• Title/Summary/Keyword: shower

Search Result 244, Processing Time 0.025 seconds

User Analysis for Shower Chair Design (고령자용 목욕의자 디자인을 위한 사용자 분석)

  • Jung, Kwang-Tae;Song, Bok-Hee;Shin, Dong-Jin;Chun, Keyoung-Jin;Won, Byeong-Hee;Hong, Jae-Soo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.93-100
    • /
    • 2010
  • In this study, user survey and some experiments were carried out to identify older adults' characteristics and needs for shower chair design. Firstly, the category and design components of shower chair were analyzed through product analysis. Secondly, older adults' needs for shower chair were identified through user interview and observation. Thirdly, experiment to measure older adults' motion, EMG, and body pressure while using shower chair was carried out and then older adults' characteristics for the use of shower chair were identified. Finally, the direction of design for shower chair was proposed to improve older adults' satisfaction.

A Study on the Development of Installation and Management of Safety Shower (Safety shower 설치 및 관리기준 개선에 관한 연구)

  • Lee, Dong Hyeok;Yoo, Byung Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.1-7
    • /
    • 2018
  • Currently chemical plant risk have been issued by occurring frequent accidents. Accidents can be generally composed of fire, explosion, release in chemical plant. In case of fire and explosion, accident victims are occurred immediately after accident but release accident, late emergency response cause damage to worker. Especially, there are many victims by late emergency response against chemical exposure to skin. In case of chemical exposure to skin, irreversible damage like death, blindness, burn can be prevented by washing immediately. Safety shower can provide the cleaning for chemical exposure to eye, skin. Most of chemical plants are built in 1980s so equipment become superannuated. In this reason, safety shower also cannot operate normally in emergency situation. Therefor safety shower should be managed by installation and management guideline. This study perform the establishment guideline for safety shower installation and inspection to increase the reliability.

A Study on the RF Shower System to Extend Interrogating Range on Mobile RFID Reader (모바일 RFID 시스템의 인식거리 확대를 위한 전력 공급용 RF Shower 시스템 개발)

  • Ahn, Si-Young;Kim, Yong-Taek;Bae, Sung-Woo;Nae, Kwan-Kyu;Roh, Hyoung-Hwan;Kim, Gi-Beom;Park, Jun-Seok;Cho, Hong-Goo;Oh, Ha-Ryoung;Seong, Yeong-Rak;Song, Ho-Jun;Jang, Byung-Jun;Lee, Jung-Suk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.1A
    • /
    • pp.91-100
    • /
    • 2007
  • This paper presents the RF Shower System for increased read range on low power mobile RFID System with 20watts of power supply. From the experiment, by controlling the output power of shower system, the tripled read range between reader and Tag is possibly discovered. Thus we can expect on the significantly widen read range of RFID system by appropriate control of Shower Zone, though we only with the reader with its lower output power level of 20dBm.

Development of a Shower Carrier based on the Needs in Long-term Care Institutions

  • Cho, Deok-Yeon;Ko, Cheol-Woong;Chun, Keyoung-Jin;No, Kon-Woo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.379-388
    • /
    • 2012
  • Objective: This study developed a new shower carrier prototype to reduce caregivers' muscle burden and to increase use convenience by reflecting the needs of domestic long-term care institutions. Background: In the long-term care institutions, one of the ADL(Activities of Daily Life) factors is bathing/showering. Recently, bath/shower-assisting equipment is actively being introduced in care institutions to reduce the caregivers' care cost, but most of the domestic equipment was designed to imitate foreign products and rarely reflected the needs of care institutions. Method: Based on Korean elderly people's body information, the bed size(length: 1,900mm, width: 650mm) was set-up, and a variable headrest with a newly designed headform was developed to provide the comfort for the elderly and convenience for caregivers. To reduce caregivers' muscle burden on transferring and showering activities, a 3-step column lifting module equipped with dual actuators(lowest/highest levels from the ground: 600/1,100mm, Stroke: 500mm) was developed, and the wheelbase parameter(length: 1,250mm, width: 580mm) was defined securing the turn-over safety of the shower carrier. The drivability tests were performed for the prototype and foreign product, and the male and female subject's muscle activities were measured through the tests. Results: The structural stability of the shower carrier prototype was secured by finite element analysis, and the muscle activities of the subjects through the drivability tests largely decreased in the prototype, compared to the foreign product. Conclusion: In this study, a new shower carrier prototype was developed to possibly reduce caregivers' muscle burden and to increase use convenience based on the needs of long-term care institutions. It was expected that the drivability performance of the prototype could be relatively superior to that of the foreign product. Application: The results obtained from the study can be applied for the optimal development of a shower carrier including other equipment to effectively care for the elderly.

CFD flow analysis of 150mm shower heads depending on plasma pitch (플라즈마 피치에 따른 150mm 샤워헤드에 대한 CFD 유동해석)

  • Kim, Dong-Hwa;Kim, Ho-Bum;Cho, Chong-Du;Jeong, Dea-Kyo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.585-589
    • /
    • 2008
  • This study is performed to analyze the fluid flow about 150mm shower heads of semiconductor device. Under the air pressure, the ideal gas of moving fluid is injected as 5m/s velocity into inlet of shower heads and the flow distribution in shower heads is measured according to pitch of plasma distribution device. As results, the maximum and minimum value of fluid velocity are investigated with their position. The velocity values at outlet are also studied. From two experiment using the plasma distribution device, the results of CFD are compared with the experimental results. That results shows stable flow of fluid in that case of corrected design from CFD.

  • PDF

A STUDY OF CORRELATION BETWEEN HISTORICAL ASTRONOMICAL RECORDS AND POLITICAL EVENTS (고대 천문기록과 정치적 환경과의 상관관계 연구 - 유성과 유성우 기록을 중심으로 -)

  • Yang, Hong-Jin;Choi, Goeun
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.5
    • /
    • pp.411-418
    • /
    • 2012
  • We study the correlation between distributions of astronomical records and historical events using historical meteor (shower) records. In Korean chronicles, planets and meteor (shower) records are the most abundant astronomical phenomena. And they represent a general tendency of the number distribution of whole astronomical observations. We examine the correlation for the number distribution between meteors (showers) and planets during A.D. 1200-1700 and find that both records have a similar distribution. We classify historical events into three grades according to the social impact, and investigate the correlation between distributions of meteor (shower) records with social events, such as, new king's accession to the throne, foreign invasions, and domestic turmoils. From the statistical analysis, we cannot find any correlation between the meteor (shower) records and the political events. Therefore, we conclude that Korean historical records have not been influenced by the political events. We also examine the correlation between Chinese and Japanese meteor (shower) records and political events for A.D. 1200-1700, respectively, but cannot find any correlations between them.

Fabrication of excimer laser annealed poly-si thin film transistor by using an elevated temperature ion shower doping

  • Park, Seung-Chul;Jeon, Duk-Young
    • Electrical & Electronic Materials
    • /
    • v.11 no.11
    • /
    • pp.22-27
    • /
    • 1998
  • We have investigated the effect of an ion shower doping of the laser annealed poly-Si films at an elevated substrate temperatures. The substrate temperature was varied from room temperature to 300$^{\circ}C$ when the poly-Si film was doped with phosphorus by a non-mass-separated ion shower. Optical, structural, and electrical characterizations have been performed in order to study the effect of the ion showering doping. The sheet resistance of the doped poly-Si films was decreased from7${\times}$106 $\Omega$/$\square$ to 700 $\Omega$/$\square$ when the substrate temperature was increased from room temperature to 300$^{\circ}C$. This low sheet resistance is due to the fact that the doped film doesn't become amorphous but remains in the polycrystalline phase. The mildly elevated substrate temperature appears to reduce ion damages incurred in poly-Si films during ion-shower doping. Using the ion-shower doping at 250$^{\circ}C$, the field effect mobility of 120 $\textrm{cm}^2$/(v$.$s) has been obtained for the n-channel poly-Si TFTs.

  • PDF

Semiquantitative Dynamic Headspace GC-MS Analysis for Organic Compounds Outgassed from FAB Materials of Air Shower (에어샤워부품의 용출 가스 중 유기화합물의 반 정량적 Headspace GC-MS 분석)

  • Park, Hyun-Mee;Baig, Soung-Woo;Kim, Young-Man;Lee, Kang-Bong
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.412-422
    • /
    • 2000
  • The polymeric FAB materials of air shower used in clean room of wafer industry have been outgassed with the dynamic headspace (ca.$100^{\circ}C$) for half an hour, and analyzed using GC-MS. The air in the clean room running air shower was sampled using sorbent tube method, and the organic compounds adsorbed in the sorbent tube were extracted using Soxhlet extraction method, and analyzed using GC-MS. The analytical results from FAB materials of air shower (electric over current relay, acryl plate. polycarbonate window, filter, fan housing, steel galvanized cold plate and canvas buffer) indicated that most of chemicals were originated from polymer fragments of FAB materials. Their analytical results have been compared with those from the air of clean room running air shower. These comparative results could lead to identify whether the sources of trace organic contaminants in clean room air are originated from the polymeric FAB material of air shower.

  • PDF

Low temperature pulsed ion shower doping for poly-Si TFT on plastic

  • Kim, Jong-Man;Hong, Wan-Shick;Kim, Do-Young;Jung, Ji-Sim;Kwon, Jang-Yeon;Noguchi, Takashi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.95-97
    • /
    • 2004
  • We studied a low temperature ion doping process for poly-Si Thin Film Transistor (TFT) on plastic substrates. The ion doping process was performed using an ion shower system, and subsequently, excimer laser annealing (ELA) was done for the activation. We have studied the crystallinity of Si surface at each step using UV-reflectance spectroscopy and the sheet resistance using 4-point probe. We found that the temperature has increased during ion shower doping for a-Si film and the activation has not been fulfilled stably because of the thermal damage against the plastic substrate. By trying newly a pulsed ion shower doping, the ion was efficiently incorporated into the a-Si film on plastic substrate. The sheet resistance decreased with the increase of the pulsed doping time, which was corresponded to the incorporated dose. Also we confirmed a relationship between the crystallinity and the sheet resistance. A sheet resistance of 300 ${\Omega}$/sq for the Si film of 50nm thickness was obtained with a good reproducibility. The ion shower technique is a promising doping technique for ultra low temperature poly-Si TFTs on plastic substrates as well as those on glass substrates.

  • PDF

A Study on the RF Shower System to Extend Interrogating Range for the Low Power RFID Reader System (저출력 RFID 시스템에서 인식거리 확대를 위한 전력 공급용 RF Shower 시스템)

  • Jung, Jin-Wook;Bae, Jae-Hyun;Oh, Ha-Ryoung;Seong, Yeong-Rak;Song, Ho-Jun;Jang, Byeong-Jun;Choi, Kyung;Lee, Jung-Suk;Lee, Hong-Bae;Lee, Hak-Yong;Kim, Jong-Min;Shin, Jae-Cheol;Park, Jun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.12
    • /
    • pp.526-533
    • /
    • 2006
  • In this paper, we presented the synchronization module between RF shower system and RFID Reader to extend interrogating range on Mobile RFID system, Costas Loop and FPLL(Frequency/phase Lock Loop) were used. We achieved compromised range of 3MHz locking frequency, 1ms locking time and figured out remarkable Hopping frequency of the Reader. The prototype of the new designed RFID system has been tested with ISO18000-6 type-B Tag. The read range between designed RFID Reader and Tag has been measured, it increased triple times by adjusting the Shower system output level.