• Title/Summary/Keyword: shape reconstruction

Search Result 464, Processing Time 0.031 seconds

Edge Grouping and Contour Detection by Delaunary Triangulation (Delaunary 삼각화에 의한 그룹화 및 외형 탐지)

  • Lee, Sang-Hyun;Jung, Byeong-Soo;Jeong, Je-Pyong;Kim, Jung-Rok;Moon, Kyung-li
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.1
    • /
    • pp.135-142
    • /
    • 2013
  • Contour detection is important for many computer vision applications, such as shape discrimination and object recognition. In many cases, local luminance changes turn out to be stronger in textured areas than on object contours. Therefore, local edge features, which only look at a small neighborhood of each pixel, cannot be reliable indicators of the presence of a contour, and some global analysis is needed. The novelty of this operator is that dilation is limited to Deluanary triangular. An efficient implementation is presented. The grouping algorithm is then embedded in a multi-threshold contour detector. At each threshold level, small groups of edges are removed, and contours are completed by means of a generalized reconstruction from markers. Both qualitative and quantitative comparison with existing approaches prove the superiority of the proposed contour detector in terms of larger amount of suppressed texture and more effective detection of low-contrast contour.

Immersive Visualization of Casting Solidification by Mapping Geometric Model to Reconstructed Model of Numerical Simulation Result (주물 응고 수치해석 복원모델의 설계모델 매핑을 통한 몰입형 가시화)

  • Park, Ji-Young;Suh, Ji-Hyun;Kim, Sung-Hee;Rhee, Seon-Min;Kim, Myoung-Hee
    • The KIPS Transactions:PartA
    • /
    • v.15A no.3
    • /
    • pp.141-149
    • /
    • 2008
  • In this research we present a novel method which combines and visualizes the design model and the FDM-based simulation result of solidification. Moreover we employ VR displays and visualize stereoscopic images to provide an effective analysis environment. First we reconstruct the solidification simulation result to a rectangular mesh model using a conventional simulation software. Then each point color of the reconstructed model represents a temperature value of its position. Next we map the two models by finding the nearest point of the reconstructed model for each point of the design model and then assign the point color of the design model as that of the reconstructed model. Before this mapping we apply mesh subdivision because the design model is composed of minimum number of points and that makes the point distribution of the design model not uniform compared with the reconstructed model. In this process the original shape is preserved in the manner that points are added to the mesh edge which length is longer than a predefined threshold value. The implemented system visualizes the solidification simulation data on the design model, which allows the user to understand the object geometry precisely. The immersive and realistic working environment constructed with use of VR display can support the user to discover the defect occurrence faster and more effectively.

Segmentation of tooth using Adaptive Optimal Thresholding and B-spline Fitting in CT image slices (적응 최적 임계화와 B-spline 적합을 사용한 CT영상열내 치아 분할)

  • Heo, Hoon;Chae, Ok-Sam
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.4
    • /
    • pp.51-61
    • /
    • 2004
  • In the dental field, the 3D tooth model in which each tooth can be manipulated individually is an essential component for the simulation of orthodontic surgery and treatment. To reconstruct such a tooth model from CT slices, we need to define the accurate boundary of each tooth from CT slices. However, the global threshold method, which is commonly used in most existing 3D reconstruction systems, is not effective for the tooth segmentation in the CT image. In tooth CT slices, some teeth touch with other teeth and some are located inside of alveolar bone whose intensity is similar to that of teeth. In this paper, we propose an image segmentation algorithm based on B-spline curve fitting to produce smooth tooth regions from such CT slices. The proposed algorithm prevents the malfitting problem of the B-spline algorithm by providing accurate initial tooth boundary for the fitting process. This paper proposes an optimal threshold scheme using the intensity and shape information passed by previous slice for the initial boundary generation and an efficient B-spline fitting method based on genetic algorithm. The test result shows that the proposed method detects contour of the individual tooth successfully and can produce a smooth and accurate 3D tooth model for the simulation of orthodontic surgery and treatment.

A Study in Bridging Sciatic Nerve Defects with Combined Skeletal Muscle and Vein Conduit in Rats (백서의 좌골신경에서 정맥 및 골격근을 이용한 결손신경 봉합술에 대한 연구)

  • Lee, Jun-Mo
    • Archives of Reconstructive Microsurgery
    • /
    • v.6 no.1
    • /
    • pp.29-38
    • /
    • 1997
  • A peripheral nerve when approximation of the ends imparts tension at the anastomosis and with a relatively long segment defect after excision of neuroma and neurofibroma cannnot be repaired by early primary suture. The one of the optimistic reconstruction method of severed peripheral nerves is to restore tension-free continuity at the repair site putting an autogenous nerve graft into the neural gap despite of ancipating motor or sensory deficit of the donor nerve area. To overcome the deficit of the autogenous nerve graft, several other conduits supplying a metabolically active environment which is able to support axon regeneration and progression, providing protection against scar invasion, and guiding the regrowing axons to the distal stump of the nerve have been studied. An author have used ipsilateral femoral vein, ipsilateral femoral vein filled with fresh thigh muscle, and autogenous sciatic nerve for the sciatic nerve defect of around 10 mm in length to observe the regeneration pattern in rat by light and electron microscopy. The results were as follows. 1. Light microscopically regeneration pattern of nerve fibers in the autogenous graft group was more abundant than vein graft and vein filled with muscle group. 2. On ultrastructural findings, the proxial end of the graft in various groups showed similar regenerating features of the axons, myelin sheaths, and Schwann cells. The fascicular arrangement of the myelinated and unmyelinated fibers was same regardless of the type of conduits. There were more or less increasing tendency in the number and the diameter of myelinated fibers correlated with the regeneration time. 3. In the middle of the graft, myelinated nerve fibers of vein filled with muscle group were more in number and myelin sheath was thinner than in the venous graft, but the number of regenerating axons in autogenous nerve graft was superior to that in both groups of the graft. The amount of collagen fibrils and amorphous materials in the endoneurial space was increased to elapsed time. 4. There was no difference in regenerating patterns of the nerve fibers of distal end of the graft. The size and shape of the myelinated nerve fbers were more different than that of proximal and middle portion of the graft. From the above results, the degree of myelination and regenerating activity in autogenous nerve is more effective and active in other types of the graft and there were no morphological differences in either ends of the graft regardless of regeneration time.

  • PDF

Gracilis Muscle Transplantation in Neglected Brachial Plexus Palsy (진구성 상완 신경총 마비에 대한 유리박근이식술)

  • Chung, Duke-Whan;Han, Chung-Soo;Ok, Jae-Chul;Cho, Chang-Hyun
    • Archives of Reconstructive Microsurgery
    • /
    • v.6 no.1
    • /
    • pp.73-79
    • /
    • 1997
  • Complete denervation after severe brachial plexus injury make significant muscle atrophy with loss of proper function. It is much helpful to reconstruct the essential function of the elbow flexion movement in patient with total loss of elbow flexion motion after brachial plexus lesion which was not recovered with nerve surgery or long term conservative treatment from onset. In whole arm type brachial plexus injury, if there were no response to neurotization or neglected from injury, the volume of the denervated muscle is significantely reduced month by month. About 18 months most of the muscle fibers change to fibrous tissues and markedly atrophied irreversibly, further waiting is no more meaningful from that period. Authors performed 14 cases of functioning gracilis muscle transfer from 1981 to 1995 with microneurovascular technique, neuromusculocutaneous free flaps were performed for reconstruction of lost elbow flexion function. Average follow-up period was 5 years and 6 months. We used couple of intercostal nerves as a recipient nerve which were anastomosed to muscular nerve from obturator nerve in all cases. Recipient vessels were three deep brachial artery and eleven brachial artery which were anastomosed to medial femoral circumflex artery with end to end or end to side fashion. Average resting length of the transplanted gracilis were 24 cm. We can get average 54 degree flexion range of elbow with fair muscle power from flail elbow. There were one case of muscle necrosis with lately developed thrombosis of microvascular anastomosed site which comes from insufficient recipient arterial condition, 3 cases of partial marginal necrosis of distal skin of the transplanted part which were not significant problem with spontaneously solved with time goes by gracilis muscle has constant neurovascular pattern with relatively easy harvesting donor with minimal donor morbidity. Especially it has similar length and shape with biceps brachii muscle of upper arm and longer nerve pedicle which can neurorrhaphy with intercostal nerve without nerve graft if sufficient mobilization of the nerves from both sides of gracilis and intercostal region. Authors can propose gracilis muscle transplantation with intercostal nerves neurotization is helpful method with minimal donor morbidity for neglected brachial plexus palsy patients.

  • PDF

Comparison the Preoperative MRI Findings with Postoperative Arthroscopic Findings on Meniscus Injury with Anterior Cruciate Ligament Rupture (전방십자인대 파열에 동반된 반월상 연골판 손상의 관절경 수술 소견과 수술 전 자기공명영상 검사와의 비교)

  • Sohn, Hong Moon;Lee, Gwang Chul;Kim, Dong Hwi;Park, Sang Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.2
    • /
    • pp.147-152
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the preoperative magnetic resonance image (MRI) findings with postoperative arthroscopic findings on meniscus injury with anterior cruciate ligament (ACL) rupture. Materials and Methods: We reviewed MRI images and arthroscopic findings of 225 patients treated by ACL reconstruction due to rupture, from February 2001 to November 2010. There were 154 cases of meniscus tear in arthroscopic findings. We examined the sensitivity for detecting meniscal tears varied with the presence of a rupture of the ACL, with the location of the tear within the meniscus, and among configurations of meniscal tears. Results: In the presence of a rupture of the ACL, the sensitivity of MRI was 0.88 for medial meniscal tears and 0.69 for lateral meniscal tears. And sensitivity of MRI was lowest in posterior horn and peripheral portion tears in lateral meniscus injury accompanying ACL rupture, sensitivity was low in anterior horn and flap shape tears in medial meniscus injury accompanying ACL rupture. Conclusion: In Meniscus injury with ACL rupture, a special attention shoulder given to the posterior horn and peripheral portion injury in lateral meniscus during arthroscopic surgery due to difficulty in detecting on MRI.

  • PDF

Reconstruction of body contour with digital camera image (Digital Camera의 영상을 이용한 신체 단면도 제작)

  • Kwon, KT;Kim, CM;Kang, TY;Park, CS;Song, HK
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.53-60
    • /
    • 2003
  • I. Purpose It is essential to have the correct body contour information for the calculation of dose distribution. The role of CT images in the radiation oncology field has been increased. But there still exists a method to use cast or lead wire for the body contour drawing. This traditional method has drawbacks such as in accurate and time consuming procedure. This study has been designed to overcome this problem. II. Materials and Methods A digital camera is attached to a pole which stands on the opposite side of the gantry. Positional information was acquired from an image of the phantom which is specially designed for this study and located on the isocenter level of the simulator Laser line on the patients skin or on the phantom surface was digitized and reconstructed as the contour. Verification of usefulness this technique has been done with various shape of phantoms and a patients chest III. Results and Conclusions Contours from the traditional method with the cast or lead wire and the digital image method showed good agreement within experimetal error range. This technique showed more efficiente in time and convenience. For irregular shaped contour, like H&N region, special care are needed. The results suggest that more study is needed. To use of the another photogrammatory techinique with two camera system may be better for the actual clinical application

  • PDF

Stress Analysis and Fatigue Failure of Prefabricated and Customized Abutments of Dental Implants (치과 임플란트에서 기성 지대주와 맞춤형 지대주의 응력분석 및 피로파절에 관한 연구)

  • Kim, Hee-Eun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.209-223
    • /
    • 2013
  • This study was to evaluate the stress distributions of prefabricated, customized abutments and fixtures according to their material and shape by three-dimensional finite element analysis. And to investigate the fatigue life and fracture characteristics. Mandibular models were fabricated by reconstruction of the CT scan of patients with normal occlusion. A total of six finite element models were designed, a load of 100 N was applied on the buccal cusps vertically, and 30 degree obliquely. 10 specimens each were fabricated for the more clinically widely used 4 type abutments and were loaded according to ISO 14801. Differences in stress distribution patterns were not found according to the materials of the abutments and fixtures. But a slight difference in the stress level was detected. Customized abutment groups showed lower crown stress levels. One-piece zirconia implant showed the lowest bone stress levels. In the fatigue test, highest values were measured in group 7. Prefabricated abutments showed less variation of fatigue life (P<0.05). Use of customized abutments can improve the fracture resistance of restorations. Especially, use of customized zirconia abutments reinforced by titanium screw connecting parts is recommended.

Hierarchical Image Encryption System Using Orthogonal Method (직교성을 이용한 계층적 영상 암호화)

  • Kim, Nam-Jin;Seo, Dong-Hoan;Lee, Sung-Geun;Shin, Chang-Mok;Cho, Kyu-Bo;Kim, Soo-Joong
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.3
    • /
    • pp.231-239
    • /
    • 2006
  • In recent years, a hierarchical security architecture has been widely studied because it can efficiently protect information by allowing an authorized user access to the level of information. However, the conventional hierarchical decryption methods require several decryption keys for the high level information. In this paper, we propose a hierarchical image encryption using random phase masks and Walsh code having orthogonal characteristics. To decrypt the hierarchical level images by only one decryption key, we combine Walsh code into the hierarchical level system. For encryption process, we first perform a Fourier transform for the multiplication results of the original image and the random phase mask, and then expand the transformed pattern to be the same size and shape of Walsh code. The expanded pattern is finally encrypted by multiplying with the Walsh code image and the binary phase mask. We generate several encryption images as the same encryption process. The reconstruction image is detected on a CCD plane by a despread process and Fourier transform for the multiplication result of encryption image and hierarchical decryption keys which are generated by Walsh code and binary random phase image. Computer simulations demonstrate that the proposed technique can decrypt hierarchical information by using only one level decryption key image and it has a good robustness to the data loss such as random cropping.

Evaluation of Total Lung Volume and Density using Multi-Detector Computed Tomography in Normal Dogs (정상견에서 다중채널 컴퓨터단층촬영술을 통한 폐용적과 밀도의 평가)

  • Choi, Ho-Jung;Lee, Ki-Ja;Choi, Soo-Young;Lee, Jung-Woo;Han, Woo-Sok;Lee, In;Kwon, Young-Hang;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.28 no.5
    • /
    • pp.510-515
    • /
    • 2011
  • This study was performed to quantitatively assess the normal lung volume and density according to the position by multi-detector computed tomography (MDCT) in dogs. Helical CT of the thorax was performed on 4 different positions with dorsal, left lateral, right lateral and ventral recumbency in 6 Pekingese and 6 Maltese dogs. During CT scanning, dogs were kept hyperventilated. Through the 3-dimensional reconstruction of CT images, the lung parameters were measured as the volume and density of the left, right including accessory lobe, and total lung. 3D images represented the different lung shape between Pekingese and Maltese dogs. Their difference of total lung volume and total lung density was not significant on the each position in both breeds. Right lung volume was significantly higher than left. The difference of left and right volume was $66.91{\pm}25.1$ ml. Linear relationship was shown between body weight and lung volume of ventral recumbency position. The dependent lung had higher density and lower volume than nondependent lung in both breed dogs. The volume of nondependent lung was not changed compared with the volume on ventral or dorsal recumbency. The total lung volume measured with MDCT is correlated with the lung density, and the lung density is useful to predict the normal total lung volume.