• 제목/요약/키워드: side wood

검색결과 147건 처리시간 0.027초

한옥건축물의 건조방법에 따른 외진 노출 기둥의 함수율 및 균열 양상에 관한 연구 (A Study on the Moisture Content and Cracking Behavior of out side Exposed columns According to Drying Methods of Hnaok Buildings)

  • 김윤상
    • 한국농촌건축학회논문집
    • /
    • 제21권1호
    • /
    • pp.37-44
    • /
    • 2019
  • Recently, various tourist products using hanok have increased rapidly. In the meantime, there is a steady demand for Hanok architecture. However, there are many negative perceptions about wood deformation and biodeterioration. Wood deformation and biodeterioration are related to moisture content. And the cracks occur in the process of removing water from the wood. Therefore, this study investigates the moisture content and cracks of dried hanok made of wood according to the drying method of wood. Drying methods include natural seasoning and artificial seasoning. There was a difference in moisture removal depending on drying period and method of natural seasoning. Drying time should be about 3 years for natural seasoning, so the moisture content of the wood is stable. In addition, the moisture absorption rate was low even in a humid environment where the voids were removed. However, natural seasoning is time consuming. Artificial seasoning, on the other hand, can quickly remove moisture from the wood and reduce porosity, but it is costly. Cracks that occur during the drying of wood may become problematic in appearance and stability due to wider spacing over time. As a result, the difference in the moisture content of the timber depending on the drying method and drying period of the wood was maintained even after the formation. These gaps appeared to be differences in moisture absorption in a wet environment.

백합나무 바이오오일에서 회수한 열분해리그닌(Pyrolytic Lignin)의 화학적 특성 (Characterization of Pyrolytic Lignin in Biooil Produced with Yellow Poplar (Liriodendron tulipifera))

  • 김광호;문선주;김태승;이수민;여환명;최인규;최준원
    • Journal of the Korean Wood Science and Technology
    • /
    • 제39권1호
    • /
    • pp.86-94
    • /
    • 2011
  • 열분해 온도와 체류시간을 달리하며 급속 열분해 공정을 통해 얻어진 백합나무 바이오오일로부터 분말 형태의 열분해리그닌(pyrolytic lignin)을 회수하였다. 바이오오일을 구성하고 있는 열분해리그닌의 특성을 이해하고 급속 열분해 실험 조건 - 반응 온도, 체류시간 - 이 열분해 과정에서 리그닌에 미치는 영향을 살펴보기 위해 수율을 비롯한 다양한 화학적, 구조적 분석을 수행하였다. 열분해 온도가 증가하고, 체류시간이 줄어들수록 바이오오일로부터 회수되는 열분해리그닌의 수율은 증가하였다. 열분해리그닌의 분자량은 백합나무 MWL (milled wood lignin)에 비해 1/10 수준인 약 1,200 mol/g로 측정되었다. 열분해리그닌 내 포함된 작용기 함량과 $^{13}C$ NMR 분석을 통해 바이오매스가 열분해되는 동안 탈메톡실화 반응과 리그닌의 propane side chain 분해반응이 우세하게 일어난다는 사실을 확인하였다.

낙엽송(落葉松) 추출성분(抽出成分) 이용(利用)에 관(關)한 기초연구(基礎硏究) (Studies on the Characteristics of Extractives in Japanese Larch (Larix leptolepis Gordon) Grown in Korea)

  • 조남석;이종윤;안원영
    • Journal of the Korean Wood Science and Technology
    • /
    • 제10권2호
    • /
    • pp.12-21
    • /
    • 1982
  • Red pine and Japanese larch (Larix leptolepis Gordon) grown in Korea have been the main species of coniferous resources in Korea. Especially, planting area of Japanese larch has been increased continueously in the recent years due to its superior plant type and rapid growth rate and its stocks reached approximately 4.32 million cubic meters at the present time. Although many research works have been done for the utilization of the larch wood in various ways, still many problems are existed in its chemical applications due to a large proportion of soluble extractives. In this study, chemical composition of larch extractives and chemical structure of its major component were analyzed. In order to identify the basic structure of major component, gas-liquid chromatography for separation of some completely methylated alditols as their acetates on a 3% - ECNSS-M on Gas Chrom Q. column was used. Proportion of extractives of Japanese larch wood was higher than that of other conifers and major component of the soluble extractives was arabinogalactan, a schematic structural formula which was presented in Figure 2. The molar ratio of arabinose and galactose was 1:4.5. The main chain of arabinogalactan was composed of 1,3 linked ${\beta}$-D-galactopyranose residues, each of which carried a side chain, attached to the C-6 positions. The exact nature of all of the side chains is not known, but the majority of these side chain was composed of 1, 6 linked ${\beta}$-D-galactopyranose residues, with 2~3 such units present per average chain. Some of the galactose units in the main chain had a residue of 3 - 0 - ${\beta}$-L-arabinopyranosyl-L-arabinofuranose. In addition, a few terminal residues of D-glucuronic acid also was confirmed, attached to C-6 position of the D-galactopyranose residue. It could concluded that the main structure of highly branched arabinogalactan from Japanese larch extractive was essentially the same as those of the other larch species.

  • PDF

Characteristics of sawdust, wood shavings and their mixture from different pine species as bedding materials for Hanwoo cattle

  • Ahn, Gyu Chul;Jang, Sun Sik;Lee, Kang Yeon;Baek, Youl Chang;Oh, Young Kyoon;Park, Keun Kyu
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제33권5호
    • /
    • pp.856-865
    • /
    • 2020
  • Objective: This study was conducted to evaluate the physicochemical properties and changes in moisture concentrations of bedding materials under the conditions of rearing Korean Hanwoo cows. Methods: Two experiments were conducted to investigate the physicochemical characteristics (Exp. I) and usefulness as beddings for rearing cattle (Exp. II) by the type of beddings such as sawdust (SD), wood shavings (WS) and sawdust+wood shavings (S+W; 1:1 in volume), and the species of pine trees from different countries of origins (China, Pinus armandii, AR; Vietnam, Pinus kesiya, KE; USA, Pinus rigida, RI). Results: In Exp. I, SD-AR showed the largest proportion (78.3%) of fine particles (250 ㎛+below 250 ㎛) and the highest bulk density (208 kg/㎥) among treatments (p<0.05). The water absorption capacity at 24 h of both S+W-RI (713%) and -KE (701%) was the highest among treatments (p<0.05) and higher than those of SD or WS alone within each species of pine tree (p<0.05). Moisture evaporation rates (%) at 12 h were ranged from 52.3 to 60.8 for SD, 69.9 to 74.4 for WS, and 72.3 to 73.5 for S+W. Total amounts (mg/㎡) of ammonia emissions were the lowest (p<0.05) in KE species among the pine species within each type of bedding material, having higher ability of ammonia absorption. In Exp II, KE species in both side A and B had lower moisture concentrations (%) than other species. Regardless of types of beddings except SD-AR, moisture concentrations of beddings within a pen were higher (p<0.01) at side A than B. Conclusion: The KE species has better physical characteristics than other beddings and more useful for rearing Hanwoo cattle than other beddings, probably caused by the differences in the method and degree of wood processing rather than the species.

중인방을 포함한 목골조 경량벽체의 내화성능에 관한 연구 (A Study on the Fire Resistance Performance of Wood Framed Lightweight Wall which Including a Middle Lintel)

  • 여인환;조범연;민병렬;윤명오
    • 한국화재소방학회논문지
    • /
    • 제25권3호
    • /
    • pp.91-98
    • /
    • 2011
  • 이 연구는 전통 벽체 형식으로서 중인방을 포함한 목골조 경량벽체의 내화성능에 대한 것이다. 대상으로 한 경량벽체는 $38{\times}89$ mm($2"{\times}4"$) 목재를 골구로 하고 방회석고보드로 마감하는 형식의 비내력구조 이다. 벽체의 중간부에는 $150{\times}150$ mm 단면의 집성목 중인방을 설치하였다. 실험체는 단열재 유무 등에 따라 3가지 타입으로 제작하였다. 내화실험 결과 실험체-1, 2, 3 모두 90분 이상의 내화성능을 확보하는 것으로 나타났고, 각각 92분, 98분, 99분만에 중인방의 측면과 하부에서 불꽃이 발생하여 실험을 중단하였다. 가열면의 방화석고보드($12.5mm{\times}2$겹)는 약 45분간 내화성능을 유지하는 것으로 나타났고, 중인방의 연소는 일반적인 목재의 탄화속도와 유사한 거동을 보였다 벽체 내부의 목재스터드는 방화석고보드의 기여로 연소가 지연되는 동안 탈수가 일어나 고온에 노출된 이후에는 수분에 의한 온도상승 지연효과가 일어나지 않고 비교적 빠른 연소가 진행되는 것으로 나타났다.

목질판상재로 제조된 탄화보드의 흡방습 성능 비교 (Comparison of Moisture Absorption/Desorption Properties of Carbonized Boards Made from Wood-Based Panels)

  • 이민;박상범;이상민
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권3호
    • /
    • pp.424-429
    • /
    • 2016
  • 본 연구에서는 중밀도섬유판, 파티클보드, 배향성스트랜드보드, 합판을 이용하여 탄화보드를 제조하고 각각의 흡방습 특성을 살펴보았다. 탄화보드는 $600^{\circ}C$에서 2시간 동안 열분해하는 조건으로 제조되었다. 그 결과, 탄화합판, 탄화OSB, 탄화MDF, 탄화파티클보드 순으로 높은 흡방습 성능을 나타내었다. 흡습률 및 방습률은 탄화파티클보드를 제외한 나머지 탄화보드들 간에 큰 차이는 발견하지 못했다. 이것은 목질재료가 탄화됨으로서 탄소로 변환되어 수분을 흡착하는데 높은 능력을 가졌지만 수분이 내부구조로까지의 이동에 있어서는 목재 본래의 구조에 영향을 받는다는 것을 의미한다. 따라서 목재의 구조의 특성을 살려 탄소화 했을 때 높은 흡방습 특성을 가진 탄화보드를 제조할 수 있다.

Bending Creep Properties of Cross-Laminated Wood Panels Made with Tropical Hardwood and Domestic Temperate Wood

  • PARK, Han-Min;GONG, Do-Min;SHIN, Moon-Gi;BYEON, Hee-Seop
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권5호
    • /
    • pp.608-617
    • /
    • 2020
  • For efficient use and expansion of domestic small- and medium-diameter woods, cross-laminated wood panels composed of tropical hardwoods and domestic temperate woods were fabricated, and the bending creep behavior under long-term loading was investigated. The bending creep curve of the cross-laminated wood panels showed an exponential function graph with a sharp increase at the top right side. The wood panel composed of a teak top layer and larch core and bottom layers recorded the highest initial deformation, and that composed of a merbau top layer and tulip core and bottom layers showed the lowest initial deformation. Creep deformation of the cross-laminated wood panels showed the highest value in that composed of a teak top layer and larch core and bottom layers and showed the lowest value in that composed of a merbau top layer and tulip core and bottom layers. The obtained creep deformation is 3.1-4.3 times that of merbau, however, it is remarkably lower than that of tulip and larch. The highest relative creep was recorded by the wood panel composed of merbau top layer and larch core and bottom layers, whereas that composed of the teak top layer and tulip core and bottom layers showed the lowest relative creep.

자연환경에 노출된 CCA 방부목재로부터 크롬, 구리 및 비소의 용탈 특성 (Characteristics of the release of chromium, copper, and arsenic from CCA-treated wood exposed to the natural environment)

  • 구진회;송병열;김희갑
    • 분석과학
    • /
    • 제21권1호
    • /
    • pp.1-8
    • /
    • 2008
  • 이 연구에서는 chromated copper arsenate(CCA)로 처리된 방부목재가 실외환경에 노출될 때 금속들의 용탈 특성을 알아보았다. CCA 방부목재를 수평 또는 토양에 묻은 채 수직으로 1년 동안 노출시켰다. 수평으로 노출된 목재의 옆면에서 매월 드릴로 목재 시료를 채취하였고, 노출이 종료된 후에는 톱밥 시료를 채취했다. 수직으로 노출시킨 목재 주변에서는 표토를, 그리고 깊이별로 토양 시료를 채취하였다. 채취한 시료는 원자흡광광도계(AAS)로 분석하였다. 목재 표면 부위에서의 농도는 강우에 따라 매월 변하였고, 목재가 수평으로 노출된 경우보다는 수직으로 노출된 경우 금속들이 더 많이 용탈되었다. 비소의 경우에는 노출 전에 비해 80 % 정도까지 용탈되었다. 또한 지상보다는 지하 부위에서 더 많이 용탈되었으며, 수직으로 세운 말뚝 주변의 토양은 금속으로 오염되었다.

마이크로파 가열에 의한 소나무재의 곡가공 (Bending of Korea red pine (Pinus densiflora) by Microwave Irradiation)

  • 정승수;이원희
    • Journal of the Korean Wood Science and Technology
    • /
    • 제27권3호
    • /
    • pp.17-22
    • /
    • 1999
  • 본 연구에서는 목재 곡가공에서 마이크로파 조사 열의 효과를 조사했다. 마이크로파로 조사된 시험편은 대철과 클램프를 이용하여 곡가공을 행했다. 시험을 위한 시험편, 소나무 (Pinus densiflora), 은 78시간 동안 물에 침지했다. 포화된 시험편은 1시간 동안 자비되었다. 시험편의 크기는 $350mm(L){\times}20mm(R){\times}10mm(T)$이며, 이를 시험편은 2,450MHz 의 주파수를 가지는 마이크로파로 가열되었다. 가장 적당한 마이크로파 조사 시간은 60~90초 범위가 적당한 것으로 보였다. 함수은은 조사 시간의 증가와 함께 뚜렷이 감소했다. 연화된 목재를 곡가공 할 때, 연화된 시험편의 철면 (凸面)은 인장되고, 요면(凹面)은 압축 되었다. 압축부는 상당히 압축이되나, 인장부는 매우 작았다. 따라서 파괴는 인장 파괴 변형에 의해서 일어날것이고, 철면에서 대부분 발생한다. 그래서 다음과 같은 3가지 서로 다른 방식에 따라 결과를 얻었다. 1) 대철을 이용하여 곡가공 할 때, 철면에서는 인장 파괴가 일어나지 않지만, 요면에서 압축 파괴가 일어났다. 2) 클램프를 이용하여 곡가공 할 때, 대철 보다 곡가공 시간이 증가 했고, 인장 파괴가 발생했다. 3) 대철과 클램프를 이용한 곡가공은 본 연구에서 가장 우수한 조작으로 나타났다.

  • PDF

산업용 규모의 압체고주파진공건조시스템 성능 평가 (Performance of a Commercial Scale Radio-frequency/vacuum Dryer Combined with a Mechanical Compressive Load)

  • 이남호;;황의도;장세환;신익현
    • Journal of the Korean Wood Science and Technology
    • /
    • 제37권3호
    • /
    • pp.192-199
    • /
    • 2009
  • 본 연구에서는 수용재적 약 $3m^3$ 크기의 압체고주파진공건조시스템을 이용하여 Azobe (Lophira alata)와 국산 소나무(Pinus densiflora) 제재목을 건조하면서 건조시스템의 성능을 평가하였다. 압체고주파진공건조기의 진공도는 80~105 mbar를 유지시켰고, 건조 중 재온은 건조초기 $40^{\circ}C$에서 시작하여 건조말기 $60^{\circ}C$까지 상승시켰다. 全건조기간에 걸쳐 기전전극판측의 재온은 제어온도보다 항상 높게 유지되는 반면, 접지전극판측의 재온은 항상 낮게 유지되었다. 건조시간이 경과함에 따라 접지전극판측의 재온은 제어온도보다 더욱 낮고 기전전극판측의 재온은 제어온도보다 더욱 높게 나타났다. Azobe의 경우 입력포트측의 평균최종함수율보다 입력포트반대측의 평균최종함수율이 모든 잔적층에서 미미하게 높게 나타났으며, 잔적층의 수직방향으로의 최종함수율은 기전전극판측에서 접지전극판측을 향할수록 높게 나타났다. 기전전극판과 인접한 잔적층의 경우 재목당 평균할렬의 발생길이가 매우 경미하였으나, 접지전극판측을 향할수록 증가하는 경향을 보였다. 또한 투입된 에너지의 효율면에 있어 선진국의 상용설비와 유사한 수준을 보여 주는 것으로 평가되었다.