• 제목/요약/키워드: shielding thickness

검색결과 262건 처리시간 0.025초

시판 전자기파 차단 직물의 차폐효과 및 물성 (EMI shielding Effectiveness and the Physical Properties of Commercial EMI shielding Fabrics)

  • 한은경;오경화;김은애
    • 한국의류학회지
    • /
    • 제23권5호
    • /
    • pp.694-702
    • /
    • 1999
  • By using commercial available electromagnetic interference (EMI) shielding fabrics, EMI shielding effectiveness(SE) and the physical properties were investigated. Thirteen specimens were chosen six fabrics were non-electrolytic plated with Cu, six plated with Cu+Ni and one plated with Ni, SE was measured by RF Impedance Analyzer HP4291A(Hewlett Co, Ltd)at the frequency of 100MHz-1.8GHz. The results showed that the commercial EMI shielding fabrics provided SE values over 30dB at the frequency of 100MHz-1.8GHz. Fabrics plated with Cu showed more effective shielding than those plated with Ni. The thickness of coating and fabric count were also influential factors on SE. Tensile properties were acceptable for lining fabrics but water vapor transport properties indicated that the better treatment condition were suggested to improve comfort properties.

  • PDF

Survey of Radiation Shielding Design Goals and Workload Based on Radiation Safety Report: Tomotherapy Vault

  • Cho, Kwang Hwan;Jung, Jae Hong;Min, Chul Kee;Bae, Sun Hyun;Moon, Seong Kwon;Kim, Eun Seog;Cho, Sam Ju;Lee, Rena
    • 한국의학물리학회지:의학물리
    • /
    • 제29권1호
    • /
    • pp.42-46
    • /
    • 2018
  • The purpose of this study was to perform a survey of the radiation shielding design goals (P) and workload (W) based on the radiation safety reports concerned with structural shielding design for the IMRT treatment technique in Tomotherapy vaults. The values of the P and W factors as well as of a verified concrete thickness of the ceiling, bottom, sidewalls (sidewall-1 and sidewall-2), and door have been obtained from radiation safety reports for a total of 16 out of 20 vaults. The recommended and most widely used report for P values was the NCRP No. 151 report, which stated that the P factor in controlled and uncontrolled areas was 0.1 and 0.02 mSv/week, respectively. The range of the W factor was 600~14,720 Gy/week. The absorbed dose delivered per patient was 2~3 Gy. The maximum number of patients treated per day was 10~70. The quality assurance (QA) dose was 100~1,000 Gy/week. Fifteen values of the IMRT factor (F) were mostly used but a maximum of 20 values was also used. The concrete thickness for primary structures including the ceiling, bottom, sidewalls, and door was sufficient for radiation shielding. The P and W factors affect the calculation of the structural shielding design, and several parameters, such as the absorbed dose, patients, QA dose, days and F factor can be varied according to the type of shielding structure. To ensure the safety of the radiation shielding, it is necessary to use the NCRP No. 151 report for the standard recommendation values.

Experimental study of the radiation shielding characteristics of new PbO-Na2O-B2O3-BaO glasses

  • M.I. Sayyed;U. Rilwan;K.A. Mahmoud;Mohamed Elsafi
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2437-2443
    • /
    • 2024
  • This work synthesized four glass samples with a fixed ratio of PbO to Na2O and a variable ratio of BaO to B2O3. The linear attenuation coefficient (LAC) (μ, cm-1) and additional attenuator parameters were determined experimentally using a semiconductor detector and different gamma sources. The comparison was carried out between the experimental and the XCOM calculated results, with good agreement emerging between the two results. The impacts of the BaO substituting for the B2O3 on fabricated PNBB glasses' radiation shielding properties were discussed. By increasing the BaO substitution concentration between 10 and 25 mol.%, the LAC μ values (cm-1) increased by 76.60 %, 13.81 %, 12.56 %, and 12.52 % for the respective γ-ray energies of 0.059, 0.662, 1.173, and 1.332 MeV. The μ value reduction with raised gamma energy values increased the values of the calculated half-value thickness (Δ0.5) as a result of the μ and Δ0.5 values' reverse proportionality. Other shielding parameters such as the lead equivalent thickness (Δeq) and radiation protection efficiency were also determined for the present PNBB glass samples.

3D 프린터를 이용한 바륨혼합형 차폐체에 대한 연구 (A Study on Barium Mixed Radiation Shield using 3D Printer)

  • 강헌효;김동현
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.627-634
    • /
    • 2020
  • 본 연구는 기존의 납을 대신해 친환경 물질인 황산바륨과 3D 프린터 소재인 PLA 필라멘트를 혼합하여 형태학적 구현을 위한 차폐체를 개발하고자 하였다. 환경 물질인 황산바륨 분말 가루와 3D프린터 소재인 PLA 필라멘트를 사용하였으며, 황산바륨 분말 가루와 PLA를 혼합하기 위하여 압출기로 융합 후 3D 프린터로 차폐체를 제작하였다. 황산바륨 파우더 분말 가루와 PLA 필라멘트 혼합비율을 확인하기 위해 혼합입도를 분석하였으며, 혼합된 차폐체의 차폐능을 확인하기 위해 황산바륨 함유량에 따른 두께별 흡수선량을 구하여 선량을 평가한 후 차폐능을 분석했다.황산바륨 분말 입자와 PLA 필라멘트 혼합 입도 평가 시 외관상과 주사전자현미경 관찰사진에서 함유량이 30%일 때 가장 적정비율로 혼합된 것을 확인하였다. 황산바륨 함유량에 따른 두께별 흡수선량 결과에서 함유량이 0%일 때와 각 % 별 함유량을 비교했을 때 두께 0.5 cm에서 흡수선량의 차이가 가장 크게 나타났으며, 바륨함유량이 30%일 때 두께 3 cm에서 가장 낮은 선량값을 나타냈다. 또한 바륨함유량이 30%를 기점으로 함유량이 증가할수록 흡수 선량값은 다시 높아지는 결과가 나타났다. 기존의 납 대신 친환경 물질인 황산바륨을 필라멘트 소재인 PLA와 혼합하여 형태학적인 차폐체를 만들 수 있었다. 혼합물에 대한 바륨의 혼합비율은 30%가 가장 적절하며, 본 연구를 토대로 진단 방사선 분야 내 3D 프린터를 이용한 형태학적 차폐체 구현을 위한 기초 자료로 사용될 것으로 기대한다.

고 에너지 전자선 치료를 위한 3D 프린터 물질의 차폐 성능평가 (Evaluation of Shielding Performance of 3D Printer Materials for High-energy Electron Radiation Therapy)

  • 오창우;배상일;문영민;양현경
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.687-695
    • /
    • 2022
  • 고 에너지 전자선 치료 시 차폐체로 사용되는 납을 대체할 수 있는 3D 프린터 소재를 찾기 위해 MCNP6 프로그램을 사용하였다. 고 에너지 전자선을 방출하는 선형가속기의 PDD(Percent Depth Dose), Flatness, Symmetry를 측정하고, MCNP6로 선형가속기를 모의 모사 후 비교하여 실측과 모의 모사와의 선원항이 일치함을 확인하였다. 납 차폐체를 모의 모사하여, 흡수선량의 95 % 이상을 차폐할 수 있는 납 차폐체의 적정 두께를 선정하였다. 3 mm 두께의 납 차폐체에 대한 흡수선량 데이터를 기준으로 하여 ABS + W(10%), ABS + Bi(10%), PLA + Fe(10%) 소재들의 1, 5, 10, 15 mm 두께 별로 모의 모사로 분석하여 차폐성능을 분석하였다. 3D 프린터로 각각의 시제품을 제작하여 모의 실험과 같은 조건으로 측정하여 분석한 결과 ABS+W(10%) 소재가 최소 10 mm 이상의 두께로 형성되었을 때, 3 mm 두께의 납을 대체할 수 있는 차폐성능을 가지는 것을 확인하였다. 주사전자현미경(SEM)과 EDS 스펙트럼을 이용하여 ABS + W(10%) 소재의 원소조성 및 표면형상을 분석하였다. 이러한 결과를 통해, 상용화 된 납 차폐체를 ABS + W(10%) 소재로 대체하면 납과 같은 차폐효과를 낼 뿐만 아니라 3D 프린터를 이용하여 환자 맞춤형으로 제작할 수 있어 고 에너지 전자선 치료에 매우 유용할 수 있음을 확인하였다.

니켈나노파우더 함침기법을 이용한 탄소복합소재의 전자파차폐 효과에 관한 연구 (Carbon Composite Material Using Nickel Nano-Powder Impregnation Research on Electromagnetic Shielding Effect)

  • 서광수;곽이구
    • 한국기계가공학회지
    • /
    • 제19권12호
    • /
    • pp.49-55
    • /
    • 2020
  • In order to improve the electromagnetic shielding rate of Carbon Fiber (CF), it was produced using the nickel nano-powder impregnating method. Using two types of nickel powder having thicknesses of 50 ㎛ and 100 ㎛, and a thermoplastic elastomer resin, a compound containing 10-20% nickel content was mixed and then manufactured through an extruder. The CF coated with the compound was woven and manufactured using a 1-ply specimen. The final nickel content of the specimen was verified using TGA and the distribution of nickel powder on the CF surface was verified using SEM. The metal shows a high shielding rate in the low-frequency band, but the shielding rate decreases at higher-frequency bands. The CF improves at the higher frequency band, and metals reflect electromagnetic waves while carbon absorbs electromagnetic waves. The study of shielding materials, which are stronger and lighter than metal, by using CF lighter than metal and enabling the shielding rate from low-frequency band to high-frequency band, confirmed that the larger the area coated with nickel nano-powder, the better the electromagnetic shielding performance. In particular, CF coated with a thickness of 100 ㎛ has a shielding rate similar to that of copper and can also be used for EV/HEV automotive cables and other applications in the future.

강내치료실 차폐에 대한 고찰 (A Study on Structural Shielding Design of Afterloading Therapy Room)

  • 윤석록;김명호;신동오
    • 대한방사선치료학회지
    • /
    • 제2권1호
    • /
    • pp.31-40
    • /
    • 1987
  • In the case of designing a high dose rate remote controlled afterloading treatment room with existing hospital facilities. We must construct the effective protective barriers so as to reduce the primary and scattered radiation up to the maximum permissible dose level. It is difficult to reinforce the barrier thickness of the shielding requirements because of the limited space and the problem of the existing building structure at the surrounding area. Therefore we can reduce the intensity of primary radiation to the required degree at the location of interest with installing the appropriate I shaped Pb barriers between the radiation source and the shielding wall of the concrete. As a result, it was possible to reduce the intensity of the primary radiation below the M.P.D level by using additional Pb barriers instead of increasing thickness of concrete wall.

  • PDF

고에너지 전자선 치료 시 텅스텐 함유 3D 프린팅 물질의 차폐 성능 평가 (Evaluation of Shielding Performance of Tungsten Containing 3D Printing Materials for High-energy Electron Radiation Therapy)

  • 조용인;김정훈;배상일
    • 한국방사선학회논문지
    • /
    • 제17권5호
    • /
    • pp.641-649
    • /
    • 2023
  • 본 연구에서는 3D 프린팅 기술을 활용하여 제작한 차폐체의 성능을 비교 분석하여, 고에너지 전자선 치료 시 차폐체로서의 적용 가능성에 대해 알아보고자 한다. 고에너지 전자선에 대한 3D 프린팅 재료의 차폐성능 평가를 위해 실측과 몬테카를로 기반의 모의실험을 수행하였다. 첫 번째, 모의실험에 대한 신뢰성 확보를 위해 IAEA의 TRS-398 권고를 참조하여 선원항 평가를 수행하였다. 두 번째, PLA+W (93%) 재료에 대한 차폐 성능 분석을 위해 3D 프린터를 이용하여 시편을 제작하였고, 전자선 에너지에 따른 두께별 차폐율을 평가하였다. 세 번째, PLA+W (93%)와 기존 차폐체 간 차폐 성능 비교 분석을 통해 전자선 치료 시 필요한 차폐 두께를 산정하였다. 연구 결과, 첫 번째, 실측과 모의실험을 통한 선원항 평가 결과, 1% 이내의 오차로 TRS-398 권고를 만족하여 모의실험에 대한 신뢰성을 확보하였다. 두 번째, PLA+W (93%)에 대한 차폐 성능 분석 결과, 6 MeV 전자선은 3.12 mm에서 95% 이상의 차폐율을 나타냈고, 15 MeV 전자선은 10 mm 두께에서 90% 이상의 차폐율을 나타내었다. 세 번째, 모의실험을 통해 PLA+W (93%) 재료와 기존 차폐체 간 비교 분석을 통해 동일 두께 내에서 텅스텐, 납, 구리, PLA+W (93%), 알루미늄 순서로 차폐율이 높은 결과를 나타내었으며, 6 MeV 전자선은 5 mm 이상, 15 MeV 전자선은 10 mm 이상 두께에서 거의 유사한 차폐율을 나타내었다. 향후 본 연구를 통해 고에너지 전자선 치료 시 PLA+W (93%) 재료를 이용한 환자의 맞춤형 차폐체 제작을 위한 기초자료로서 활용될 수 있을 것으로 판단된다.

아리랑 2호의 방사능 환경 및 영향에 관한 분석(I)- TOTAL IONIZING DOSE 영향 중심으로 - (THE ANALYSIS ON SPACE RADIATION ENVIRONMENT AND EFFECT OF THE KOMPSAT-2 SPACECRAFT(I): TOTAL IONIZING DOSE EFFECT)

  • 백명진;김학정
    • Journal of Astronomy and Space Sciences
    • /
    • 제18권2호
    • /
    • pp.153-162
    • /
    • 2001
  • 본 논문에서는 아리랑 2호가 운용될 궤도의 우주방사능 환경 및 total ionizing dose(TID) 영향에 대하여 분석하였다. 포획된 양자의 경우 SAA(South Atlantic Anomaly) 지역에 집중되어 있음을 알 수 있었으며, TID에 영향을 미치는 우주 방사능은 포획된 양자 및 전자와 태양양자임을 알 수 있었다. 저 에너지 입자는 알루미늄 차단 구조물을 이용하여 방사능 영향을 효과적으로 차단할 수 있음을 알 수 있었으나, 고 에너지 입자의 경우 구조물의 두께를 증가하여도 방사능 영향을 효과적으로 차단할 수 없음을 알 수 있었다. 아리랑 2호의 임무수명기간 동안 전자부품에 계속적으로 피폭되는 전체 방사량을 알루미늄 차단두께의 함수로 나타내었으며, 이 값들은 아리랑 2호의 전자부품의 선택기준 및 위성체 또는 구성품의 구조물 두께를 설정할 수 있는 기준으로 제시하였다.

  • PDF

탄소나노튜브(CNT)를 혼입한 초고성능 콘크리트(UHPC)의 고고도 전자기파(HEMP) 방호성능 평가 (Evaluation on High Altitude Electromagnetic Pulse(HEMP) Protection Performance of Carbon Nanotube(CNT) Embedded Ultra-High Performance Concrete(UHPC))

  • 정명준;홍성걸
    • 한국군사과학기술학회지
    • /
    • 제22권2호
    • /
    • pp.151-161
    • /
    • 2019
  • In this study, to evaluate the High Altitude Electromagnetic Pulse(HEMP) protection performance of UHPC/CNT composites by the content of Carbon nanotubes(CNTs), Electromagnetic Shielding Effectiveness(SE) test was performed based on MIL-STD-188-125-1. And the results were verified by applying the Antenna theory. In the case of UHPC with a thickness of 200 mm mixed with 1 % CNT of cement weight, the SE was 28.98 dB at 10 kHz and 45.94 dB at 1 GHz. Then the Scabbing limit thickness for bullet proof was computed based on the result of compressive strength test which was 170 MPa, and it was examined whether it satisfied the HEMP protection criteria. As a result, the required HEMP shielding criteria were satisfied in all frequency ranges as well as the scabbing limit thickness was reduced by up to 43 % compared with that of ordinary concrete.