• Title/Summary/Keyword: shin-huh

Search Result 524, Processing Time 0.03 seconds

The Effect of Metallic Oxides on the Formation Rates and Rigidities of the Elastic Sodium Alginate-$CaSO_4{\cdot}1/2H_2O$ Gel. (Sodium Alginate-$CaSO_4{\cdot}1/2H_2O$ 彈性體의 生成速度 및 彈性에 미치는 金屬酸化物의 影響)

  • Shin, Hong-Dae;Huh, Yeonn;Kim, Uun-Sik
    • Journal of the Korean Chemical Society
    • /
    • v.9 no.1
    • /
    • pp.16-22
    • /
    • 1965
  • The time-lag-effect of alkali salts on the gelation of sodium alginate-$CaSO_4{\cdot}$1/2 $H_2O$ is compared with Miyake's data, and then the formation rate of the elastics measured by the continuous method (an improved Schwedoff's method) and the change of rigidity with metallic oxides are studied as follows: (1) The gelation processes of sodium alginate and $CaSO_4{\cdot}$1/2 $H_2O$-aqueous sol are studied by measuring, continuously the increases of tensions ofsamples. (2) The time-lag-effect of $Na_3PO_4$ on the formation rate of the elastic gel is larger than that of $Na_2CO_3$, but the difference between the effects of the two alkali salts on the rate is found not so greater than predicted in Miyake's data. (3) Any regularities of the effect on the rate by metallic oxides are not observed. The increasing effects of the rates of $SiO_2$ and MgO are relatively large, and that of ZnO is relatively small. However, $Al_2O_3$, $Sb_2O_3$ and $TiO_2$show some decreasing effects. As a result it is noted that the regularities do not depend on the effect of oxide species and their amounts. (4) It is not found proportionality between the rigidity and the gelation rate. However, the increasing effect of the rigidity with the addition of metallic oxides can be observed. The rigidity increasing rate of MgO is the largest of them.

  • PDF

Analysis of Dose Distribution on Critical Organs for Radiosurgery with CyberKnife Real-Time Tumor Tracking System (사이버나이프 실시간 종양추적 시스템을 이용한 방사선수술 시 주요 장기의 선량분포 분석)

  • Huh, Hyun-Do;Choi, Sang-Hyoun;Kim, Woo-Chul;Kim, Hun-Jeong;Kim, Seong-Hoon;Ji, Young-Hoon;Kim, Kum-Bae;Lee, Sang-Hoon;Choi, Jin-Ho;Lee, Re-Na;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.14-20
    • /
    • 2009
  • We measured the dose distribution for spinal cord and tumor using Gafchromic film, applying 3D and 4D-Treatment Planning for lung tumor within the phantom. A measured dose distribution was compared with a calculated dose distribution generated from 3D radiation treatment planning and 4D radiation treatment planning system. The agreement of the dose distribution in tumor for 3D and 4D treatment planning was 90.6%, 97.64% using gamma index computed for a distance to agreement of 1 mm and a dose difference of 3%. However, a gamma agreement index of 3% dose difference tolerence of and 2 mm distance to agreement, the accordance of the dose distribution around cord for 3D and 4D radiation treatment planning was 57.13%, 90.4%. There are significant differences between a calculated dose and a measured dose for 3D radiation treatment planning, no significant differences for 4D treatment planning. The results provide the effectiveness of the 4D treatment planning as compared to 3D. We suggest that the 4-dimensional treatment planning should be considered in the case where such equipments as Cyberknife with the real time tracking system are used to treat the tumors in the moving organ.

  • PDF

Chamber to Chamber Variations of a Cylindrical Ionization Chamber for the Calibration of an $^{192}Ir$ Brachytherapy Source Based on an Absorbed Dose to Water Standards (물흡수선량 표준에 기반한 $^{192}Ir$ 근접치료 선원 교정 시 원통형 이온함의 이온함 간 변화)

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Kim, Chan-Hyeong;Min, Chul-Hee;Shin, Dong-Oh;Choi, Jin-Ho
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.7-13
    • /
    • 2009
  • This work is for the preliminary study for the calibration of an $^{192}Ir$ brachytherapy source based on an absorbed dose to water standards. In order to calibrate brachytherapy sources based on absorbed dose to water standards using a clyndirical ionization chamber, the beam quality correction factor $k_{Q,Q_0}$ is needed. In this study $k_{Q,Q_0}s$ were determined by both Monte carlo simulation and semiexperimental methods because of the realistic difficulties to use primary standards to measure an absolute dose at a specified distance. The 5 different serial numbers of the PTW30013 chamber type were selected for this study. While chamber to chamber variations ran up to maximum 4.0% with the generic $k^{gen}_{Q,Q_0}$, the chamber to chamber variations were within a maximum deviation of 0.5% with the individual $k^{ind}_{Q,Q_0}$. The results show why and how important ionization chambers must be calibrated individually for the calibration of $^{192}Ir$ brachytherapy sources based on absorbed dose to water standards. We hope that in the near future users will be able to calibrate the brachytherapy sources in terms of an absorbed dose to water, the quantity of interest in the treatment, instead of an air kerma strength just as the calibration in the high energy photon and electron beam.

  • PDF

A 5-year retrospective clinical study of the Dentium implants

  • Lee, Jeong-Yol;Park, Hyo-Jin;Kim, Jong-Eun;Choi, Yong-Geun;Kim, Young-Soo;Huh, Jung-Bo;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.4
    • /
    • pp.229-235
    • /
    • 2011
  • PURPOSE. The aim of this retrospective study was to evaluate cumulative survival rate (CSR) of Implantium implants followed for 5 years and association between risk factors and the CSR. MATERIALS AND METHODS. A total of two hundred forty-nine Implantium Implants System (Dentium, Seoul, Korea) placed in ninety-five patients from 2004 to 2009 were investigated with several identified risk factors (sex, systemic disease, smoking, alchohol, reason of tooth loss, length, arch (maxilla or mandible), replace tooth type (incisor, canine, premolar or molar) Kennedy classification, prosthodontic type, prosthodontic design, opposite dentition, abutment type, occlusal material, occlusal unit, splint to tooth, cantilever, other surgery). Clinical examination (mobility, percussion, screw loosening, discomfort, etc.) and radiographic examination data were collected from patient records including all problems during follow-up period according to protocols described earlier. Life table analysis was undertaken to examine the CSR. Cox regression method was conducted to assess the association between potential risk factors and overall CSR. RESULTS. Five of 249 implants were failed. Four of these were lost before loading. The 5-year implant cumulative survival rate was 97.37%. Cox regression analysis demonstrated a significant predictive association between overall CSR and systemic disease, smoking, reason of tooth loss, arch, Kennedy classification and prosthodontic design (P<.05). The screw related complication was rare. Two abutment screw fractures were found. Another complications of prosthetic components were porcelain fracture, resin facing fracture and denture fracture (n=19). CONCLUSION. The 5-year CSR of Implantium implants was 97.37 %. Implant survival may be dependent upon systemic disease, smoking reason of tooth loss, arch, Kennedy classification and prosthodontic design (P<.05). The presence of systemic diseases and combination of other surgical procedures may be associated with increased implant failure.

Influence of the implant-abutment connection design and diameter on the screw joint stability

  • Shin, Hyon-Mo;Huh, Jung-Bo;Yun, Mi-Jeong;Jeon, Young-Chan;Chang, Brian Myung;Jeong, Chang-Mo
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.126-132
    • /
    • 2014
  • PURPOSE. This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS. Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (${\alpha}$=0.05). RESULTS. The postload removal torque value was high in the following order with regard to magnitude: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). CONCLUSION. The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate.

Effect of denture cleansers on Candida albicans biofilm formation over resilient liners

  • Huh, Jung-Bo;Lim, Younghun;Youn, Hye-In;Chang, Brian Myung;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.109-114
    • /
    • 2014
  • PURPOSE. The purpose of this study was to analyze the effect of denture cleansers on Candida albicans biofilm formation over resilient liners and to evaluate compatibility between resilient liners and denture cleansers. MATERIALS AND METHODS. Acrylic resin (Lucitone 199$^{(R)}$) and 3 resilient liners (COE-SOFT$^{TM}$, GC RELINE$^{TM}$ and SOFRELINER TOUGH TOUGH$^{(R)}$) were incubated in denture cleansers (Polident$^{(R)}$ and Cleadent$^{(R)}$) for 8 hours a day and in unstimulated saliva for 16 hours a day (n=25/gp) for 60 days. Two-way and three-way repeated measures ANOVA were performed to compare the surface roughness (Ra), pH and C. albicans binding level by radioisotope (${\alpha}$=0.05). The statistical significance of the relation between Ra and adhesion was evaluated by correlation analysis. RESULTS. The degree of Ra was significantly decreased in the following order: COE-SOFT$^{TM}$, acrylic resin, GC RELINE$^{TM}$ and SOFRELINER TOUGH$^{(R)}$. The immersion in denture cleansers significantly increased Ra of resilient liners, except for SOFRELINER TOUGH$^{(R)}$ in Cleadent$^{(R)}$. No significant differences in pH curves were observed among groups immersed in distilled water and denture cleansers. The binding levels of C. albicans were significantly decreased in the following order: COE-SOFT$^{TM}$, GC RELINE$^{TM}$, SOFRELINER TOUGH$^{(R)}$, and acrylic resin. The immersion in Cleadent$^{(R)}$ seemed to decrease C. albicans binding level on GC RELINE$^{TM}$ and SOFRELINER TOUGH$^{(R)}$. CONCLUSION. Based on the C. albicans binding levels results, it is not recommended to immerse COE-SOFT$^{TM}$ in denture cleansers, and GC RELINE$^{TM}$ and SOFRELINER TOUGH$^{(R)}$ should be immersed in Cleadent$^{(R)}$.

Verification of X-sight Lung Tracking System in the CyberKnife (사이버나이프에서 폐종양 추적 시스템의 정확도 분석)

  • Huh, Hyun-Do;Choi, Sang-Hyoun;Kim, Woo-Chul;Kim, Hun-Jeong;Kim, Seong-Hoon;Cho, Sam-Ju;Min, Chul-Ki;Cho, Kwang-Hwan;Lee, Sang-Hoon;Choi, Jin-Ho;Lim, Sang-Wook;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.174-179
    • /
    • 2009
  • To track moving tumor in real time, CyberKnife system imports a technique of the synchrony respiratory tracking system. The fiducial marker which are detectable in X-ray images were demand in CyberKnife Robotic radiosurgery system. It issued as reference markers to locate and track tumor location during patient alignment and treatment delivery. Fiducial marker implantation is an invasive surgical operation that carries a relatively high risk of pneumothorax. Most recently, it was developed a direct lung tumor registration method that does not require the use of fiducials. The purpose of this study is to measure the accuracy of target applying X-sight lung tracking using the Gafchromic film in dynamic moving thorax phantom. The X-sight Lung Tracking quality assurance motion phantom simulates simple respiratory motion of a lung tumor and provides Gafchromic dosimetry film-based test capability at locations inside the phantom corresponding to a typical lung tumor. The total average error for the X-sight Lung Tracking System with a moving target was $0.85{\pm}0.22$ mm. The results were considered reliable and applicable for lung tumor treatment in CyberKnife radiosurgery system. Clinically, breathing patterns of patients may vary during radiation therapy. Therefore, additional studies with a set real patient data are necessary to evaluate the target accuracy for the X-sight Lung Tracking system.

  • PDF

Pygidiopsis summa (Digenea: Heterophyidae): Status of Metacercarial Infection in Mullets from Coastal Areas in the Republic of Korea

  • Sohn, Woon-Mok;Na, Byoung-Kuk;Cho, Shin-Hyeong;Lee, Won-Ja;Park, Mi-Yeoun;Lee, Soon-Won;Choi, Seung-Bong;Huh, Beom-Nyung;Seok, Won-Seok
    • Parasites, Hosts and Diseases
    • /
    • v.54 no.4
    • /
    • pp.497-502
    • /
    • 2016
  • To know the infection status of zoonotic trematode metacercariae in brackish water fish, we surveyed mullets collected from 18 coastal areas in the Republic of Korea. The metacercariae of Pygidiopsis summa were detected in 236 (68.2%) out of 346 mullets examined. They were found in mullets from 15 areas except for those from Boseong-gun (Jeollanam-do), Pohang-si, and Uljin-gun (Gyeongsangbuk-do). Especially in mullets from Taean-gun (Chungcheongnam-do) and Geoje-si (Gyeongsangnam-do), their prevalences were 100% and 95.5%, and the average metacercarial density was more than 1,000 per fish. They were also detected in mullets from 3 coastal lakes, Gyeongpoho, Songjiho, and Hwajinpoho, in Gangwon-do, and their average densities were 419, 147, and 672 per infected fish, respectively. The metacercariae of 5 other heterophyid species, including Heterophyes nocens, Heterophyopsis continua, Metagonimus sp., Stictodora fuscata, and Stictodora lari, were found in the mullets examined. The metacercariae of H. nocens were detected in 66.7, 100, 28.6, 81.6, 3.9, 61.5, and 27.3% of mullets from Muan-gun, Shinan-gun, Haenam-gun, Gangjin-gun, and Boseong-gun (Jeollanam-do), Hadong-gun, and Geoje-si (Gyeongsangnam-do), and their metacercarial intensities were 64, 84, 119, 99, 1, 24, and 24 per fish infected, respectively. From the above results, it has been confirmed that P. summa metacercariae are heavily infected in mullets from coastal areas of Korea. It is suggested that residents who frequently consume raw mullet dish can be easily infected with heterophyid flukes.

Source Location on Full-Scale Wind Turbine Blade Using Acoustic Emission Energy Based Signal Mapping Method (음향방출 에너지 기반 신호 맵핑 기법을 이용한 실물 풍력 블레이드 손상 검출)

  • Han, Byeong-Hee;Yoon, Dong-Jin;Huh, Yong-Hak;Lee, Young-Shin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.443-451
    • /
    • 2013
  • Acoustic emission(AE) has emerged as a powerful nondestructive tool to detect any further growth or expansion of preexisting defects or to characterize failure mechanisms. Recently, this kind of technique, that is an in-situ monitoring of inside damages of materials or structures, becomes increasingly popular for monitoring the integrity of large structures like a huge wind turbine blade. In this study, the activities of AE signals generated from external artificial sources was evaluated and located by new developed signal mapping source location method and this test is conducted by 750 kW full-scale blade. And a new source location method was applied to assess the damage in the wind turbine blade during step-by-step static load test. In this static loading test, we have used a full scale blade of 100 kW in capacity. The results show that the acoustic emission activities give a good agreement with the stress distribution and damage location in the blade. Finally, the applicability of the new source location method was confirmed by comparison of the result of source location and experimental damage location.

Comparative Feeding Values of Soybean Hulls and Wheat Bran for Growing and Finishing Swine

  • Chee, Kew M.;Chun, Kwang S.;Huh, Bong D.;Choi, Jin H.;Chung, Mahn K.;Lee, Hyung S.;Shin, In S.;Whang, Kwang Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.6
    • /
    • pp.861-867
    • /
    • 2005
  • Feeding values of soybean hulls (SH) were compared to those of wheat bran (WB) for swine diets by chemical compositions, a digestion trial, a preference test by self-selection, and two feeding trials. The SH and the WB appeared to have, on airdry basis, 11.1 vs. 15.4% CP, 32.5 vs. 8.7% crude fiber (CF), 36.8 vs. 10.7% ADF, 0.6 vs. 0.1% Ca, and 492 vs. 92 ppm Fe, respectively. Lysine and total sulfur-containing amino acids in the SH were 0.66 vs. 0.37%, respectively. Apparent digestibility values of the SH were 71% for dry matter, 50% for CP, and 74% for CF. Apparent digestible energy and MEn values of the SH were 2,420 and 2,370 kcal kg$^-1$, respectively, which were comparable to those of the WB, 2,420 and 2,275 kcal kg$^-1$ (NRC, 1998), respectively. The first feeding trial was conducted with 72 crossbred growing pigs with an average weight of 29.6 kg. The pigs when fed the diets containing 0, 6 and 10% SH by replacing the WB on a weight basis for 42 days did not show significant differences in body weight gain and feed/gain ratio among the treatments. The same trends were observed in the second trial with 60 crossbred finishing pigs with an average weight of 64.5 kg when fed the diets containing 12% SH or WB for 41 days. Back-fat thickness and adjusted loin eye muscle area of the finisher pigs were also not significantly different between the two groups. When allowed to self-select from two different feed troughs containing 10% SH or WB for two weeks, two groups of 80 pigs with 10 pigs per pen consumed the two diets exactly in equal proportion. In conclusion, the soybean hulls can be included up to 10 and 12% for growing or finishing pig diets, respectively, replacing the wheat bran on a weight basis without any adverse effects on palatability of diets and animal performances.