• 제목/요약/키워드: shunt

검색결과 1,338건 처리시간 0.031초

Computation of the Current Limiting Behavior of BSCCO-2212 High-Temperature Superconducting Tube with Shunt Coils

  • Kim, H.M.;Park, K.B.;Lee, B.W.;Oh, I.;Sim, J.;Hyun, O.B.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권4호
    • /
    • pp.22-25
    • /
    • 2006
  • This paper deals with the computation of the current limiting behavior of high-temperature superconducting (HTS) modules for the superconducting fault current limiter (SFCL). The SFCL module consists of a monofilar type BSCCO-2212 tube and a shunt coil made of copper or brass. The shunt coil is connected to the monofilar superconducting tube in parallel. Through analysis of the quench behavior of the monofilar component with shunt coils, it is achieved to drive an equivalent circuit equation from the experimental circuit structure. In order to analyze the quench behavior of the SFCL module, we derived a partial differential equation technique. Inductance of the monofilar component and the impedance of the shunt coil are calculated by Bio-Savart and Ohm's formula, respectively. We computed the quench behavior using the calculated values, and compared the results with experimental results for the quench characteristics of a component. The results of computation and test agreed well each other, and it was concluded that the analytic result could be applied effectively to design of the distribution-level SFCL system.

Juxtaductal stenosis가 동반된 PA/VSD환자에서 체폐단락술 부위에 따른 폐동맥 크기의 변화 (Pulmonary Arterial Growth Pattern after Shunt Operation in Patients of Pulmonary Atresia with Ventricular Septal Defect Associated with Juxtaductal Stenosis)

  • 이교준;박영환;최재영;조범구
    • Journal of Chest Surgery
    • /
    • 제31권9호
    • /
    • pp.861-866
    • /
    • 1998
  • 심실중격결손이 동반된 폐동맥폐쇄(PA/VSD)는 폐동맥의 형태 및 공급원이 매우 다양하고, 폐동맥의 발육부전 과 협착 및 폐동맥지 연결이상 유무가 교정수술시의 문제점으로 대두되고 있으므로, 저자들은 동맥관인접협 착(juxtaductal stenosis)이 동반되어 있는 환자들을 대상으로 체폐단락술전후 폐동맥 크기의 변화를 비교하 여, 수술방법 및 시기를 결정하는데 도움이 되고자 본 연구를 하였다. 1991년 7월부터 1996년 7월까지 연세대 학교 심장혈관센터에서 심실중격결손이 있는 폐동맥폐쇄환자중 동맥관인접협착이 동반되어 체폐단락술을 시행 한 59례가 있었으며, 수술전후의 심도자술 및 심혈관조영술을 시행한 29례를 대상으로 하였다. 우측(10례, Group I) 및 좌측단락술(19례, Group II)에서 단락술전후의 하행대동맥, 양측폐동맥 및 동맥관인접협착 부위의 직경을 측정하여, 수술부위에 따른 수술전후 변화를 비교하였다. 두 군에서, 하행대동맥직경에 대한 동측 폐동 맥직경의 비(ratio)가 수술전 0.78$\pm$0.31에서 수술후 1.01$\pm$0.26로, 또한 수술전 0.67$\pm$0.18에서 수술후 0.84$\pm$ 0.27로 각각 유의하게 증가하였으며, 편측 폐동맥직경의 비는 수술전 0.92$\pm$0.28에서 수술후 1.05$\pm$0.15로, 또한 수술전 0.94$\pm$0.27에서 수술후 1.08$\pm$0.37로 각각 증가하였으나 통계학적으로 유의하지는 않았다. 동맥관 인접협착 부위의 변화는 수술전 0.43$\pm$0.27에서 수술후 0.39$\pm$0.25로, 또한 수술전 0.32$\pm$0.10에서 수술후 0.30$\pm$0.16로 감소하는 경향을 보였으나 통계학적으로 유의하지 않았으며, 2례의 경우에서는 수술후 단절된 소견을 보였다. 체폐단락술을 통한 폐동맥혈류의 확보는 폐혈관 성장에 좋은 효과가 있으므로 폐혈류 감소 및 폐동맥 발육부전환자에서 추천되는 치료법이나 심실중격결손을 동반한 폐동맥폐쇄의 경우에는 동맥관인접협착의 변화가 중요한 것으로 생각된다. 본 연구 결과에서는 체폐단락술을 시행한 동측의 폐동맥이 성장함을 확인할 수 있었고, 동맥관인접협착은 악화될 가능성이 있는 것으로 생각되었다. 또한, 좌측 체폐단락술을 시행하여, 2례의 좌측 폐동맥의 단절을 경험하였다. 그러므로, 체폐단락술을 시행한 경우에는, 보다 철저한 술후 추적 및 검사가 요구되며, 동맥관인접협착이 동반된 측의 폐동맥에 단락술을 시행한 경우에는 조기에 완전 교정술을 고려하여야 할 것으로 사료된다.

  • PDF

Internal shunt를 이용한 총경동맥협착 수술치험 -1례 보고- (Carotid Endarterectomy for Common Carotid Artery Stenosis Using Internal Shunt -A Report of Case-)

  • 조용길
    • Journal of Chest Surgery
    • /
    • 제28권3호
    • /
    • pp.324-327
    • /
    • 1995
  • Extracranial carotid artery disease is rare and closely related to cardiovascular morbidity and mortality.We experienced one case of surgical treatment of left common carotid artery stenosis using internal shunt.The patient was 54-year-old female presented as headache and dizziness for about 2 years.On Doppler ultrasound, an atheromatous plaque was noted along the posteromedial wall of left common carotid artery resulting in luminal narrowing in about 75s of cross section area.The atheroma was resected through carotid endarterectomy, measured about 5.2cm in length. Postoperative course was uneventful and she was discharged in good condition.

  • PDF

OPF를 이용한 중장기 전력계통 조상설비 계획수립 (Long-term Shunt VAr Planning using Optimal Power Flour)

  • 유헌수;배주천
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.301-303
    • /
    • 2005
  • This paper presents long-term shunt capacitor planning using optimal power flow. OPF allows the planning engineer to find feasible solution with minimal amount of engineering time. We used OPF for Shunt capacitor planning to get an optimal solution. The result of OPF is compared to the analysis by the conventional loadflow method and it is proved that OPF gives more cheaper and better planning solution. With the result, we analyzed the operational perspective for the reactive power supply and demand.

  • PDF

Malignant Ascites after Subduroperitoneal Shunt in a Patient with Leptomeningeal Metastasis

  • Lee, Min-Ho;Lee, Jung-Il
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권4호
    • /
    • pp.385-387
    • /
    • 2011
  • Leptomeningeal metastasis is a devastating complication of advanced stage cancer. It is frequently accompanied by hydrocephalus and intracranial hypertension that must be treated by ventriculoperitoneal shunts. However, there are actual risks of peritoneal seeding or accumulation of malignant ascites after the cerebrospinal fluid diversion procedure, though it has not been reported. Here, we present the case of a patient with non-small cell lung cancer with leptomeningeal metastasis in whom malignant ascites developed after a subduroperitoneal shunt.

션트저항을 통한 박막형 초전도 한류기의 전압등급 증대 (Increase of voltage ratings in the superconducting fault current limiter using thin films by shunt resistors)

  • 최효상;김혜림;황시돌;박권배;현옥배
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.176-177
    • /
    • 2001
  • Three nearly identical superconducting fault current limiters (SFCLs) were connected in series to increase the voltage ratings. A slight difference in the quench starting point of individual SFCL units produced significantly imbalanced power distribution when connected in series. The imbalance was successfully removed by connecting a shunt resistor to one SFCL in parallel. 1.2 kV SFCL was designed with five current limiting elements and two or three shunt resistors.

  • PDF

싸이리스터 제어 병렬 보상기에 의한 전력 제어 연구 (Power Flow Control of Thyristor Controlled Shunt Compensator)

  • 정교범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.680-683
    • /
    • 1999
  • A thyristor controlled shunt compensator, which is installed in the middle of the transmission line is adopted for controlling real power flow in a simple power transmission system. By means on the Fourier series representation of the thyristor switching action and the system parameters, the thyristor current equations are derived, which transmit the required real power of the simple power transmission system and inform the thyristor firing angle, the thyristor conduction angle, the power flows and the harmonic characteristics EMTP simulations at the various operating points show the dynamic characteristics of the thyristor controlled shunt compensator and correspond to the results calculated with the Fourier series representation.

  • PDF

SERIES-SHUNT 다이오드를 이용한 8㎓ SPST SWITCH (8㎓ SPST SWITCH USING SERIES-SHUNT DIODE)

  • 권우성;임준열;임정현;김범만
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2002년도 종합학술발표회 논문집 Vol.12 No.1
    • /
    • pp.352-355
    • /
    • 2002
  • 본 논문에서는 series-shunt type의 PIN diode를 사용하여 8 ㎓ (7.7㎓ - 8.3㎓) 에서 사용 가능한 switch를 설계 제작하였다 스위치의 중요한 사양인 격리도 (-50㏈ 미만) 삽입손실(-1.5㏈ 미만) 입력전력 허용치 (평균전력 0.5 watt 이상 ) 입출력 정재파비 (1.3:1) 등을 고려하여 설계하였으며, 제작은 인텍웨이브사의 알루미나 기판을 이용한 thin film 공정을 이용하였으며, 측정 또한 이 네 가지에 중점을 두었다. 격리도는 중심 주파수 근방에서 비교적 넓은 대역을 가지고 -50㏈ 미만이었으며, 삽입손실은 -1.3㏈-1.6㏈였다. 입출력 정재파비는 1 -1.4였다.

  • PDF

뇌실복강간단락술 원위 도관에 의한 구불결장의 천공 (Sigmoid Colon Perforation by a Distal Ventriculoperitoneal Shunt Catheter)

  • 신동근;김성호
    • Journal of Yeungnam Medical Science
    • /
    • 제25권2호
    • /
    • pp.171-174
    • /
    • 2008
  • We report an unusual case of a sigmoid colon perforation after ventriculoperitoneal shunt surgery. Distal catheters are known to cause perforation in the setting of colonoscopy. The exact pathogenesis of this complication is not clear, but it can cause serious complications. Hence, patients require prompt and aggressive management, including laparotomy with bowel wall repair, catheter removal, and antibiotic therapy.

  • PDF

직류 분권전동기의 속도 특성 (Speed Characteristics of Direct Current Shunt Motors)

  • 신명호
    • 조명전기설비학회논문지
    • /
    • 제26권3호
    • /
    • pp.69-72
    • /
    • 2012
  • It is well known that speed of a direct current shunt motor is inverse proportional to flux. This paper presents speed expression to show that speed is not inverse proportional to flux. The presented speed vs. flux curves are verified by experimental result that shows the need of the revision of speed vs. flux curves shown in conventional text books.