• Title/Summary/Keyword: short implant

Search Result 188, Processing Time 0.027 seconds

The Electrical Characteristics of MOSFET having Deuterium implanted Gate Oxide (중수소 이온 주입된 게이트 산화막을 갖는 MOSFET의 전기적 특성)

  • Lee, Jae-Sung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.4
    • /
    • pp.13-19
    • /
    • 2010
  • MOSFET with deuterium-incorporated gate oxide shows enhanced reliability compared to conventional MOSFET. We present an alternative process whereby deuterium is delivered to the location where the gate oxide reside by an implantation process. Deuterium ions were implanted using two different energies to account for the topography of the overlaying layers and placing the D peak at the top of gate oxide. A short anneal at forming gas was performed to remove the D-implantation damage. We have observed that deuterium ion implantation into the gate oxide region can successfully remove the interface states and the bulk defects. But the energy and the dose of the deuterium implant need to be optimized to maintain the Si substrates dopant activation, while generating deuterium bonds inside gate oxide. CV and IV characteristics studies also determined that the deuterium implant dose not degrade the transistor performance.

Comparing the Results of Using Bioabsorbable Magnesium Screw with Those Using a Titanium Screw for the Treatment of Mild to Moderate Hallux Valgus: Short-term Follow-Up (경도-중등도 무지외반증 환자의 생체 흡수성 마그네슘 나사못과 티타늄 나사못을 사용한 수술의 단기 결과 비교)

  • Hong, Sung yup;Kim, Gab-Lae;Han, Woosol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.24 no.3
    • /
    • pp.107-112
    • /
    • 2020
  • Purpose: Hallux valgus (HV) is a common foot deformity that causes pain in the first metatarsophalangeal joint. Distal metatarsal osteotomies are commonly performed as a treatment. This retrospective study compared the clinical and radiological results of bioabsorbable magnesium (Mg) versus titanium (Ti) screw fixation for modified distal chevron osteotomy in HV. Materials and Methods: Forty-nine patients, who underwent modified distal chevron osteotomy for HV in 2018 and 2019, were reviewed retrospectively. Bioabsorbable Mg screw fixation was applied in 20 patients (22 feet), and a traditional Ti compression screw was applied in 29 patients (40 feet). The patients were followed up for at least six months. The clinical results were evaluated using the American Orthopaedic Foot and Ankle Society hallux metatarsophalangeal-interphalangeal (AOFAS-MTP-IP) scale and a visual analogue scale (VAS). The hallux valgus angle (HVA), intermetatarsal angle (IMA), and distal metatarsal articular angle (DMAA) were measured before, after surgery, and at the six months follow-up. Results: The AOFAS-MTP-IP scale and VAS points were improved in both groups, with no significant difference between them. At the six-month follow-up, HVA, IMA, and DMAA were similar. Bone union was confirmed in both groups, and there were no significant major complications in both groups. Four people in the Ti screw group underwent implant removal surgery. Conclusion: Bioabsorbable Mg screws showed comparable clinical, radiologic results to Ti standard screws six months after distal modified chevron osteotomy. These screws are an alternative fixation material that can be used safely and avoid the need for implant removal operations.

Breast Reconstruction after Modified Radical Mastectomy with Becker Permanent Tissue Expander (변형 근치 유방절제술 후 Becker 확장형 보형물을 이용한 유방 재건술)

  • Hong, Yong Taek;Yoon, Eul Sik;Choi, Kyu Jin;Dhong, Eun Sang;Son, Gil Soo
    • Archives of Plastic Surgery
    • /
    • v.34 no.2
    • /
    • pp.222-228
    • /
    • 2007
  • Purpose: Report of the good results of breast reconstruction using Becker permanent tissue expander that showed a short operation time and a quick post-operation recovery time, little side effects and usually superb aesthetic results without the need for additional incisions or donor site morbidity. The authors, after carrying out breast reconstruction operations using Becker permanent tissue expander on patients with appropriate indications, attempted to analyze several factors such as complication rates and patient satisfaction measurements. Methods: 11 cases of breast reconstruction using Becker expander implants were carried out on a total of 10 patients between March 2000 and February 2003. The patients were followed up at outpatient visit for an average of 6 months. Results: The most common post-operation complication was pain resulting from saline injection into the expanders, complained by 5 patients(50%). rib fractures, skin necrosis, implant removal due to infection, and breast cancer recurrence each occurred in 1 patient (9.9%). There was no occurrence of skin contracture complications which occurs frequently in case of silicone implant insertion. Patient complacency was surveyed by patient interviews made right after the operations and during outpatient follow-up periods: 5(50%) patients out of 10 showed excellent, 3(30%) good, and 2(20%) showed fair, leaving no patients who were disappointed with operation results. On routine follow-up, 80% of patients expressed satisfaction with the cosmetic outcome of their post-mastectomy beast reconstruction. Conclusion: Breast reconstruction using the Becker expander is a reliable alternative to other reconstructive methods but good patient selection is essential for satisfactory results.

Fibrin affects short-term in vitro human mesenchymal stromal cell responses to magneto-active fibre networks

  • Spear, Rose L.;Symeonidou, Antonia;Skepper, Jeremy N.;Brooks, Roger A.;Markaki, Athina E.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.2 no.3
    • /
    • pp.143-157
    • /
    • 2015
  • Successful integration of cementless femoral stems using porous surfaces relies on effective periimplant bone healing to secure the bone-implant interface. The initial stages of the healing process involve protein adsorption, fibrin clot formation and cell osteoconduction onto the implant surface. Modelling this process in vitro, the current work considered the effect of fibrin deposition on the responses of human mesenchymal stromal cells cultured on ferritic fibre networks intended for magneto-mechanical actuation of in-growing bone tissue. The underlying hypothesis for the study was that fibrin deposition would support early stromal cell attachment and physiological functions within the optimal regions for strain transmission to the cells in the fibre networks. Highly porous fibre networks composed of 444 ferritic stainless steel were selected due to their ability to support human osteoblasts and mesenchymal stromal cells without inducing untoward inflammatory responses in vitro. Cell attachment, proliferation, metabolic activity, differentiation and penetration into the ferritic fibre networks were examined for one week. For all fibrin-containing samples, cells were observed on and between the metal fibres, supported by the deposited fibrin, while cells on fibrin-free fibre networks (control surface) attached only onto fibre surfaces and junctions. Initial cell attachment, measured by analysis of deoxyribonucleic acid, increased significantly with increasing fibrinogen concentration within the physiological range. Despite higher cell numbers on fibrin-containing samples, similar metabolic activities to control surfaces were observed, which significantly increased for all samples over the duration of the study. It is concluded that fibrin deposition can support the early attachment of viable mesenchymal stromal cells within the inter-fibre spaces of fibre networks intended for magneto-mechanical strain transduction to in-growing cells.

Quality of Life in Older Adults with Cochlear Implantation: Can It Be Equal to That of Healthy Older Adults?

  • Tokat, Taskin;Muderris, Togay;Bozkurt, Ergul Basaran;Ergun, Ugurtan;Aysel, Abdulhalim;Catli, Tolgahan
    • Korean Journal of Audiology
    • /
    • v.25 no.3
    • /
    • pp.138-145
    • /
    • 2021
  • Background and Objectives: This study aimed to evaluate the audiologic results after cochlear implantation (CI) in older patients and the degree of improvement in their quality of life (QoL). Subjects and Methods: Patients over 65 years old who underwent CI at implant center in Bozyaka Training and Research Hospital were included in this study (n=54; 34 males and 20 females). The control group was patient over 65 years old with normal hearing (n=54; 34 males and 20 females). We administered three questionnaires [World Health Organization Quality of Life-BREF (WHOQOL-BREF), World Health Organization Quality of Life-OLD (WHOQOL-OLD)], and Geriatric Depression Scale (GDS) to evaluate the QoL, CIrelated effects on activities of daily life, and social activities in all the subjects. Moreover, correlations between speech recognition and the QoL scores were evaluated. The duration of implant use and comorbidities were also examined as potential factors affecting QoL. Results: The patients had remarkable improvements (the mean score of postoperative speech perception 75.7%) in speech perception after CI. The scores for the WHOQOL-OLD and WHOQOL-BREF questionnaire responses were similar in both the study and control groups, except those for a two subdomains (social relations and social participation). The patients with longer-term CI had higher scores than those with short-term CI use. In general, the changes in GDS scores were not significant (p<0.05). Conclusions: The treatment of hearing loss with CI conferred significant improvement in patient's QoL (p<0.01). The evaluation of QoL can provide multidimensional insights into a geriatric patient's progress and, therefore, should be considered by audiologists.

Quality of Life in Older Adults with Cochlear Implantation: Can It Be Equal to That of Healthy Older Adults?

  • Tokat, Taskin;Muderris, Togay;Bozkurt, Ergul Basaran;Ergun, Ugurtan;Aysel, Abdulhalim;Catli, Tolgahan
    • Journal of Audiology & Otology
    • /
    • v.25 no.3
    • /
    • pp.138-145
    • /
    • 2021
  • Background and Objectives: This study aimed to evaluate the audiologic results after cochlear implantation (CI) in older patients and the degree of improvement in their quality of life (QoL). Subjects and Methods: Patients over 65 years old who underwent CI at implant center in Bozyaka Training and Research Hospital were included in this study (n=54; 34 males and 20 females). The control group was patient over 65 years old with normal hearing (n=54; 34 males and 20 females). We administered three questionnaires [World Health Organization Quality of Life-BREF (WHOQOL-BREF), World Health Organization Quality of Life-OLD (WHOQOL-OLD)], and Geriatric Depression Scale (GDS) to evaluate the QoL, CIrelated effects on activities of daily life, and social activities in all the subjects. Moreover, correlations between speech recognition and the QoL scores were evaluated. The duration of implant use and comorbidities were also examined as potential factors affecting QoL. Results: The patients had remarkable improvements (the mean score of postoperative speech perception 75.7%) in speech perception after CI. The scores for the WHOQOL-OLD and WHOQOL-BREF questionnaire responses were similar in both the study and control groups, except those for a two subdomains (social relations and social participation). The patients with longer-term CI had higher scores than those with short-term CI use. In general, the changes in GDS scores were not significant (p<0.05). Conclusions: The treatment of hearing loss with CI conferred significant improvement in patient's QoL (p<0.01). The evaluation of QoL can provide multidimensional insights into a geriatric patient's progress and, therefore, should be considered by audiologists.

Success rate and marginal bone loss of Osstem USII plus implants; Short term clinical study (Osstem USII plus 임플란트의 단기간 성공률 및 변연골 흡수량 평가)

  • Kim, Sun-Keun;Kim, Jee-Hwan;Lee, Keun-Woo;Cho, Kyoo-Sung;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.206-213
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the clinical value of Osstem$^{(R)}$ USII plus system implants. Clinical and radiographic data were analyzed for 88 implants placed and functionally loaded for a 12 month period at the Yonsei University Dental Hospital. Materials and Method: Based on the patient's medical records, clinical factors and their effects on implant marginal bone resorption, distribution and survival rate were analyzed. The marginal bone loss was evaluated at implant placement and during a 6 to 12 months functional loading period. The independent sample t-test was used to evaluate the interrelationship between the factors (${\alpha}$=0.05), and one way repeated measures ANOVA was used to compare the amount of marginal bone resorption. Results: The cumulative survival rate for 88 implants was 100%. The marginal bone resorption from implant placement to prosthetic delivery was 0.24 mm and the average marginal bone resorption from prosthetic delivery to 12 months of functional loading was 0.19 mm. The total average bone resorption from implant placement to 12 months of functional loading was 0.43 mm. There were no statistically differences in the amount of marginal bone resorption when implants were placed in the maxilla or the mandible (P>.05), however, implants placed in the posterior areas showed significantly more marginal bone loss than those placed in the anterior areas (P<.05). Conclusion: Based on these results, the short term clinical success rate of RBM surface treated external connection domestic implants showed satisfactory results and the marginal bone loss was in accord with the success criteria of dental implants.

Retention of CAD/CAM Metal Copings Cemented on Short Titanium Abutments with Different Cements (짧은 티타늄 지대주에 합착된 CAD/CAM 금속 코핑의 시멘트 종류에 따른 유지력 비교)

  • Kim, Hyo-Jung;Song, Eun-Young;Yoon, Ji-Young;Lee, Si-Ho;Lee, Yong-Keun;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.119-126
    • /
    • 2012
  • State of problem: Cement-retained implant-supported prostheses are routinely used in dentistry. The use of high strength cements has become more popular with the increasing confidence in the stability of the implant-abutment screw connection and the high survival rates of osseointegrated implants. No clinical data on retention of metal copings using CAD/CAM. To evaluate retention of metal copings using CAD/CAM system bonded to short titanium abutment with four different cements and compare retentive strength of metal copings with sandblasting or without sandblasting before cementation. Forty titanium abutment blocks were fabricated and divided into 4 groups of 10 samples each. Forty metal copings with occlusal hole to allow for retention testing were fabricated using CAD/CAM technology. The four cements were Fujicem(Fuji, Japan), Maxcem Elite(Kerr, USA), Panavia F2.0(Kurarary, Japan) and Superbond C&B(Sunmedical, Japan). The copings were cemented on the titanium abutment according to manufacture's recommendation. All samples were stored for 24h at 37oC in 100% humidity and tested for retention using universal testing machine(Instron) at a crosshead speed of 1.0mm/min. Force at retentive failure was recorded in Newton. The mode of failure was also recorded. Means and standard deviations of loads at failure were analyzed using ANOVA and Paired t-test. Statistical significance was set at P<0.05. Panavia F2.0 provided significantly higher retentive strength than Fujicem, Maxcem Elite(P<0.05). Sandblasting significantly increased bond strength(P<0.05). The mode of failure was cement remaining principally on metal copings. Within the limitation of this study, Panavia F2.0 showed significantly stronger retentive strength than Fujicem, Maxcem Elite(p<0.05). The Ranking order of the cements to retain the copings was Panavia F2.0, Fujicem = Maxcem Elite. Sandblasting significantly increased bond strength(P<0.05). The retentive strength of metal copings on implant abutment were influenced by surface roughness and type of cements.

Radiographic evaluation of alveolar bone profile of maxillary anterior teeth in Korean young adult (한국인 성인의 상악 전치부 치조골 형태에 관한 방사선학적 연구)

  • Seo, Hyo-Seok;Chung, Chin-Hyung;Lim, Sung-Bin;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.461-471
    • /
    • 2006
  • In order to achieve a satisfactory esthetic result of periodontal surgery or implant in maxillary anterior area, periodontists must be aware of normal alveolar bone anatomy. The purpose of this study was to evaluate the relationship of alveolar bone morphology to tooth shape and form. 78(mean age : 25 yrs) periodontally healthy volunteers participated in this study. Two maxillary central incisor and one lateral incisor were selected to study. With minimal local anesthesia, gutta-percha cone inserted to labial gingival sulcus of selected teeth just after bone sounding with periodontal probe. Metal ball (4mm diameter) attached to palatal fossa of central incisor. Then, periapical radiograph was taken according to long cone paralleling technique. After film scan, labial alveolar bone profile reproduced along interproximal bone and apical ends of gutta-percha cones on computer screen. By utilizing computer program, the distance from height of interproximal bone to the labial bone crest in central incisor-central incisor and central incisor-lateral incisor area was measured and converted to real distance by using vertical length of metal ball on film. After measuring crown length & width of central incisor, the 10 individuals ranked lowest GW/L ratio (crown width/length ratio) and the 10 ranked highest were selected as having a long-narrow(group N), or a short-wide(group W) form of the central incisors. Means of the distance from height of interproximal bone to the labial bone crest of group N, W were calculated and compared by means of independent t-test. The results were as follows: 1. Mean distance from the height of the interproximal bone to the labial bone crest was $3.5{\pm}0.7mm$ between two central incisor, and $2.8{\pm}0.6mm$ between central and lateral incisor. 2. Mean GW/L ratio of group N was 0.57, and group W was 0.8. Mean distance from the height of the interproximal bone to the labial bone crest of group N was higher than group W in both measured area(measurements of group N, W were $3.9{\pm0.2mm$ and $3.5{\pm}0.2mm$ between two central incisor, $3.0{\pm}0.2mm$ and $2.8{\pm}0.2mm$ between central and lateral incisor), but there were no statistically significant differences when the groups were compared. Within the limits of the present study, there was a tendency that subjects with long-narrow teeth have more scalloped alveolar bone profile than subjects with short-wide teeth in upper anterior area, but no statistically significant differences were found.

Aesthetic Rhinoplasty for the Improvement of the Lateral Facial Profile; Image-up Rhinoplasty (얼굴의 측면 윤곽선 개선을 위한 미용 코성형술)

  • Min Sung
    • Archives of Plastic Surgery
    • /
    • v.32 no.2
    • /
    • pp.205-213
    • /
    • 2005
  • There are several characteristics of the nose of orientals. The dorsum of nose is flat and low, the skin is thick with severe tension, the nasal tip is bulbous, the nostril is wide, and the projection of the nose is limited due to a poorly developed alar cartilage with a short columella. In order to improve these untoward characteristics of the nose of Orientals aesthetically, plain augmentation of the dorsum and tip-plasty with conventional methods has been performed by many plastic surgeons. However these conventional rhinoplasty is not enough to obtain satisfactory results when transforming into a more beautiful and aesthetically charming appearance. In order to produce the optimal nasal shape and profile, it is extremely important to consider the aesthetic surgical factors, which are; the position of the nasion, the optimal nasolabial angle(95-100 degree in Orientals), the natural exposure of infra-tip lobule with and columella, the position of the tip defining point in harmony with the dorsal profile and the smooth and natural silhouette of the lateral nasal profile as it descends into the inferior portion of the nose. From April, 2003 to August, 2004, a total of 52 patients underwent open rhinoplasty, adhering to the strict aesthetic principles considered and described priorly. Surgical approach was done through a transcolumella incision and an alar rim incision. The nasal dorsum was augmented with a silicone implant and the shape of the columella and the nasolabial angle were finessed with a silicone strut implant which was placed in between the medial crurae in a manner of a non-visible graft. The nasal tip was corrected by alar cartilage suture technique and onlay graft of shield shaped Alloderm and Gore-Tex. Author obtained the optimal nasal shape and profile aesthetically, and the results, considered satisfactory in all patients without any complications, are as follows; 1. the average increase in nasal length was 2.5 mm, 2. the average decrease in nasal width was 2.1 mm, 3. the average increase in nasal tip projection was 3.2 mm, 4. the changes of nasolabial angles were from 85.5 degree to 94.7 degree, 5. the changes of the angle between the long axis of the external naris was from 101.3 degree to 89.5 degree. In conclusion, this surgical procedure is an effective, reliable and a valuable method in improving the nasal shape, tip projection, nasolabial angle and especially, the lateral facial profile of Orientals aesthetically.