하수도용 연성관의 다짐정도에 따른 관거의 거동에 대한 사례연구 (A Case Study of between Pipe Deformation-Compaction Ratio using Flexible Sewer Pipe)

  • 김영진;이수헌;안창근;오진기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.1012-1017
    • /
    • 2010
  • Sewer Pipes are not being managed for twenty years after laying. So, The life span of sewer pipes is on the decrease. For solve the life span decrease of sewer pipes, correct checking of questions and measure preparation are necessary through investigation in sewer pipes. This research investigated on the state of sewer pipes in the housing and industrial sites through CCTV(closed-circuit television) and device of digitalized strain investigation. And, a result is as follows. A results of PE, PVC, GRP, CSP investigations were found of pipe-transformation state by earth pressure and external load.

  • PDF

천공장치를 이용한 배수설비 연결관 시공 기술에 관한 연구 (A Study for Drainage Pipe Construction Method using a Boring Machine)

  • 장재구;강선홍;김동은;정태호
    • 상하수도학회지
    • /
    • 제25권6호
    • /
    • pp.869-875
    • /
    • 2011
  • Ministry of Environment has been promoting BTL business of the sewer rehabilitation which continues from 2005 up to now. Sewer rehabilitation is classified into three parts : wastewater pipe rehabilitation, rainwater pipe rehabilitation and drainage equipment rehabilitation. Drainage equipment rehabilitation is that drainage pipe connects wastewater pipe directly without water-purifier. In the drainage equipment construction, it is inevitable to have the damage of ground structures(wall, gate and U drain, etc) when an open excavation method is used. Therefore it is necessary to develop non-excavation method to connect drainage pipe and wastewater pipe like jacking method to avoid the damage of ground structure. This paper has conducted an analysis of the non-excavation method using a boring machine attached to backhoe, which is issued the verification certificate of environmental technology according to the Development of and Support for Environmental Technology Act, article.7. The index set in this analysis was sectionalized to the condition of construction, the grade of drainage pipe, the size of excavated hole, the amount of waste cement concrete and asphalt concrete and the benefit effect compared to open excavation method.

경량 GFRP 패널을 이용한 하수관거공사용 복공 가시설 시스템의 개발 (Development of Lining-Board System Using Light-Weight GFRP Panels for Sewer-Pipe Construction)

  • 박신전;홍기증
    • 복합신소재구조학회 논문집
    • /
    • 제5권3호
    • /
    • pp.23-31
    • /
    • 2014
  • Recently, sewer-pipe constructions replacing deteriorated pipes are currently underway in the downtown area. To resolve many problems in the conventional method of open-cut construction, lining-board system using light-weight GFRP panels is developed. The pultruded GFRP panels can be successfully used for the developed lining-board system as temporary decks and retaining walls in virtue of light weight, high strength and high durability. In this paper, the structural safety and serviceability of the lining-board system are examined through FE analyses and experiments. Further more, a field application of the lining-board system is presented. The field application shows that quality and environment of construction can be significantly improved.

현장중심형 하수도용 연성관의 거동특성에 대한 고찰 - 다짐도·변형률·강성 간의 관계정립 - (A Case Study of Flexible Sewer Pipes Behaviors - Compaction Ratio·Inner Deflection Ratiov·Ring Stiffness -)

  • 김영진
    • 복합신소재구조학회 논문집
    • /
    • 제4권2호
    • /
    • pp.31-38
    • /
    • 2013
  • As the Sewer Pipe is transformed by the expansion of life cycle as a result of the technology development, flexible pipe is developed by the transformed environmental conditions. To change pipe design, three phases(compaction ration - inner deflection ratio - ring stiffness) should be considered in design conditions. The input data of pipe design were provided by compaction-inner deflection ratio-ring stiffness. M oreover, The guidelines of sewerage pipes should be considered by flexible pipes design criteria.

하수관로 주변 도로함몰 위험도 평가 방법에 관한 연구 (A Study on Risk Evaluation Method of Ground Subsidence around Sewer)

  • 김진영;최창호
    • 한국지반환경공학회 논문집
    • /
    • 제19권7호
    • /
    • pp.13-18
    • /
    • 2018
  • 최근 도심지를 중심으로 도로함몰이 증가하고 있어 시민들의 안전을 위협하고 있다. 도로 하부에는 상하수도관로, 전기통신시설 등 각종 도로시설물이 매설되어 있는데 이 시설물의 노후화가 도로 함몰의 원인으로 작용하고 있다. 특히, 도로함몰의 주된 원인으로 주목받고 있는 노후 하수관의 경우 단순히 매설연도에 의존하여 하수관 교체 및 보수보강 등의 관리가 이뤄지고 있으며, 하수관 상태에 의한 도로함몰의 위험성은 고려되지 않는 실정이다. 따라서, 본 연구에서는 다양한 하수관 제원 및 주변 환경 정보 및 CCTV 탐사 결과 및 GPR 탐사 결과를 고려한 신뢰성 있는 도로함몰 위험도 평가 방안을 제시하고자 하였다.

대규모 아파트 단지주변 하수관로의 악취 발생과 대책 II: 주거지역 하수관로의 악취원인과 대책 (The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures II: The Cause for Foul Odors of Sewer Pipes in Residential Areas)

  • 이장훈;강선홍
    • 상하수도학회지
    • /
    • 제21권5호
    • /
    • pp.631-639
    • /
    • 2007
  • This study investigated the construction and operation status of sewer pipes and water-purifier tanks near densely populated areas like large apartment complexes, in order to find out cause for offensive orders. The study results revealed that the main cause arose from the water-purifier tank and public sewer pipes near ordinary residential areas. First, in case of independent water-purifier tanks, the air is forced into the rotten part of large tanks nearby which should be operated in an anaerobic state, so that the tank changes into an aerobic state, or dirty water, which is returned during the sludge return process, falls on the top of the rotten tank, preventing scum from forming within the tank. Such problems cause incompletely purified water in the purifier tank to be discharged, which in turn results in filthy water. Second, in case of public sewer pipes, deteriorated or aging pipes, or the mixture of rain water and dirty water by mixing up combined and separated sewers system can cause foul odors in residential areas. Therefore, offensive odors in residential areas can be radically reduced through the appropriate construction and management of facilities including water-purifier tanks. As well, if more separate sewers are installed as part of an improvement project for public sewer pipes, complaints about foul smell can be minimized.

하수관로 돌출부 절삭을 위한 로봇장치 개발 및 절삭성능 평가 (Development of a Cutting Robot for Repairing Lateral Protrusions of the Sewer Pipe and Evaluation of Cutting Performance)

  • 양인환;황철성
    • 한국건설순환자원학회논문집
    • /
    • 제6권1호
    • /
    • pp.72-77
    • /
    • 2018
  • 본 연구에서는 하수관의 접합부 돌출부 절삭용 로봇을 개발하고, 이의 성능평가를 수행하였다. 하수관로 절삭 성능평가를 위해 주하수관의 재질 및 직경, 가지관의 재질을 실험변수로 설정하였다. 주하수관의 재질은 콘크리트 흄관과 PE관을 사용하고, 직경은 300 및 500mm를 적용하였다. 가지관의 재질은 PE 및 PVC로 설정하고, 직경은 100mm로 설정하였다. 절삭로봇을 개발된 이용하여 절삭성능 실험을 수행하였다. 절삭실험 후의 가지관의 잔여 돌출 길이는 5mm 이하로서 목표 절삭 잔여 길이를 모두 만족하고 있다. 따라서 개발된 하수관로 절삭로봇을 이용하여 하수관 접합부 돌출관을 효과적으로 절삭할 수 있다.

유리섬유를 이용한 하수관의 고강도 현장경화 비굴착 보수 공법 재료의 개발 및 물성 특성 연구 (Study of structural properties and development of high strength Cured-In-Place Pipe (CIPP) liner for sewer pipes using glass fiber)

  • 지현욱;;유성수;강정희
    • 상하수도학회지
    • /
    • 제34권2호
    • /
    • pp.149-159
    • /
    • 2020
  • Cured-in-place-pipe(CIPP) is the most adopted trenchless application for sewer rehabilitation to extend the life of the existing sewer without compromising both direct construction and indirect social costs especially applied in the congested urban area. This technology is globally and domestically known to be the most suitable for partial and full deteriorated pipe structure rehabilitation in a sewer system. The typical design of CIPP requires a significant thickness of lining to support loading causing sewage flow interruption and increasing material cost. This paper presents development of a high strength glass fiber composite lining material for the CIPP application and structural test results. The test results exhibit that the new glass fiber composite lining material has 12 times of flexural strength, 6.2 times of flexural modulus, and 0.5 Creep Retention Factor. These test results can reduce lining design thickness 35% at minimum. Even though taking into consideration extra materials such as outer and inner films for actual field applications, the structural capacity of the composite material significantly increases and it reduces 20 percent or more line thickness as compared to the conventional CIPP. We expect that the newly developed CIPP lining material lowers material costs and minimizes flow capacity reduction, and fully replaceable to the conventional CIPP lining materials.

도시침수 저감을 위한 최적 우수관망 설계 모형 (An Optimal Sewer Layout Model to Reduce Urban Inundation)

  • 이정호;김중훈;전환돈
    • 한국수자원학회논문집
    • /
    • 제44권10호
    • /
    • pp.777-786
    • /
    • 2011
  • 우수관망의 최적 설계에 관한 기존의 연구 모형들은 설계강우에 대하여 관거의 연결, 관경 및 관 경사 등을 최소의 비용을 목적으로 최적화하여 왔다. 그런데 우수관망에서의 관거 내의 흐름은 관경, 관 경사와 특히 관망의 구성 형태에 따라서크게달라진다. 기존의최적우수관망설계모형들은설계유량을만족시키는것에국한되었으며, 설계기준을초과하는 강우에 따른 침수의 발생은 관망의 설계에 어떠한 고려도 되지 않았다. 본 연구에서는 우수관망을 구성함에 있어서 관거 내 흐름을 분산시키고 제어함을 목적으로 한다. 이것은 관망 구성에 따른 관거 내 흐름의 중첩효과를 제어함으로써 가능하며, 이러한 흐름의 제어를 통하여 설계기준을 초과하는 강우에 대해서 우수관망에서의 내수침수 발생은 저감될 수 있다. 본 연구에의 최적 우수관망 설계 모형(Optimal Sewer Layout Model, OSLM)은 내수침수 발생을 저감시키기 위해 흐름의 중첩효과를 고려하여 관거 내 흐름을 분산시키고 제어하기 위하여 개발되었다. 이 모형은 최적화를 위하여 유전자알고리즘(Genetic Algorithm, GA)를 이용하였으며, 수리학적 분석을 위하여 SWMM(Storm Water Management Model)을 연계하였다. 모형의 적용은 유역면적 44 ha의 서울시 하계 배수분구에 이루어졌으며, 현재의 우수관망 구성에 대하여 도출된 최적 우수관망에서는 지속기간 30분의 설계강우에 대하여 7.1%의 유출구 첨두유출량 감소와 20년 빈도의 지속기간 1시간 초과강우에 대하여 24.2%의 침수 발생량 저감 효과를 나타내었다.

비굴착 하수관로용 PVC 프로파일 보수재 특성 평가 (Characterization of Repairing PVC profile for Trenchless Sewer Pipeline)

  • 박준하;전상렬;이관호
    • 한국산학기술학회논문지
    • /
    • 제16권7호
    • /
    • pp.4977-4983
    • /
    • 2015
  • 개착식 공법은 도로의 굴착에 따른 시간과 비용의 증가, 교통통제로 인한 민원발생 및 교통지정체 등 많은 문제점을 발생시키고 있다. 이러한 문제점을 해결하기 위하여 비굴착공법에 사용 가능한 하수관거 보수자재에 대한 실험을 시행하였다. 사용한 재료는 PVC프로파일이며, 국가표준시험 방법을 적용하여 기본 물성 평가를 시행하였다. 본 기술은 SPR(Sekisui Pipe Rehabilitation) 기술에 적용되는 프로파일보다 구조적 안정성이 높고, pipe integrity를 높일 수 있는 SWP(Spirally Wound Pipe)용 프로파일 구조를 적용하였다. 복합안정제의 함량을 5 phr을 이용하여 배합을 하였다. 시험 결과 복합안정제와 충격보강제를 투입한 경우에도 인장강도, 충격강도 및 연화온도가 표준의 물성을 만족함을 알 수 있었고, 가공시 부하가 없이 가공할 수 있었다. 접착 수지로 단부마감을 한 프로파일은 같은 압력에서 누수가 발생하지 않았다.