• 제목/요약/키워드: simulated canal

검색결과 92건 처리시간 0.024초

Effects of different calcium-silicate based materials on fracture resistance of immature permanent teeth with replacement root resorption and osteoclastogenesis

  • Gabriela Leite de Souza;Gabrielle Alves Nunes Freitas;Maria Tereza Hordones Ribeiro;Nelly Xiomara Alvarado Lemus;Carlos Jose Soares;Camilla Christian Gomes Moura
    • Restorative Dentistry and Endodontics
    • /
    • 제48권2호
    • /
    • pp.21.1-21.15
    • /
    • 2023
  • Objectives: This study evaluated the effects of Biodentine (BD), Bio-C Repair (BCR), and mineral trioxide aggregate (MTA) plug on the fracture resistance of simulated immature teeth with replacement root resorption (RRR) and in vitro-induced osteoclastogenesis. Materials and Methods: Sixty bovine incisors simulating immature teeth and RRR were divided into 5 groups: BD and BCR groups, with samples completely filled with the respective materials; MTA group, which utilized a 3-mm apical MTA plug; RRR group, which received no root canal filling; and normal periodontal ligament (PL) group, which had no RRR and no root canal filling. All the teeth underwent cycling loading, and compression strength testing was performed using a universal testing machine. RAW 264.7 macrophages were treated with 1:16 extracts of BD, BCR, and MTA containing receptor activator of nuclear factor-kappa B ligand (RANKL) for 5 days. RANKL-induced osteoclast differentiation was assessed by staining with tartrate-resistant acid phosphatase. The fracture load and osteoclast number were analyzed using 1-way ANOVA and Tukey's test (α = 0.05). Results: No significant difference in fracture resistance was observed among the groups (p > 0.05). All materials similarly inhibited osteoclastogenesis (p > 0.05), except for BCR, which led to a lower percentage of osteoclasts than did MTA (p < 0.0001). Conclusions: The treatment options for non-vital immature teeth with RRR did not strengthen the teeth and promoted a similar resistance to fractures in all cases. BD, MTA, and BCR showed inhibitory effects on osteoclast differentiation, with BCR yielding improved results compared to the other materials.

학생들이 사용한 엔진 구동형 Ni-Ti file systems의 근관 성형 효율 비교 (COMPARISON OF SHAPING ABILITY OF ROTARY Ni-Ti FILE SYSTEMS USED BY UNDERGRADUATES)

  • 강문성;김현철;허복;박정길
    • Restorative Dentistry and Endodontics
    • /
    • 제31권1호
    • /
    • pp.1-10
    • /
    • 2006
  • 본 연구의 목적은 학생들이 사용한 세 가지 Ni-Ti파일의 성형효율을 비교하고, 각 파일의 사용 경험 유무에 따른 차이를 비교하여 치과대학생을 위한 교육에 적합한 종류를 선택하는데 도움을 얻고자하는 것이다. Ni-Ti파일 사용 경험이 없는 학생 50명과 Ni-Ti파일을 사용한 근관치료 경력이 2년 이상인 경험자 10명이 세 종류의 Ni-Ti file - $ProFile^{(R)}\;(PF),\;HeroShaper^{(R)}\;(HS),\;K3^{TM}\;(K3)$ -을 사용하여 180개의 근관 모형을 성형하였다. 근관성형 시간 및 기구 변형, 근관 이형성을 조사하고 성형 전후 상을 중첩하여 근관 삭제폭, 근관변위량과 중심변위율을 1, 3. 5 mm에서 분석하였다. 1. 근관 성형시간은 HS군이 가장 빨랐으며, 총 삭제 량은 모든 지점에서 K3군이 다른 군보다 컸다 (P<0.05) . 2. 세 군 모두 1, 3 mm에서 외측 변이를 보였고, 1 mm지점에서 PF군이 가장 안정적이었다 (P<0.05). 3. 중심변위율은 1, 3 mm에서 HS, PF군이 K3군보다 작았다. 5 mm지점에서는 PF군이 가장 작았고, PF군 3 mm에서 학생은 경험자보다 유의하게 작았다 (P<0.05).

CIC형 보청기용 범용 이어쉘 제작을 위한 파라미터 추출 및 시뮬레이션 (Parameter Extraction and Simulation in order to Manufacture Ready-made Ear Shell for CIC Type Hearing Aids)

  • 에르덴바야르;전유용;박규석;송영록;이상민
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권4호
    • /
    • pp.321-327
    • /
    • 2010
  • Most of the ear shells of hearing aids are manufactured manually, and it is one of the reasons that the cost of the custom-made hearing aids can be increased. Thus it is required to manufacture the ready-made ear shell for the purpose of easy manufacturing and decrease in cost. In this study, we extract parameters in order to manufacture the ready-made ear shell for CIC type hearing aids and simulate to reconstruct the ear shell using the extracted parameters. To parameter extraction, we set up the eleven parameters for the ready-made ear shell based on anatomical characteristics of the ear canal, and we found values of the parameters from twenty-one impressions in their 20s and twelve impressions in their 60s using aperture detection and feature detection algorithms. Classifying the parameters by size, we also determine the parameters of ready-made ear shell into three types for people in their 20s and two types for people in their 60s. Each ready-made ear shell was simulated to reconstruct using figured parameters, and evaluated the rate of agreement with unused impressions for setting parameters. To evaluate the ready-made ear shell, we calculate the volume ratio and intersection between of the each impression and ready-made ear shell, and the intersection ratio using the intersection volume and ready-made ear shell volume. As a result, the volume ratio was about 70%, and volume match ratio was also up to 70%. It means that the ready-made ear shell we simulated is the significantly matched to impression.

수치해석을 이용한 FPSO용 사류펌프 성능해석 연구 (A Numerical Study on the Performance Analysis of the Mixed Flow Pump for FPSO)

  • 강경원;김영훈;김영주;우남섭;권재기;윤명오
    • 한국유체기계학회 논문집
    • /
    • 제14권5호
    • /
    • pp.12-17
    • /
    • 2011
  • The seawater lift pump system is responsible for maintaining the open canal level to provide the suction flow of circulating water pump at the set point. The objective of this paper is to design a 2-stage mixed flow pump (for seawater lifting) by inverse design method and to evaluate the overall performance and the local flow fields of the pump by using a commercial CFD code. Rotating speed of the impeller is 1,750 rpm with the flow rate of 2,700 $m^3$/h. Finite volume method with structured mesh and realized k-${\varepsilon}$ turbulent model is used to guaranty more accurate prediction of turbulent flow in the pump impeller. The numerical results such as static head, brake horse power and efficiency of the mixed flow pump are compared with the design data. The simulated results are good agreement with the design data less 3% error.

Flow 3D를 이용한 다목적 수로 터널의 마찰 손실 산정 (Friction loss of multi-purpose stormwater tunnel simulated by Flow 3D)

  • 이두한;김정환;정건희
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.14-21
    • /
    • 2017
  • 본 최근 지구의 온난화로 인하여 극한 홍수가 자주 발생하고 있으며, 기존 도시 유역의 우수배제시설 용량부족 등으로 도시홍수가 빈번하게 발생하고 있으므로, 주요 범람지역의 홍수량을 우회하거나 저류하여 홍수를 방지하기 위한 수로터널의 개발이 요구된다. 본 연구에서는 교통기능과 수로기능을 동시에 갖춘 다기능 수로 터널의 설계 기준을 개발하기 위한 수리 실험 및 Flow3D를 이용한 수치모의을 수행하였다. 수치모의결과 동일한 수로 터널 구간 내 발생하는 마찰손실의 크기는 수치모의로 도출된 마찰손실이 이론적으로 계산한 마찰손실보다 더 크게 발생함을 관측하였으며, 이는 수로의 형상이 비원형인 경우에는 관의 기하학적 형상에 의한 흐름구조의 변화로 추가적인 마찰손실이 발생하는 것이 원인으로 판단된다. 마찰손실의 증가는 난류보다 층류에서 두드러졌다. 따라서 터널의 홍수량 흐름 시 마찰손실계수가 터널의 형상에 좌우되며, 실무에서 정확한 설계를 위해 방수로 터널의 형상을 주의 깊게 고려해야 한다는 결론을 내렸다. 이는 실제 방수로 터널 설계에 활용될 수 있는 기본 정보를 제공할 수 있을 것으로 보인다.

순환수취수펌프장 내의 흐름에 대한 수리 및 수치모형실험 (Hydraulic and Numerical Model Experiments of Flows in Circulation-Water-Pump Chambers)

  • 이용곤;정상화;김창완
    • 한국수자원학회논문집
    • /
    • 제38권8호
    • /
    • pp.631-643
    • /
    • 2005
  • 신설될 복합화력발전소 취수펌프장 계획안에 대하여 수치 및 수리모형실험을 수행하고 순환수취수펌프운영에 문제를 발생시킬 가능성이 발견되면 개선안을 도출하는 것이 본 연구의 목적이다. 수리모형은 1:20의 크기로 아크릴을 이용하여 제작되었고 2차원 수치모형실험은 RMA2모형을 이용하였다. 수리 및 수치모형실험의 결과를 평가하기 위하여 취수로 및 취수펌프장내 흐름에 대한 평가기준을 설정하였다. 복합화력발전소 취수펌프장의 계획안에 대한 2차원 수치모형실험을 통하여 얻어진 연직방향 와도를 수리모형실험결과와 비교하여 흐름평가기준의 하나인 와류발생 가능성을 평가하였다. 계획안은 취수펌프장내에서 큰 규모의 와류가 발생하여 순환수취수펌프운영에 문제를 발생시킬 수 있을 것으로 판단되었다. 이에 따라서 9개 개선안이 고안되어 수치모의되었다. 9개중 4개의 개선안에 대하여 수리모형실험이 수행되었다. 수리모형실험에 근거하여 4개의 개선안의 하나가 최종개선안으로 제시되었다. 공간적인 제약조건이 있는 순환수취수펌프장 및 취수로 설계의 경우 격벽과 도류벽을 이용하면 순환수취수펌프장의 흐름상황을 개선할 수 있는 것으로 나타났다.

Cyclic fatigue resistance of M-Pro and RaCe Ni-Ti rotary endodontic instruments in artificial curved canals: a comparative in vitro study

  • Feky, Hadeer Mostafa El;Ezzat, Khalid Mohammed;Bedier, Marwa Mahmoud Ali
    • Restorative Dentistry and Endodontics
    • /
    • 제44권4호
    • /
    • pp.44.1-44.11
    • /
    • 2019
  • Objectives: To compare the flexural cyclic fatigue resistance and the length of the fractured segments (FLs) of recently introduced M-Pro rotary files with that of RaCe rotary files in curved canals and to evaluate the fracture surface by scanning electron microscopy (SEM). Materials and Methods: Thirty-six endodontic files with the same tip size and taper (size 25, 0.06 taper) were used. The samples were classified into 2 groups (n = 18): the M-Pro group (M-Pro IMD) and the RaCe group (FKG). A custom-made simulated canal model was fabricated to evaluate the total number of cycles to failure and the FL. SEM was used to examine the fracture surfaces of the fragmented segments. The data were statistically analyzed and comparisons between the 2 groups for normally distributed numerical variables were carried out using the independent Student's t-test. A p value less than 0.05 was considered to indicate statistical significance. Results: The M-Pro group showed significantly higher resistance to flexural cyclic fatigue than the RaCe group (p < 0.05), but there was no significant difference in the FLs between the 2 groups (p ≥ 0.05). Conclusions: Thermal treatment of nickel-titanium instruments can improve the flexural cyclic fatigue resistance of rotary endodontic files, and the M-Pro rotary system seems to be a promising rotary endodontic file.

The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments

  • Ozyurek, Taha;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • 제42권4호
    • /
    • pp.301-308
    • /
    • 2017
  • Objectives: It was aimed to compare the cyclic fatigue resistances of ProTaper Universal (PTU), ProTaper Next (PTN), and ProTaper Gold (PTG) and the effects of sterilization by autoclave on the cyclic fatigue life of nickel-titanium (NiTi) instruments. Materials and Methods: Eighty PTU, 80 PTN, and 80 PTG were included to the present study. Files were tested in a simulated canal. Each brand of the NiTi files were divided into 4 subgroups: group 1, as received condition; group 2, pre-sterilized instruments exposed to 10 times sterilization by autoclave; group 3, instruments tested were sterilized after being exposed to 25%, 50%, and 75% of the mean cycles to failure, then cycled fatigue test was performed; group 4, instruments exposed to the same experiment with group 3 without sterilization. The number of cycles to failure (NCF) was calculated. The data was statistically analyzed by using one-way analysis of variance and post hoc Tukey tests. Results: PTG showed significantly higher NCF than PTU and PTN in group 1 (p < 0.05). Sterilization significantly increased the NCF of PTN and PTG (p < 0.05) in group 2. PTN in group 3 had significantly higher cyclic fatigue resistance than PTN group 4 (p < 0.05). Also, significantly higher NCF was observed for PTG in group 2 than in groups 3 and 4 (p < 0.05). Conclusions: PTG instrument made of new gold alloy was more resistant to fatigue failure than PTN and PTU. Autoclaving increased the cyclic fatigue resistances of PTN and PTG.

보청기용 범용 이어쉘을 위한 설계 파라미터에 관한 연구 (A Study on Design Parameters for Ready-made Ear Shell of Hearing Aids)

  • 에르덴바야르;전유용;박규석;송영록;이상민
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.1055-1061
    • /
    • 2011
  • In this study, main parameters: aperture, first bend and second bend which express a structure of ear canal are extracted in order to modeling and manufacture the ready-made ear shells of hearing aids. The proposed parameter extraction method consists of 2 important algorithms, aperture detection and feature detection. In the aperture detection algorithm, aperture of 3-D scanned virtual ear impression and parameters relating to ear shell of hearing aid are determined. The feature detection algorithm detects first bend, second bend, and related parameters. Through these two algorithms, parameters for aperture, first bend, and second bend are extracted to model the ready-made ear shell of hearing aid. The values of these extracted parameters from 36 people's right ear impression are analyzed and measured statistically. As a result of the analysis, it has been found that it is possible to classify ready-made ear shell parameters by age and size. The ready-made ear shell parameters are classified 3-size for 20 years old and 2-size for 60 years olde. Using 3D rhino program, virtual ready-made ear shell is reconstructed by parameters of every type, and simulated to model it. A final product was produced by transferring simulation result with rapid prototyping system. The modeled ready-made ear shell is evaluated with the objective and subjective method. Objective method is the comparison volume ratio and overlapped volume ratio of ear impression from randomly chosen 18 people and ready-made ear shell. And subjective method is that the final product of ready-made ear shell is used by users and the satisfaction number drawn from well fitting and comfortable testing was evaluated. In the result of the evaluation, it has been found that volume ration is 70%, big and middle size ready-made ear shell products are possible, and the satisfaction number is high.

Screw-in forces during instrumentation by various file systems

  • Ha, Jung-Hong;Kwak, Sang Won;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제41권4호
    • /
    • pp.304-309
    • /
    • 2016
  • Objectives: The purpose of this study was to compare the maximum screw-in forces generated during the movement of various Nickel-Titanium (NiTi) file systems. Materials and Methods: Forty simulated canals in resin blocks were randomly divided into 4 groups for the following instruments: Mtwo size 25/0.07 (MTW, VDW GmbH), Reciproc R25 (RPR, VDW GmbH), ProTaper Universal F2 (PTU, Dentsply Maillefer), and ProTaper Next X2 (PTN, Dentsply Maillefer, n = 10). All the artificial canals were prepared to obtain a standardized lumen by using ProTaper Universal F1. Screw-in forces were measured using a custom-made experimental device (AEndoS-k, DMJ system) during instrumentation with each NiTi file system using the designated movement. The rotation speed was set at 350 rpm with an automatic 4 mm pecking motion at a speed of 1 mm/sec. The pecking depth was increased by 1 mm for each pecking motion until the file reach the working length. Forces were recorded during file movement, and the maximum force was extracted from the data. Maximum screw-in forces were analyzed by one-way ANOVA and Tukey's post hoc comparison at a significance level of 95%. Results: Reciproc and ProTaper Universal files generated the highest maximum screw-in forces among all the instruments while M-two and ProTaper Next showed the lowest (p < 0.05). Conclusions: Geometrical differences rather than shaping motion and alloys may affect the screw-in force during canal instrumentation. To reduce screw-in forces, the use of NiTi files with smaller cross-sectional area for higher flexibility is recommended.