• 제목/요약/키워드: signal field

검색결과 2,140건 처리시간 0.033초

Research on the Correlation of Control Malfunction with Induced Voltage of Control Signal Line According to Voltage Change of a Power Line

  • Kang, Dong-Woo;Kim, In-Gun;Ham, Sang-Hwan;Kim, Sung-Yul;Bae, Sungwoo;Kim, Dae-Nyeon;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.775-780
    • /
    • 2016
  • This induced voltage measurement test and electromagnetic field simulation are related to the possibility of control signal malfunction by power line. Through an experiment, this research analyzed whether the voltage causing control malfunction according to the on/off status of power permitted to power line was induced to control signal line. Also, the research calculated the voltage induced to control signal line and examined the phenomenon by conducting an electro-magnetic field-specific simulation through the finite element method for the cable model used in the experiment.

Low Magnetic Field MRI Visibility of Rubber-Based Markers

  • Kim, Jeong Ho;Jung, Seongmoon;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.89-93
    • /
    • 2019
  • Purpose: This study aims to develop new markers based on silicone rubber and urethane rubber to enhance visibility in low magnetic field magnetic resonance (MR) imaging. Methods: Four types of markers were fabricated using two different base materials. Two of the markers were composed of two different types of silicone rubber: DragonSkin™ 10 MEDIUM and BodyDouble™ SILK. The other two markers were composed of types of urethane rubber: PMC™ 780 DRY and VytaFlex™ 20. Silicone oil (KF-96 1000cs) was added to the fabricated markers. The allocated amount of oil was 20% of the weight (wt%) of each respective marker. The MR images of the markers, with and without the silicone oil, were acquired using MRIdian with a low magnetic field of 0.35 T. The signal intensities of each MR image for the markers were analyzed using ImageJ software and the visibility for each was compared. Results: The highest signal intensity was observed in VytaFlex™ 20 (279.67±3.57). Large differences in the signal intensities (e.g., 627% in relative difference between BodyDouble™ SILK and VytaFlex™ 20) among the markers were observed. However, the maximum difference between the signal intensities of the markers with the silicone oil showed only a 62% relative difference between PMC™ 780 DRY and DragonSkin™ 10 MEDIUM. An increase in the signal intensity of the markers with the silicone oil was observed in all markers. Conclusions: New markers were successfully fabricated. Among the markers, DragonSkin™ 10 MEDIUM with silicone oil showed the highest MR signal intensity.

전기적으로 빠른 과도현상/버스트 신호의 복사방출과 대책 (Radiated Emission of Electrical Fast Transient/Burst Signal and Its Countermeasures)

  • 박수훈;김동일;박연준;나승욱
    • 한국전자파학회논문지
    • /
    • 제27권3호
    • /
    • pp.291-298
    • /
    • 2016
  • 본 논문에서는 전자파적합성 국제 규격인 IEC 61000-4-4에서 규정하고 있는 전기적으로 빠른 과도현상/버스트(EFT/Burst) 신호가 전원선을 따라 시험대상품에 인가될 때, 인가신호에 기인하여 방사되는 불요전자파와 그 신호가 피시험품에 미치는 영향에 대해 연구하였다. 먼저 국제규격에 규정된 시험 배치방법에 따라 시험 샘플을 설치하고, 검증된 EFT/Burst 발생기로 1분 동안 +4 kV의 규정된 신호를 길이 1 m인 전원선을 통해 시험 샘플에 인가하였다. 그 결과, 전원선을 통해 인가되는 전도성 EFT/Burst 내성 신호 외 버스트 발생기 및 전원선에서 직접 공기 중으로 방출되는 방사성 신호(EFT/Burst 노이즈)가 검출되었고, 국제 공인시험 규격으로 이 신호를 측정한 결과, 규제 레벨보다 30 dB 이상 높았다. 또한, EFT/Burst 방사성 신호의 최대 방사 지점과 시험품의 이격 거리에 따른 전계강도를 측정한 결과, 방사내성 국제 규격치보다 최대 23 V/m 이상 강한 전계강도가 검출되었다. 이는 EFT/Burst 방사성 노이즈가 직접적으로 제품에 인가되어 오동작을 유발할 가능성이 대단히 높으므로 대책이 요구됨을 확인하였다.

재료내 기공결함에 의한 SH형 초음파 원거리 산란장의 신호특성에 대한 수치해석 (Numerical Analysis on the Signal Characteristics for Scattered Far-field of Ultrasonic SH-Wave by the Internal Cavity)

  • 이준현;이서일;박윤원
    • 대한기계학회논문집A
    • /
    • 제24권1호
    • /
    • pp.163-172
    • /
    • 2000
  • In this study, the scattered far-field due to a cavity embedded in infinite media subjected to the incident SH-wave was calculated by the boundary element method. The effects of cavity shape and distance between internal cavity and internal point in infinite media were considered. The scattered far-field of the frequency domain was transformed into the signal of the time domain by using the Inverse Fast Fourier Transform(IFFT). It was found that the amplitude of scattered signal in time domain decreased with the increase of the distance between the detecting points of ultrasonic scattered field and the center of internal cavity in media. In addition, the time delay was clearly found in time domain waveform as the distance between the detecting points of ultrasonic scattered field and the center of internal cavity was gradually increased.

심자도 신호 검출을 위한 Flux Locked Loop (FLL) Emulation 회로 (Emulator Circuit for a Flux Locked Loop for Detection of Magnetocardiography Signal)

  • 안창범;이동훈;김인기;장경섭;김기태;정동현;최중필
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2749-2752
    • /
    • 2003
  • Magnetocardiography is a very weak biomagnetic field generated from the heart. Since the magnitude of the biomagnetic field is in the order of a few pico Tesla, it is measured with a superconducting quantum interference device (SQUID). SQUID is a transducer converting magnetic flux to voltage, however, its range of linear conversion is very restricted. In order to overcome the narrow dynamic range. a flux locked loop is used to feedback the output field with opposite polarity to the input field so that the total Held becomes zero. This prevents the operating point of the SQUID from moving too far away from the null point thereby escape from the linear region. In this paper, an emulator for the SQUID sensor and feedback coil is proposed. Magnetic courting between the original field and the generated field by the feedback coil is emulated by electronic circuits. By using the emulator, FLL circuits are analyzed and optimized without SQUID sensors. The emulator may be used as a test signal for multi-channel gain calibration and system maintenance.

  • PDF

AF궤도회로에서 에너지 밀도가 정보신호 검출시간에 미치는 영향 (The Influence of Energy Density upon Detection Time of Information Signal in AF Track Circuit)

  • 김민석;황인광;이종우
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1146-1151
    • /
    • 2011
  • There are two methods for train control in information transmission by using track circuit system and installing wayside transmitter. Information signal is transmitted to the on-board antenna by using rails. Continuous information about train intervals, speed and route is received by on-board antenna in AF track circuit system. The information signal is included with carrier wave and received by magnetic coupling in the on-board antenna. Therefore, it is important to define standard current level in the AF track circuit system. When current flowed to rails is low, magnetic sensors are not operated by decreasing magnetic field intensity. Hence, SNR is decreased because electric field intensity is decreased. When the SNR is decreased, there is the serious influence of noise upon demodulation. So, the frequency of information signal is not extracted in frequency response. Thus, it is possible to happen to train accident and delay as the information signal is not analyzed in the on-board antenna. In this paper, standard energy density is calculated by using Parseval's theory in UM71c track circuit. Hence, detection time of information signal is presented.

Modified Materka model를 이용한 GaN MODFET 대신호 모델링 ((GaN MODFET Large Signal modeling using Modified Materka model))

  • 이수웅;범진욱
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(2)
    • /
    • pp.217-220
    • /
    • 2001
  • Modified Materka-Kacprzak 대신호 MODFET(modulation-doped field-effect transistor) model을 사용하여 GaN(gallium nitride) MODFET 대신호 모델링을 수행하였다. Dambrine(3)이 제안한 방법에 따라 45㎒에서 40㎒의 주파수 범위에 걸쳐 S-parameter 및 DC특성을 측정하였으며, 측정결과를 토대로 cold FET 방법[4]에 의해 측정된 기생성분들을 de-embedding 함으로써 소신호 파라미터를 추출하였고, 추출된 소신호 파라미터는 함수를 사용하여 측정결과를 재현하는 맞춤함수 모델의 일종인 modified Materka 모델을 사용하여 모델링하였다. 수행된 대신호 모델링을 검증하기 위하여 모델링된 GaN MODFET의 DC 및 S-파라미터, 전력특성을 측정값과 각각 비교해 보았을 때 비교적 일치하고 있음을 보여서 GaN 대신호 모델링을 검증하였으며, modified Materka 모델이 GaN MODFET 대신호 모델링에 유용하게 사용될 수 있음을 보였다.

  • PDF

Rabi법 핵자기 공명에 의한 0.1 mT의 저자장 측정 (Low Fiele Measurement of 0.1 mT by Rabi's NMR Method)

  • 유권상;김철기;우병칠;김창석
    • 한국자기학회지
    • /
    • 제3권2호
    • /
    • pp.139-142
    • /
    • 1993
  • 고자장하에서 분극된 흐르는 물을 이용한 Rabi법 핵자기 공명신호 측정시스템을 구성하여, 이 시스템으로 0.1 mT의 저자장에서도 신호대 잡음비가 우수한 핵자기 공명신호를 얻을 수 있었다. RF 자장이 증가함에 따라 공명전이의 주기적인 변화에 의해 신호의 크기와 위상이 바뀌었으며, 최적화된 RF 조건에서 얻어진 공명신호로써 0.1 mT 자장영역까지 수십 ppm의 불확도내에서 자장을 측정할 수 있 었다.

  • PDF

Liquid-phase epitaxy로 성장시킨 A $I_x$Ga${1-x}$As(x.<=.0.15)의 photoreflectance (Photoreflectance of A $I_x$Ga${1-x}$As(x.<=.0.15) grown by liquid-phase epitaxy)

  • 배인호;김인수;이철욱;최현태;김말문;김상기
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제7권4호
    • /
    • pp.300-305
    • /
    • 1994
  • We determined the alloy composition of the liquid-phase epitaxy(LPE) grown $Al_{x}$G $a_{1-x}$ As by the photoreflectance(PR), and observed the variation of PR signal by changing the condition of annealing and thickness of epilayer. As the measuring temperature was decreased, the broadening parameter was decreased, and the amplitude of PR signal was increased. When the temperature of annealing was increased, the surface carrier concentration was decreased and then the shape and amplitude of PR signal were affected by the surface electric field. The structure change was observed when the specimen was annealed for long time at a high temperature. We found that the surface electric field increased when the thickness of epilayer was decreased by etching, because the band bending was increased by the decreased of the width of depletion layer....

  • PDF

FEM/EMTP를 이용한 GIS내 부분방전 펄스의 감쇠특성 해석 (Analysis of Partial Discharge Signal Propagation Characteristics in GIS Using FEM/EMTP)

  • 이도훈;이현동;신양섭;이용희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.255-257
    • /
    • 2004
  • This paper was studied electromagnetic field distribution and damping of PD(Partial Discharge) signal in GIS(Gas Insulated Switchgear). Cut-off frequency of electromagnetic wave propagation modes were computed, electromagnetic field distribution of propagation modes in GIS by FEM(Finite Element Method) were simulated and simulated damping characteristic of electromagnetic waves in GIS by EMTP(Electromagnetic Transient Program) when generated PD pulse. Frequency band of $TE_{mn}/TM_{mn}$ modes were determinated by simulation results of electromagnetic field distribution and were discussed optimal position of UHF sensor from this results. Equivalent circuit was used to simulate signal damping of PD pulse in GIS by EMTP and compared with measured results in laboratory of KERI.

  • PDF