• 제목/요약/키워드: sewerage system

검색결과 109건 처리시간 0.021초

국내 정수장의 부식성 특성 연구 (Study on corrosion characteristics of treatment plants in Korea)

  • 민병대;정현미;이이내;최인철;안경희;박주현
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.707-714
    • /
    • 2016
  • In order to prevent secondary pollution of tap water, corrosion characteristics are investigated, and corrosion index are calculated using LI and LR to manage corrosiveness. As targeted water treatment plants from 2014 (July, once) to 2015 (July and October, 2 times), 70 plants are selected by making a division for each area and water system. (treated water samples, n=240, raw water samples, n=72). In result of pH analysis, treated water was lower than raw water to 7.12, and 7.29, respectively. LI were investigated in the order of Seomjin river, Nakdong river, Han river, Geum river, to -2.08, -1.24, -1.11, -1.10 (at raw water), and -2.18, -1.59, -1.51, -1.35 (at treated water), respectively. In case of water quality goal value (LI = -1) in Japan as control of corrosiveness, management object was investigated about 83.3%.

Evaluation of Proposed Diagnostic System for Detection of Pan-enterovirus Using Reverse Transcription Nested PCR from Water Environment

  • Siwon Lee;Kyung Seon Bae;Jin-Ho Kim;Ji-Hyun Park;Ji Hye Kim;Ji-Yeon Park;Kyung-Jin Lee;Chae-Rin Jeon;Jeong-Ki Yoon;Soo-Hyung Lee;Eung-Roh Park
    • 대한의생명과학회지
    • /
    • 제29권2호
    • /
    • pp.81-87
    • /
    • 2023
  • Pan-Enterovirus (Pan-EV) infects millions of children and infants worldwide every year. As severe infections have recently been reported, the need for monitoring has consequently intensified. Pan-EV is a categorical name for waterborne enteroviruses belonging to the Picornaviridae family, and includes a wide range of pathogens including Coxsackievirus (CoxV), Echovirus (EcoV) and Enterovirus (EV). In this study, we proposed an optimal RT-nested PCR method for diagnosis of various types of Pan-EV in an aquatic environment and developed a positive control. Considering detection sensitivity, specific reaction, and final identification, one condition capable of amplifying 478 bp among the four candidates in the 1st round PCR (RT-PCR) and one condition in the 2nd round PCR (nested PCR) were selected. Through the detection of nucleic acids extracted from 123 groundwater samples and the detection sensitivity test based on artificial spiking in the sample, the methods are optimal for non-disinfected water samples such as groundwater. We developed a positive control for Pan-EV detection that can be amplified to different sizes under the two conditions. Accuracy could be further improved by testing for contamination from the control group. The method proposed in this study and the positive control developed are expected to be used in monitoring Pan-EV in aquatic environments including groundwater through future research using more samples.

Dynamic Segmentation을 이용한 오수 관거 데이터구축에 관한 연구 (A Study on Building Sewerage Data using Dynamic Segmentation Method)

  • 박정우;윤정미;이성호
    • 한국지리정보학회지
    • /
    • 제9권2호
    • /
    • pp.11-19
    • /
    • 2006
  • 하수관망은 인간의 삶을 증진시키거나 홍수와 같은 재해를 예방한다. 그러나 우리나라의 경우 하수처리시설에 대하여 관심을 가질 뿐, 관로에 대한 관리는 지도(map)의 수준에서 벗어나지 못하고 있다. 선형 객체의 경우 한 개의 선형에 단일 속성만 존재한다. 이 한계로 인하여 하수관거와 같은 선형 속성은 관리하기 힘들고, 선형의 부분적인(point type, line type) 속성 변화는 처리할 수 없다. 이에 본 연구는 속성 변화를 적용시킬 수 있는 방법을 찾고 적용하고자한다. 이를 위하여 Dynamic Segmentation을 이용하였다. DS는 선형객체 상의 정확한 위치에 속성값을 부여할 수 있는 장점을 가지고 있다. 이를 이용하여 하수관거 주위의 다양한 환경 변화를 적용 시킬 수 있었다. 또한 관거별 최대하수량을 정밀하게 계산할 수 있었다.

  • PDF

간헐포기 활성슬러지 중수처리공정의 현장적용 연구 (A Study on the Field Application of Intermittently Aerated Activated Sludge Process for Water Reuse System)

  • 서인석;김병군;박승국;권선웅
    • 한국물환경학회지
    • /
    • 제16권4호
    • /
    • pp.513-521
    • /
    • 2000
  • Intermittently aerated activated sludge process was applied as a water reuse process of $70m^3/day$ for the upgrade of organic, nitrogen and phosphorus removal efficiency and clarifier performance. After application of the intermittently aeration, removal efficiency of BOD, SS, T-N and T-P were achieved 95%, 90%, 80% and 60%, respectively. Removal efficiencies in intermittently aerated process were considerably increased. comparing to those of continuously aerated activated sludge process. Also sludge rising problem in clarifier was improved. Average concentration of supplied reusing water were BOD 5 mg/L, turbidity 4 NTU and after chlorination, residual chlorine 0.4 mg/L, coliform 0 MPN/100mL. Intermittently aerated activated sludge process could be one of the best alternative process for the retrofit of conventional activated sludge process for the removal of nutrient in water reuse system.

  • PDF

충주댐 상류지역 하수도시설 확충사업에 관한 주민의 지불의사액 추정을 위한 CVM의 적용에 관한 연구 (Application of contingent valuation method for estimating willingness-to-pay in planning the integrated sewerage system in the catchment of Dam Chung-Ju)

  • 정동환;박규홍;진영선;조중무
    • 환경영향평가
    • /
    • 제13권2호
    • /
    • pp.73-86
    • /
    • 2004
  • The objective of this research was to estimate residents' willingness-to-pay using contingent valuation method and to investigate their environmental sensibilities prior to conduct the costbenefit analysis on the watershed management program of integrated sewerage construction and operation in the catchment of Dam Chung-Ju. A set of questionnaire was prepared and asked to 1,200 residents at downstream area as well as upstream area of Dam Chung-Ju. As a result, environmental sensibility of the residents living in the catchment of upstream of Lake Chung-Ju seemed very high. However, the substantial practice in their own life for conserving their environment was inactive, although residents' efforts trying to collect and dispose garbages in separate containers and to minimize the waste discharge load were actually made. The willingness-to-pay on each month for 20 years was estimated as 4,841 wons for the openended question and 3,411 wons for the close-ended question. Factorial analysis was also performed to obtain correlation among the questions asked. Seven groups of the correlated questions were identified and their contribution to the estimated willingness-to-pay was analyzed.

GIS 기반 불투수율 산정방법론을 활용한 강우유출수 부담금 모의산정 방안 연구 (A Study on the Calculation of Stormwater Utility Fee Using GIS based Impervious Surface Ratio Estimation Methodology)

  • 유재현;김계현;최지용;이철용
    • 한국물환경학회지
    • /
    • 제37권3호
    • /
    • pp.157-167
    • /
    • 2021
  • Korea needs to develop a rational system to separate stormwater utility fee from current sewerage fee. In this study, the scenario for calculating stormwater utility fee of Bupyeong-gu was suggested and the results were considered. For this purpose, the application of stormwater utility fee overseas and current domestic system were analyzed. A three step calculating scenario considering suitable domestic situation and impervious surface area was suggested. Water, sewerage usage, and hydrant data were collected. The total amount of water and sewerage fees for land use were calculated. The sewerage fee of Bupyeong-gu for the year 2014 was 21,685,446,578 won. Assuming that 40% of this amount was the cost associated to stormwater, the result showed that the fees for residential area in third step decreased by 0.77% compared to that of the first step. For commercial area, the stormwater utility fee decreased by 36.87%. For industrial area, although the consumption of water was similar to that of commercial area, the stormwater utility fee increased by 8.35%. For green area, the fee increased by 37.46%. This study demonstrated that the calculation of actual stormwater utility fee using impervious surface map and impervious Surface Ratio Estimation Methodology developed in previous studies is feasible.

침수방지와 방충.방취 기능을 갖는 오우배수장치의 개발 (The Development of Sewer Drainage for Harmful Insect and Bad Smell Prevention)

  • 김용석;박성호;양순용
    • 한국공작기계학회논문집
    • /
    • 제17권3호
    • /
    • pp.94-100
    • /
    • 2008
  • New type of the sewer drainage has been developed to overcome present sewer drainage's shortcoming. This system has the function of drainage, sewerage, reverse flow prevention, and harmful insect and smell prevention. Numerical simulation has been carried out in order to minimize the troubles that can be happened in the process of manufacture and installation process. This sewer drainage system for harmful insect and smell prevention intercepts pollution source, and then it prohibit second pollution. Harmful insect cannot go in and out in this system. Also, this system can reduce the damage of flooded districts due to heavy rain because it is impossible to flow backward from sewer drainage.