는 상악 무치악 환자에서 Pekkton telescopic attachment를 이용한 임플란트 피개의치 증례 (A case of maxilla implant overdenture using Pekkton telescopic attachment with severe alveolar bone resorption)

  • 박하은;이원섭;이철원;이수영
    • 대한치과보철학회지
    • /
    • 제57권2호
    • /
    • pp.189-194
    • /
    • 2019
  • 심한 치조골 흡수를 동반한 편악 무치악 환자의 보철 수복시 대합치열의 상태를 고려하여 올바른 교합평면을 설정하고, 교합력이 균일하게 분산될 수 있는 치료가 제공되어야 한다. 임플란트 유지 피개의치는 소수의 임플란트로 치조골 흡수가 심한 완전 무치악 환자에게 총의치보다 우수한 유지와 안정성을 주는 치료이다. 최근 치과 영역에서 소개된 신소재 polyaryletherketone (PAEK) 기반의 폴리머(Pekkton ivory, Cendres + $M{\acute{e}}taux$ SA, Biel / Bienne, Switzerland)를 사용한 telescopic 어태치먼트는 전형적인 telescopic 코핑의 이점을 가지며, 내마모성이 뛰어나며, 기존의 임플란트 피개의치에 비해 가볍고 경제적인 장점이 있다. 본 증례에서는 상악 완전 무치악 환자에 임플란트를 5개 식립하여, Pekkton으로 내 외관이 제작된 텔레스코픽 어태치먼트를 활용한 임플란트 유지 피개의치를 제작하고, 하악은 임플란트 고정성 보철로 수복하였다. 심미적 및 기능적으로 만족스러운 결과를 얻었기에 이를 보고하는 바이다.

부분 무치악 환자에서 고기능성 폴리머(PEKK) 지대주를 이용한 임플란트 고정성 보철물 수복 증례 (Implant-supported fixed prostheses with high-performance polymer (PEKK) abutments in partial edentulous patients: A case report)

  • 하승룡
    • 대한치과보철학회지
    • /
    • 제59권1호
    • /
    • pp.71-78
    • /
    • 2021
  • 완전무치악 환자한테 처음으로 시도되었던 임플란트 보철치료는 현재는 단일치아 상실된 경우까지 그 활용범위가 넓어졌으며, 임플란트 보철치료는 현대 치과에서는 거의 필수적인 치료방법으로 자리매김 하였다. 임플란트 보철물을 제작하는데 사용되는 재료도 초기에 비해 다양해졌는데, 그 중 하나가 고기능성 폴리머의 적용이다. 예전부터 의과에서 많이 사용되어 왔던 고기능성 폴리머를 치과에서도 시도하는 빈도가 점점 늘어나고 있다. 이에 고기능성 폴리머를 구치부 임플란트 지대주로 사용한 3가지 증례를 보고하고자 한다. 첫번째 증례는 하악 좌측 제2소구치가 상실된 부위에 PEKK 지대주 및 PFG 크라운(시멘트-나사-유지형)을 제작, 장착하였으며, 두번째 증례는 상실된 상악 좌측 제1대구치 부위에 PEKK 지대주 및 monolithic zirconia 크라운(시멘트-나사-유지형)을 제작, 장착하였으며, 마지막 증례는 상악 우측 제1,2 대구치 상실부위에 PEKK 지대주 및 splinted PFM 크라운(시멘트-나사-유지형)을 제작하여 장착하였다. 4년의 추적 관찰 결과 상기 환자 모두 심미적 및 기능적으로 만족스러운 결과를 얻었기에 증례를 보고하고자 한다.

임플란트 연결부의 개념과 적용: Part 2. 안착형 외부 및 내부 연결형 임플란트의 식립과 보철 (Concept and application of implant connection systems: Part II. Placement and restoration of external connection implant and tissue level implant)

  • 고경호;강현구;허윤혁;박찬진;조리라
    • 구강회복응용과학지
    • /
    • 제36권4호
    • /
    • pp.222-231
    • /
    • 2020
  • 안착형 외부 연결 임플란트를 적절히 사용하기 위해서는 식립 시에 임플란트 간의 간격에 주의해야 하며 2차 수술 시에 임플란트 상부로 올라간 골을 다듬어야 한다. 육각형태를 가진 지대주가 원형 지대주에 비해 유용하다. 외부 연결형 임플란트는 악간간격이 제한된 경우에 적용할 수 있다. 안착형 외부연결(조직수준) 임플란트는 상부 직경의 두께로 인한 생역학적 장점과 내재된 점막관통부로 인한 생물학적 장점을 가지고 있다. 조직수준 임플란트를 수복할 때 지대주 수준과 임플란트 수준의 변연 중 악간공간에 따라 선택한다. 어떤 한 가지 임플란트 종류로는 모든 증례를 만족시키기 어려우므로 교합력 및 골조건을 고려하여 적절한 임플란트를 선택하는 것이 필요하다.

Evaluation of the clinical and radiographic effectiveness of treating peri-implant bone defects with a new biphasic calcium phosphate bone graft: a prospective, multicenter randomized controlled trial

  • Jae-Hong Lee;Hyun-wook An;Jae-Seung Im;Woo-Joo Kim;Dong-Won Lee ;Jeong-Ho Yun
    • Journal of Periodontal and Implant Science
    • /
    • 제53권4호
    • /
    • pp.306-317
    • /
    • 2023
  • Purpose: Biphasic calcium phosphate (BCP), a widely used biomaterial for bone regeneration, contains synthetic hydroxyapatite (HA) and β-tricalcium phosphate (β-TCP), the ratio of which can be adjusted to modulate the rate of degradation. The aim of this study was to evaluate the clinical and radiographic benefits of reconstructing peri-implant bone defects with a newly developed BCP consisting of 60% β-TCP and 40% HA compared to demineralized bovine bone mineral (DBBM). Methods: This prospective, multicenter, parallel, single-blind randomized controlled trial was conducted at the periodontology departments of 3 different dental hospitals. Changes in clinical (defect width and height) and radiographic (augmented horizontal bone thickness) parameters were measured between implant surgery with guided bone regeneration (GBR) and re-entry surgery. Postoperative discomfort (severity and duration of pain and swelling) and early soft-tissue wound healing (dehiscence and inflammation) were also assessed. Data were compared between the BCP (test) and DBBM (control) groups using the independent t-test and the χ2 test. Results: Of the 53 cases included, 27 were in the test group and 26 were in the control group. After a healing period of 18 weeks, the full and mean resolution of buccal dehiscence defects were 59.3% (n=16) and 71.3% in the test group and 42.3% (n=11) and 57.9% in the control group, respectively. There were no significant differences between the groups in terms of the change in mean horizontal bone augmentation (test group: -0.50±0.66 mm vs. control groups: -0.66±0.83 mm, P=0.133), postoperative discomfort, or early wound healing. No adverse or fatal complications occurred in either group. Conclusions: The GBR procedure with the newly developed BCP showed favorable clinical, radiographic, postoperative discomfort-related, and early wound healing outcomes for peri-implant dehiscence defects that were similar to those for DBBM.

양측성 단일 임플란트 지지 서베이드 크라운을 이용한 하악 임플 란트 보조 국소의치 수복 증례 (Implant assisted removable partial denture using bilateral single implant-supported surveyed crown: a case report)

  • 최서준;문홍석;김재영
    • 대한치과보철학회지
    • /
    • 제62권2호
    • /
    • pp.146-156
    • /
    • 2024
  • 임플란트 보조 국소의치의 치료는 오래전부터 여러 형태로 시도되어 왔으며, 이 중 임플란트 서베이드 크라운 국소의치의 경우 점차 예지성을 얻고 있으며, 특히 경제적, 해부학적으로 불리한 부분 무치악 환자에게 한 가지 치료 방법이 될 수 있다. 이때 임플란트의 식립 위치는 치료 목적에 따라 전방 식립과 후방 식립으로 분류될 수 있는데, 이는 환자의 치조제, 잔존치 예후, 대합치 등 여러 상황을 고려하여 결정되어야 한다. 본 증례에서는 하악 Kennedy 1급 부분 무치악 환자에게 두 개의 임플란트 서베이드 크라운을 활용한 하악 임플란트 보조 국소의치를 통해 수복하였다. 본 환자에게 후방 식립이 어렵다는 점과 잔존치의 예후를 고려하여 임플란트를 잔존치에 근접한 부위에 두 개를 식립하는 것이 계획되었으며, 가이드 수술을 통해 계획한 위치, 각도, 깊이에 식립되었다. 고정성 보철물 제작 과정은 상악 무치악 치아 배열 과정과 병행하여 예지성을 높였고, 국소의치를 제작 시에는 임플란트가 최후방 지대치로서 과도한 하중이 가하지 않도록 기능 운동을 허용하는 형태로 디자인되고, 이차 인상 과정을 거쳐 제작되었다. 각 치료 과정을 계획한대로 진행하여 환자와 술자 모두 심미적, 기능적으로 만족스러운 결과를 얻었기에 이를 보고하는 바이다.

상악 전치부에 발생한 이중치: 증례보고 (DOUBLE TEETH IN MAXILLARY PERMANENT INCISORS : CASE REPORTS)

  • 김미니;김영재;김정욱;장기택;김종철;한세현;이상훈
    • 대한소아치과학회지
    • /
    • 제36권1호
    • /
    • pp.119-125
    • /
    • 2009
  • 두 개의 치아가 하나로 붙은 것처럼 보이는 경우, 쌍생인지 융합인지 여부를 결정할 수 없을 경우에 이중치(double tooth)라는 용어를 사용한다. 이중치는 유치에 더 호발하나 영구치에도 약 0.1% 발생율을 보이며 심미적인 문제와 우식의 호발, 치주적 문제, 치열의 문제를 보일 수 있다. 이러한 이중치의 치료는 여러 전문 분야의 협진을 필요로 한다. 우선, 순측과 구개측의 중심구는 치아우식에 민감하므로 조기에 열구를 전색하는 것이 필요하며, 영구 치열에서는 융합치를 외과적으로 구강 내 또는 구강 외에서 분리한 후 교정적으로 배열할 수 있으며, 치관 모양을 다듬기 위하여 수복 치료가 필요할 수 있다. 한 개의 근관을 가진 경우는 순면구의 모양을 다듬고, 근원심 크기를 감소시킨 후 복합레진을 적용하는 방법도 있으나 불가피하게 발치해야 하는 경우도 있다. 이 경우 교정 및 보철 치료가 필요하며 임플란트 매식술도 고려된다. 그러나 이러한 치료의 선택은 임상적 상황에 맞추어 이루어져야한다. 이번 증례들에서도 심미적인 문제와 교합의 문제를 발견할 수 있었으며, 첫 번째 증례에서는 이런 문제를 해결하기 위하여 교정적, 근관치료, 레진 수복술, 외과적인 구강내 절제술을 이용하여 치료하였으나, 치근단 흡수가 관찰되었다. 두 번째와 세 번째 증례에서는 3차원 전산화 단층 촬영을 이용하여 정확한 치아의 내부와 외부 구조를 파악할 수 있었으며, 일반 방사선 사진으로는 판단이 어려운 근관 분리 여부와 근관의 융합 정도와 융합 위치 등을 진단할 수 있었다.

  • PDF

인상채득이 가능한 치유지대주를 이용한 임플란트 인상채득의 정확성 (Accuracy of the healing abutment and impression coping combined system on implant impression)

  • 전경배;이두형;김정한;황준호;박현위;이규복
    • 대한치과보철학회지
    • /
    • 제53권2호
    • /
    • pp.105-110
    • /
    • 2015
  • 목적: 새롭게 개발된 인상채득이 가능한 치유지대주를 이용한 인상채득과 기존의 임프레션 코핑을 이용한 인상채득을 3차원적으로 비교함으로써 개발된 시스템의 정확성을 평가하였다. 재료 및 방법: 10명의 환자에서 구치부에 임플란트(SuperLine; Dentium, Seoul, Korea)를 식립 후 치유지대주(MyHealing; Raphabio Co., Seoul, Korea)를 연결하였다. 식립 3개월 후 보철물 제작을 위한 인상채득시 인상채득이 가능한 치유지대주를 이용한 transfer 방식과 기존의 인상용 코핑을 이용한 pick-up 방식으로 두 번 인상채득 후 각각 주모형을 제작하였다. 맞춤형 보철 지대주(Myplant; Raphabio Co., Seoul, Korea)를 제작하고 각각의 주모형에 체결 후 치과용 스캐너(Scanner S600; Zirkonzahn, South Tyrol, Italy)로 가상의 모형을 형성하였다. 3차원 분석 프로그램(Geomagic Qualify 12; Geomagic, Morrisville, NC, USA)을 이용하여 두 개의 가상의 모형을 중첩하여 지대주의 위치와 기울기의 차이를 분석하였다. 측정값은 Kruskal Wallis과 Mann-Whitney U test 방법을 통해 분석하였고, 유의수준은 0.05 로 설정하였다. 결과: 두 가지 인상법에 따른 지대주의 위치는 근원심 방향에서 0.032 mm, 협설측 방향에서 0.029 mm, 상하 방향에서 0.023 mm의 차이를 보였다. 기울기는 근원심 방향에서 $0.755^{\circ}$, 협설측 방향에서 $1.275^{\circ}$, 상하 방향에서 $0.420^{\circ}$의 차이를 보였다. 결론: 인상채득이 가능한 치유지대주를 이용한 인상채득 방식은 기존의 전통적인 인상용 코핑을 이용한 방식과 비교 시 0.032 mm 이내의 차이를 보였고 기존 논문과의 비교 시 유사한 수치이다.

NiTi scissors-bite corrector의 와이어 굵기에 따른 3차원적 치아 이동 양상 (Three dimensional analysis of tooth movement using different sizes of NiTi wire on NiTi scissors-bite corrector)

  • 전현주;박선형;정상혁;전윤식
    • 대한치과교정학회지
    • /
    • 제39권1호
    • /
    • pp.43-53
    • /
    • 2009
  • 본 연구에서는 NiTi scissors-bite corrector를 세 가지 서로 다른 굵기 $0.018"{\times}0.025",\;0.016"{\times}0.022"$, 0.016"의 NiTi 와이어로 제작하였을 때 각각의 치아 이동 양상을 치아 이동 시뮬레이션 장치인 Calorific machine을 이용하여 3차원적으로 분석하고자 하였다. 가위교합에 이환된 상악 제2대구치 모형을 제작하고 제2소구치와 제1대구치 사이에 교정용 미니 임플랜트(orthodontic mini-implant)를 식립하여 제1대구치에 간접골성고정원을 설계하였다. 세 가지 굵기의 NiTi scissors-bite corrector를 부착하여 실험하였다. 치아의 이동 전후에 실험 모형은 computed tomography(CT)로 촬영하고 3차원 데이터로 변환하여 중첩하였다. 치아 이동 방향과 이동량을 계측하여, NiTi scissors-bite corrector 와이어 굵기에 따른 치아 이동 양상에 관한 통계적 유의성을 검정한 결과, 제2대구치 치관의 설측 이동량은 $0.018"{\times}0.025"$군(2.65 mm)이 가장 많았으며, 0.016"군(1.96 mm)과 통계적으로 유의한 차이를 보였다(p<0.05). 제2대구치 치관의 압하량은 $0.018"{\times}0.025"$군(2.35 mm), $0.016"{\times}0.022"$군(1.18 mm), 0.016"군(1.00 mm)으로 $0.018"{\times}0.025"$군이 나머지 두 군과 유의한 차이를 보였고(p<0.05), 치근의 압하량은 $0.018"{\times}0.025"$군(4.19 mm), $0.016"{\times}0.022"$군(3.29 mm), 0.016"군(2.24 mm)으로 세 군 간 모두 통계적 유의차를 보였다(p<0.05). 치아의 이동 양상을 관찰한 결과, 0.016"군에서는 제2대구치 치근의 협측 이동이 나타나지 않았다. 간접골성고정원으로 사용된 제1대구치의 고정원 소실은 0.2 mm 이하로 나타났다. 이상의 결과를 토대로 $0.018"{\times}0.025"$ NiTi 와이어로 제작한 NiTi scissors-bite corrector를 교정용 미니 임플랜트를 이용한 간접골성고정원과 함께 이용하였을 때, 최소한의 고정원의 소실과 함께 가장 큰 상악 제2대구치의 설측 이동 및 압하가 일어났다고 할 수 있다.