• Title/Summary/Keyword: similar materials

Search Result 4,776, Processing Time 0.036 seconds

Antioxidant activity and quality characteristics on the maturation period of the soy sauce with Gastrodia elata and oak mushroom (Lentinus edodes) (천마 및 표고버섯 첨가 전통간장의 숙성기간별 품질특성 및 항산화 활성)

  • Kwon, Hyuk-Jin;Kim, Hwa-Sun;Choi, Yoon-Hee;Choi, Ji-Ho;Choi, Hae-Sun;Song, Jin;Park, Shin-Young
    • Food Science and Preservation
    • /
    • v.21 no.2
    • /
    • pp.231-238
    • /
    • 2014
  • This study was performed to investigate the changes in antioxidant activity and quality characteristics of soy sauce with Gastrodia elata (GK) and oak mushroom (MK) in maturation period to develop a new Kanjang product with improved functional and sensory characteristics. The pH was decreased, and the total acidity was higher in GK at 25-day maturation period. Although the total sugar content increased at 15 days with GK, it was reduced after 20 days. The reducing sugar, however, showed no notable differences after 20 days. The protease activities of GK was rapidly increased after 20 days. The total polyphenol and flavonoid contents tended to be similar and dramatically increased after 15 days. On the other hand, the DPPH radical scavenging activity of MK was higher than that of GK. These results showed that the 20-day maturation period of GK greatly enhanced its antioxidant activity and quality characteristics. It is thus expected to be used as functional materials.

Distal Radius Osteosarcoma (원위 요골 골육종)

  • Song, Won-Seok;Won, Ho-Hyun;Lee, Jeong-Dong;Jeon, Dae-Geun
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.2
    • /
    • pp.55-61
    • /
    • 2010
  • Purpose: We analyzed the clinical outcome of osteosarcoma developed in distal radius and the effect of delayed treatment on prognosis. Materials and Methods: Twelve patients with distal radius osteosarcoma were analysed. We categorized patients into two groups of standard treatment or non-standard treatment. The patients of standard treatment group are all stage IIB and non-standard treatment group includes five stage IIB and one stage III. Results: Five-year overall survival and disease-free survival rates of standard treatment group were 100% and 83%. Five-year overall survival rate of non-standard treatment group was 44%. Between two group, there are differences in age, tumor size, surgery type, symptom duration. Conclusion: Distal radius osteosarcoma have good prognosis than other extremity osteosarcoma. Survival rate of non-standard treatment group were lower than standard treatment group. Although the prognosis of non standard treatment group is poorer, the duration till death was longer than that of other sites with similar condition. Further multi-institutional study should be needed.

Bond Strength Evaluation of RC Beams on the Rib Shape of Reinforcing Bars (철근 마디 형상에 따른 RC 휨부재의 부착강도 평가)

  • Hong, Geon-Ho;Kim, Jin-Ah;Choi, Oan-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.393-400
    • /
    • 2011
  • The needs for high strength structural materials have recently increased, because construction and cost efficiencies are demanded by the costumers. But, the use of high strength reinforcing bars requires longer development and splice lengths compared to normal strength bars. This restriction may cause reduction in construction efficiency and require more complicated details. The purpose of this paper is to evaluate the bond strength on the rib shape of reinforcing bars to decrease development and splice lengths of high strength reinforcements. Total of 5 simple beam specimens were tested, and the main test variable was a rib shape of reinforcing bars. Test data was analyzed in the viewpoint of bond strength, load-deflection relationship, and crack pattern. Test results indicated that the bond strength of high relative rib area reinforcing bars increased up to 11% compared to normal strength reinforcements. And the improved rib shape reinforcements, which were formed with high and low height rib, increased the bond strength up to 23% even though the relative rib area was same as the high relative rib area reinforcements. Serviceability performances such as deflection number of cracking, and maximum crack width were similar in all specimens, so it is safe to conclude that the improved rib shape reinforcements can be applied to the structural members.

Water Permeability Performance Evaluation of Mortar Containing Crack Self-healing Mineral Admixtures (균열 자기치유 재료 혼입 모르타르의 투수성능 평가)

  • Lee, Woong-Jong;Hwang, Ji-Soon;Ahn, Sang-Wook;Lee, Kwang-Myong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.463-469
    • /
    • 2016
  • In this paper, compressive strength and water permeability performance for two types of crack self-healing materials such as SH-PO-0 composed of mineral admixtures(expansive agent, swelling material and crystal growth agent) and SH-PO-(5, 15, 30) blended with SH-PO-0 and phosphate additive(PO) dissolving easily calcium ion, were evaluated. The test results show that the water flow of SH-PO-0 decreased steeply at the early age although compressive strength decreased about 9% at 28 days compared with OPC. The higher PO replacement ratio is, the lower compressive strength and more improved water permeability performance is, and thus, based on such results, adequate PO replacement ratio is 15%. It is also found that the self-healing performance of SH-PO-15 was quite improved at the early ages and however, the performance of SH-PO-15 is similar to one of SH-PO-0 at long-term ages, and 28 days compressive strength of SH-PO-15 decreased about 8% compared with SH-PO-0. In addition, it is confirmed from the analysis of SEM-EDS that calcium ions of SH-PO-15 were crystallized more than those of SH-PO-0.

INFLUENCE OF CIGARETTE SMOKE INHALATION ON DENTAL IMPLANT OSSEOINTEGRATION IN THE RAT (백서에 식립한 치과용 임플란트의 골유착에 흡연이 미치는 영향)

  • Kim, Se-Ho;Kim, Soung-Min;Kim, Ji-Hyuck;Park, Young-Wook;Park, Chan-Jin;Jung, Ki-Myoung;Lee, Suk-Keun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.4
    • /
    • pp.291-299
    • /
    • 2005
  • Objectives : It is well known that cigarette smoking is harzardous to the osseointegration of dental implant, due to the impaired wound healing accompanied by reduced alveolar bone density. The aim of this study is to evaluate the influence of cigarette smoke on the implant osseointegration by the time factor consideration. Materials and methods : Twenty-four male Spraque-Dawley rats (8 weeks, weighting 200 to 250g) were used in this study. In the experimental group, 13 rats were exposed to cigarette smoke, 8 minutes per day during 6 weeks, and 12 rats in the control group were not exposed at any time. RBM (Resorbed blasting media) surfaced implant (diameter 3.3mm, length 5.0mm, AVANA Co., Korea) was placed in the right femur of each rat. Each implant with surrounding bone was prepared with microtome (cutting band 0.2mm$^{(R)}$, EXAKT Co., Germany) after 1 day, 2, 4, 8 and 12 weeks and stained with toluidine blue (1%). Another clinical investigation of each implant was also done at each evaluation time. Results : Clinical investigation around implant fixture showed that there were no significant differences between the control and experimental group. Microscopic observation around implant fixture showed that there were significant differences between the control and experimental group at the initial stage after implant fixture installation. Experimental group showed a decreased bone to implant contact within 4 weeks compared to control group, but showed similar characteristics after 4 weeks. Conclusion : Smoking inhalation effect on the dental implant showed the impaired wound healing by vasoconstriction and decreased intramedullary blood flow at initial stage of osseointegration. This experimental results can be clinically useful to the implant surgery of smoking patients.

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF $BR{\AA}NEMARK\;NOVUM^{(R)}$ IMMEDIATE IMPLANT PROSTHODONTIC PROTOCOL ($Br{\aa}nemark\;Novum^{(R)}$ 즉시 임플랜트 보철 수복 방법에 관한 삼차원 유한요소 분석적 연구)

  • Kim Woo-Young;Kim Yung-Soo;Jang Kyung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.5
    • /
    • pp.463-476
    • /
    • 2001
  • Since the treatment of edentulous patients with osseointegrated implant was first introduced more than 30 years ago, implant therapy has become one of the most important dental treatment modalities today. Based on the previous experience and knowledge, $Br{\aa}nemark\;Novum^{(R)}$ protocol was introduced with the concept of simplifying surgical and prosthetic technique and reducing healing time recently. This protocol recommends the installation of three 5mm wide diameter futures in anterior mandible and the prefabricated titanium bars for superstructure fabrication. This study was designed to analyze the stress distribution at fixture and superstructure area according to changes of fixture number, diameter and superstructure materials. Four 3-dimensional finite element models were fabricated. Model 1 - 5 standard fixtures (13mm long and 3.75mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 2- 3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 3-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and resin Model 4-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and porcelain A 150N occlusal force was applied on the 1st molar of each model in 3 directions - vertical($90^{\circ}$), horizontal($0^{\circ}$) and oblique($120^{\circ}$). After analyzing the stresses and displacements, following results were obtained. 1. There were no significant difference in stress distribution among experimental models. 2. Model 2, 3, 4 showed less amount of compressive stress than that of model 1. However, tensile stress was similar. 3. Veneer material with a high modulus of elasticity demonstrated less stress accumulation in the superstructure. Within the limites of this study, $Br{\aa}nemark\;Novum^{(R)}$ protocol demonstrated comparable biomechanical properties to conventional protocol.

  • PDF

Study of the Expression of FasL and of Apoptosis in Gastric Epithelial Dysplasia and Gastric Adenocarcinomas (위상피이형성과 위암종에서 FasL의 발현 및 Apoptosis에 관한 연구)

  • Park Gun Uk;Han Sang Young;Lee Jong Hun;Keum Dong Joo;Roh Myung Hwan;Choi Seok Ryeol;Kim Jong Seong;Roh Mee Sook
    • Journal of Gastric Cancer
    • /
    • v.1 no.2
    • /
    • pp.83-91
    • /
    • 2001
  • Purpose: This study was to observe whether the apoptotic function of tumor-infiltrating lymphocytes (TIL) is induced in human gastric epithelial dysplasia and gastric adenocarcinoma according to the role of FasL expression. Materials and Methods: A total of 56 gastric epithelial dysplasia and gastric adenocarcinoma patients were enrolled in this study: 9 cases of gastric epithelial dysplasia, 18 cases of early gastric carcinomas (EGC) and 29 cases of advanced gastric carcinomas (AGC). Immunohistochemical staining was performed for FasL and CD45, and the terminal deoxynucleotidyl transferase mediated dUTP nick end labelling (TUNEL) method was used to detect cell death in tumor-infiltrating lymphocytes. Results: 1) Positive reactions of FasL to neoplastic cells were $88.9\%$ (8/9) in gastric epithelial dysplasia, $83.3\%$ (15/18) in EGC, and $75.9\%$ (22/29) in AGC. 2) Expression of TIL was decreased in the FasL positive region and was increased in the FasL negative region, and significant expression of TIL was observed in the AGC group (P=0.001). 3) Expression of apoptotic TIL was very similar to the FasL expression, and $100\%$ expression was observed in gastric epithelial dysplasia group. 4) Expression of apoptotic TIL was increased in the FasL positive region and decreased in the FasL negative region, and significant apoptotic expression was observed in the gastric epithelial dysplasia and EGC groups (P=0.0420, P=0.0263, respectively). Conclusion: These results suggest that FasL is a prevalent mediator of immune privilege in epithelial dysplasia and cancer of the stomach.

  • PDF

Classification of Microsatellite Alterations Detected in Endoscopic Biopsy Specimens of Gastric Cancers (단순반복염기서열의 변이 형태에 따른 위암 내시경 조직의 유전자형 분류)

  • Choi Young Deok;Choi Sang Wook;Jeon Eun Jeong;Jeong Jeong Jo;Min Ki Ouk;Lee Kang Hoon;Lee Sung;Rhyu Mun Gan
    • Journal of Gastric Cancer
    • /
    • v.4 no.2
    • /
    • pp.109-120
    • /
    • 2004
  • Purpose: Individual gastric cancers demonstrate complicated genetic alterations. The PCR-based analysis of polymorphic microsatellite sequences on cancer-related chromosomes has been used to detect chromosomal loss and microsatellite instability. For the purpose of preoperative usage, we analyzed the correspondance rate of the microsatellite genotype between endoscopic biopsy and surgical specimens. Materials and Methods: Seventy-three pairs of biopsy and surgical specimens were examined for loss of heterozygosity and microsatellite instability by using 40 microsatellite markers on eight chromosomes. Microsatellite alterations in tumor DNAs were classified into a high-risk group (baselinelevel loss of heterozygosity: 1 chromosomal loss in diffuse type and high-level loss of heterozygosity: 4 or more chromosomal losses) and a low-risk group (microsatellite instability and low-level loss of heterozygosity: 2 or 3 chromosomal losses in diffuse type or $1\∼3$ chromosomal losses in intestinal type) based on the extent of chromosomal loss and microsatellite instability. Results: The chromosomal losses of the biopsy and the surgical specimens were found to be different in 21 of the 73 cases, 19 cases of which were categorized into a genotype group of similar extent. In 100 surgical specimens, the high-risk genotype group showed a high incidence of nodal involvement (19 of 23 cases: $\leq$5 cm; 23 of 24 cases: >5 cm) irrespective of tumor size while the incidence of nodal involvement for the low-risk genotype group depended on tumor size (5 of 26 cases: $\leq$5 cm; 18 of 27 cases: >5 cm). Extraserosal invasion was more frequent in large-sized tumor in both the high-risk genotype group ($\leq$5 cm: 12 of 23 cases; >5 cm: 23 of 24 cases) and the low-risk genotype group ($\leq$5 cm: 7 of 26 cases; >5 cm: 16 of 27 cases). The preoperative prediction of tumor invasion and nodal involvement based on tumor size and genotype corresponded closely to the pathologic tumor stage (ROC area >0.7). Conclusion: An endoscopic biopsy specimen of gastric cancer can be used to make a preoperative genetic diagnosis that accurately reflect the genotype of the corresponding surgical specimen.

  • PDF

INFLUENCE OF LIGHT SOURCE AND CURING TIME ON SURFACE HARDNESS OF RESIN COMPOSITES (중합 광원과 중합 시간이 복합레진의 표면 경도에 미치는 영향)

  • Bae, Sang-Man;Lee, Kwang-Hee;Kim, Dae-Eup;Ahn, Ho-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.2
    • /
    • pp.199-206
    • /
    • 2001
  • The purpose of study was to compare the plasma arc light with the halogen light in compostie resin curing. Three composite resin materials(Z-100, 3M, USA; Tetric Ceram, Vivadent, Liechtenstein; SureFil, Dentsply, USA) were filled in the teflon molds (4mm in diameter and 2, 3, 4, 5mm in thickness) and cured with either the conventional low-intensity light curing unit with a halogen lamp (Optilux 360, Demetron, U.S.A.) for duration of 40 seconds or with the high-intensity light curing unit with a plasma arc lamp (Flipo, Lokki, France) for duration of 3, 6, and 9 seconds. The intensity of halogen light was about $370mW/cm^2$ and that of plasma light was about $1,900mW/cm^2$. After one week, the surface hardnesses of both the top and the bottom of the resin samples were measured with a microhardness tester(MXT70, Matsuzawa, Japan). There were significant differences in the hardness between the top and the bottom of the resin samples except the 2mm thickness samples cured by halogen light for 40s or by plasma light for 9s. There was no significant difference between the hardness values of the top surfaces of the thickness groups. The hardness values of the bottom surfaces decreased as the curing time decreased and as the thickness of resin samples increased, and the three kinds of resin composites showed similar patterns. The results suggest that the halogen light for 40 seconds might be able to cure greater depth of resin composites than the plasma light for 3, 6, or 9 seconds.

  • PDF

Comparison of the Quantulus 1220 and 300SL Liquid Scintillation Counters for the Analysis of 222Rn in Groundwater

  • Kim, Hyuncheol;Jung, Yoonhee;Lee, Wanno;Choi, Guen-Sik;Chung, Kun Ho;Kang, Mun Ja
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.395-401
    • /
    • 2016
  • Background: Liquid scintillation counters (LSCs) are commonly used as an analytical method for detecting $^{222}Rn$ in groundwater because they involve a simple sample pretreatment and allow high throughout with an autosampler. The Quantulus 1220 is the best-selling LSC in Korea, but its production was stopped. Recently, a new type of LSC, the 300SL, was introduced. In this study, the 300SL was compared with the Quantulus 1220 in order to evaluate the ability of each apparatus to detect $^{222}Rn$ in groundwater. Materials and Methods: The Quantulus 1220 and 300SL were used to detect the presence of $^{222}Rn$. Radon gas was extracted from a groundwater sample using a water-immiscible cocktail in a LSC vial. The optimal analytical conditions for each LSC were determined using a $^{222}Rn$ calibration source prepared with a $^{226}Ra$ source. Results and Discussion: The optimal pulse shape analysis level for alpha and beta separation was 80 for the Quantulus 1220, and the corresponding pulse length index was 12 in the 300SL. The counting efficiency of the Quantulus 1220 for alpha emissions was similar to that of the 300SL, but the background count rate of the Quantulus 1220 was 10 times lower than that of the 300SL. The minimum detectable activity of the Quantulus 1220 was $0.08Bq{\cdot}L^{-1}$, while that of the 300SL was $0.20Bq{\cdot}L^{-1}$. The analytical results regarding $^{222}Rn$ in groundwater were less than 10% different between these LSCs. Conclusion: The 300SL is an LSC that is comparable to the Quantulus 1220 for detecting $^{222}Rn$ in groundwater. Both LSCs can be applied to determine the levels of $^{222}Rn$ in groundwater under the management of the Ministry of Environment.