• Title/Summary/Keyword: similar material

Search Result 3,185, Processing Time 0.035 seconds

Evaluation of the preservation state of human skeletal remains using real-time PCR (출토 인골 DNA의 real-time PCR 정량에 의한 보존상태 평가 연구 - 부여 오수리 출토 인골을 중심으로 -)

  • Kwon, Eun-Sil;Cho, Eun-Min;Kim, Sue-Hoon;Kang, Soyeong
    • 보존과학연구
    • /
    • s.32
    • /
    • pp.171-183
    • /
    • 2011
  • In this study molecular genetic analysis was carried out on 4 human skeletal remains from Osuri, Buyeo. We showed that real-time PCR is the method of the choice to assess the initial number of genuine ancient DNA molecules. Human mitochondrial DNA quantification was accomplished by the real-time PCR for the cytochrome b gene of the mitochondria. Histological results proved to be a good potentiality for biochemical analysis using biomolecule. The level of specimen's preservation state was proved that level of quantitative result was BO-04, BO-01, BO-03, BO-02. Continually, we showed that biochemical and biomolecule results for the level of preservation state were similar. This study will be useful to important material for predicting biochemistry and biology analysis of the ancient bone.

  • PDF

The Availability of Gore-Tex® Tube as Nerve Conduit at the Peripheral Nerve Defect (말초신경 결손시 신경도관으로서 Gore-Tex® 도관의 유용성)

  • Lee, Ki Ho;Oh, Sang Ha;Lee, Seung Ryul;Kang, Nak Heon
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.613-618
    • /
    • 2005
  • When a large peripheral nerve defect occurs, an autologous nerve graft is the most ideal method of recinstruction. But an autologous nerve graft has many limitations due to donor site morbidities. Many previous focused on finding the ideal nerve conduit. Among them, $Gore-Tex^{(R)}$ has several advantages over other conduits. It can be manipulated to a suitable size, does not collapse easily, and it is a semi- permeable material that contain pores. A round shaped nerve can be newly formed because of its smooth inner surface. The purpose of this study was to evaluate the availability of $Gore-Tex^{(R)}$ tube as a nerve conduit at the peripheral nerve defect in the rat sciatic nerve. The 10 mm nerve gap was made in each group. A $Gore-Tex^{(R)}$ tube filled with skeletal muscle was inserted and autologous nerve graft was harvested, respectively. In the experimental group, we placed a 0.5 mm thickness, $30{\mu}m$ pored, 1.8 mm in diameter and 14 mm length tube with skeletal muscle inserted inside. In the control group, the nerve gap was inserted with a rat sciatic nerve. We estimated the results electrophysiologically and histologically to 16 weeks postoperatively. Results in the nerve conduction velocity, total myelinated axon count, myelin sheath thickness and mean nerve fiber diameter, the experimental group was substantially lower than that of the control group, but the statistic difference was not significant (p<0.05). The morphology was very similar in both groups, microscopically. From the above results, We conclude that $Gore-Tex^{(R)}$ qualifies as an ideal nerve conduit. It is suggested that $Gore-Tex^{(R)}$ tube filled with skeletal muscle may, substitute for an autologous nerve graft.

The Usefulness of the Artificial Nail for Treatment of Fingertip Injuries (손가락끝 손상의 치료 시 인조손톱의 유용성)

  • Choi, Hwan-Jun;Kwon, Joon-Sung;Tark, Min-Seong
    • Archives of Plastic Surgery
    • /
    • v.37 no.6
    • /
    • pp.788-794
    • /
    • 2010
  • Purpose: The fingertip is the most commonly injured part of the hand and its injury frequently results in avulsion or crushing of a segment of the nail bed and fracture of the distal phalangeal bone. Restoration of a flat and smooth nail bed is essential for regrowth of a normal nail, which is important not only for cosmetic reasons but also for tactile capability of the fingertip. It is also anatomical reduction of the distal phalanx to promote patient's cosmetics and prevent nail bed deformity. Absence or no replacement of the nail plate results in obliterated proximal skin fold. When the avulsed nail plate cannot be returned to its anatomic position or when it is absent, we use a synthetic material for splinting the nail bed and alternative reductional method for distal phalangeal bone fracture, especially, instead of hardwares. Methods: From January of 2006 to June of 2009, a total of ten patients and fourteen fingers with crushing or avulsion injuries of the fingertip underwent using the artificial nails for finger splint. We shaped artificial nails into the appropriate sizes for use as fingernail plates. We placed them under the proximal skin fold and sutured to the fold proximally and to the lateral and medial edges of the nail bed or to the distal fingertip. Our splints were as hard as K-wire and other fixation methods and more similar to anatomic nail plates. Artificial nails were kept in place for at least 3 weeks. Results: No artificial nail related complication was noted in any of the ten cases. No other nail fold or nail bed complications were observed, except for minor distal nail deformity because of trauma. Conclusion: In conclusion, in order to secure the nail bed after injury and reduce the distal phalangeal bone fracture, preparing a nail bed splint from a artificial commercial nail is a cheap and effective method, especially, for crushed or avulsion injuries of the fingertip.

Evaluation of Modulus of Elasticity of Wood Exposed to Accelerated Weathering Test by Measuring Ultrasonic Transmission Time (촉진 열화 목재의 초음파 전달 시간 측정을 통한 탄성 계수의 평가)

  • Park, Chun-Young;Kim, Gwang-Chul
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.3
    • /
    • pp.275-281
    • /
    • 2014
  • In this study, accelerated weathering test was performed with wood, a major material for wooden cultural building. In order to evaluate the deterioration of wood, ultrasonic transmission times were measured to evaluate dynamic modulus of elasticity (MOE), which was verified by determining static MOE using three-point bending test. Ultrasonic transmission time was decreased with an increase in the weathering time levels (0, 500, 1000 hours) while it increased in 1500 and 2000 hours. Distribution of dynamic and static MOE was similar to that of the ultrasonic transmission time measurements. The results mean that the measurement of ultrasonic transmission time was very effective to evaluate MOE of wooden cultural buildings for their preservation and management. This method could be utilized to assess wooden cultural buildings as a way of preserving them in a scientific manner.

Synthesis of self-aligned carbon nanotubes on a Ni particles using Chemical Vapour Deposition

  • Park, Gyu-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.64-64
    • /
    • 2000
  • Since its discovery in 1991, the carbon nanotube has attracted much attention all over the world; and several method have been developed to synthesize carbon nanotubes. According to theoretical calculations, carbon nanotubes have many unique properties, such as high mechanical strength, capillary properties, and remarkable electronical conductivity, all of which suggest a wide range of potential applications in the future. Here we report the synthesis in the catalytic decomposition of acetylene at ~65 $0^{\circ}C$ over Ni deposited on SiO2, For the catalyst preparation, Ni was deposited to the thickness of 100-300A using effusion cell. Different approaches using porous materials and HF or NH3 treated samples have been tried for synthesis of carbon nanotubes. It is decisive step for synthesis of carbon nanotubes to form a round Ni particles. We show that the formation of round Ni particles by heat treatment without any pre-treatment such as chemical etching and observe the similar size of Ni particles and carbon nanotubes. Carbon nanotubes were synthesized by chemial vapour deposition ushin C2H2 gas for source material on Ni coated Si substrate. Ni film gaving 20~90nm thickness was changed into Ni particles with 30~90nm diameter. Heat treatment of Ni fim is a crucial role for the growth of carbon nanotube, High-resolution transmission electron microscopy images show that they are multi-walled nanotube. Raman spectrum shows its peak at 1349cm-1(D band) is much weaker than that at 1573cm-1(G band). We believe that carbon nanotubes contains much less defects. Long carbon nanotubes with length more than several $\mu$m and the carbon particles with round shape were obtained by CVD at ~$650^{\circ}C$ on the Ni droplets. SEM micrograph nanotubes was identified by SEM. Finally, we performed TEM anaylsis on the caron nanotubes to determine whether or not these film structures are truly caron nanotubes, as opposed to carbon fiber-like structures.

  • PDF

Tribology Characteristics in 300 μm of Hexagonal Array Dimple Pattern

  • Choi, H. J.;Hermanto, A. S.;Kwon, S. H.;Kwon, S. G.;Park, J. M.;Kim, J. S.;Chung, S. W.;Chae, Y. H.;Choi, W. S.
    • Tribology and Lubricants
    • /
    • v.31 no.6
    • /
    • pp.308-315
    • /
    • 2015
  • In the tribological performance of materials, a textured surface reduces the friction coefficient and wear. This study investigates the effects of a pattern of 300 µm dimples in a hexagonal array on the tribological characteristics. Previous studies investigated 200 µm dimples by using a similar material and method. There are three frictional conditions based on the Stribeck curve: boundary friction, mixed friction, and fluid friction. In this experiment, we investigated the frictional characteristics by conducting frictional tests at sliding speeds ranging from 9.6 rpm to 143.3 rpm and a normal load ranging from 13.6 N to 92 N. We used a photolithography method to create dimples for surface texturing. We used five specimens with different dimple densities 10%, 15%, 20%, 25%, and 30% in this study. The dimple density on the surface area is one of the important factors affecting the friction characteristics. The duty number graph indicates a fully developed fluid friction regime. Fluid friction occurs at a velocity of 28.7-143.3 rpm. We observed the best performance at a dimple density of 10% and a dimple diameter of 300 µm in the hexagonal array, the lowest friction coefficient at 0.0037 with 9.6 rpm 9.6N load, and the maximum friction coefficient at 0.0267 with 143.3 rpm 92N load.

Investigation on Explosion Bulge Test Results of 800 MPa Grade Pre-heat Free Welding Consumables (800 MPa급 무예열 용접재료의 폭파변형성능에 관한 연구)

  • Park, Tae-Won;Song, Young-Beum;Kim, Jin-Young;Park, Chul-Gyu;Kim, Hee-Jin
    • Journal of Welding and Joining
    • /
    • v.27 no.6
    • /
    • pp.80-86
    • /
    • 2009
  • The Cu-bearing PFS-700 steel which has yield strength over 700 MPa was developed to replace the existing submarine structural material, HY-100. The PFS-700 steel has a combination of good mechanical properties and superior weldability. Becaus of that, it can be welded without pre-heating. The application of PFS-700 steel to submarine or battle ship will give a great reduction of cost by omitting pre-heating or lowering pre-heat temperature. To develop pre-heating free welding consumables that match and take advantage of PFS-700 steel, new welding consumables have been designed for the GMAW, SAW processes and explosion bulge test(EBT) was conducted to see the reliability of welded structure. All welds were made without pre-heating, and the inter-pass temperature was below $50^{\circ}C$ for SAW50 and $150^{\circ}C$ for GMAW and SAW150. All EBT specimens show over 14% thickness reduction without through-thickness crack or crack propagation to the hole-down area. Tensile properties for all welding conditions show higher(GMAW) or similar values(SAW50, SAW150) to the base metal. Charpy impact values for the weld metal also show 163.5J(GMAW), 95.4J(SAW50) and 69.0J(SAW150), which meet the goal(higher than 50J) of this project.

Microstructure and Corrosion Behavior of Various Grain Size Cp-Ti (입자크기를 달리한 Cp-Ti의 미세구조 관찰 및 SBF하에서의 부식거동)

  • Lee Seung-Woo;Kim Yun-Jong;Ruy Jae-Gyeoung;Park Joong-Keun;Kim Won-Soo;Kim Taik-Nam
    • Korean Journal of Materials Research
    • /
    • v.15 no.9
    • /
    • pp.585-588
    • /
    • 2005
  • Titanium and Titanium alloys are widely used as an orthopedic and dental implant material because of their excellent biocompatibility and mechanical strength. In this study, ECAP Cp-Ti and Cp-Ti were heat treated for different annealing time of 30 min, 90 min and 3 hours. The grain size for each condition was studied. The micro-Vicker hardness test was carried out f3r each different heat treated samples. The micro-Vicker hardness test for ECAP Cp-Ti, Cp-Ti and Cp-Ti (3hr) revealed hardness values of 239.5, 182 and 144 Hv, respectively. The grain size was increased from approximately $70{\mu}m\;to\;300{\mu}m$ with the increase in heat treatment time from 30 min to 3 hours. The heat treated samples were tested for their biocompatibility in simulated body fluid (SBF) and corrosion rates was determined using Polarization Curve test (PCT). The PCT results showed Cp-Ti with comparatively high corrosion potential of -0.18 V and corresponding corrosion current of $2\times10^{-6}$ A, while the corrosion rate in ECAP Cp-Ti and Cp-Ti (30 min annealed) showed very similar results of corrosion potential about -0.47 V with corresponding corrosion current of $7\times10^{-8}$ A.

Characteristics of AlN Thin Films by Magnetron Sputtering System Using Reactive Gases of N2 and NH3 (N2와 NH3 반응성가스를 사용하여 마그네트론 스퍼터링법으로 제작한 AlN박막의 특성)

  • Han, Chang-Suk
    • Korean Journal of Materials Research
    • /
    • v.25 no.3
    • /
    • pp.138-143
    • /
    • 2015
  • Aluminum nitride, a compound semiconductor, has a Wurtzite structure; good material properties such as high thermal conductivity, great electric conductivity, high dielectric breakdown strength, a wide energy band gap (6.2eV), a fast elastic wave speed; and excellent in thermal and chemical stability. Furthermore, the thermal expansion coefficient of the aluminum nitride is similar to those of Si and GaAs. Due to these characteristics, aluminum nitride can be applied to electric packaging components, dielectric materials, SAW (surface acoustic wave) devices, and photoelectric devices. In this study, we surveyed the crystallization and preferred orientation of AlN thin films with an X-ray diffractometer. To fabricate the AlN thin film, we used the magnetron sputtering method with $N_2$, NH3 and Ar. According to an increase in the partial pressures of $N_2$ and $NH_3$, Al was nitrified and deposited onto a substrate in a molecular form. When AlN was fabricated with $N_2$, it showed a c-axis orientation and tended toward a high orientation with an increase in the temperature. On the other hand, when AlN was fabricated with $NH_3$, it showed a-axis orientation. This result is coincident with the proposed mechanism. We fabricated AlN thin films with an a-axis orientation by controlling the sputtering electric power, $NH_3$ pressure, deposition speed, and substrate temperature. According to the proposed mechanism, we also fabricated AlN thin films which demonstrated high a-axis and c-axis orientations.

Creep Analysis of Type 316LN Stainless Steel Using Reference Stress (참조응력을 이용한 316LN 스테인리스강의 크리프 해석)

  • Kim, Woo-Gon;Ryu, Woo-Seog
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.10
    • /
    • pp.2122-2129
    • /
    • 2002
  • Creep damage using a reference stress(RS) was analyzed for type 316LN stainless steel. The generalized K-R equation was reconstructed into the RS equation using a critical stress value $\sigma$. The RS equation was derived from the critical stress in failure time $t_f$ instead of material damage parameter $\omega$, which indicates the critical condition of collapse or approach to gross instability of materials during creep. For obtaining the reference stress, a series of creep tests and tensile tests were conducted with at 55$0^{\circ}C$ and $600^{\circ}C$. The stress-time data obtained from creep tests were applied to the RS equations to characterize the creep damage of type 316LN stainless steel. The value of creep constant r with stress levels was about 18 at 55$0^{\circ}C$ and 21 at $600^{\circ}C$. This value was almost similar with r = 24 in the K-R equation, which was obtained by using damage parameter $\omega$. Relationship plots of creep failure strain and life fraction $(t_f /t_r)$ were also obtained with different λ values. The RS equation was therefore more convenient than the generalized K-R equation, because the measuring process to quantify the damage parameter $\omega$ such as voids or micro cracks in crept materials was omitted. The RS method can be easily used by designers and plant operator as a creep design tool.