• Title/Summary/Keyword: sewage treatment system

Search Result 369, Processing Time 0.028 seconds

Optimum Sewage Discharge Strategy for Coastal Waters

  • Kang, Yun-Ho;Lee, Moon-Ock
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.10 no.S_3
    • /
    • pp.97-106
    • /
    • 2001
  • To improve the water quality, particularly for sea bathers, the behaviour of wastewater from sewage outfalls in water adjacent to Swansea, UK, was studied using a mathematical model. The water quality in the sewage receiving basin was determined using factors like the outfall diffuser location(distance from land boundary), sewage treatment scheme, discharge time, and bacteria decay rate, etc. With respect to these factors, an optimal strategy for sewage discharge was then investigated to minimize bacteria levels along the bathing beaches. As water quality criteria, predicted faecal coliform levels were monitored along the coast adjacent to the outfall locations. The resultant values were compared with EC Mandatory(<2000, 95 % of 20 samples) and Guideline Standards(< 100, 80 % of 20 samples). For the advective-diffusion equation, the non linear advective terms were represented using the ULTIMATE algorithm and the third-order accurate QUICKEST scheme to avoid numerical diffusion. Details of the simulation results are then presented as an optimal policy for sewage discharge in the region.

  • PDF

A Study on the Evaluation for Operations of Public Sewage Treatment Plants Using Statistics Technique (통계기법을 이용한 공공하수처리시설의 운영실태 평가방법 연구)

  • Choi, In-Cheol;Ahn, Tae-Ung;Yu, Soon-Ju;Chung, Hyen-Mi;Kwon, Oh-Sang;Kim, Won-Ky;Yeom, Ick-Tae;Son, Dae-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.5
    • /
    • pp.524-531
    • /
    • 2014
  • Korea has been trying to manage water quality of rivers and lakes in many ways. Ministry of Environment is making continuous efforts of operation control improvement such as strengthening effluent standards in sewage treatment plants and expanding Tele-Monitoring System (TMS). However, evaluation method for operations of sewage treatment plants and establishment system of effluent standards are inadequate. The objective of this study is to evaluate for operations of sewage treatment plants using statistics technique such as frequency analysis, percentile, normal distribution analysis. We used the effluent data (BOD, COD, SS) collected at 299 plants in 2012. The values were very low by comparison with standards. The Data followed a normal distribution. We think that distribution characteristics are closely related with effluent standards, especially T-P and BOD. Statistics technique attempted in this study can be used to evaluate for operations of sewage treatment plants and assess the appropriateness of effluent standards based on TBEL(Technology-based effluent limitation). And, this technique can be used to figure out the overall level of plants, the status of each plant and the favorable treatment process for each item (BOD, COD etc.). Data acquired through this method can be used to improve facilities and operation techniques and decide on a sewerage policy.

The Assessment on the Effect of Discharge and Variation of Water Quality from the Sewage Treatment Plants in Seoul (서울시 하수처리장 수질의 변동 및 방류수의 영향 평가)

  • Kwak Mi-Ae;Jung Jong-Heub;Eo Soo-Mi;Lee Hong-Keun
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.3 s.53
    • /
    • pp.1-12
    • /
    • 2004
  • This study was conducted to evaluate the variation characteristics of influent and effluent quality from sewage treatment facilities using activated sludge processes and to assess the impact caused by discharge of treated sewage on the receiving water Monthly data of five water quality items (BOD, COD, SS, T-N, T-P) were used to understand the water quality at three sewage treatment plants in Seoul for five years from 1999 to 2003. Concentration differences of water quality parameters were observed between upstream and downstream site at the sewage treatment plant outfall to investigate the impact of discharge in Tan stream and Han river basin. 1. Due to the effect of continuous improvement in sewer system, the concentrations of influent went on increasing generally. 2. Effluent concentrations of BOD, COD and SS showed the trend of a little decreasing, but the trend of increasing in T-N and T-P. 3. In Tan stream basin, the impact of sewage treatment plant discharge was not observed directly, because concentration of discharge was lower than stream water's. But discharges from sewage treatment plants affected water quality at downstream site in Han river, concentration of T-P especially.

Improvement for Asset Management of Sewage Treatment Facilities (하수처리시설 대수선비 자산화 영향분석 및 제도개선 방안)

  • Park, Ha Jin;An, Man Sun;Cho, Nam Ho;Kim, Kyong Ju
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2D
    • /
    • pp.285-293
    • /
    • 2011
  • Sewage treatment facilities are growing rapidly in quantitatively and qualitatively. However, privatization such as up-size and professionalism, etc. are insufficient, compared to global companies' cases. Infrastructure Asset management has not been applied widely despite of sewage treatment facilities are one of the most critical social infrastructure. Maintenance, repair, and rehabilitation (R&R) practices of sewage treatment facilities have been studied and infrastructures asset management techniques have been applied. Cost model which makes it possible to calculate managerial costs such as major cost, etc. needs to be developed only with project basic information when proceeding new sewage treatment facility construction and management and overseas sewage project. Effects to converse major repair cost into capital, application of sewage treatment facility's asset management, expected effects, etc. were analyzed and suggested an alternative on the improvements of legal system.

A Study on the Physical and Chemical Characteristics of the Constructed Wetland Soil for Sewage Treatment (오수처리용 인공습지내 토양의 이화학적 특성조사)

  • Yoon, Chun-Gyeong;Kwun, Tae-Young;Woo, Sun-Ho
    • Journal of Korean Society of Rural Planning
    • /
    • v.5 no.2 s.10
    • /
    • pp.24-29
    • /
    • 1999
  • The soil from constructed wetland system for sewage treatment was analyzed to examine physical and chemical characteristics. Clogging and lowered permeability were the physical matters of concern, and nutrient and salt accumulation were the chemical matters of concern. However, the soil properties of the constructed wetland system after 3 year operation demonstrated no degradation and still the soil works almost same as the initial stage. Encouragingly, no sludge accumulation was observed inside the system. Therefore, it implies that the wetland sewage treatment system can work continuously as long as it is operated and managed properly not to cause excessive pollutant loading.

  • PDF

A Study on Operation Control Technology Required for Introduction of Intelligent Sewage Treatment Plant (스마트 하수처리장 도입에 필요한 운전제어기술에 관한 연구)

  • Lee, Jiwon;Kim, Yuhyeon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.1
    • /
    • pp.38-43
    • /
    • 2022
  • Smart sewage treatment plant means creating a safe and clean water environment by establishing an ICT-based real-time monitoring, remote control management and intelligent system for the entire sewage treatment process. The core technology of such a smart sewage treatment plant can be operation control technology using measuring instruments. This research team analyzed and suggested the operation control technologies necessary for the establishment of the intelligent business by referring to the intelligent research projects of the sewage treatment plant in progress in Korea. As a result of the analysis, a total of six removal technologies were presented, including control by scale, reflow water control, linked treated water control, chemical quantity control, winter operation control, and total organic carbon control. By size, standards that can be classified into small and medium-sized large-scale are presented, and in the case of reflow water control, the location of water quality and flow sensors capable of managing reflow water is suggested. In the case of the linked treated water control, the influence and control points of the linked treated water on the sewage treatment plant were presented, and in the case of the chemical injection volume control, a system capable of optimizing the amount of chemical injection according to the introduction of an intelligent sewage treatment plant was presented. In the case of winter operation, the sensors and pumps to be controlled are suggested when considering the decrease in nitrification due to the decrease in water temperature. In the case of total organic carbon control, an interlocking system considering the total amount of pollution in the future was proposed. These operation control scenarios are expected to be used as basic data to be used in intelligent sewage treatment algorithms and scenarios in the future.

Effect of Municipal Sewage Treatment Plant on Water Quality in Western Kangwon Area (강원 영서지역 하수처리장이 수질에 미치는 영향)

  • Huh In-Ryang;Choi Ji-Yong;Kim Yeong-Jin;Jeong Ui-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.4 s.85
    • /
    • pp.235-240
    • /
    • 2005
  • The effects of municipal sewage treatment plants on the water quality and effluent loading were investigated. BOD removal rates from Wonju, Hoengseong, and Hongcheon municipal sewage treatment plants were $88.9\%,\;80.6\%,\;90.7\%$ and T-P removal rates were $47.3\%,\;56.5\%,\;71.6\%,$ respectively. Also, BOD effluent leading from WonJu, Hoengseong, and Hongcheon treatment plants were 1,520 kg/day, 75 kg/day, 55 kg/day and T-P effluent loading were 203.9 kg/day, 4.2 kg/day, 4.0 kg/day, respectively. In terms of water quality distribution by distance of flow, BOD of the Seom river rapidly rose from 1.6 mg/l to 4.0 mg/l and T-P rose from 0.034 mg/l to 0.321 mg/l. Also BOD of the Hongcheon river showed a slowly rise from 1.1 mg/l to 1.4 mg/l and T-P from 0.011 mg/l to 0.026 mg/l. In conclusion, the effects of municipal sewage treatment plants on the water quality proved that T-P was higher than BOD. Consequently, in order to improve water quality, it is necessary to adopt an advanced sewage treatment system like nutrient removal.

A Study on the Application of Natural Zeolite as Coagulant Aid for Effluent Quality Improvement in Private Sewage Treatment Facility (개인하수처리시설 처리수의 수질 개선을 위한 응집보조제로서의 천연제올라이트 적용에 관한 연구)

  • Choi, Jung Su;Joo, Hyun Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.1
    • /
    • pp.121-128
    • /
    • 2012
  • The purpose of this study is to solve the problem of nutrient removal due to rapid hydraulic retention time (HRT) variation in small size private sewage treatment facility and to have better effluent quality by using natural zeolite as a coagulant aid. The experiments were conducted by applying different conditions of HRT, coagulant, and zeolite dosages. As an experimental result, $TBOD_{5}$, TSS, and TP removal efficiencies were 64.9%, 94.5%, and 98.8% at co-injection with zeolite. Overall removal efficiencies of $TBOD_{5}$, TSS, and TP have improved 15.7, 28.7, 6.1%, respectively. This result shows that zeolite addition could improve flocculation, increase setting velocity, and thus have better treatment. Therefore the use of zeolite as a coagulant aid can be useful in small size private sewage treatment facility, where especially extra nutrient removal is required to meet the legal standard for discharge.

Application of $ENVIS^{(R)}$ MEMBRANE SYSTEM (Sumerged flat Sheet MF Membrane) ($ENVIS^{(R)}$ MEMBRANE SYSTEM (평판형 정밀여과막)의 침지식 수처리 공정 적용에 관한 연구)

  • Lee, Young-Moo;Jang, Jae-Young
    • Membrane Journal
    • /
    • v.15 no.3
    • /
    • pp.241-246
    • /
    • 2005
  • This study is investigated for the applications of MBR SYSTEM using $ENVIS^{(R)}$ which is a submerged flat membrane for treatment of sewage and wast water. The experiment was practiced on the scene of labor that are sewage facilities of factories $(10\;m^3/day)$ and wast water treatment plant $(30\;m^3/day)$ using equipments made by Pure-Envitech Co., LTD. SS, BOD and COD for the result of removal efficiency at the sewage facilities of factories were $99.7\%,\;97.6\%$, and $96.8\%$, rspectively. SS, BOD and COD for the result of removal efficiency at the waste water treatment plant were $99.6\%,\;95.6\%,\;and\;80.3\%$, respectively.

Sewage Treatment Using Water Hyacinth (Eichhornia crassipes) and Watercress (Oenanthe Javanica) (부레옥잠과 미나리를 이용한 연속식 하수처리에서 COD, N 및 P의 제거)

  • Park, Jin-Sick
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.2
    • /
    • pp.144-148
    • /
    • 2002
  • This study was carried out to investigate sewage treatment efficiencies using water hyacinth (Eichhornia crassipes) and watercress (Oenanthe Javanica). In the hyacinth system about 30% of COD introduced was removed during 2 days of hydraulic retention time, and about 30$\sim$50% of COD was removed in the watercress system during 1.2$\sim$2 days of hydraulic retention time. Therefore, COD loading of $76\sim170$ kg $COD/ha{\cdot}day$ was removed during 2$\sim$3 days of hydraulic retention time at the 0.18 $m^2$ area in the water hyacinth-watercress continuous system. Also 40$\sim$50% of N and P in the sewage were removed in the tested water hyacinth-watercress system Although COD, N and P concentrations in the final effluent were still higher than the limits of waste discharge, applicability of this waste water treatment system should be further investigated as an alternative method far small scale sewage treatments.