• Title/Summary/Keyword: shrinkage stress

Search Result 379, Processing Time 0.03 seconds

Evaluation of Models for Estimating Shrinkage Stress in Patch Repair System

  • Kristiawan, Stefanus A.
    • International Journal of Concrete Structures and Materials
    • /
    • v.6 no.4
    • /
    • pp.221-230
    • /
    • 2012
  • Cracking of repair material due to restraint of shrinkage could hinder the intended extension of serviceability of repaired concrete structure. The availability of model to predict shrinkage stress under restraint condition will be useful to assess whether repair material with particular deformation properties is resistance to cracking or not. The accuracy in the prediction will depend upon reliability of the model, input parameters, testing methods used to characterize the input parameters, etc. This paper reviews a variety of models to predict shrinkage stress in patch repair system. Effect of creep and composite action to release shrinkage stress in the patch repair system are quantified and discussed. Accuracy of the models is examined by comparing predicted and measured shrinkage stress. Simplified model to estimate shrinkage stress is proposed which requires only shrinkage property of repair material as an input parameter.

The Properties of Stress Induced by Autogenous Shrinkage and Dry Shrinkage for High Strength Concrete Using Type I and Type IV Cement (보통 및 저열시멘트를 이용한 고강도 콘크리트의 자기수축응력 및 건조수축응력 특성)

  • Lee Woong-Jong;Um Tae-Sun;Lee Jong-Ryul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.17-20
    • /
    • 2005
  • In this study, the properties of autogenous shrinkage stress and dry shrinkage stress for high strength concrete using Type I and Type IV cement were discussed. According to experimental results, autogenous shrinkage stress of SN30(the high strength concrete using type I cement) shows values higher than SL30(the high strength concrete using type IVcement). It is observed that the total shrinkage stress of SN30 is higher than that of SL30, because the ratio of autogenous shrinkage stress of the total shrinkage stress is relatively large. Therefore, SL30 is more effective to control or minimize the cracking of the high strength concrete, compared with SN30.

  • PDF

Measurements of shrinkage stress and reduction of intercuspal distance in maxillary premolars resulting from polymerization of composites and compomers

  • Lee, Soon-Young;Park, Sung-Ho
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.563-563
    • /
    • 2003
  • The purpose of present study was to evaluate the polymerization shrinkage stress and cuspal deflection in maxillary premolars resulting from polymerization shrinkage of composites and compomers. 1)Measurements of polymerization shrinkage stress. For measurements of polymerization shrinkage stress, Stress measuring machine(R&B, Daejon, Korea) was used. Composites and compomers which were used in this study were as follows:(omitted)

  • PDF

Shrinkage Stress Analysis of Concrete Slab with Shrinkage Strip in Multi-Story Building (수축대를 사용한 고층건물 콘크리트 슬래브의 건조수축응력 해석)

  • 김한수;조석희
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.726-733
    • /
    • 2002
  • Shrinkage strip or separation strip is a temporary joint that is left open for a certain time during construction to allow a significant part of the shrinkage to take place without inducing stress. A shrinkage stress analysis method of shrinkage strip in concrete slab of multi-story building considering the relaxation effect of creep and construction sequence is proposed. The analysis results of 10-story example building show that the effect of shrinkage strip can be analyzed easily by the proposed method. And shrinkage strip installed in a particular floor makes the stress of that floor reduced and the stress of the other floors increased a little. The rate and amount of stress reduced with closing time mainly depends on the development of shrinkage with time of concrete model used. The amount of stress reduced is determined by the amount of shrinkage strain developed before the closing of shrinkage strip.

The Effect of Internal Restraint of Rebar in Shrinkage Stress Analysis of Concrete Slab in Multistory Building (고층건물 콘크리트 슬래브의 건조수축응력 해석에서 철근의 구속효과)

  • Kim Han-Soo;Kim Jae-Keun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.496-499
    • /
    • 2006
  • In this study, a practical method of shrinkage stress analysis on concrete slab in multi-story building is proposed, which considers both internal restraint and external restraint variation resulting from construction sequence. The shrinkage stress due to external restraint is obtained by multiplying relaxation coefficient to elastic shrinkage stress. The additional shrinkage stress due to internal restraint is obtained by residual strain of the elastic analysis. A verification example was analyzed and compared by the proposed method and commercial analysis program that is capable of time-dependent analysis of concrete. The results of 10-story example building show that the internal restraint of reinforcement increases the shrinkage stress considerably at the slabs under loose external restraint.

  • PDF

MEASUREMENTS OF SHRINKAGE STRESS AND REDUCTION OF INTER-CUSPAL DISTANCE IN MAXILLARY PREMOLARS RESULTING FROM POLYMERIZATION OF COMPOSITES AND COMPOMERS (광중합형 구치부 수복재료의 중합 수축력과 교두 변위의 상관관계)

  • Lee, Soon-Young;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.4
    • /
    • pp.346-352
    • /
    • 2004
  • The purpose of present study was to evaluate the polymerization shrinkage stress and cuspal deflection in maxillary premolars resulting from polymerization shrinkage of composites and compomers. Composites and compomers which were used in this study were as follows: Dyract AP, Z100, Surefil. Pyramid, Synergy Compact, Heliomolar, Heliomolar HB, and Compoglass F. For measuring of polymerization shrinkage stress, Stress measuring machine (R&B, Daejon, Korea) was used. One-way ANOVA analysis with Duncan's multiple comparison test were used to determine significant differences between the materials. For measuring of cuspal deflection of tooth, MOD cavities were prepared in 10 extracted maxillary premolars. And reduction of intercuspal distance was measured by strain measuring machine (R&B, Daejon, Korea) One-way ANOVA analysis with Turkey test were used to determine significant differences between the materials. Polymerization shrinkage stress is $\mathbb{\ulcorner}$Heliomolar, Z100, Pyramid < Synergy Compact Compoglass F < Dyract AP < Heliomolr HB, surefil$\mathbb{\lrcorner}$ (P < 0.05). And cuspal delfelction is $\mathbb{\ulcorner}$Z100, Heliomolar, Heliomolar HB, Synergy Compact Surefil. < Compoglass F < Pyramid, Dyract AP$\mathbb{\lrcorner}$ (P < 0.05). Measurements of ploymerization shrinkage stress and those of cuspal deflection of the teeth was different. There is no correlation between polymerization shrinkage stress and cuspal deflection of the teeth(p > 0.05).

The Study on Relationship Between Thermal Stress Properties and Thermal Shrinkage of PET Filament Yarns (PET 필라멘트사의 열응력특성과 열수축율과의 상관성연구)

  • 김영진;김승진;김태훈;김경렬;박인동
    • Textile Coloration and Finishing
    • /
    • v.10 no.2
    • /
    • pp.45-54
    • /
    • 1998
  • This study surveys relation between thermal shrinkage and thermal stress properties after process simulation of heat treatment with various PET filament yarns. For this purpose, 12 kinds of regular yarns and POY, 6 kinds of DTY and 5 kinds of composite yarns were experimented for investigating step thermal shrinkage, total thermal shrinkage and total thermal stress and maximum thermal stress temperature. Thermal stress and shrinkage of the various specimens treated with wet and dry heats were analysed and discussed with the conditions of heat treatment. finally, relationship between thermal stress and shrinkage of the various PET filaments such as regular yarns, POY, DTY and composite yarns were investigated with the PET filament characteristics.

  • PDF

AMOUNT OF POLYMERIZATION SHRINKAGE AND SHRINKAGE STRESS IN COMPOSITES AND COMPOMERS FOR POSTERIOR RESTORATION (광중합형 구치부 수복재료의 중합수축량과 중합수축력)

  • Park, Sung-Ho;Lee, Soon-Young;Cho, Yong-Sik;Kim, Su-Sun;Lee, Chang-Jae;Kim, Young-Joo;Lee, Bong-Hee;Lee, Kouang-Sung;Noh, Byung-Duk
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.4
    • /
    • pp.348-353
    • /
    • 2003
  • The purpose of present study was to evaluate the polymerization shrinkage stress and amount of linear shrinkage of composites and compomers for posterior restoration. For this purpose, linear polymerization shrinkage and polymerization stress were measured. For linear polymerization shrinklage and polymerization stress measurement, custom made Linometer (R&B, Daejon, Korea) and Stress measuring machine was used (R&B, Daejon, Korea). Compositers and compomers were evaluated: Dyract AP (Dentsply Detrey, Gumbh. German) Z100 (3M Dental Products, St. Paul. USA) Surefil (Dentsply Caulk, Milford, USA) Pyramid (Bisco, Schaumburg, USA) Synergy Compact (Coltene, Altstatten, Switzerland), Heliomolar (Vivadent/Ivoclar, Liechtenstein), and Compoglass (Vivadent Ivoclar/Liechtenstein) were used. 15 measurements were made for each material. Linear polymerization shrinkage or polymerization stress for each material was compared with one way ANOVA with Tukey at 95% levels of confidence. For linear shrinkage: Heliomolar, Surefil

A Study on the Applicability of Shrinkage Reduction Effect of Light-weight Aggregate Concrete (경량골재 콘크리트의 수축 저감효과에 관한 적용성 연구)

  • Lim, Sang-Jun;Bang, Chang-Joon;Park, Jong-Hyok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.175-176
    • /
    • 2011
  • Applying previous studies performed in the moisture transportation characteristics and shrinkage of lightweight concrete application of shrinkage reduction is to discuss. Applicability of shrinkage reduction effect of lightweight concrete applies for the analysis of PSC girder bridge beam placed on the construction site. Stress of the concrete bridge deck, rebar quantity is calculated by effective elastic modulus method and crack risk is assessed by moisture transport and differential shrinkage analysis. After approximately 10 days maximum tensile stress occurs 6MPa, similar to the case of normal concrete, a maximum tensile stress occurs 3MPa in lightweight concrete and comparing to normal concrete stress was reduced to approximately 50%. Normal and lightweight concrete crack index, respectively, is reduced 1.6 to 1.2, 1.2 to 0.9 in surface and boundary region. Therefore, reduction in shrinkage of concrete were able to confirm reduction of crack risk.

  • PDF

Tensile Behavior of Reinforced Concrete Member due to Restrained Shrinkage (구속된 건조수축이 철근콘트리트 인장거동에 미치는 영향)

  • 안태송;김진철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.315-320
    • /
    • 1998
  • The experimental set-up and one-dimensional analytical model have been developed to investigate the tensile behavior of reinforced concrete member due to restrained drying shrinkage. The experimental results have been compared with the analytical prediction of the maximum residual stress of steel and concrete due to restrained shrinkage. The tensile residual stress concrete by one-dimensional bilinear model shows 0.19 and 0.63 of tensile strength for 0.83% and 3.29 of steel ratio. The residual tensile stress of concrete increases as the steel ratio increases. The effect of steel fiber has not influenced the residual stress due to restrained shrinkage of concrete.

  • PDF