• Title/Summary/Keyword: simultaneous identification

Search Result 205, Processing Time 0.033 seconds

Volatile Flavor Components in Chinese Quince Fruits, Chaenomeles sinensis koehne (모과의 휘발성 Flavor 성분에 관한 연구)

  • Chung, Tae-Young;Cho, Dae-Sun;Song, Jae-Chul
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.176-187
    • /
    • 1988
  • Volatile flavor components in the Chinese quince fruits were trapped by simultaneous steam distillation-extraction method, and these were fractionated into the neutral, the basic, the phenolic and the acidic fraction. In the identification of carboxylic acids, the acidic fraction was methylated with diazomethane. Volatile flavor components in these fractions were analyzed by the high-resolution GC and GC-MS equipped with a fused silica capillary column. The total of one hundred and forty-five compounds from the steam volatile concentrate of the Chinese quince fruits were identified: they were 3 aliphatic hydrocarbons, 1 cyclic hydrocarbon, 4 aromatic hydrocarbons, 9 terpene hydrocarbons, 17 alcohols, 3 terpene alcohols, 6 phenols, 21 aldehydes, 7 ketones, 28 esters, 27 acids, 3 furans, 2 thiazoles, 2 acetals, 3 lactones and 9 miscellaneous ones. The greater part of the components except for carboxylic acids were identified from the neutral fraction. The neutral fraction gave a much higher yield than others and was assumed to be indispensable for the reproduction of the aroma of the Chinese quince fruits in a sensory evaluation. According to the results of the GC-sniff evaluation, 1-hexanal, cis-3-hexenal, trans-2-hexenal, 2-methyl-2-hepten-6-one, 1-hexanol, cis-3-hexenol, trans, trans-2, 4-hexadienal and trans-2-hexenol were considered to be the key compounds of grassy odor. On the other hand, esters seemed to be the main constituents of a fruity aroma in the Chinese quince fruits.

  • PDF

An Impact Assessment Index for the RFID Privacy (RFID 개인정보 영향평가지수 개발)

  • Han, Pil-Koo;Kang, Byung-Goo
    • Journal of Information Management
    • /
    • v.40 no.1
    • /
    • pp.69-86
    • /
    • 2009
  • The biggest paradigm of the latest telecommunications is ubiquitous computing. It is a technology basis to realize ubiquitous society that would affect social, economical and cultural industries with positive influence. However, there is a simultaneous concern that the approach to ubiquitous society may violate one's privacy. Therefore, the existence of legal and technological regulation would be the biggest obstacle in further RFID technology and industry dissemination. Also, in business side, they must invest with enormous expense and technology if technological method is only approached for the solution. As in the research, 8 RFID applications, application process and inspection items and 85 appraisal list of "An impact assessment for the privacy protection in RFID applications" developed by P. K. Han(2006), will be used as an indicator to measure RFID privacy impact assessment. In addition, it is to develop RFID privacy impact assessment index by applying objective data with survey of applied specialists. This would provide a data with feasibility and reliability to RFID related companies and able to utilize policy making on RFID private data. In addition, it is expected to contribute as an efficiency tool for individual data to build basis of ubiquitous society.

A Study on Characteristics of Atmospheric Heavy Metals in Subway Station

  • Kim, Chun-Huem;Yoo, Dong-Chul;Kwon, Young-Min;Han, Woong-Soo;Kim, Gi-Sun;Park, Mi-Jung;Kim, Young-Soon;Choi, Dal-Woong
    • Toxicological Research
    • /
    • v.26 no.2
    • /
    • pp.157-162
    • /
    • 2010
  • In this study, we investigated the atmospheric heavy metal concentrations in the particulate matter inside the subway stations of Seoul. In particular, we examined the correlation between the heavy metals and studied the effect of the heavy metals on cell proliferation. In six selected subway stations in Seoul, particulate matter was captured at the platforms and 11 types of heavy metals were analyzed. The results showed that the mean concentration of iron was the highest out of the heavy metals in particulate matter, followed by copper, potassium, calcium, zinc, nickel, sodium, manganese, magnesium, chromium and cadmium in that order. The correlation analysis showed that the correlations between the heavy metals was highest in the following order: (Cu vs Zn), (Ca vs Na), (Ca vs Mn), (Ni vs Cr), (Na vs Mn), (Cr vs Cd), (Zn vs Cd), (Cu vs Cd), (Ni vs Cd), (Cu vs Ni), (K vs Zn), (Cu vs K), (Cu vs Cr), (K vs Cd), (Zn vs Cr), (K vs Ni), (Zn vs Ni), (K vs Cr), and (Fe vs Cu). The correlation coefficient between zinc and copper was 0.937, indicating the highest correlation. Copper, zinc, nickel, chromium and cadmium, which are generated from artificial sources in general, showed correlations with many of the other metals and the correlation coefficients were also relatively high. The effect of the heavy metals on cell proliferation was also investigated in this study. Cultured cell was exposed to 10 mg/l or 100 mg/l of iron, copper, calcium, zinc, nickel, manganese, magnesium, chromium and cadmium for 24 hours. The cell proliferation in all the heavy metal-treated groups was not inhibited at 10 mg/l of the heavy metal concentration. The only exception to this was with the cadmium-treated group which showed a strong cell proliferation inhibition. This study provides the fundamental data for the understanding of simultaneous heavy metal exposure tendency at the time of particulate matter exposure in subway stations and the identification of heavy metal sources. Moreover, this study can be used as the fundamental data for the cell toxicity study of the subway-oriented heavy metal-containing particulate matter.

Model-Based Approach to Flight Test System Development to Cope with Demand for Simultaneous Guided Missile Flight Tests (동시다발적인 유도무기 비행시험 수요에 대응하기 위한 모델기반 비행시험 시스템 개발)

  • Park, Woong;Lee, Jae-Chon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.268-277
    • /
    • 2019
  • Flight test systems should monitor various conditions in real time during flight tests and take safety measures in an emergency. The importance of ensuring test safety increases in more complicated and wider test environments. Also, due to the transition of wartime operational authority, many guided missile systems must be developed simultaneously. Early deployment and budget reduction by shortening the development and T&E periods are also necessary. Consequently, the risk of flight tests under the circumstance of inefficient test resources is increasing. To address this deficiency, a flight test system model using SysML was proposed in this study. The method of designing and verifying the test system is based on the agile shift left testing methodology of advanced T&E labs and utilizing a system reference model in the aerospace field. Through modeling and simulation analysis, early identification and correction of faults resulting from inconsistent test requirements can mitigate the risk of delays during the T&E phase of flight tests. Also, because the flight test system model was constructed using SysML, it can be applied to test various guided missile systems.

A Ship-Wake Joint Detection Using Sentinel-2 Imagery

  • Woojin, Jeon;Donghyun, Jin;Noh-hun, Seong;Daeseong, Jung;Suyoung, Sim;Jongho, Woo;Yugyeong, Byeon;Nayeon, Kim;Kyung-Soo, Han
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.1
    • /
    • pp.77-86
    • /
    • 2023
  • Ship detection is widely used in areas such as maritime security, maritime traffic, fisheries management, illegal fishing, and border control, and ship detection is important for rapid response and damage minimization as ship accident rates increase due to recent increases in international maritime traffic. Currently, according to a number of global and national regulations, ships must be equipped with automatic identification system (AIS), which provide information such as the location and speed of the ship periodically at regular intervals. However, most small vessels (less than 300 tons) are not obligated to install the transponder and may not be transmitted intentionally or accidentally. There is even a case of misuse of the ship'slocation information. Therefore, in this study, ship detection was performed using high-resolution optical satellite images that can periodically remotely detect a wide range and detectsmallships. However, optical images can cause false-alarm due to noise on the surface of the sea, such as waves, or factors indicating ship-like brightness, such as clouds and wakes. So, it is important to remove these factors to improve the accuracy of ship detection. In this study, false alarm wasreduced, and the accuracy ofship detection wasimproved by removing wake.As a ship detection method, ship detection was performed using machine learning-based random forest (RF), and convolutional neural network (CNN) techniquesthat have been widely used in object detection fieldsrecently, and ship detection results by the model were compared and analyzed. In addition, in this study, the results of RF and CNN were combined to improve the phenomenon of ship disconnection and the phenomenon of small detection. The ship detection results of thisstudy are significant in that they improved the limitations of each model while maintaining accuracy. In addition, if satellite images with improved spatial resolution are utilized in the future, it is expected that ship and wake simultaneous detection with higher accuracy will be performed.

Analysis Method of Surfactants for Identification of Residue Dishwashing Detergent (세척제 잔류량 확인을 위한 계면활성제 분석법 확립)

  • Park, Na-Youn;Lee, Sojeong;Kim, Jung Hoan;Kho, Younglim
    • Journal of the Korean Chemical Society
    • /
    • v.65 no.6
    • /
    • pp.433-440
    • /
    • 2021
  • Surfactants are organic compounds that have both hydrophilic and non-polar parts in one molecule, classified as non-ion, anion, cation, and amphoteric surfactants according to the charge of hydrophilic parts in aqueous state. A trace amounts may remain when vegetables and fruits are washed using type1 detergent (Vegetable and fruit detergent), and there is a possibility of exposure to the human body through ingestion. This study developed the simultaneous analysis method for 5 surfactants with LC-MS/MS for analysis of detergent residues after washing vegetables and fruits with detergent. The mobile phase used distilled water and acetonitrile containing 50 mM ammonium formate and 0.1% formic acid and was analyzed using a gradient method using XBridge BEH C8 column. The accuracy of the established method was 83.9-112.1%, and the precision was less than 20%. The detection limit was 7.0 (SLS) to 29.0 (SLES-N3) ㎍/L, and the correlation coefficient (r2) of calibration line regression was greater than 0.99, it is considered suitable for the analysis of trace amounts of surfactant components remaining in vegetables and fruits.

Roadmapping technique in the hybrid operating room for the microsurgical treatment of complex intracranial aneurysms

  • Juan Luis Gomez-Amador;Cristopher G Valencia-Ramos;Marcos Vinicius Sangrador-Deitos;Aldo Eguiluz-Melendez;Gerardo Y Guinto-Nishimura;Alan Hernandez-Hernandez;Samuel Romano-Feinholz;Luis Alberto Ortega-Porcayo;Sebastian Velasco-Torres;Jose J Martinez-Manrique;Juan Jose Ramirez-Andrade;Marco Zenteno-Castellanos
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.1
    • /
    • pp.50-61
    • /
    • 2023
  • Objective: To describe the roadmapping technique and our three-year experience in the management of intracranial aneurysms in the hybrid operating room. Methods: We analyzed all patients who underwent surgical clipping for cerebral aneurysms with the roadmapping technique from January 2017 to September 2019. We report demographic, clinical, and morphological variables, as well as clinical and radiological outcomes. We further describe three illustrative cases of the technique. Results: A total of 13 patients were included, 9 of which (69.2%) presented with subarachnoid hemorrhage, with a total of 23 treated aneurysms. All patients were female, with a mean age of 47.7 years (range 31-63). All cases were anterior circulation aneurysms, the most frequent location being the ophthalmic segment of the internal carotid artery (ICA) in 11 cases (48%), followed by posterior communicating in 8 (36%), and ICA bifurcation in 2 (8%). Intraoperative clip repositioning was required in 9 aneurysms (36%) as a result of the roadmapping technique in the hybrid operating room. There were no residual aneurysms in our series, nor reported mortality. Conclusions: The roadmapping technique in the hybrid operating room offers a complementary tool for the adequate occlusion of complex intracranial aneurysms, as it provides a real time fluoroscopic-guided clipping technique, and clip repositioning is possible in a single surgical stage, whenever a residual portion of the aneurysm is identified. This technique also provides some advantages, such as immediate vasospasm identification and treatment with intra-arterial vasodilators, balloon proximal control for certain paraclinoid aneurysms, and simultaneous endovascular treatment in selected cases during a single stage.

Development and Validation of Multiplex Polymerase Chain Reaction to Determine Squid Species Based on 16s rRNA Gene (오징어류 종 판별을 위한 다중 유전자 검사법 개발 및 검증)

  • Kim, Hyunsu;Seo, Yong Bae;Choi, Seong-Seok;Kim, Jin-Hee;Shin, Jiyoung;Yang, Ji-Young;Kim, Gun-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.1
    • /
    • pp.43-50
    • /
    • 2015
  • In this study, single PCR and multiplex PCR tests were examined for identification of four types of squid species (giant squid, cuttlefish, octopus, beka squid) purchased from fish market as well as aquatic processed products in Busan. To design the specific primers against each species, the nucleotide sequences of the mitochondrial 16s rRNA gene of Architeuthis dux, Todarodes pacificus, Enteroctopus dofleini, Enteroctopus megalocyathus, Uroteuthis chinensis, Uroteuthis duvauceli, Uroteuthis edulis groups were analyzed for the identification of each species registered in the GeneBank (www.ncbi.nlm.nih.gov) and have been used for comparative analysis. In order to obtain the size variation of amplified fragments on multiplex PCR, we designed KOJ-F, OJ-F, OCT-F, HAN-F, ALLR primers for each species. The optimal PCR conditions and primers were selected for four types of squid species to determine target base sequences in its PCR products. In the case of single PCR, giant squid was only amplified by KOJ-F/ALLR primer; cuttlefish was only amplified by OJ-F/ALLR primer; octopus was only amplified by OCT-F/ALLR primer; and beka squid was only amplified by HAN-F/ALLR primer. For multiplex PCR, the mixture of four kinds of genomic DNA (giant squid, cuttlefish, octopus, beka squid) been prepared as a template and used together with the mixture of KOJ-F/OJ-F/OCT-F/HAN-F/ALLR primers in the reaction. By the multiplex PCR, it is confirmed that four samples are correspond to multiple simultaneous amplicon. Finally, we validated the established methods of multiplex PCR in the aquatic processed products. Although the mitochondrial 16s rRNA primers used in this study was useful as a marker for detection of each species among them, the study indicated that the established multiplex PCR method can be more useful tool for monitoring the processed products.

Determination of methamphetamine, 4-hydroxymethamphetamine, amphetamine and 4-hydroxyamphetamine in urine using dilute-and-shoot liquid chromatography-tandem mass spectrometry (시료 희석 주입 LC-MS/MS를 이용한 소변 중 메스암페타민, 4-하이드록시메스암페타민, 암페타민 및 4-하이드록시암페타민 동시 분석)

  • Heo, Bo-Reum;Kwon, NamHee;Kim, Jin Young
    • Analytical Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.161-170
    • /
    • 2018
  • The epidemic of disorders associated with synthetic stimulants, such as methamphetamine (MA) and amphetamine (AP), is a health, social, legal, and financial problem. Owing to the high potential of their abuse and addiction, reliable analytical methods are required to detect and identify MA, AP, and their metabolites in biological samples. Thus, a dilute-and-shoot liquid chromatography-tandem mass spectrophotometry (LC-MS/MS) was developed for simultaneous determination of MA, 4-hydroxymethamphetamine (4HMA), AP, and 4-hydroxyamphetamine (4HA) in urine. Urine sample ($100{\mu}L$) was mixed with $50{\mu}L$ of mobile phase consisting of 0.4 % formic acid and methanol and $50{\mu}L$ of working internal-standard solution. Aliquots of $8{\mu}L$ diluted urine was injected into the LC-MS/MS system. For all analytes, chromatographic separation was performed using a C18 reversed-phase column with gradient elution and a total run time of 5 min. The identification and quantification were performed by multiple reaction monitoring (MRM). Linear least-squares regression was conducted to generate a calibration curve, with $1/x^2$ as the weighting factor. The linear ranges were 2.0-200, 1.0-800, and 10-2500 ng/mL for 4HA and 4HMA, AP, and MA, respectively. The inter- and intraday precisions were within 6.6 %, whereas the inter- and intraday accuracies ranged from -14.9 to 11.3 %. The low limits of quantification were 2.0 ng/mL (4HA and 4HMA), 1.0 ng/mL (AP), and 10 ng/mL (MA). The proposed method exhibited satisfactory selectivity, dilution integrity, matrix effect, and stability, which are required for validation. Moreover, the purification efficiency of high-speed centrifugation was clearly higher than 6-15 % for QC samples (n=5), which was higher than that of the membrane-filtration method. The applicability of the proposed method was tested by forensic analysis of urine samples from drug abusers.

Visualization and Localization of Fusion Image Using VRML for Three-dimensional Modeling of Epileptic Seizure Focus (VRML을 이용한 융합 영상에서 간질환자 발작 진원지의 3차원적 가시화와 위치 측정 구현)

  • 이상호;김동현;유선국;정해조;윤미진;손혜경;강원석;이종두;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.34-42
    • /
    • 2003
  • In medical imaging, three-dimensional (3D) display using Virtual Reality Modeling Language (VRML) as a portable file format can give intuitive information more efficiently on the World Wide Web (WWW). The web-based 3D visualization of functional images combined with anatomical images has not studied much in systematic ways. The goal of this study was to achieve a simultaneous observation of 3D anatomic and functional models with planar images on the WWW, providing their locational information in 3D space with a measuring implement using VRML. MRI and ictal-interictal SPECT images were obtained from one epileptic patient. Subtraction ictal SPECT co-registered to MRI (SISCOM) was performed to improve identification of a seizure focus. SISCOM image volumes were held by thresholds above one standard deviation (1-SD) and two standard deviations (2-SD). SISCOM foci and boundaries of gray matter, white matter, and cerebrospinal fluid (CSF) in the MRI volume were segmented and rendered to VRML polygonal surfaces by marching cube algorithm. Line profiles of x and y-axis that represent real lengths on an image were acquired and their maximum lengths were the same as 211.67 mm. The real size vs. the rendered VRML surface size was approximately the ratio of 1 to 605.9. A VRML measuring tool was made and merged with previous VRML surfaces. User interface tools were embedded with Java Script routines to display MRI planar images as cross sections of 3D surface models and to set transparencies of 3D surface models. When transparencies of 3D surface models were properly controlled, a fused display of the brain geometry with 3D distributions of focal activated regions provided intuitively spatial correlations among three 3D surface models. The epileptic seizure focus was in the right temporal lobe of the brain. The real position of the seizure focus could be verified by the VRML measuring tool and the anatomy corresponding to the seizure focus could be confirmed by MRI planar images crossing 3D surface models. The VRML application developed in this study may have several advantages. Firstly, 3D fused display and control of anatomic and functional image were achieved on the m. Secondly, the vector analysis of a 3D surface model was defined by the VRML measuring tool based on the real size. Finally, the anatomy corresponding to the seizure focus was intuitively detected by correlations with MRI images. Our web based visualization of 3-D fusion image and its localization will be a help to online research and education in diagnostic radiology, therapeutic radiology, and surgery applications.

  • PDF