• Title/Summary/Keyword: setting function

검색결과 718건 처리시간 0.025초

진동가력과 양생온도가 라텍스개질 콘크리트에 미치는 영향 (Effects of Re-vibration and Curing Temperature on the Physical Properties of Latex-Modified Concrete)

  • 정원경;홍창우;이주형;윤경구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.799-804
    • /
    • 2003
  • The purpose of this study was to investigate the effects of re-vibration and curing temperature onto the physical properties of latex-modified concrete with ordinary cement and rapid-setting cement, and thus to provide a guide line of re-vibration and curing conditions for good quality controls. The main experimental variables included two cement types(ordinary portland cement, rapid-setting cement), curing Temperature($10^{\circ}C$, $20^{\circ}C$, $30^{\circ}C$), re-vibration methods(continued, intermittent), and re-vibration times(initial setting, one day after mixing). The experimental results showed that the re-vibration affected little to the mechanical properties of LMC and RSLMC, while, the curing temperature a quite some. The early strength development was the highest at $20^{\circ}C$ curing temperature, and decreased at higher temperature. The permeability of concrete generally decreased with curing time. The rapid chloride permeability was a function of time and temperature. The chloride permeability of RSLMC was so small and negligible.

  • PDF

발전기 보호제어를 위한 Bay Controller 설계에 관한 연구 (A Study on the Design of the Bay Controller for Generator Protection and Control)

  • 장낙원;우천희;이성환
    • 전기학회논문지P
    • /
    • 제57권1호
    • /
    • pp.46-55
    • /
    • 2008
  • In this paper, we designed the bay control unit that is based on the microprocessors and integrates with the new technology of electrical, electronic, and mechanical fields. Nowadays the customers have required much more integrated multi-protection relay, monitoring, control devices and power management for better and easier maintenance, performance, electrical system analysis and communication according to new trend of switchboard This bay controller supplies those requirements of customers with easy handling and operation. This bay controller provides a graphic display with rear-lit liquid crystal LCD and push buttons as kinds of HMI(Human Machine Interface). This bay controller provides the parameter setting program, control setting program, various editors and fault recording and analysis program on Windows/95/98/NT/2000/XP for HMI. In addition, this bay controller can be set manually and this manual setting function helps user to interface easily.

Development of a computer aided program for slipforming operations incorporating maturity approach

  • Hossain, K.M.A.;Anagnostopoulos, C.;Lachemi, M.
    • Computers and Concrete
    • /
    • 제3권2_3호
    • /
    • pp.177-195
    • /
    • 2006
  • Slipforming is a construction method in which the forms move continuously during the placement of concrete. This paper presents the development of a computer aided program designated as "CADSLIPFORM" for slipforming operations. The program incorporates maturity methods for the prediction of initial setting times of slipform concrete layers using laboratory data (time-temperature histories and setting times of concrete mixtures at different temperatures) and generates slipform mock-up times. The performance of CADSLIPFORM is validated by comparing simulated mock-up times with those estimated in the field through conventional hard front by rod (R) method. Moreover, the program versatility is demonstrated by illustrating mock-up simulations for different cases with variable slipform parameters such as: number and thickness of concrete layers, concrete temperature (simulating variable setting times) and slipform speed. The program also incorporates the choice of Freiesleben Hansen & Pederson (FHP) and Carino & Tank (CT) maturity functions. CADSLIPFORM can assist user to develop reliable schedule of slipforming operation suitable for a specific project by optimizing various slipform parameters.

변조전달함수 방법에서 엣지 장치 설정에 대한 각도 최적화 평가 (Evaluation of Angle Optimization on Edge Test Device Setting in Modulation Transfer Function)

  • 민정환;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권1호
    • /
    • pp.15-21
    • /
    • 2020
  • This study was purpose to evaluation of Modulation Transfer Function in Measurements by using the International electrotechnical commission standard(IEC 62220-1) which were edge device each angle by using edge method. In this study was Aero(Konica, Japan) image receptor which is a indirect Flat panel detector(FPD) was used. The size of matrix 1994 × 2430 (14"× 17" inch) which performed 12 bit processing and pixel pitch is 175 ㎛. The results of shown as MTF measurements at IEC standard. The amount of data seemed reasonable and at an MTF value of 0.1 the spatial frequencies were 2.56 cycles/mm at an angle of 2.4°. MTF value of 0.5 the spatial frequencies were 1.32 cycles/mm at an angle of 2.4°. This study were to evaluate MTF by setting each angle 2.0°~2.8° degrees the most effective optimal edge angle and to suggest the quantitative methods of measuring by using IEC.

Awareness and satisfaction of therapeutic goals on functional status in persons with hemiparetic stroke

  • Ahn, Si-Nae;Lee, Jeong-Weon;Hwang, Sujin
    • Physical Therapy Rehabilitation Science
    • /
    • 제7권1호
    • /
    • pp.1-5
    • /
    • 2018
  • Objective: Setting therapeutic goals assist to identify patient priorities and predict problem that may arise in performing daily and functional activities. Goal setting is associated with improved rehabilitation outcomes in individuals with hemiparetic stroke. This study was conducted to assess the effects of having awareness and satisfaction of goals on the functional status of individuals with hemiparetic stroke. Design: Cross-sectional study. Methods: Eighty-one people who had been diagnosed with stroke participated in this study. The study was conducted through a face-to-face surveys to identify participants' awareness and satisfaction of goals and standard assessment tools were used to evaluate patients' functional status. This study measured functional status through three clinical measures including the manual function test (MFT), Berg Balance scale (BBS), and modified Barthel index (MBI). Results: In participants with hemiparetic stroke, the MBI, BBS, and MFT scores were significantly higher in the participants who were aware of the therapeutic goal than in those who were unaware (p<0.05). The MBI, BBS, and MFT scores were not significant between the participants who were satisfied with the goal and those who were unsatisfied. Conclusions: This study suggests that having awareness in therapeutic goal-setting could lead to improvement of functional status in those with hemiparetic stroke. This study highlights how goal-setting can have a positive effect on persons with hemiparetic stroke.

Holographic Interferometry를 이용한 탄성 고무 인상재의 체적변화에 관한 연구 (DIMENSIONAL STABILITY OF ELASTOMERIC IMPRESSION MATERIALS USING HOLOGRAPHIC INTERFEROMETRY)

  • 하치양;이성복;우이형
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.574-592
    • /
    • 1996
  • This study investigated the time-dependent dimensional changes of elastomeric impression materials using holographic interferometry. Six commercial impression materials, Permlastic(polysulfide), Xantopren VL (condensation silicone), low and medium viscosity of Exafine, Provil (addition silicone), and Impregum(polyether), were selected. Steel plate was used as custom tray, and each impression specimen was 20 mm in width, 15 mm in length and 3 mm in thickness. Each impression material was evaluated at 30 minutes, 1, 2, 4, 6, 8 and 12 hours after setting using real-time holography. The results were as follow : 1. Xantopren VL and Permlastic showed relatively severe and continuous dimensional changes after setting. Low viscosity of Exafine, Provil, Impregum showed relatively slight dimensional changes with function of time and medium viscosity of Exafine showed almost no dimensional change from 2 hours after setting to 6 hours. 2. On initial dimensional changes within 1 hour, the amount of change in low viscosity of Exafine was the least and Xantopren VL was the largest. 3. On dimensional changes at 4 hours after setting, the amount of change in medium viscosity of Exafine was the least and tile change of Xantopren VL was the largest. 4. In overall dimensional stability during 12 hours, medium viscosity of Exafine was the most stable and Xantopren VL and Permlastic were least stable.

  • PDF

인지기능응용척도의 타당화를 위한 기초 연구 (A Preliminary Study for the Application of Cognitive Function Scale(ACFS) in Korean Setting)

  • 조은래;황해익
    • 아동학회지
    • /
    • 제31권3호
    • /
    • pp.235-254
    • /
    • 2010
  • The purpose of this study was to examine the feasibility and validity of the Application of Cognitive Function Scale as developed by Lidz and Jepsen (1997). Data were collected from 4 to 5-years-old children. The analysis for item adequacy indicated that the passing rate increases according to age. Futhermore the analysis for test adequacy indicated that internal consistency reliability was .85 in the pre-test and .80 of post-test in terms of the cognitive function scale, and .90 of pre-test and .93 in the post-test in relation to the behavior observation scale. In conclusion, our analysis of the ACFS shows sufficiently high scores in terms of both validity and reliability, so as to indicate that this test is an appropriate way to measure the cognitive function and non-intellective function of young Korean children.

교수학적 처방에 따른 중학생들의 일차함수 오개념의 변화와 그 효과 분석 (Analysis of the Error-Remedial Effect and Change of the Students' Misconception on the Learning of Linear Function)

  • 이종희;김부미
    • 대한수학교육학회지:학교수학
    • /
    • 제5권1호
    • /
    • pp.115-133
    • /
    • 2003
  • 본 연구는 중학교 2학년 학생들의 일차함수에 대한 오개념을 탐구하여 범주화하고, 일차 함수의 개념 학습과정에서 학생들의 오개념을 교정하고자 설명식 교수·학습 방법과 동료간의 상호 작용을 통한 협동 학습 방법을 각각 실시했을 때의 효과를 비교·분석하였다. 그리고, 학생들이 동료간의 협동적 상호 작용을 하면서 개별적으로 구성한 오개념이 어떻게 변화, 발전하는 지를 탐색하였다. 연구 결과, 대수적 환경에서의 학생들의 오개념은 수 개념에 의한 장애, 변수 개념 부족에 의한 장애, 특정관점에의 집착으로 분류되고. 그래프적 환경에서 학생들의 오개념은 함수그래프의 해석과 판단에서의 장애, 변수 개념에 대한 장애로 범주화되었다. 상이한 교수학적 처방의 효과는 오개념의 범주에 따라 각각 다르게 나타났으나, 교정 학습 후에도 기존의 인지 구조에 강하게 각인된 오개념은 계속해서 남아 있었다. 또한, 학생들의 오개념 중 일부는 단순히 잘못된 것이 아니라, 이를 발판 삼아 동료간의 협동 학습을 통하여 올바른 개념으로 변환될 수 있었다.

  • PDF

CONSTRUCTION OF MANY d-ALGEBRAS

  • Allen, Paul J.
    • 대한수학회논문집
    • /
    • 제24권3호
    • /
    • pp.361-366
    • /
    • 2009
  • In this paper we consider constructive function triples on the real numbers $\mathbb{R}$ and on (not necessarily commutative) integral domains D which permit the construction of a multitude of d-algebras via these constructive function triples. At the same time these constructions permit one to consider various conditions on these d-algebras for subsets of solutions of various equations, thereby producing geometric problems and interesting visualizations of some of these subsets of solutions. In particular, one may consider what notions such as "locally BCK" ought to mean, certainly in the setting provided below.

HARMONIC CONJUGATES OF WEIGHTED HARMONIC BERGMAN FUNCTIONS ON HALF-SPACES

  • Nam, Kye-Sook;Yi, Heung-Su
    • 대한수학회논문집
    • /
    • 제18권3호
    • /
    • pp.449-457
    • /
    • 2003
  • On the setting of the upper half-space of the Euclidean space $R^{n}$, we show that to each weighted harmonic Bergman function $u\;\epsilon\;b^p_{\alpha}$, there corresponds a unique conjugate system ($upsilon$_1,…, $upsilon_{n-1}$) of u satisfying $upsilon_j{\epsilon}\;b^p_{\alpha}$ with an appropriate norm bound.