• Title/Summary/Keyword: simple tests

Search Result 1,236, Processing Time 0.025 seconds

폐기물 매립지 침출수와 침출수 내의 휴믹물질이 GCL의 투수계수에 미치는 영향

  • 한영수;이재영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.208-211
    • /
    • 2001
  • Geosynthetic Clay Liners (GCLs) have been used for the applications of the hydraulic containment system in landfill due to inexpensive costs, simple workability and distinguished ability as a barrier material. However, bentonite of GCLs is easy to be damaged by the chemical solutions. Thus, there is a need to evaluate the potential susceptibility of GCLs causing Increase the hydraulic conductivity when GCLs are exposed to raw leachate and dissolved humic substances from landfill leachate. The hydraulic conductivity tests were performed with flexible-wall permeameter (the falling -headwater/rising -tailwater procedure) in order to verify the potential susceptibility of GCLs. The values of the hydraulic conductivity conducted with raw leachate as a permeant liquid increased considerably; however, The change of the hydraulic conductivity in the case of humic and fulvic acid were not worthy of notice. As the results of swelling tests of bentonite, however, humic substances can affect badly on the dispersion behavior of bentonite. These results indicate that humic substances dissolved in leachate could reduce the hydraulic conductivity of GCLs in landfill.

  • PDF

Member capacity of columns with semi-rigid end conditions in Oktalok space frames

  • Zhao, Xiao-Ling;Lim, Peter;Joseph, Paul;Pi, Yong-Lin
    • Structural Engineering and Mechanics
    • /
    • v.10 no.1
    • /
    • pp.27-36
    • /
    • 2000
  • The Oktalok nodal connection system is an aesthetic and efficient system. It has been widely used throughout Australia. The paper will briefly introduce the concept and application of the Oktalok nodal system. The existing design method is based on the assumption that the joints are pin-ended, i.e., the rotational stiffness of the joints is zero. However the ultimate capacity of the frame may increase significantly depending on the rotational stiffness of the joints. Stiffness tests and finite element simulations were carried out to determine the rotational stiffness of the Oktalok joints. Column buckling tests and non-linear finite element analyses were performed to determine the member capacity of columns with semi-rigid end conditions. A simple formulae for the effective length factor of column buckling is derived based on the above experimental and theoretical investigations.

Analysis and tests of flexibly connected thin-walled channel frames

  • Tan, S.H.;Seah, L.K.
    • Structural Engineering and Mechanics
    • /
    • v.2 no.3
    • /
    • pp.269-284
    • /
    • 1994
  • The analysis and tests of thin-walled channel frames including nonlinear flexible or semi-rigid connection behaviour is presented. The semi-rigid connection behaviour is modelled using a mathematical approximation of the connection flexibility-moment relationship. Local instability such as local buckling and torsional flexural buckling of the member are included in the analysis. The full response of the frame, up to the collapse load, can be predicted. Experimental investigation was carried out on a series of simple double storey symmetrical frames with the purpose of verifying the accuracy and validity of the analysis. Agreement between the theoretical and experimental results is acceptable. The investigation also shows that connection flexibility and local instability such as local buckling and torsional flexural buckling can affect the behaviour and strength of thin-walled frames significantly. The results can also provide further insight into the advanced study of practical structures where interaction between flexible connections and phenomenon associated with thin-walled members are present.

Application of a wireless pressure sensing system to coastal wind monitoring

  • Pinelli, J.P.;Subramanian, C.S.;Lapilli, C.;Buist, L.
    • Wind and Structures
    • /
    • v.8 no.3
    • /
    • pp.179-196
    • /
    • 2005
  • This paper describes the application of a wireless data acquisition system to monitor wind pressures and velocities with absolute pressure sensors and an anemometer. The system was developed for future deployment, as part of a research effort currently underway to instrument coastal homes in Florida to monitor roof wind pressures during hurricanes. The proposed wireless system will replace the current system that involves a large amount of hardwired connections from the sensors to the data processing unit that requires labor intensive wiring and preparation of the home. The paper describes comparison studies and field tests to assess the performance of the system. The new system offers the advantages of light hardware, ease of installation, capacity for 48 hours of continuous data acquisition, good frequency and amplitude responses, and a relatively simple maintenance. However, the tests also show that the shape of the shell that has been previously used to protect the sensors might interfere with the proper measurement of the pressures.

A Study on the Prediction of the Remaining Life of the Barrel in Small Arms using Analyzing Dispersion (분산도 분석에 의한 총열 잔여수명 예측에 관한 연구)

  • Kim, Hyun-Jun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.139-145
    • /
    • 2009
  • This paper includes that there is the way to make the prediction of the remaining life of the barrel in small arms using analyzing dispersion. There are some ways to know the period to change the barrel such as the method of detecting the inner surface directly or inspecting the scratch using the optical sensor. However, it is a more easy way to check the dispersion for soldiers and the directors in a logistics command. Therefore, this study is conducted to focusing on the relation between firing round and dispersion. And the simple equation experimentally derives from pre-tests and analyses. Also, this equation is confirmed through the firing tests during the period of developing K11. In that sense, it can be easily applied to know the period of changing the barrel of small arms in the field army.

축변환 구성방정식을 이용한 암석 이방성 탄성계수 산정

  • 김영수;이재호;허노영;박영화;최정호
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.729-736
    • /
    • 2000
  • For nonhomogeneous and anisotropic rocks such as schist, shale, etc, a method to determine the anisotropic elastic constants was proposed. Many authors have investigated in detail the behavior elastic constants of anisotropy rocks(Pinto 1970, Amadei 1983, 1992, Amadei & Savage 1989). They concluded that equations of elastic constants E$_1$, E$_2$ and G$_2$ can be derived from the measured strains in arbitrary three directions. And, modulus of elasticity varies according to the inclination of discontinuity in specimens. If we attach three strain gages in accordance with the directions of anisotropy on the rock specimen under uni-axial compression and diametral compression tests, anisotropy elastic constants can be determined by these equations. With this method, the degree of anisotropy will be easily evaluated by simple laboratory test. This paper presents the results of elastic constants due to the angle of bedding planes of anisotropic rock, such as shale, in uni-axial compression and diametral compression tests

  • PDF

A report on the problems associated with PDA testing in Korea (국내 동재하시험의 문제점에 대한 보고)

  • Lee, Myung-Whan;Hong, Hun-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1259-1268
    • /
    • 2006
  • Dynamic pile loading test using PDA was introduced in 1994. Because of its economy and relatively easy and simple procedure, the number of PDA application increased quite rapidly. It is assumed that more than 10,000 dynamic pile loading tests are done annually. While the number of testing increases sharply, the quality of the tests does not really improve but the number of serious problems due to improper testing increases. According to the limited experiences of the authors, the common problems found in most of the cases are caused by ignorance of the most basic and fundamental requirements. In this paper some case histories are explained and the proposed solution is introduced.

  • PDF

Axial crush and energy absorption characteristics of Aluminum/GERP hybrid square tube (알루미늄/GFRP 혼성 사각튜브의 정적 압축 붕괴 및 에너지 흡수 특성)

  • 김구현;이정주
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.11a
    • /
    • pp.168-171
    • /
    • 1999
  • For the axial crushing tests of various shape of tubes, it was reported that composite tubes need trigger mechanism to avoid brittle failure. In this study, static axial crush tests were performed with the new aluminum/GFRP hybrid tubes. Glass/Epoxy prepregs were wrapped around aluminum tube and co-cured. The failure of hybrid tube was stable and progressive without trigger mechanism, and specific energy absorption was increased to maximum 34% in comparison with aluminum tube. Effective energy absorption is possible for inner aluminum tube because wrapped composite tube constrain the deflection of aluminum tube and reduce the folding length. The failure of hybrid composite tube was stable without trigger mechanism because inner aluminum tube could play the role of crack initiator and controller. Aluminum/Glass-Epoxy hybrid tube is suitable for the vehicle front structure due to effective energy absorption capability, easy production, and simple application for RTM process.

  • PDF

Theory and Experiment for Electromagnetic Shaft Current in Rotating Machinery

  • Kim, Chaesil;Park, Jong-Kweon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.3 no.1
    • /
    • pp.20-25
    • /
    • 2002
  • Electrical damages to critical parts in rotating machinery have caused many machinery failures and hours of costly downtime. The problem of shaft currents generated in non-electrical machines has puzzled both users and manufacturers of these machines. The main solution for preventing electromagnetic type damage is to demagnetize all of the machinery parts, however this is costly and time consuming. Therefore a thorough investigation into the causes and physical characteristics of electromagnetic shaft currents is needed. In this paper, the self excitation theory was developed far a simple model, an axial flux Faraday disk machine surrounded by a long solenoid. Experimental tests were conducted to investigate the physical characteristics on an electromagnetic self excitation rig. The theory showed that the directions of both the shaft rotation and the coil turns should be identical if self excitation is to occur. From the tests, the electromagnetic type shaft current had both AC and DC components occurred at all vibration frequencies. This could point to a way to detect small instabilities or natural frequency locations by monitoring shaft currents.

Ultimate Strength of Composite Beams with Unreinforced Web Opening (유공 합성보의 강도식에 관한 연구)

  • 김창호;박종원;김희구
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.5
    • /
    • pp.101-110
    • /
    • 2000
  • A practical approach of calculating the ultimate strength of composite beams with unreinforced web opning is proposed through shear behavioral tests. In this method, the slab shear contribution at the opening is calculated as the smaller value of the pullout capacity of shear connector at the high moment end and the one way shear capacity of slab. A simple interaction equation is used to predict the ultimate strength under simultaneous bending moment and shear force. Strength prediction by the proposed method is compared with previous test results and the predictions by other analytical methods. The comparison shows that the proposed method predicts the ultimate capacity with resonable accuracy.