• 제목/요약/키워드: signal field

검색결과 2,154건 처리시간 0.034초

Output Voltage Characteristics of HVDC Electric Field Mill Sensor for Different Speed Variables of Rotating Electrode

  • Kim, Young Sun;Park, Jae Jun
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.2001-2006
    • /
    • 2017
  • This paper explains the effects of the weak signal of a rotating-type electric field mill sensor fabricated for measuring the intensity of the electric field generated by high-voltage direct current (HVDC) power transmission lines. The fabricated field mill consists of two isolated electrode vanes, a motor driver, and a ground part. The sensor plate is exposed to and shielded from the electric field by means of a rotary shutter consisting of a motor-driven mechanically complementary rotor/stator pair. When the uncharged sensor plate is exposed to an electric field, it becomes charged. The rotating electrode consists of several conductive vanes and is connected to the ground part, so that it is shielded. Determining the appropriate design variables such as the speed of the vane, its shape, and the distance between the two electrodes, is essential for ensuring optimal performance. By varying the speed, the weak signal characteristics which is used to signal processing and calibration experiment are quite different. Each weak signal pattern was analyzed along with the output voltage characteristics, in order to be able to determine the intensity of the electric field generated by HVDC power transmission lines with accuracy.

자기공명영상 촬영 장치에서 다채널 RF Coil에 이용되는 기본 구조 RF Coil의 B1 Field 분석 (Basic RF Coils Used in Multi-channel RF Coil and Its B1 Field Distribution for Magnetic Resonance Imaging System)

  • 김용권
    • 한국산학기술학회논문지
    • /
    • 제11권12호
    • /
    • pp.4891-4895
    • /
    • 2010
  • 본 자기공명영상장치(MRI: Magnetic Resonance Imaging)의 구성 요소인 RF Coil의 성능은 영상의 신호대 잡음비(Signal to Noise Ratio)를 결정하는 장치이다. RF Coil의 성능은 민감도(Sensitivity)와 라디오주파수 필드 균질성(RF Field Uniformity)으로 나타내고, RF Coil에 의해 유기되는 라디오 주파수 자기장(B1 Field)의 세기는 RF Coil의 구조 및 배열에 따라 공간적으로 달라진다. MRI 신호의 크기는 RF Coil이 만들어내는 자기장의 세기에 의해 결정되기 때문에 RF Coil에 의해 형성되는 공간상의 B1 Field의 분포를 확인할 수 있어야 한다. 본 논문에서는 다채널 RF Coil 설계에 있어서 가장 기본이 되는 형태의 RF Coil 구조와 이의 B1 Field 분포를 Matlab을 이용하여 모의실험을 통해 확인 하였다. Matlab을 이용하여 계산된 기본 구조의 RF 코일이 형성하는 B1 Field 분포는 다채널 RF 코일 설계시 매우 유용하게 사용될 수 있을 것이다.

Time Stretched Pulse를 이용한 무향실 자유음장 분석 (Analysis of free field for Acoustic Anechoic Chamber based on Time Stretched Pulse)

  • 김건욱
    • 대한전자공학회논문지SP
    • /
    • 제49권4호
    • /
    • pp.111-119
    • /
    • 2012
  • Time Stretched Pulse (TSP)는 공간적으로 임펄스(Impulse)를 효율적으로 전달하고 분석하기 위해서 사용되어 진다. 하지만 발신기와 수신기의 전달함수를 포함시키지 않으면, 시간 영역에서의 분석은 직, 간접 신호의 중첩으로 공간의 자유음장 특성을 파악하기 불가능하다. 일반적으로 공간의 자유음장(Free Field)은 표준 ISO 3745 Annex A에 의해서 평가되고 있는데, 일정 주파수 간격의 1/3 옥타브 밴드 신호를 연속적으로 발신 및 수신하여 거리별 신호 감소를 역자승 법칙(Inverse Square Law)을 적용하여 판단하고 있다. 본 논문은 자유음장 분석에서 TSP 신호를 적용하여 일반적인 ISO 3745의 1/3 옥타브 밴드 신호와 비교하였다. 역자승 모델 값과의 차이점을 분석한 결과 TSP 신호 또한 1/3 옥타브 밴드 신호와 유사한 결과를 보이고 있으며, 측정 시간 및 확장성에 대해서는 우수하게 판단되었다. 본 실험에서는 ISO 3745에 의해서 제한된 주파수 범위에서 자유음장과 반자유음장(Hemi-free Field)을 검증 받은 무향실을 사용하였다.

A Shared Channel Design for the Power and Signal Transfers of Electric-field Coupled Power Transfer Systems

  • Su, Yu-Gang;Zhou, Wei;Hu, Aiguo Patrick;Tang, Chun-Sen;Hua, Rong
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.805-814
    • /
    • 2016
  • Electric-field coupled power transfer (ECPT) systems have been proposed as an alternative wireless power transfer (WPT) technology in recent years. With the use of capacitive plates as a coupling structure, ECPT systems have many advantages such as design flexibility, reduced volume of the coupling structure and metal penetration ability. In addition, wireless communications are effective solutions to improve the safety and controllability of ECPT systems. This paper proposes a power and signal shared channel for electric-field coupled power transfer systems. The shared channel includes two similar electrical circuits with a band pass filter and a signal detection resistor in each. This is designed based on the traditional current-fed push-pull topology. An analysis of the mutual interference between the power and signal transmission, the channel power and signal attenuations, and the dynamic characteristic of the signal channel are conducted to determine the values for the electrical components of the proposed shared channel. Experimental results show that the designed channel can transfer over 100W of output power and data with a data rate from 300bps to 120 kbps.

전력선 통신에서의 전자파 장해에 관한 연구 (A Study of Electromagnetic Interference in Power Line Communication)

  • 이진택;천동완;박영진;이원태;신철재
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권12호
    • /
    • pp.620-625
    • /
    • 2004
  • In this paper, we studied the emissive electric field due to the communication signal and the noise in medium voltage power-line. There are many types of conductive noise in power-line channel, which gives rise to radiation. And if the DMT carrier signal was excited, the current by this term was added to the current by noise and, generate radiation. We calculated input impedance by means of signal input network model of medium voltage power-line channel for calculating these currents. We calculated currents by input impedance and, calculated the emissive electric field by this calculated currents. From the measurement results, we knew that the measured results are very similar to the calculated results and if the input signal power level was higher than -40 dBm, the emissive electric field exceeds FCC radiation limit level 69.5 dB$\mu$V/m.

동물에서 자기 공명 영상 진단의 물리적 원리 (Physical Principles of Magnetic Resonance Imaging in Animal)

  • 김종규
    • 한국임상수의학회지
    • /
    • 제16권1호
    • /
    • pp.75-79
    • /
    • 1999
  • Magnetic resonance imaging (MRI) is an imaging technique used to produce high quality images of the inside of the animal body. MRI is based on the principles of nuclear magnetic resonance (NMR) and started out as a tomographic imaging technique, that is it produced an image of the NMR signal in a thin slice through the animal body. The animal body is primarily fat and water, Fat and water have many hydrogen atoms. Hydrogen nuclei have an NMR signal. For these reasons magnetic resonance imaging primarily images the NMR signal from the hydrogen nuclei. Hydrogen protons, within the body align with the magnetic field. By applying short radio frequency (RF) pulses to a specific anatomical slice, the protons in the slice absorb energy at this resonant frequency causing them to spin perpendicular to the magnetic field. As the protons relax back into alignment with the magnetic field, a signal is received by an RF coil that acts as an antennae. This signal is processed by a computer to produce diagnostic images of the anatomical area of interest.

  • PDF

Design of the Magnetic Field Sensing System for Downlink Signal Reception and Interference Cancelling for Through-the-Earth Communication

  • Zhao, Peng;Jiang, Yu-zhong;Zhang, Shu-xia;Ying, Wen-wei
    • Journal of Magnetics
    • /
    • 제21권3호
    • /
    • pp.330-339
    • /
    • 2016
  • A magnetic field sensing system with a single primary sensor and multiple reference sensors deployed locally and orthogonally, was proposed for downlink signal reception and interference cancelling for Through-the-Earth Communication (TEC). This paper mathematically analyzes a design optimization process for a search coil magnetometer (SCM), and applies that process to minimize the bandwidth of the primary SCM for TEC signal reception and the volume of reference SCMs for multiple distributions. The primary SCM achieves a 3-dB bandwidth of 7 Hz, a sensitivity threshold of 120 fT/${\surd}$Hz, and a volume of $2.32{\times}10^{-4}m^3$. The entire sensing system volume is as small as $10^{-2}m^3$. Experiments with interference from industrial frequency harmonics demonstrated an average of 36 dB and 18 dB improvements in signal-to-interference ratio and signal-to-interference plus noise ratio, respectively, using multichannel recursive-least-squares algorithm. Thus, the proposed sensing system can reduce the interference effectively and allows reliable downlink signal reception.

Treatment of Bone Repair by Inductively Magnetic Fields

  • 안재목;;김희찬;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.213-217
    • /
    • 1992
  • An inductively coupled magnetical signal (pulse wave, 0.7 to 60Hz, eighteen volts peak to Peak) that was applied non-invasively on the skin surface overlying the approximate site(measure position). In the group with unipolar pulse signal currents produced smaller than in the group with bipolar pulse signal. The signal was transmitted to the active coil, including a time-varying magnetic field: this in turn induced a the-varying electrical field in the field in the bone. It is very important to determine system parameters due to treatment time(healing) and the simplicity. This paper investigation was designed to compare the relative effects of pulsed unipolar currents with the effects of an identical pulsed bipolar currents. Since Inductive coupling is non-invasive and involves portable equipment, it is easy to apply and requires precise localization, it has distinct advantages and field characteristics along the bone for each different signal.

  • PDF

알루미늄 가공 현장에서 금속 불순물 검출 (Detection of Metal Impurities at Aluminum processing factory)

  • 황종명;안부환;이장명
    • 로봇학회논문지
    • /
    • 제4권4호
    • /
    • pp.320-326
    • /
    • 2009
  • This paper proposed a new magnetic field detection algorithm to detect metal pieces in food producing processes. This algorithm can detect mixed metal pieces by sensing magnetic field. Some metal pieces are passed through an over-current circuit to magnetize them. The magnetic field sensor can detect the change in the magnetic field on theconveyor belt caused by the flow of the metal pieces in the food product. However, such a method detects the output of signals that change their amplitude and phase according to the movement of the conveyor belt with the food product, in which the equilibrium of the positive signal that is created in the receiver coil loses its balance due to the magnetized material. This includes not only the signal elements resulting from the effect of the alternating magnetic fields of the mixed metals, but also the signal elements resulting from the effect of the alternating magnetic fields of the examined object itself.

  • PDF

근거리 환경에서의 3차원 배열센서 형상 보정 기법 (3-Dimensional Sensor Array Shape Calibration in Near Field Environment)

  • 류창수;어수해;강현구;유상욱
    • 한국산업융합학회 논문집
    • /
    • 제6권4호
    • /
    • pp.361-366
    • /
    • 2003
  • Most sensor array signal processing methods for multiple source localization require knowledge of the correct shape of array(the correct positions of sensors that consist array), because sensor position uncertainty can severely degrade the performance of array signal processing. In particular, it is assumed that the correct positions of the sensors are known, but the known positions may not represent the true sensor positions. Various algorithms have been proposed for 2-D sensor array shape calibration in far field environment. However, they are not available in near field. In this paper, 3-D sensor array shape calibration algorithm is proposed, which is available in near field.

  • PDF