• Title/Summary/Keyword: simultaneous diagnosis

Search Result 161, Processing Time 0.032 seconds

Thermal-hydraulic safety analysis of radioisotope production in HANARO using MCNP6 and COMSOL multiphysics: A feasibility study

  • Taeyun Kim;Bo-Young Han;Seongwoo Yang;Jaegi Lee ;Gwang-Min Sun;Byung-Gun Park;Sung-Joon Ye
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.3996-4001
    • /
    • 2023
  • The High-flux Advanced Neutron Application Reactor (HANARO) produces radioisotopes (RIs) (131I, 192Ir, etc.) through neutron irradiation on various RI production targets. Among them, 177Lu and 166Ho are particularly promising owing to their theranostic characteristics that facilitate simultaneous diagnosis and treatment. Prior to neutron irradiation, evaluating the nuclear heating of the RI production target is essential for ensuring the thermal-hydraulic safety of HANARO. In this study, the feasibility of producing 177Lu and 166Ho using irradiation holes of HANARO was investigated in terms of thermal-hydraulic safety. The nuclear heating rates of the RI production target by prompt and delayed radiation were calculated using MCNP6. The calculated nuclear heating rates were used as an input parameter in COMSOL Multiphysics to obtain the temperature distribution in an irradiation hole. The degree of temperature increase of the 177Lu and 166Ho production targets satisfied the safety criteria of HANARO. The nuclear heating rates and temperature distribution obtained through the in silico study are expected to provide valuable insight into the production of 177Lu and 166Ho using HANARO.

Diagnostic Usefulness of Simultaneous Measurement of Serum Tumor Markers in Lung Cancer Patients (폐암환자 혈청에서 CEA, SCC Ag, NSE 동시 측정의 진단적 의의)

  • Jang, Tae-Won;Jung, Man-Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.3
    • /
    • pp.322-331
    • /
    • 1995
  • Introduction: This study was performed to evaluate the diagnostic usefulness of simultaneous determination of 3 tumor markers {serum carcinoembryonic antigen(CEA), squamous cell carcinoma antigen (SCC Ag) and neuron specific enolase(NSE)} in lung cancer patients. Method: In 113 patients with primary lung cancer(70 with squamous cell carcinoma, 30 with adenocarcinoma, 13 with small cell carcinoma) and 103 patients with benign lung diseases, serum CEA and NSE were measured by enzyme immunoassay, and SCC Ag was measured by microparticle enzyme immunoassay. Results: 1) The mean serum levels of 3 tumor markers were significantly higher in lung cancer groups than benign lung disease groups respectively(p=0.001). 2) In squamous cell carcinoma, the SCC Ag was elevated in 67%, in adenocarcinoma CEA was elevated in 77% and in small cell carcinoma NSE was elevated in 77%, but there were no significant differences according to the stage of each cancer cell types. 3) CEA was the most sensitive marker, but nonspecific to cancer types. SCC Ag was less sensitive than other markers, but more specific toward squamous cell carcinoma, and NSE was more specific to primary lung cancer. 4) As the number of positive tumor markers was increased, the relative possibility of lung cancer was also increased. If two markers were positive, it increased to 77%, and if three markers were positive it increased to 90%. Conclusion: The simultaneous measurement of serum CEA, SCC Ag and NSE would provide additional information for the diagnosis of lung cancer.

  • PDF

Diagnostic Performance of Routine Objective Tests and Cost-Effective Approach for Chronic Cough (만성 기침의 진단 성적과 경제적 접근 모델)

  • Jeon, Gang;Jang, Seung Hun;Song, Hae Geun;Ha, Jun-Wook;Eom, Kwang-Seok;Bahn, Joon-Woo;Kim, Dong-Gyu;Shin, Tae Rim;Park, Sang Myon;Park, Yong Bum;Kim, Chul-Hong;Hyun, In-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.6
    • /
    • pp.535-542
    • /
    • 2004
  • Background : Despite the clinical clues of bronchial asthma, some chronic coughers fail to be diagnosed due to negative test results. This study was aimed at evaluating the diagnostic performance of routine objective tests and identifying a cost-effective approach for asthmatics with a chronic cough. Methods : Patients with a chronic cough of more than 3 weeks duration, and showing normal chest radiograph and spirometry were enrolled. On the first visit, objective tests, composed of serum total IgE, peripheral blood eosinophil count, spontaneous sputum eosinophil count, methacholine bronchial provocation test (MBPT) and paranasal sinus radiograph, were performed, with the simultaneous administration of oral prednisolone (0.5mg/kg) for one week. The final diagnoses were made on the basis of the test results, and the patients grouped according to their steroid responsiveness. The role of the etiologic diagnosis tests was evaluated, and the medical costs of the final management plan simulated with respect to three assumed models. Results : Sixty chronic coughers were finally analyzed. The final diagnoses were as follows: bronchial asthma 21.7%, eosinophilic bronchitis 6.7%, paranasal sinusitis 18.3%, presumptive allergy 8.3% and non-diagnostic case 45.0%. Ninety percent were steroid responder. With the bronchial asthma cases, the positive rate of MBPT was 38.5%, with sputum eosinophil count in 84.6%, serum total IgE in 38.5%, and a peripheral blood eosinophil count rate of 30.8%. When the test results and steroid responsiveness data were applied to the 3 models, the chest radiograph, spirometry, sputum eosinophil count and paranasal sinus radiograph test results, and simultaneous short term steroid treatment seemed to have acceptable diagnostic performances, which could be used as a further guide to cost-effective planning. Conclusion : Objective tests, composed of chest radiograph, spirometry, paranasal sinus radiograph and sputum eosinophil count, with simultaneous short term steroid treatment, are suggested as cost-effective approaches for asthmatics with a chronic cough.

Performance of the BacT Alert 3D System Versus Solid Media for Recovery and Drug Susceptibility Testing of Mycobacterium tuberculosis in a Tertiary Hospital in Korea

  • Kim, Seoung-Cheol;Jeon, Bo-Young;Kim, Jin-Sook;Choi, In Hwan;Kim, Jiro;Woo, Jeongim;Kim, Soojin;Lee, Hyeong Woo;Sezim, Monoldorova;Cho, Sang-Nae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.79 no.4
    • /
    • pp.282-288
    • /
    • 2016
  • Background: Tuberculosis (TB) is a major health problem, and accurate and rapid diagnosis of multidrug-resistant (MDR) and extended drug-resistant (XDR) TB is important for appropriate treatment. In this study, performances of solid and liquid culture methods were compared with respect to MDR- and XDR-TB isolate recovery and drug susceptibility testing. Methods: Sputum specimens from 304 patients were stained with Ziehl-Neelsen method. Mycobacterium tuberculosis (Mtb) isolates were tested for recovery on $L{\ddot{o}wenstein$-Jensen (LJ) medium and the BacT Alert 3D system. For drug susceptibility testing of Mtb, isolates were evaluated on M-KIT plates and the BacT Alert 3D system. Results: The recovery rates were 94.9% (206/217) and 98.2% (213/217) for LJ medium and the BacT Alert 3D system, respectively (kappa coefficient, 0.884). The rate of drug resistance was 13.4% for at least one or more drugs, 6.0% for MDR-TB and 2.3% for XDR-TB. M-KIT plate and BacT 3D Alert 3D system were comparable in drug susceptibility testing for isoniazid (97.7%; kappa coefficient, 0.905) and rifampin (98.6%; kappa coefficient, 0.907). Antibiotic resistance was observed using M-KIT plates for 24 of the total 29 Mtb isolates (82.8%). Conclusion: The liquid culture system showed greater reduction in the culture period, as compared with LJ medium; however, drug susceptibility testing using M-KIT plates was advantageous for simultaneous testing against multiple drug targets.

The Importance of Septoplasty in The Treatment of Nasal Bone and Grade I Septal Fracture: Estimation with Acoustic Rhinometry (비중격 골절을 동반한 단순 비골 골절의 치료에 있어 비중격 교정술의 중요성: 비강 통기도 검사를 이용한 평가)

  • Kim, Jun-Hyung;Shin, Dong-Woo;Choi, Tae-Hyun;Son, Dae-Gu;Han, Ki-Hwan
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.626-632
    • /
    • 2010
  • Purpose: Nasal bone fractures are often classified as minor injury. However, the incidence of posttraumatic nasal deformity remains alarmingly high. It is because of unnoticed septal fracture. This study was conducted to determine the necessity of septoplasty for patients with nasal bone fracture accompanying grade I septal fractures. Methods: Among 105 patients with nasal bone fractures, 52 who had grade I septal fracture were diagnosed based on physical examination and computed tomography. Patients' age ranged from 14 to 65 years (mean 29.25 years), and 35 were male and 17 female. Patients were divided into 2 groups according to surgical treatment methods: patients who underwent closed reduction only (group 1, n=28) and those who underwent simultaneous closed reduction and septoplasty (group 2, n=24). The treatment outcomes were evaluated by comparing changes in nasal airway volume measured by acoustic rhinometry before the surgery, 3 months and 6 months after the surgery according to the timing of surgical repair and surgical treatment methods. Results: Nasal airway volume increased after the surgery by 17.8% in 3 months after the surgery, 25.2% in 6 months in group 1 and by 22.7% in 3 months, 35.8% in 6 months in group 2. The increase in airway volume after the surgery by 26.3% in 3 months after the surgery, 34.2% in 6 months after the surgery in operation within 1 week after trauma and by 12.1% in 3 months, 22.2% in 6 months after the operation later 1 week after trauma. The difference was statistically significant. Three patients in group 1 complained of intermittent nasal obstruction, two of whom showed a decrease in nasal airway volume by acoustic rhinometry. Conclusion: Most patients with nasal bone fractures accompanying grade I septal fractures have been treated with closed reduction in clinical settings. However, the results of this study suggest that septoplasty be performed after a correct diagnosis of septal fracture is made through comprehensive physical examination and computed tomography. Septoplasty is important to obtain more favorable outcomes and reduce complication.

Practicability Assessment of Spherical Mechanical Check Device(SMCD) (Mechanical Check용 Spherical device의 제작 및 특성 평가)

  • Lee, Byung-Koo;Yang, Dae-Sik;Kweon, Young-Ho;Ko, Shin-Gwan;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.153-159
    • /
    • 2007
  • Digital medical image commenced with an introduction of PACS has become more popular today in the radiation diagnosis and radiation treatment and made great progress, in particular, for medical testing field, whereas it has made slow progress for radiation treatment field. In order to accommodate the current trend of digital from analog, a spherical mechanical check device(SMCD) that is the form of spherical differing from the existing form of flat or cube has been designed and tested its practicability to replace the part in mechanical check with digital image from QA operation. If the distance maintains constance between source(target) and image detector with constant distance to the center of spherical mechanical check device(SMCD), the size will be shown as a constant image at all times regardless of its direction exposed. For the test, two accurate hemispheres are made and put together which results in a sphere of the equilateral circle. It enables a variety of implementation of the existing mechanical check using digital image as follows: congruity level of radiation field and light field, size accuracy of radiation field and collimation field, gantry rotation isocenter check, collimation rotation isocenter check, room laser accuracy check, collimation rotation angle check, couch rotation angle check, and more. In addition, it has proved its practicability in checking isocenter congruity level as real time at the time of simultaneous rotation between gantry and couch that is applied to the non-coplanar field, which had been hard to apply as a device formed of existing flat or cube.

  • PDF

Real-time Nucleic Acid Sequence Based Amplification (Real-time NASBA) for Detection of Norovirus

  • Lee, In-Soo;Choi, Dong-Hyuk;Lim, Jae-Won;Cho, Yoon-Jung;Jeong, Hye-Sook;Cheon, Doo-Sung;Bang, Hye-Eun;Jin, Hyun-Woo;Choi, Yeon-Im;Park, Sang-Jung;Kim, Sung-hyun;Lee, Hye-Young;Kim, Tae-Ue
    • Biomedical Science Letters
    • /
    • v.17 no.3
    • /
    • pp.191-196
    • /
    • 2011
  • Noroviruses (noroV) are the major cause of nonbacterial gastroenteritis in humans worldwide. Since noroV cannot yet be cultured in vitro and their diagnosis by electron microscopy requires at least $10^6$ viral particles/g of stool a variety of molecular detection techniques represent an important step towards the detection of noroV. In the present study, we have applied real-time nucleic acid sequence-based amplification (real-time NASBA) for simultaneous detection of NoroV genogroup I (GI) and genogroup II (GII) using standard viral RNA. For real-time NASBA assay which can detected noroV GI and GII, a selective region of the genes encoding the capsid protein was used to design primers and genotype-specific molecular beacon probes. The specificity of the real-time NASBA using newly designed primers and probes were confirmed using standard viral RNA of noroV GI and GII. To determine the sensitivity of this assay, serial 10-fold dilutions of standard viral RNA of noroV GI and GII were used for reverse transcription polymerase chain reaction (RT-PCR) and real-time NASBA. The results showed that while agarose gel electrophoresis could detect RT-PCR products with 10 pg of standard viral RNA, the real-time NASBA assay could detect 100 fg of standard viral RNA. These results suggested that the real-time NASBA assay has much higher sensitivity than conventional RT-PCR assay. This assay was expected that might detect the viral RNA in the specimens which could have been false negative by RT-PCR. There were needed to perform real-time NASBA with clinical specimens for evaluating accurate sensitivity and specificity of this assay.

Practicability Assessment of Spherical Type Mechanical Check Device (SMCD) (Mechanical Check용 Spherical Device의 제작 및 특성 평가)

  • Lee, Byung-Koo;Kim, Gun-Oh;Kweon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.55-62
    • /
    • 2007
  • Purpose: Digital medical image commenced with an introduction of PACS has become more popular today in the radiation diagnosis and medical treatment and made great progress, in particular, for medical testing field, whereas it has made slow progress for radiation therapy area. In order to accommodate the current trend of digital from analog, a spherical type mechanical check device (SMCD) that is form of spherical differing from the existing form of flat or cube has been designed and tested its practicability to replace the part in mechanical check with digital image from QA operation. Materials and Methods: If the distance maintains constant between source(target) and image detector with constant distance to the center of spherical type mechanical check device(SMCD), the size will be shown as a constant image at all times regardless of its direction exposed. For the test, two accurate hemispheres are made and put together which results in a sphere of the equilateral circle. Results: It enables a variety of implementation of the existing mechanical check using digital image as follows: congruity level of radiation field and light field, size accuracy of radiation field and collimation field, gantry rotation isocenter check, collimation rotation isocenter check, room laser accuracy check, collimation rotation angle check, couch rotation angle check, and more. Conclusion: It has proved its practicability in checking isocenter congruity level as real time at the time of simultaneous rotation between gantry and couch that is applied to the non-coplanar field, which had been hard to apply as a device formed of existing flat or cube.

  • PDF

Multi-tracer Imaging of a Compton Camera (다중 추적자 영상을 위한 컴프턴 카메라)

  • Kim, Soo Mee
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.18-27
    • /
    • 2015
  • Since a Compton camera has high detection sensitivity due to electronic collimation and a good energy resolution, it is a potential imaging system for nuclear medicine. In this study, we investigated the feasibility of a Compton camera for multi-tracer imaging and proposed a rotating Compton camera to satisfy Orlov's condition for 3D imaging. Two software phantoms of 140 and 511 keV radiation sources were used for Monte-Carlo simulation and then the simulation data were reconstructed by listmode ordered subset expectation maximization to evaluate the capability of multi-tracer imaging in a Compton camera. And the Compton camera rotating around the object was proposed and tested with different rotation angle steps for improving the limited coverage of the fixed conventional Compton camera over the field-of-view in terms of histogram of angles in spherical coordinates. The simulation data showed the separate 140 and 511 keV images from simultaneous multi-tracer detection in both 2D and 3D imaging and the number of valid projection lines on the conical surfaces was inversely proportional to the decrease of rotation angle. Considering computation load and proper number of projection lines on the conical surface, the rotation angle of 30 degree was sufficient for 3D imaging of the Compton camera in terms of 26 min of computation time and 5 million of detected event number and the increased detection time can be solved with multiple Compton camera system. The Compton camera proposed in this study can be effective system for multi-tracer imaging and is a potential system for development of various disease diagnosis and therapy approaches.

Unusual MR Features of Extravasation of Contrast Material in Hyperacute Intracerebral Hemorrhage (초급성 두개내 출혈 환자에서 조영제의 혈관외 누출을 동반한 비전형적 자기공명영상)

  • Choi Seung Hong;Chun Woo Sun;Kim Ji-Hoon;Kang Hyun Seung;Kwon Bae Ju;Na Dong Gyu;Kim Jae Hyung;Han Moon Hee;Chang Kee-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.50-56
    • /
    • 2005
  • Contrast extravasation in hyperacute intracerebral hemorrhage (ICH) indicative of active bleeding is a predictor of possible enlargement of hematoma, providing clinician with valid management decisions. We report unusual MR imaging features of contrast extravasation in hyperacute ICH in three patients: Case 1 with hypertension revealed dual foci of contrast extravasation, one in right basal ganglia and the other in left lateral ventricle, suggesting simultaneous bleeding of the two foci. Case 2 with presumed diagnosis of vasculitis showed relatively large area of contrast extravasation mimicking enhancing tumor or vascular lesion. Case 3 with hypertension showed the findings of active bleeding which was likely to occur during the time of MR imaging acquisition.

  • PDF