• 제목/요약/키워드: set-up accuracy

검색결과 381건 처리시간 0.028초

열연 권취기의 오프라인 시뮬레이터에 관한 연구 (Study for the dowincoiler's offline simulator)

  • 최용준;이민철
    • 한국정밀공학회지
    • /
    • 제23권2호
    • /
    • pp.65-72
    • /
    • 2006
  • Downcoiler is one of the major facilities in hot strip mill operation. The key to good coiling is having good equipment, modem control systems, excellent maintenance and an understanding of coiling process. Therefore, this study aims to develop a program that is useful for calculating machine design parameters and simulating coiling process. In this study, the pinching and coiling mechanism of the downcoiler was thoroughly studied and some of operational factors and their effects on the coiling process were investigated. The software was developed to estimate engineering parameters for coiler component design and to determine optimal setting values for successful coiling operation. In order to check the accuracy and usefulness of the developed software, the simulation of the downcoiler in $\#2$ Hot Strip Mill in Pohang Works was performed. The simulation results suggested that the set-up value for unit tension could be lowered. Test coiling operation by using the lowered set-up value for unit tension resulted in much more successful coiling in the aspect of strip quality and power consumption.

신포괄수가 시범사업 모형 개선 이후의 지불정확도 변화 (The Effect of Reform of New-Diagnosis Related Groups (KDRGs) on Accuracy of Payment)

  • 최정규;김선희;신동교;강중구
    • 보건행정학회지
    • /
    • 제27권3호
    • /
    • pp.211-218
    • /
    • 2017
  • Background: Korea set up new diagnosis related group (DRG) as demonstration project in 2009. The new DRG was reformed in 2016. The main purpose of study is to identify the effect of reform on accuracy of payment. Methods: This study collected inpatient data from a hospital which contains medical information and cost from 2015 to 2016. The dependent variables were accuracy of total, bundled, unbundled payment, and payment for procedures. To analyze the effect of reform, this study conducted a multi-variate regression analysis adjusting for confounding variables. Results: The accuracy of payment increased after policy reform. The accuracy of total, bundled, unbundled payment, and payment for procedures significantly increased 3.90%, 2.92%, 9.03%, and 14.57% after policy reform, respectively. The accuracy of unbundled payment showed the largest increase among dependent variables. Conclusion: The results of study imply that policy reform enhanced the accuracy of payment. The government needs to monitor side effects such as increase of non-covered services. Also, leads to a considerable improvement in the value of cost unit accounting as a strategic play a role in development of DRG.

Improvement of Mass Flow and Thickness Accuracy in Hot Strip Finishing Mill

  • Lee, Man-Hyung;Yoon, Ji-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.73.3-73
    • /
    • 2001
  • Finishing mill (FM) is set up with rolling conditions (rolling speed, rolling force, roll gap, etc.) calculated by a FSU (Finisher Setup) model considering the temperature, qualities and size of a transfer bar and a strip at the entry and exit of FM before the transfer bar is rolled through FM. If the accuracy of setup is low mass flow unbalance occurs, so that the accuracies of the strip thickness and width become lower or rolling operation fault occurs. Therefore, to enhance the performance of the FSU model and to improve mass flow and the thickness accuracy of a strip in the 7-stand finishing mill using a hot strip speed measurement system. This study is being performed. In this paper, the speed measurement system, a developed neural network for predicting ...

  • PDF

A Quality Comparison of English Translations of Korean Literature between Human Translation and Post-Editing

  • LEE, IL-JAE
    • International Journal of Advanced Culture Technology
    • /
    • 제6권4호
    • /
    • pp.165-171
    • /
    • 2018
  • As the artificial intelligence (AI) plays a crucial role in machine translation (MT) which has loomed large as a new translation paradigm, concerns have also arisen if MT can produce a quality product as human translation (HT) can. In fact, several MT experimental studies report cases in which the MT product called post-editing (PE) as equally as HT or often superior ([1],[2],[6]). As motivated from those studies on translation quality between HT and PE, this study set up an experimental situation in which Korean literature was translated into English, comparatively, by 3 translators and 3 post-editors. Afterwards, a group of 3 other Koreans checked for accuracy of HT and PE; a group of 3 English native speakers scored for fluency of HT and PE. The findings are (1) HT took the translation time, at least, twice longer than PE. (2) Both HT and PE produced similar error types, and Mistranslation and Omission were the major errors for accuracy and Grammar for fluency. (3) HT turned to be inferior to PE for both accuracy and fluency.

Direct tracking of noncircular sources for multiple arrays via improved unscented particle filter method

  • Yang Qian;Xinlei Shi;Haowei Zeng;Mushtaq Ahmad
    • ETRI Journal
    • /
    • 제45권3호
    • /
    • pp.394-403
    • /
    • 2023
  • Direct tracking problem of moving noncircular sources for multiple arrays is investigated in this study. Here, we propose an improved unscented particle filter (I-UPF) direct tracking method, which combines system proportional symmetry unscented particle filter and Markov Chain Monte Carlo (MCMC) algorithm. Noncircular sources can extend the dimension of sources matrix, and the direct tracking accuracy is improved. This method uses multiple arrays to receive sources. Firstly, set up a direct tracking model through consecutive time and Doppler information. Subsequently, based on the improved unscented particle filter algorithm, the proposed tracking model is to improve the direct tracking accuracy and reduce computational complexity. Simulation results show that the proposed improved unscented particle filter algorithm for noncircular sources has enhanced tracking accuracy than Markov Chain Monte Carlo unscented particle filter algorithm, Markov Chain Monte Carlo extended Kalman particle filter, and two-step tracking method.

An evaluation system for determining the stress redistribution of a steel cable-stayed bridge due to cable stress relaxation at various temperatures

  • Tien-Thang Hong;Duc-Kien Thai;Seung-Eock Kim
    • Steel and Composite Structures
    • /
    • 제46권6호
    • /
    • pp.805-821
    • /
    • 2023
  • This study developed an evaluation system to explore the effect of the environmental temperature on the stress redistribution produced by cable stress relaxation of structural members in a steel cable-stayed bridge. The generalized Maxwell model is used to estimate stress relaxation at different temperatures. The environmental temperature is represented using the thermal coefficients and temperature loads. The fmincon optimization function is used to determine the set of stress relaxation parameters at different temperatures for all cables. The ABAQUS software is employed to investigate the stress redistribution of the steel cable-stayed bridge caused by the cable stress relaxation and the environmental temperature. All of these steps are set up as an evaluation system to save time and ensure the accuracy of the study results. The developed evaluation system is then employed to investigate the effect of environmental temperature and cable type on stress redistribution. These studies' findings show that as environmental temperatures increased up to 40 ℃, the redistribution rate increased by up to 34.9% in some girders. The results also show that the cable type with low relaxation rates should be used in high environmental temperature areas to minimize the effect of cable stress relaxation.

모터 동력계를 이용한 공작기계용 NC제어기 시스템의 위치제어 특성 분석을 위한 측정 연구 (A Measuring Method for Positioning Characteristics Analysis of NC Machine Controller using Dynamometer)

  • 김형곤;안동율;이응석
    • 대한기계학회논문집A
    • /
    • 제29권5호
    • /
    • pp.770-776
    • /
    • 2005
  • The gains fur NC controller parameter are fixed when the controller is combined with a machine. However, the characteristics of controller could be changed as it has being used by the machine or other environmental conditions. Those result in that the tool positioning accuracy is influenced. The loading torque in servo motor influences on the tool positioning accuracy and it is controlled by the parameter gains. It is required to analyze the torque variation with angular positioning accuracy of the servo motor. This study focus on a measuring method and device for verifying angular positioning accuracy of NC servo motor. We used a high resolution An converter for acquiring analogue signal of rotary encoder in servo motor. The positional accuracy for a nominal tool path, which is generated by the combination of axial movements (X,Y,Z), is analyzed with the servo motor torque. The current variation signal is acquired at the power line using a hall sensor and converted to the loading torque of servo motor. The method of measurement and analysis proposed in this study will be used for determining the gains of parameter in NC controller. This gain tuning is also necessary when the controller is set up at a machine.

EPID (Electronic Portal Imaging Device)의 유용성에 관한 고찰 (Review on Usefulness of EPID (Electronic Portal Imaging Device))

  • 이충원;박도근;최아현;안종호;송기원
    • 대한방사선치료학회지
    • /
    • 제25권1호
    • /
    • pp.57-67
    • /
    • 2013
  • 목 적: 방사선 치료 중 정확한 환자의 셋업 확인과 선량 측정용으로 사용되었던 film을 대신 하여 현재는 전자포탈영상장치(EPID)가 장착된 장비가 증가하고 있다. 이에 본 논문은 전자포탈영상장치 사용 시 자세확인의 정확성과 선량측정의 유용성을 평가해 보고자 한다. 대상 및 방법: 대한방사선치료학회, 대한방사선종양학회, Pubmed에서 "EPID", "Portal dosimetry", "Portal image", "Dose verification", "Quality control", "Cine mode", "Quality - assurance", "In vivo dosimetry"와 같은 용어로 검색하여 획득한 50개의 자료(1997~2012)를 대상으로 EPID의 역사와 선량측정(dosimetry), 자세확인(set-up verification), EPID 특성으로 구분하여 EPID의 유용성을 분석 하였다. 결 과: EPID는 1세대 Liquid-filled ionization chamber, 2세대 Camera based fluroscopic, 3세대 Amorphous-silicon 순으로 발전하였으며, EPID 촬영 모드에는 크게 EPID mode, Cine mode, Integrated mode로 나뉜다. 필름과 EPID의 절대선량정확성 평가를 한 결과 EPID는 1%, EDR2 필름은 3% 이내로 나타나 오차 측정 정확도가 필름에 비해 EPID가 우수하다는 것을 알 수 있었고, 치료계획 시스템으로부터 계산된 기준 조사면과 EDR2 필름, EPID로 측정한 기준 조사면의 선량 분포를 중첩하여 감마 분석한 결과 필름과 EPID 모두 허용기준 3%/3 mm와 2%/2 mm에서 감마값이 1을 초과하는 화소(r%>1)가 전체 화소의 2% 이내였다. 또한 업무 부하 비교에 있어 세기조절방사선 치료에서 전 과정 QA를 수행하는데 소요되는 시간은 EDR2 필름이 약 110분, EPID가 약 55분으로 측정되었다. 결 론: 전자포탈영상장치의 이용은 선량측정과 자세확인에 있어 기존의 복잡하고 번거로웠던 film과 전리조(Ionization chamber)를 대체하기에 충분하였으며, 특히 세기조절방사선치료의 정도관리에 있어 매우 유용하고 효율적이며 정확한 선량 측정 장치임을 알 수 있었다. 또한, 전자포탈영상장치를 이용한 Cine mode 촬영은 횡격막의 움직임에 따라 유동성이 큰 폐와 간의 경우나 자세의 안정성이 불안한 직장암 환자의 경우 추가 선량 없이 실시간으로 종양의 위치를 확인 할 수 있다는 장점이 있어 최적의 방사선 치료 구현이 가능하리라 사료된다.

  • PDF

Air-coupled ultrasonic tomography of solids: 2 Application to concrete elements

  • Hall, Kerry S.;Popovics, John S.
    • Smart Structures and Systems
    • /
    • 제17권1호
    • /
    • pp.31-43
    • /
    • 2016
  • Applications of ultrasonic tomography to concrete structures have been reported for many years. However, practical and effective application of this tool for nondestructive assessment of internal concrete condition is hampered by time consuming transducer coupling that limits the amount of ultrasonic data that can be collected. This research aims to deploy recent developments in air-coupled ultrasonic measurements of solids, described in Part 1 of this paper set, to concrete in order to image internal inclusions. Ultrasonic signals are collected from concrete samples using a fully air-coupled (contactless) test configuration. These air coupled data are compared to those collected using partial semi-contact and full-contact test configurations. Two samples are considered: a 150 mm diameter cylinder with an internal circular void and a prism with $300mm{\times}300mm$ square cross-section that contains internal damaged regions and embedded reinforcement. The heterogeneous nature of concrete material structure complicates the application and interpretation of ultrasonic measurements and imaging. Volumetric inclusions within the concrete specimens are identified in the constructed velocity tomograms, but wave scattering at internal interfaces of the concrete disrupts the images. This disruption reduces defect detection accuracy as compared with tomograms built up of data collected from homogeneous solid samples (PVC) that are described in Part 1 of this paper set. Semi-contact measurements provide some improvement in accuracy through higher signal-to-noise ratio while still allowing for reasonably rapid data collection.

근전도 신호기반 손목 움직임의 추정을 위한 다중 특징점 추출 기법 알고리즘 (Improvements of Multi-features Extraction for EMG for Estimating Wrist Movements)

  • 김서준;정의철;이상민;송영록
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.757-762
    • /
    • 2012
  • In this paper, the multi feature extraction algorithm for estimation of wrist movements based on Electromyogram(EMG) is proposed. For the extraction of precise features from the EMG signals, the difference absolute mean value(DAMV), the mean absolute value(MAV), the root mean square(RMS) and the difference absolute standard deviation value(DASDV) to consider amplitude characteristic of EMG signals are used. We figure out a more accurate feature-set by combination of two features out of these, because of multi feature extraction algorithm is more precise than single feature method. Also, for the motion classification based on EMG, the linear discriminant analysis(LDA), the quadratic discriminant analysis(QDA) and k-nearest neighbor(k-NN) are used. We implemented a test targeting twenty adult male to identify the accuracy of EMG pattern classification of wrist movements such as up, down, right, left and rest. As a result of our study, the LDA, QDA and k-NN classification method using feature-set with MAV and DASDV showed respectively 87.59%, 89.06%, 91.75% accuracy.