• Title/Summary/Keyword: short implant

Search Result 187, Processing Time 0.028 seconds

A Study on The Dental field of Present Health Insurance for custom-made Prosthetic implant by Dental technicians (건강보험 급여화 관련 치과임플란트보철물 제작실태 연구)

  • Lee, Heekyung;Cho, Mihyang
    • Journal of Technologic Dentistry
    • /
    • v.38 no.1
    • /
    • pp.9-22
    • /
    • 2016
  • Purpose: The Purpose of this study are to describe the Dental field of present health insurance for custom-made prosthetic implant by dental technicians' work. Results: A total of 300 dental technicians working at dental laboratories in Korea were randomly selected and surveyed, 206(68.7%) of them were used for the statistical analysis. Conclusion: Average daily working time was 10 hours 66%. The average cumulative credit of the clinic for dental prosthesis fabrication rates was Less than 10 million won(21.8%), 10~80 million won(11.7%), more than one hundred million won(1.5%). Remake dental prosthesis was one more than the monthly average of 98.5%. Causes of remake dental prosthesis was dentist impression 83% but did not pay 62.5%. Dental technicians Implant production period was 7 days(48.5%), 10 days(35%) was commissioned by dentists production time is 5 days(46.1%), 7 days(36.5%). President of dental laboratories 3.86 points and dental technicians 3.06 points knew differently about starting of implant health insurance coverage(p<.001). They alike were in favor of insurance coverage for the implant. Dental technicians were lower by 2.36 points for work do you know whether your health insurance application of dental prostheses. Dental technicians are 2.16 points on whether confidence in the pores payment of insurance coverage dental prosthesis, dental laboratory president was lower by 1.85 points. They are very low with 1.97 points on whether confidence in the rate payment of health insurance coverage dental prosthesis(p<.01). The implant prosthesis abutment selected, the abutments designed, design of the implant upper prosthetic, the upper prosthetic fitting dental technicians participate of dental laboratory president showed higher score (p <.05). Conclusion: Hours of dental technicians were making this short period of remake dental prosthesis-related dental prosthesis. Dental clinic and a detailed representation of the dental prosthodontic fabrication request is required for communication between the laboratory in order to reduce the remake of a dental prosthesis, dental insurance coverage written dental prosthodontic fabrication request should be legislated. Implant classification standard medical practice 1-3 Step conduct a thorough costing a total of no. 73 of the correct classification standard medical practice in addition to eight times defined by the act of dental technicians should be defined.

A Retrospective Study of Sintered Porous-surfaced Dental Implants in Restoring the Edentulous Posterior Mandible: Up to Eight Years of Functioning (하악 구치부에 식립한 sintered porous surfaced implants의 후향적 다기관 연구)

  • Kim, Woo-Sung;An, Kyung-Mi;Sohn, Dong-Seok;Jung, Heui-Seung;Shin, Im-Hee
    • The Journal of the Korean dental association
    • /
    • v.47 no.12
    • /
    • pp.823-829
    • /
    • 2009
  • Purpose : The aim of this study was to evaluate the survival rate of sintered porous-surfaced implants placed in the edentulous posterior mandibles, in relation to implant length and diameter, crown-to-implant ratio, and types of prostheses, for a maximum of eight years of functioning. Material and Methods : The study group consisted of 43 partially edentulous patients who visited Catholic University Hospital of Daegu and one private dental clinic. A total of 122 sintered porous-surfaced implants n $Endopore^{(R)}$ (Inn ova Life Sciences, Toronto, Ontario, Canada) -- were placed in the edentulous posterior mandibles, Two diameter sizes (4.1 mm and 5.0 mm) and four lengths (5.0 mm, 7.0 mm, 9.0 mm, and 12.0 mm) were used. One hundred and three implants were splinted and 21 implants were nonsplinted. The survival rates of the implants in relation to length, diameter, crown-to-implant ratio, and types of prostheses were investigated. Statistical data were analyzed using SPSS Win.Ver 14.0 software with the Chi-square test. Results : The survival rate of the 4.1mm diameter implants was 100% and 91.2% for the 5.0mm diameter implants. The survival rates of the implants of differing diameters were found to be statistically different (p=0.005). The survival rates of both the 5.0mm and 7.0 mm length implants were 100%. The survival rate of the 9.0mm length implants was 97.9% and for the 12.0mm length implants was 95.1%. There was no statistical difference in survival rates for the differing lengths of implants. Of the 103 prostheses that were splinted, the survival rate was 98.0%. The survival rate of splinted prostheses was higher than that of the non-splinted prostheses, but was found to be not statistically different. There were no failed cases when the crown-to-implant ratio was under 1.0. When the crown-to-implant ratio was between 1.0 and 1.5, the failure rate of the implants was 6.7%. No failure was recorded with the ratio range of 1.5 to 2.0. Relative to the crown-to-implant ratio of 1.0, the failure rates were statistically different (p=0.048). Discussion and Conclusion : The cumulative survival rate of the porous-surfaced implants placed in the edentulous posterior mandibles was 97.5%. Short porous-surfaced implants showed satisfactory results after a maximum of nine years of functioning in the edentulous posterior mandibles.

  • PDF

A Retrospective study of the Cumulative Survival Rate and change of peri-implant marginal bone around implants associated with maxillary sinus augmentation (상악동 골 이식술을 동반하여 식립된 임플란트의 변연골변화와 생존률에 관한 후향적 연구)

  • Ryu, Hwa-Suk;Kim, Sun-Jong;Park, Eun-Jin;Kim, Myung-Rae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.240-246
    • /
    • 2009
  • Statement of problem: Insertion of endosseous implants in the atrophic maxilla is often complicated because of lack of supporting bone. Augmentation of the floor of the maxillary sinus with autogenous bone & bone substitute graft has been proven to be a reliable treatment modality, at least in the short term. The aim of this study is to evaluate the factors of implant survival rate associated with maxillary sinus lift with grafts. Material and methods: The sinus floor was augmented with bone grafts derived from modified Caldwell-luctechnique(71 subject, 93 sinus, 180 implants), the autogenous bone or autogenous+Bio-oss. Before implant installation the width and height of the alveolar crest were increased in the first stage procedure in 10 patients while in the other 61 patients augmentation and implant installation could be performed simultaneously width and height of the alveolar crest > 4 mm) or delayed installation. Results: In all case bone volume was sufficients for implant insertion. 14 of 180 inserted implants were lost during follow up and the healing period Patient received implant supported overdenture(5 patients) or fixed bridge(62 patients). Conclusion: Within the limit of the result of this study, we conclude that bone grafting of the floor of the maxillary sinus floor with bone for the insertion of implants might be a reliable treatment modality and the autogenous bone graft and delayed installation method might be the factors for good results.

Comparative Study Of Osseointergration On Different Immediate Implants In Extraction Sockets Of Beagle Dogs (성견에 발치 후 즉시 임플란트 식립시 RBM 처리된 임플란트의 골융합에 관한 연구)

  • Sun, Ki-Jong;Park, Jae-Young;Jung, Eun-Gyeong;Shin, Mee-Ran;Kim, Yun-Sang;Pi, Sung-Hee;Shin, Hyung-shik;You, Hyung-Keun
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.209-221
    • /
    • 2007
  • Recently, immediately after losing teeth. implant placement has been greatly attempted. Implant can help restoration of tooth functions within short time. This study was an attempt to examine the extent of osseointergation when the implants will be placed immediately after teeth extraction using domestic implant systems. Implants were inserted in beagle dogs and evaluated the clinical, radiological, histological and histomorphometric assay at 6 weeks and 12 weeks. For experimental materals, $STAGE-1^{(R)}$($4.1{\times}8mm$, Lifecore, USA), $SS-III^{(R)}$($4.0{\times}8mm$, OSSTEM, Korea) and $IFI^{(R)}$($4.0{\times}8mm$, Dio, Korea) implants treated with RBM were placed. All the placed site showed normal results without fail and inflammation clinically and radiologically. As a result of measurement by periotest, it showed $-2\;{\sim}\;-5$ and stable status comprehensively. There was no statistically significant difference among implants(p<0.05). Bone tissue adjacent to implant showed increased marrow tissue at 6 weeks. Nevertheless, osteogenic structure was not observed remarkably. In a 12 weeks opinion, bone tissue composed of osseointegration along implant interface showed significantly decreased marrow tissue containing central vessels unlike a 6 weeks opinion and matured compact bone whose osteogenic structure is well formed. BIC were 42.4%, 32.0% and 34.9%, respectively in 6 weeks and there was no statistically significant difference among group(p<0.05). In 12 weeks, BIC were 58.8%, 61.9% and 57.5%. respectively and there was no statistically significant difference among groups(p<0.05). It is considered that all 3 implant systems are suitable for immediate implant placement.

Implementation of curved type a metallic plate system at the Bone contact (골 접촉 곡선형 금속 고정 시스템 구현)

  • Kim, Jeong-Lae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.5
    • /
    • pp.285-292
    • /
    • 2007
  • This study was developed the metallic plate for fixation in the femur fracture for the orthopedic region and rigid fixation with plates has a firm place in fracture treatment. Most plates can be used for rigid as well as biological and dynamical fracture fixation. The device's designation and sizing has a specific with bending structural stiffness and strength, known meaning that is reliable regardless of the plate by the short type and long type. Short plate have a wrapping of femur and long plate have to preserve a pole of femur. The bending strength of the curved metallic long plate has to evaluate a 11,000N and The bending strength of the curved metallic short plate has to evaluate a 6,525N. The tensile stress through to press a plate is $1573N/m^2\;and\;1539N/m^2$. The device can be used to support Revision case of Hip Implant and to use a case of Hip screw compression of Hip Neck Fracture.

  • PDF

Effects of Doping Concentration of Polycrystalline Silicon Gate Layer on Reliability Characteristics in MOSFET's (MOSFET에서 다결정 실리콘 게이트 막의 도핑 농도가 신뢰성에 미치는 영향)

  • Park, Keun-Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.2
    • /
    • pp.74-79
    • /
    • 2018
  • In this report, the results of a systematic study on the effects of polycrystalline silicon gate depletion on the reliability characteristics of metal-oxide semiconductor field-effect transistor (MOSFET) devices were discussed. The devices were fabricated using standard complimentary metal-oxide semiconductor (CMOS) processes, wherein phosphorus ion implantation with implant doses varying from $10^{13}$ to $5{\times}10^{15}cm^{-2}$ was performed to dope the polycrystalline silicon gate layer. For implant doses of $10^{14}/cm^2$ or less, the threshold voltage was increased with the formation of a depletion layer in the polycrystalline silicon gate layer. The gate-depletion effect was more pronounced for shorter channel lengths, like the narrow-width effect, which indicated that the gate-depletion effect could be used to solve the short-channel effect. In addition, the hot-carrier effects were significantly reduced for implant doses of $10^{14}/cm^2$ or less, which was attributed to the decreased gate current under the gate-depletion effects.

Short-term evaluation of dental implants in a diabetic population: an in vivo study

  • Inbarajan, Athiban;Veeravalli, Padmanabhan Thallam;Vaidyanathan, Anand Kumar;Grover, Manita
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.134-138
    • /
    • 2012
  • PURPOSE. The study was conducted to evaluate the efficacy of implant supported tooth replacement in diabetic patients. MATERIALS AND METHODS. The study involved placement of implants (UNITI implants, Equinox Medical Technologies, Zeist, Holland, diameter of 3.7 mm and length 13 mm) in five diabetic patients (three females and two males) of age ranging from 35-65 years with acceptable metabolic control of plasma glucose. All patients included in the study were indicated for single tooth maxillary central incisor replacement, with the adjacent teeth intact. The survival of the restored implants was assessed for a period of three months by measurement of crestal bone heights, bleeding on probing and micro flora predominance. Paired t-test was done to find out the difference in the microbial colonization, bleeding on probing and crestal bone loss. P values of less than 0.05 were taken to indicate statistical significance. RESULTS. Results indicated that there was a significant reduction in bleeding on probing and colonization at the end of three months and the bone loss was not statistically significant. CONCLUSION. The study explores the hypothesis that patients with diabetes are appropriate candidates for implants and justifies the continued evaluation of the impact of diabetes on implant success and complications.

Esthetic removable partial denture with implants and resin clasp: Case report (임플란트와 레진 클래스프를 이용한 심미 가철성 국소의치 증례)

  • Kim, Su-Min;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.58-65
    • /
    • 2015
  • For the rehabilitation of fully edentulous patients, implant-supported removable partial dentures can be considered as one of the treatment options with complete dentures or implant-supported overdentures. If removable partial dentures are used in combination with a small number of implants placed in strategically important positions, it can offer additional stability, retention and support through implants and reduce a burden of surgical procedures compared with fixed implant-supported prostheses with extensive implant placement. Moreover, the economical benefit can be expected as well. The purpose of this case report is to present a treatment in which an implant-supported removable partial denture was fabricated considering residual alveolar bone status and demands after teeth loss in a patient who had been using a distal extension removable partial denture for a long period of time. In anterior area, fixed prostheses were fabricated with implant placement and in posterior area, short implants provide only support for the removable partial denture. In addition, denture base and clasp were made of thermoplastic acrylic resin. Finally, functionally and aesthetically satisfying treatment results can be achieved.

SINUS AUGMENTATION WITH ${\beta}$-TCP (${\beta}$-TCP를 이용한 상악동 점막거상술)

  • Hwang, Kyung-Gyun;Song, Seung-Il;Kim, Sang-Woo;Lee, Sung-Hoon;Kim, Young-Muen;Shim, Kwang-Sup
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.5
    • /
    • pp.428-433
    • /
    • 2004
  • Sinus floor augmentation has been proven an effective treatment procedure to increase bone volume in the posterior edentulous maxilla. Autogenous bone considered to be the best material for reconstructive bone surgery and has been successfully used as a graft material to augment posterior maxilla. However, the collection of autogenous bone required extra risks for morbidity and complaints. So, various bone graft materials included ${\beta}$-tricalcium phosphate(${\beta}$-TCP) has been introduced for replacing the autogenous bone. The objective of this clinical study was to determine the predictability of endosseous implant placed in a maxillary sinus with ${\beta}$-TCP grafting. We performed sinus elevation with ${\beta}$-TCP to install the implant in the 10 maxillary cases. The prosthetic procedure was performed 6-9 months after. The implant-prosthetics was checked about 1 year. We checked the implant and measured the maximum bite force to evaluate the function of the implant. There was not observed the specific problem and complication in dental implant and maxillary sinus in the grafted materials. The maximum bite force was 558N in case of natural tooth, 365N in implant without grafting, 318N in implant with ${\beta}$-TCP grafting. There was no significant difference between with and without sinus grafting on maximum bite force(p>0.05). As though the long term check-up is needed, the grafting of ${\beta}$-TCP as a osteoconductive materials can expand the volume and induce dense new bone formation in maxillary sinus. So, this short-term results support that ${\beta}$-TCP can be a suitable material for sinus augmentation.

Digital intraoral impression for immediate provisional restoration of maxillary single implant: A case report (구강 내 디지털 인상채득을 통한 상악 전치부 임플란트 즉시 임시 보철 수복 증례)

  • Chang, Yun-Jeong;Kim, Hong-Jun;Song, Mi-Kyoung;Moon, Ji-Eun;Lee, Hal-La;Park, Chan-Ik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.234-243
    • /
    • 2015
  • Developing of digital technique, it is possible to fabricate implant prostheses for edentulous area using intraoral 3-dimentional information throughout implant diagnosis and treatment process. It is being changed that from the method using CAD/CAM, producing prostheses by model scanning after conventional impression and model processing, to the method of fabricating implant provisional restorations and customized abutments by digital impression after connecting digital impression copings (scanbody) and implant fixtures without models. But, this digital method has not been actively used for implant prostheses not yet. Specially, it is short of intraoral digital impression cases for immediate provisional restorations of the maxillary anterior implants. The gingival contour impression of maxillary anterior area is very important for esthetic restorations. Accordingly, in this case report, the using a digital impression coping (scanbody) and digital impression by CEREC Omnicam (Sirona, Bensheim, Germany) or Trios (3shape, Copenhagen, Denmark) were introduced for immediate provisional restorations in 3 cases needed a single implant restoration in maxillary anterior area. The clinical results were satisfactory on the convenience and accuracy of digital impression technique and the good esthetics of final restorations.