• Title/Summary/Keyword: similar materials

Search Result 4,776, Processing Time 0.03 seconds

Comparison of brassiere sales patterns in Korea and China

  • Cha, Su-Joung;Sohn, Hee-Soon
    • Journal of Fashion Business
    • /
    • v.12 no.6
    • /
    • pp.107-123
    • /
    • 2008
  • The purpose of this research is to compare and analyze the brassiere patterns sold in Shanghai and Korea and to present basic materials needed in developing the brassiere patterns in Chinese adult women market. The study subject which is to find the difference in brassiere patterns of Korea and China has been selected of 3 Korean brands and 4 Chinese brands. 1. For the brassiere patterns sold in Korea, it were using the same size for the width of Hook&Eye, space between the shoulder lace on the back, slope of wing and the location of the Keeper was similar. 2. For the cup supporting base, Chinese brassiere covers the lower part of the breast and as it is not comfortable and has a phenomenon of loosening up, there were severe puckering. For issues in the wearing experiment, amendments in patterns with the cup part was required. 3. Chinese brassieres were big differences in wing angles and for Aimer, it had the steepest trend in wings and thus the wings headed down and for Gujin, as the angle of the wing was smaller than $90^{\circ}$, it was heading upward. 4. Upon comparing the patterns of the Korean and Chinese brassiere, although most of the sizes excluding the wing angle had similar sizes, there was big differences in the wing angle. The reason why the brassiere patterns sold in China had bigger wing angle was due to the fact that more Chinese women had sway back body type than the Korean women and should reflect such difference in body size into making the brassiere patterns for each women.

Comparison of Radial Artery and Saphenous Vein Composite Y Grafts during Off-pump Coronary Artery Bypass

  • Wi, Jin-Hong;Joo, Hyun-Chel;Youn, Young-Nam;Song, Suk-Won;Kim, Tae Hoon;Yoo, Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.46 no.4
    • /
    • pp.265-273
    • /
    • 2013
  • Background: The safety and efficacy of arterial composite grafts for total arterial revascularization have been demonstrated. The saphenous vein (SV) is a widely used graft because of its accessibility, sufficient length, and ease of manipulation. Our aim was to compare mid-term outcomes of saphenous vein Y-grafts with radial artery Y-grafts joined by anastomosis to the left internal thoracic artery. Materials and Methods: Records of off-pump coronary artery bypass grafting with composite Y-grafts based on the left internal thoracic artery technique in 552 patients were analyzed retrospectively. After propensity score matching, 79 radial arterial (RA) composite grafts (RA group) and 79 saphenous vein composite grafts (SV group) were compared. The duration of mean follow-up was $24.6{\pm}14.6$ months (range, 1 to 55 months). Results: There were no differences in surgical mortality, all-cause mortality, or morbidity among the groups. Rates of 4-year survival were 91.7% and 96.3% in the RA and SV groups, respectively (p=0.519). The coronary reintervention-free survival rate and freedom from major adverse cardiovascular or cerebrovascular events were similar in the two groups (p=0.685, p=0.564). Conclusion: Construction of composite Y-grafts using the radial artery or saphenous vein showed similar mid-term results. Long-term follow-up and randomized trials will be needed to confirm our present conclusions.

Palaeomagnetism of the Taedong Supergroup in the Kimpo Area (김포(金浦))지역 대동누층군(大同累層群)에 대한 고자적(古磁的) 연구)

  • Kim, In-Soo;Min, Kyung Duck;Lee, Mi Yeong;Kang, Hee-Cheol;Chun, Hee Young
    • Economic and Environmental Geology
    • /
    • v.26 no.2
    • /
    • pp.193-206
    • /
    • 1993
  • A total of 111 independently oriented core samples were drilled at 12 sites in fue Kimpo area ($37.70^{\circ}N$, $126.55^{\circ}E$) of the Taedong Supergroup. The Taedong strata are composed of sandstone, conglomeratic sandstone, shale and thin coal seams. The age of the strata is known to be Late Triassic-Early Jurassic according to freshwater Esfuerites and plant fossil (Dictyophyllum-Clathropteris flora) contents. Through AF and thermal demagnetization, an area-mean ChRM direction of $D=48.3^{\circ}\;I=40.3^{\circ}\;{\alpha}_{95}=7.9^{\circ}\;k=59.5$, n=7 was obtained. It passed fold and reversal test in the formation-mean level. Fold test was not significant in the area-mean level. The palaeomagnetic north pole calculated from the area-mean lies at $46.3^{\circ}N$, $222.0^{\circ}E$ with dp=5.7, $dm=9.5^{\circ}$. This pole position is very similar to those of the South China Block (SCB) in Triassic times. Palaeolatitude of the Kimpo area in the Taedong times was $23.0^{\circ}N$, again very similar to the palaeolatitude of the South China Block in the Late Triassic. This low latitude of the study area at the time of deposition explains the tropical-subtropical nature of fossil contents of the Taedong Supergroup.

  • PDF

Hypertrophical Changes of the Corpus Allatum Caused by Ovariectomy in Blattella germanica (난소제거 바퀴에서 알라타체의 이상비대화에 관한 연구)

  • Han, Sung-Sik;Kim, Kil-Heung;Scha, Coby
    • Applied Microscopy
    • /
    • v.28 no.1
    • /
    • pp.91-105
    • /
    • 1998
  • The present study is undertaken to investigate the hypertrophical changes of the corpus allatum (corpora allata, CA) after the ovariectomy in Blattella germanica. In particular, the ultrastructural aspects of the normal and ovariectomized conditions, and induced factors of the hypertrophic phenomenon are focused. Ultrastructure of the CA from an immediately emergent adult is similar to that of the last larval stage that has stopped secreting juvenile hormone. The CA is composed of undifferentiated cells, exhibiting an electron-lucent matrix, a few mitochondria and less smooth endoplasmic reticulum. The karyoplasm occupy most of the cytoplasm. Electron-dense materials are filled with the intercellular spaces and gap junctions are also found. Almost no ultrastructural changes have been noticed during seven days until the oviposition. However, considerable changes in structure have been detected soon after the oviposition. Mitochondria are increased dramatically in number and cristae, and changed to the filamentous form with a high electron density. In addition, Golgi complexes, microtubules, and polysomes are also increased. After an oviposition, the total volume of the CA are decreased again. The volume of the CA are increased continuously, hypertrophy, after the ovariectomy. Morphological aspects of the CA in an early stage after the removal are similar to the structure of the secondary egg maturation. Large and electron dense globules are observed in the ovariectomized CA cytoplasms and they are present in those cells for a long period of time. Yet such a hypertrophical phenomenon occur only in the specific cells. The hypertrophy are caused by hollowing the part of the CA cells and later filling such site with polysomes. In 42 days after the ovariectomy, the nuclear membranes disappear in the CA cells, thus, exhibiting the prokaryotic-like features. Some results of the current study will contribute to the establishment of the model that explain unusual changes accompanied by certain treatment in insects and/or further in animals.

  • PDF

A HISTOMORPHOMETRIC STUDY OF TWO DIFFERENT THREADED CP TITANIUM IMPLANTS (국내 제작 Avana 임프란트와 $Br{\aa}nemark$ 임프란트 주위 골조직에 대한 광학 및 형광 현미경학적 연구)

  • Han, Dong-Hoo;Jeon, Young-Sik;Kim, Jin;Kim, Seon-Jae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.531-541
    • /
    • 1999
  • The purpose of this study was to compare surface roughness and bone formation around two types of threaded commercially pure titanium implants manufactured by two different companies. The test implants were manufactured by Sumin synthesis dental materials Co. (Avana, Busan, Korea), while the controls were manufactured by Nobel Biocare (MK II, Goteborg, Sweden). To compare bone formation adjacent to newly product implant with $Br{\aa}nemark$ MK II implant, surface roughness was measured by Accurate 1500M and histomorphometric analysis was done. The results were as follows: 1. Measurement of surface roughness showed that Avana implant had a slightly more irregular surface compared with $Br{\aa}nemark$ implant. 2. In the light microscopic studies, no infiltration of inflammatory cells nor the giant cells were observed on both groups. 3. In the light and fluorescent microscopic studies, the amount of osseointegration and the extent and the timing of bone formation were similar. 4. There were no statistically difference between two groups in the average bone to implant con-tacts. Branemark implant; 67% (SD 23%), Avana implant; 70% (SD 16%). Comparing with $Br{\aa}nemark$ implant, Avana implant made of CP grade II titanium showed similar good bone healing, formation and osseointegration.

  • PDF

Magnesium vs. machined surfaced titanium - osteoblast and osteoclast differentiation

  • Kwon, Yong-Dae;Lee, Deok-Won;Hong, Sung-Ok
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.3
    • /
    • pp.157-164
    • /
    • 2014
  • PURPOSE. This study focused on in vitro cell differentiation and surface characteristics in a magnesium coated titanium surface implanted on using a plasma ion source. MATERIALS AND METHODS. 40 commercially made pure titanium discs were prepared to produce Ti oxide machined surface (M) and Mg-incorporated Ti oxide machined surface (MM). Surface properties were analyzed using a scanning electron microscopy (SEM). On each surface, alkaline phosphatase (ALP) activity, alizarin red S staining for mineralization of MC3T3-E1 cells, and quantitative analysis of osteoblastic gene expression, were evaluated. Actin ring formation assay and gene expression analysis of TRAP and GAPDH performing RT-PCR were performed to characterize osteoclast differentiation on mouse bone marrow-derived macrophages (BMMs). RESULTS. MM showed similar surface morphology and surface roughness with M, but was slightly smoother after ion implantation at the micron scale. M was more hydrophobic than MM. No significant difference between surfaces on ALP activity at 7 and 14 days were observed. Real-time PCR analyses showed similar levels of mRNA expression of the osteoblast phenotype genes; osteopontin (OPN), osteocalcin (OCN), bone sialoprotein (BSP), and collagen 1 (Col 1) in cell grown on MM at 7, 14 and 21 days. Alizarin red S staining at 21 days showed no significant difference. BMMs differentiation increased in M and MM. Actin ring formation assay and gene expression analysis of TRAP showed osteoclast differentiation to be more active on MM. CONCLUSION. Both M and MM have a good effect on osteoblastic cell differentiation, but MM may speed the bone remodeling process by activating on osteoclast differentiation.

Detecting Incipient Caries Using Front-illuminated Infrared Light Scattering Imaging

  • Kim, Ji-Young;Ro, Jung-Hoon;Jeon, Gye-Rok;Kim, Jin-Bom;Ye, Soo-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.6
    • /
    • pp.310-316
    • /
    • 2012
  • A new method for early caries diagnosis was proposed and tested through a home-made optical examination system that used quantitative light fluorescence (QLF) and digital imaging fiber optic transillumination (FOTI) (DIFOTI), with light sources across a wide spectral range, from 350 nm to 1,000 nm. The front-illuminated infrared light scattering image (FIR) showed similar diagnostic abilities to that of DIFOTI. The FIR method was invented based on the observation that caries lesions lose the high transmittance and low scattering properties of benign enamel tissue. There are various methods for the early diagnosis of caries, such as visual examination, exploration, X-ray radiography, QLF, FOTI, and infrared fluorescence (diagnodent). Among them, methods based on optical properties are regarded as having the most potential. A comparative study was performed between the FOTI, QLF, diagnodent, optical coherence tomography, and FIR scattering image methods, using 20 extracted teeth samples with early caries. A scale of lesion measurement based on optical image contrast was proposed. The statistical analysis showed a significant correlation between the DIFOTI and FIR methods (r = 0.35, p < 0.05). However, the QLF and diagnodent methods showed little association with FIR images, as they have different detection principles as compared with FIR. Tomographic images obtained by OCT, using 1,330 nm super luminescent LED as a gold standard of tooth structure, verified that the FOTI and FIR results correctly represented the lack of homogeneity in dental tissue. The newly proposed FIR method attained similar diagnostic results to those of FOTI, but with an easier approach.

Electronic and Magnetic Properties of Ti1-xMxO2-δ (M=Co and Fe) Thin Films Grown by Sol-gel Method

  • Kim, Kwang-Joo;Park, Young-Ran;Ahn, Geun-Young;Kim, Chul-Sung;Park, Jae-Yun
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.109-112
    • /
    • 2005
  • Electronic and magnetic properties of $Ti_{1-x}M_xO_{2-\delta}$ (M=Co and Fe) thin films grown by sol-gel method have been investigated. Anatase and rutile $Ti_{1-x}Co_xO_{2-\delta}$ films were successfully grown on $Al_2O_3$ (0001) substrates and exhibited p-type electrical conductivity while the undoped films n-type conductivity. Room temperature vibrating sample magnetometry measurements on the anatase and rutile $Ti_{1-x}Co_xO_{2-\delta}$ films with same x ($=4.8 at.{\%}$) showed quite similar magnetic hysteresis curves with the saturation magnetic moment of $\~4 {\mu}_B$ per Co ion despite their differences in structural and electronic properties. Such giant magnetic moment is attributable to the unquenched orbital moment of the $Co^{2+}$ ions substituting the octahedral $Ti^{4+}$ sites. Similar ferromagnetic behavior was observed for $Ti_{1-x}Fe_xO_{2-\delta}$ films that are highly resistive compared to the Co doped samples. Saturation magnetic moment was found to decrease for higher x, i.e., $\~2$ and $\~1.5 {\mu}_B$ per Fe ion for x=2.4 and 5.8 at. $\%$, respectively. Conversion electron $M\ddot{o}ssbauer$ spectroscopy measurements predicted the coexistence of $Fe^{2+}$ and $Fe^{3+}$ ions at the octahedral sites of $Ti_{1-x}Fe_xO_{2-\delta}$.

A STUDY ON THE ROOT CANAL MORPHOLOGY CHANGE BY NICKEL-TITANIUM AND STAINLESS STEEL FILE INSTRUMENTATION USING COMPUTERIZED TOMOGRAPHY (Nickel-Titanium file과 Stainless steel file을 이용한 근관형성시 컴퓨터 단층촬영사진상의 근관형태 변화에 관한 연구)

  • So, Mun-Seop;Im, Mi-Kyung;Lee, Keon-Il;Lee, Yong-Keun;Lee, Su-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.659-669
    • /
    • 1997
  • The goals of root canal instrumentation are complete debridement of pulp tissue, removal of microbes and affected dentin, and proper cleaning and shaping of the root canal space before obturation. Instrumentation with stainless steel files has been shown to produce undesirable results in canals, regardless of the improved technique or modified file type used. Nickel-Titanium(Ni-Ti) alloy has been shown to be exceptionally elastic, having a lower bending moment and lower permanent set after torsion, compared with similar gauge stainless steel. The purpose of this study was to evaluate the change of root canal prepared by Ni-Ti rotary and stainless steel instruments. Thirty-four single rooted teeth of similar shape and canal size were divided into three groups. The teeth were scanned by computed tomography before instrumentation. In group 1, canals were instrumented using a step-back technique with K-file. In group 2, canals were prepared with K-flex file using the same technique as group 1. Group 3 was prepared with nickel-titanium(Ni-Ti) rotary instrument using a manufacture's instruction. Instrumented teeth were again scanned using computed tomography, and reformated images of the uninstrumented canals were compared with images of the instrumented canals. K-flex file and Ni-Ti file caused significantly less canal transportation than K-file in the 8mm root canal section from the apex(p<0.05). K-flex file and Ni-Ti file produced more centered canal preparation than K-file in the 2mm section(p<0.05). Ni-Ti file maintained more precisely the center of the canal than K-flex file in the 10mm section (p<0.05). There was no difference in the removed volume of canals among each groups.

  • PDF

Establishment of Injection Protocol of Test Bolus for Precise Scan Timing in Canine Abdominal Multi-Phase Computed Tomography

  • Choi, Sooyoung;Lee, In;Choi, Hojung;Lee, Kija;Park, Inchul;Lee, Youngwon
    • Journal of Veterinary Clinics
    • /
    • v.35 no.3
    • /
    • pp.93-96
    • /
    • 2018
  • This study aimed to establish an injection protocol to determine the precise CT scan timing in canine abdominal multi-phase CT using the test bolus method. Three dynamic scans with different contrast injection parameters were performed using a crossover design in eight normal beagle dogs. A contrast material was administered at a fixed dose of 200 mg iodine/kg as a test bolus for dynamic scans 1 and 2, and 600 mg iodine/kg as a main bolus for dynamic scan 3. The contrast materials were administered with 1 ml/s in dynamic scan 1, and 3 ml/s in dynamic scan 2 and 3. The mean arrival time to the appearance of aortic enhancement in dynamic scan 3 was similar to that in dynamic scan 2, and different significantly to that in dynamic scan 1. The mean arrival time to the peak aortic and pancreatic parenchymal enhancement in dynamic scan 3 was similar to that in dynamic scan 1, and different significantly to that in dynamic scan 2. In multi-phase CT scan, a test bolus should be injected with the same injection duration of a main bolus, to obtain the precise arrival times to peak of arterial or pancreatic parenchymal enhancement.