• Title/Summary/Keyword: shunt

Search Result 1,335, Processing Time 0.028 seconds

An Unequal Divider based on Transmission Line with Periodic Capacitor Shunt Connection (캐패시터가 주기적으로 병렬 연결된 전송선로를 이용한 비대칭 분배기)

  • Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.5
    • /
    • pp.781-786
    • /
    • 2012
  • In this paper, we propose the design and performance of an unequal divider using transmission line with periodic capacitor shunt connection. To design divider with a high dividing ratio, we limit a high impedance line value to fabricate microstrip line and also, design a low impedance line of below $10{\Omega}$ using periodic capacitor shunt connection. As a design example, a 10:1 ratio divider was designed and measured at center frequency 1 GHz to show the validity of the unequal divider using periodic capacitor shunt connection. Its performance is in good agreements with the simulated results.

Changes in Pressure-Flow Control Characteristics of Shunt Valves by Intracranial Pressure Pulsation: an In Vitro Study

  • Lee, Chong-Sun;Kim, Joo-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.4
    • /
    • pp.193-197
    • /
    • 2005
  • Shunt valves used to treat patients with hydrocephalus were tested to investigate influence of intracranial pressure pulsation on their flow control characteristics. Five commercial shunt valves were tested in the flow loop that simulates pulsed flow under pressure pulsation. As 20cc/hr of flow rate was adjusted at a constant pressure, application of $40mmH_2O$ of pressure pulse increased the flow rate by $67.9\%.$ As a 90cm length catheter was connected to the valve outlet, increase in the flow rate was substantially reduced to $17.5\%.$ As the flow rate was adjusted to 40cc/hr at a constant pressure, increase in the flow rate was $51.1\%$ with the same pressure pulsation of $40mmH_2O$. The results indicated that pressure-flow control characteristics of shunt valves implanted above human brain ventricle is quite different from those obtained by syringe pump test at constant pressures right after manufacture. The influence of pressure pulsation was observed to be more significant at low flow rate and the flexibility of the outlet silicone catheter was estimated to significantly reduce flow increase due to pressure pulsation.

Clinical Application and its Result of Modified Blalock-Taussig Shunt Using Polytetrafluoroethylene in Congenital Cyanotic Heart Disease (청색심기형환자에서 PTFE 인조혈관을 이용한 쇄골하-폐동맥 단락술의 임상적 적용과 그 결과)

  • 나명훈
    • Journal of Chest Surgery
    • /
    • v.21 no.1
    • /
    • pp.55-61
    • /
    • 1988
  • This report provides follow-up data on 116 patients with congenital cyanotic heart disease, aging 1 month to 13 years [median: 1.8 years], who underwent the modified Blalock-Taussig shunt using polytetrafluoroethylene graft at Seoul National University Hospital between September, 1984 and June, 1987. Among 116 patients complete follow-up studies were done on 95 patients. The mean preoperative arterial oxygen tension was 36 torr. Thirty-Six patients [38%] underwent operation in infancy. Conduit diameters included 4mm [15 cases], 5mm [47 cases], and 6mm [33 cases] sizes. The mean postoperative arterial oxygen tension was 52 torr [P<0.001]. The effectiveness of shunts was evaluated clinically and by shunt murmur, echocardiography and cardiac catheterization with angiography 1 to 31 months after operation. The incidence of shunt occlusion was 9.5% and the mortality was 14.8%. The actuarial patency rate was 83.1 * 6.4% and the actuarial survival rate was 82.5 * 4.5% at 30 months` follow-up for all patients. The effectiveness of the 4mm diameter conduit may be limited. Blalock-Taussig procedure is an effective alternative to the classic B-T shunt in congenital cyanotic heart disease.

  • PDF

A New Volt/Var Control of Substation for Distribution Volt/Var Regulation (배전계통 전압/무효전력조정을 위한 새로운 전압/무효전력제어 방식)

  • Choi, Joon-Ho;Kim, Jae-Chul;Son, Hag-Sig;Im, Tae-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.285-288
    • /
    • 2001
  • In this paper we proposed the on line volt/var control schemes of the load Tap Changer (LTC) transformer and shunt capacitor bank for distribution volt/var regulation. In the existing volt/var control of the distribution substation, the voltage of feeders and var of distribution systems is mainly controlled by the LTC transformer tap position and on/off status of the shunt capacitor. The LTC and shunt capacitor bank has discrete operation characteristics and therefore it is very difficult to control volt/var at the distribution networks within the satisfactory levels. Also there is limitation of the operation times of the LTC and shunt capacitor bank because it is affects on their functional lifetime. The proposed volt/var control algorithm determine an optimal tap position of LTC and on/off status of shunt capacitors at a distribution network with the multiple feeders. The mathematical equations of the proposed method are introduced. Simple case study was performed to verify the effectiveness of the proposed method.

  • PDF

Cooperation Algorithms of LTC and SC for Distribution Volt/Var Regulation (배전계통 전압/무효전력 보상을 위한 LTC변압기와 SC의 협조운전 알고리즘)

  • Choi, Joon-Ho;Kim, Jae-Chul;Nam, Hae-Kon;Moon, Seung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.399-402
    • /
    • 2003
  • In this paper, the on line volt/var control algorithms of the food Load Tap Changer (LTC) transformer and Shunt Capacitor(SC) are proposed for distribution volt/var regulation. In the existing volt/var control of the distribution substation, the voltage of feeders and var of distribution systems is mainly controlled by the LTC transformer tap position and on/off status of the shunt capacitor. The LTC and shunt capacitor bank has discrete operation characteristics and therefore it is very difficult to control volt/var at the distribution networks within the satisfactory levels. Also there is limitation of the operation times of the LTC and shunt capacitor bank because it is affects on their functional lifetime. The proposed volt/var control algorithm determine an optimal tap position of LTC and on/off status of shunt capacitors at a distribution network with the multiple feeders. The mathematical equations of the proposed method are introduced. Simple case study was performed to verify the effectiveness of the proposed method.

  • PDF

Harmonic Current Compensation based on Three-phase Three-level Shunt Active Filter using Fuzzy Logic Current Controller

  • Salim, Chennai;Benchouia, M.T.;Golea, A.
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.595-604
    • /
    • 2011
  • A three-phase three-level shunt active filter controlled by fuzzy logic current controller which can compensate current harmonics generated by nonlinear loads is presented. Three-level inverters and fuzzy controllers have been successfully employed in several power electronic applications these past years. To improve the conventional pwm controller performance, a new control scheme based on fuzzy current controller is adopted for three-level (NPC) shunt active filter. The scheme is designed to improve compensation capability of APF by adjusting the current error using a fuzzy rule. The inverter current reference signals required to compensate harmonic currents use the synchronous reference detection method. This technique is easy to implement and achieves good results. To maintain the dc voltage across capacitor constant and reduce inverter losses, a proportional integral voltage controller is used. The simulation of global system control and power circuits is performed using Matlab-Simulink and SimPowerSystem toolbox. The results obtained in transient and steady states under various operating conditions show the effectiveness of the proposed shunt active filter based on fuzzy current controller compared to the conventional scheme.

Three Phase Current Reconstruction Method of Three Shunt Sensing 3-Phase Inverter by Predictive Current Technique (예측 전류 기법을 적용한 3-션트 전류검출 3상 인버터의 전류 복원 방법)

  • Choo, Kyoung-Min;Hong, Sung-Woo;Jang, Young-Hee;Won, Il-Kuen;Kim, Do-Yun;Wo, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.2
    • /
    • pp.175-180
    • /
    • 2017
  • The measurement of three-phase current is important to control the instantaneous torque of a interior permanent magnet synchronous motor(IPMSM) using a three-phase inverter. Therefore, shunt resistors are used in low-cost motor-driving systems to measure three-phase current instead of additional current sensors that are too expensive for these systems. However, in certain regions of a space vector plane, shunt resistors cannot reconstruct three-phase current in high-speed driving mode. In this paper, predictive current control is used to compensate for the three-phase current in those regions, which results in a reduction of current ripple in a three-shunt sensing inverter(TSSI) and torque ripple in IPMSM.

A Sphaghetti Sign in the Abdominal Radiograph Consistent with Spleno-Systemic Shunts in a Cat

  • Oh, Donghyun;Hwang, Jaewoo;Yoon, Junghee;Choi, Mincheol
    • Journal of Veterinary Clinics
    • /
    • v.37 no.4
    • /
    • pp.227-230
    • /
    • 2020
  • A 8-year-old spayed female Korean short-haired cat was presented with respiratory distress. CBC, serum chemistry analysis, plain radiography, and abdominal ultrasonography were performed. Besides hypertrophic cardiomyopathy (HCM) suspected by the thoracic radiograph, a tubular, tortuous soft tissue structure was detected at the region of the left retroperitoneal cavity on the abdominal radiograph. On the abdominal ultrasonography, a shunt vessel is identified caudo-lateral to the left kidney region. These findings are consistent with spleno-systemic shunts in cats. Furthermore, portal hypertension and diffuse hepatic lesion were also identified. Although the cause of a shunt vessel is not easy to diagnose, it is important to include spleno-systemic shunt into differential diagnosis list, when convoluted, tubular soft tissue opacity is seen on the digital radiography (DR). This report will allow clinicians to raise awareness of complications of portosystemic shunt (PSS) and better treat PSS suspected feline patients when the advanced modalities such as computed tomography and magnetic resonance imaging are not available.

Parameter Optimization for Vibration Control of a Cantilever Beam Using Piezoelectric Shunt Damping System (압전분기회로를 이용한 보 구조물의 진동제어 파라미터 최적화 해석)

  • Lim K.C.;Cho D.S.;Park W.C.;Kee C.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.918-921
    • /
    • 2005
  • According to the mechanical-electrical coupling characteristics and the electrical Impedance property of resistor-inductor-capacitor(RLC) series resonant circuit, the mechanical impedance analysis of a bimorph piezoceramic patch shunted with a series RLC resonant circuit is conducted. The displacement transfer function of a cantilever beam bonded with a piezoelectric shunt damping module is deduced in the case of single mode vibration of the beam. By the use of vibration damping theory of tuned mass damper system, the parameter optimization of piezoelectric shunt damping system is performed. The optimal resonant state of the shunting circuit can be obtained when the resister and conductor are optimally adjusted. Test results show that the vibration control effect as well improved with optimized piezoelectric shunt system.

  • PDF

Coexistence of Radiation-induced Meningiomas and Shunt Related Pneumocephalus in a Patient with Successfully Treated Medulloblastoma

  • Kim, Young-Hoon;Kim, Chae-Yong
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.6
    • /
    • pp.403-407
    • /
    • 2007
  • The authors encountered a case of simultaneous radiation-induced multiple meningiomas and ventriculoperitoneal [VP] shunt-related pneumocephalus. A 35-year-old man, who had undergone surgery for medulloblastoma 21 years previously and subsequently received high dose craniospinal irradiation with adjuvant chemotherapy and later underwent a VP shunt because of hydrocephalus, presented with a severe headache and weakness of both lower extremities. Computed tomography showed an air pocket lesion in the left temporal lobe and a large amount of pneumocephalus with a bony defect of the left tegmen tympani. In addition, a 3 cm sized well enhancing mass was noted in the in the right middle cranial fossa and additional small enhancing nodule in the left frontal pole. He was treated by left temporal craniotomy and repair of the bony and dural defects of the left tegmentum tympanum through extradural and intradural approaches, respectively. Afterwards, he underwent right temporal craniotomy and gross total removal of a rapidly growing right middle fossa mass and a left frontal mass. The histological examination was consistent with atypical meningioma, WHO grade II. In conclusion, physicians have to consider the serious long term complications of high dose radiation therapy and VP shunt placement and need to perform the neuroradiologic follow-up after such treatments for several decades.