• 제목/요약/키워드: service load assessment

검색결과 66건 처리시간 0.024초

Interface friction in the service load assessment of slab-on-girder bridge beams

  • Seracino, R.;Kerby-Eaton, S.E.;Oehlers, D.J.
    • Steel and Composite Structures
    • /
    • 제5권4호
    • /
    • pp.259-269
    • /
    • 2005
  • Many slab-on-girder bridges around the world are being assessed because they are approaching the end of their anticipated design lives or codes are permitting higher allowable loads. Current analytical techniques assume that the concrete and steel components act independently, typically requiring full-scale load testing to more accurately predict the remaining strength or endurance of the structure. However, many of the load tests carried out on these types of bridges would be unnecessary if the degree of interaction resulting from friction at the steel-concrete interface could be adequately modeled. Experimental testing confirmed that interface friction has a negligible effect on the flexural capacity of a slab-on-girder beam however, it also showed that interface friction is significant under serviceability loading. This has led to the development of an improved analytical technique which is presented in this paper and referred to as the slab-on-girder mixed analysis service load assessment approach.

슬래브교의 피로도 평가 전문가 시스템 (Development of Expert System for Fatigue Assessment of Slab Bridge)

  • 오병환;김세훈;박종범;김지상
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.396-401
    • /
    • 2003
  • For a realistic and reasonable determination of condition and status, assessment system should include load modeling for the loads acting on slab bridges due to traffic loads, evaluation system for fatigue, and determination of remaining service life. The purpose of the present study is to develop a realistic expert system which can estimate reasonably the fatigue and service life of slab bridges, based on the load models that are derived from the traffic loads.

  • PDF

Ancillary Service Requirement Assessment Indices for the Load Frequency Control in a Restructured Power System with Redox Flow Batteries

  • Chandrasekar, K.;Paramasivam, B.;Chidambaram, I.A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1535-1547
    • /
    • 2016
  • This paper proposes various design procedures for computing Power System Ancillary Service Requirement Assessment Indices (PSASRAI) for a Two-Area Thermal Reheat Interconnected Power System (TATRIPS) in a restructured environment. In an interconnected power system, a sudden load perturbation in any area causes the deviation of frequencies of all the areas and also in the tie-line powers. This has to be corrected to ensure the generation and distribution of electric power companies to ensure good quality. A simple Proportional and Integral (PI) controllers have wide usages in controlling the Load Frequency Control (LFC) problems. So the design of the PI controller gains for the restructured power system are obtained using Bacterial Foraging Optimization (BFO) algorithm. From the simulation results, the PSASRAI are calculated based on the settling time and peak over shoot concept of control input deviations of each area for different possible transactions. These Indices are useful for system operator to prepare the power system restoration plans. Moreover, the LFC loop coordinated with Redox Flow Batteries (RFB) has greatly improved the dynamic response and it reduces the control input requirements and to ensure improved PSASRAI, thereby improving the system reliability.

공용중인 철도교량의 안전성 평가를 위한 궤도-교량 해석모델 개발 (Development of an Analytical Track-Bridge Model for Safety Assessment of Railway Bridge on Service Line)

  • 엄맥;강덕만;최정열;김만철;박용걸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1077-1092
    • /
    • 2007
  • The structural analysis model for estimate of load carrying capacity of railway bridge on service line is important to determine safety of bridges in service, we need to take response of bridge exactly, applying analysis model similar to the real railway bridge most. Track structure which is to distribute loads and decrease vibrations occurred from running train is constructed on the railway bridges. And it is important factor which should be considered to understand exact dynamic and static responses of bridge. But track structure is currently classified as a none structural members in the structural analysis model for estimating load carrying capacity of railway bridge and not considered in analysis model. That's the reason it is difficult to understand exact behavior of bridges. Therefore, the major objective of this study is to develop an analytical track-bridge model which is similar to real railway bridges considering track structure for safety assessment of railway bridge on service line to be effectively done.

  • PDF

연속 프리스트레스트 콘크리트 빔교의 안전성 평가에 관한 연구 (A Study on the Safety Assessment of the Continuous Prestressed Concrete Beam Bridge)

  • 채원규
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 1997년도 춘계 학술논문발표회
    • /
    • pp.31-36
    • /
    • 1997
  • In this thesis, the safety assessment method of the continuous prestressed beam bridge using the service load were studied. From the field test results of the continuous prestressed beam bridge, CAE(composite action factor) and $P_{n}$(capacity load of bridge) were assessed, and these factors were applied to safety assessment of the continuous prestressed beam bridge.

  • PDF

A Taxonomy of the Common Tasks and the Development of a Risk Index for Physical Load Assessment in Nursing Job

  • Ryoo, Jang Jin;Lee, Kyung-Sun;Koo, Jung-Wan
    • Safety and Health at Work
    • /
    • 제11권3호
    • /
    • pp.335-346
    • /
    • 2020
  • Background: Nursing service is a nonroutine work with an excessive physical load and diverse tasks. This study derived representative common tasks based on the frequently occurring tasks with a high physical load in the nursing workers' daily work and developed indicators to evaluate the work risk by reflecting the characteristics of nonroutine work. Methods: Common tasks were classified through the following stages: literature review, first focus group interview (FGI) with experts, first classification of common tasks, second FGI with hospital health managers, a survey of nursing service workers, and the final classification of common tasks for each task type. To develop an objective risk index for physical load assessment, we investigated the frequency and duration of the derived common tasks via survey. Results: Nursing common tasks were categorized into six task types and 56 subtasks. To evaluate the risks of various tasks in nonroutine works, three frequencies and three working time levels were defined by examining the task frequency and working hours. Exposure time was defined to reflect the characteristics of a nonroutine job. The final risk assessment was the product of the exposure time level and job intensity level. From this, four risk action levels were derived. Conclusion: This study has the advantage of solving the problem of focusing on some tasks in evaluating the physical load. It was meaningful in that a new risk assessment index based on exposure time was proposed based on the development of an evaluation scale for frequency and time by reflecting the characteristics of nonroutine work.

건설단계 BIM을 이용한 건축물의 전 과정 CO2 평가 기법 제안에 관한 연구 (A Proposal of Life Cycle CO2 Assessment Techniques for Building in Construction Stage by BIM LOD)

  • 방준식;태성호;노승준;금원석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.53-54
    • /
    • 2012
  • This study is aimed at utilizing LCA processor with BIM LOD, eliciting the problems of the existing environmental assessment by constructing the database for environmental values of green buildings. For these objects, environmental load database of BIM construction material and evaluation process are presented, after matching BIM family based environmental load database which is available during evaluation stage, input-output tables and Korea LCI database to standard item code of public procurement service. It is a important factor in environmental assessment of building to develop database unit of standard item code for BIM and construction material. Thus, the results of this study are expected to provide basic data for improving effectiveness of construction through BIM based environmental load evaluation database. Furthermore, the provided environmental load database unit for construction material is considered to be available as basic information for BIM study by suggesting a processor connecting BIM with LCA and along with this, continuous examination on the connection process is needed.

  • PDF

지진하중을 받는 RC 격납건물의 열화에 따른 신뢰성 해석 (Time Dependent Reliability Analysis of the Degrading RC Containment Structures Subjected to Earthquake Load)

  • 오병환
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.233-240
    • /
    • 2000
  • Nuclear power plant structures may be exposed to aggressive environmental effects than may cause their strength and stiffness to decrease over their service lives, Although the physics of these damage mechanisms are reasonably well understood and quantitative evaluation of their effects on time-dependent structural behavior is possible in some instances such evaluations are generally very difficult and remain novel. The assessment of existing RC containment in nuclear power plants for continued service must provide quantitative evidence that they are able to withstand future extreme loads during a service period with an acceptable level of reliability. Rational methodologies to perform the reliability assessment can be developed from mechanistic models of structural deterioration using time-dependent structural reliability analysis to take earthquake loading uncertainties into account. The final goal of this study is to develop the reliability analysis of RC containment structures. The cause of the degrading is first clarified and the reliability assessment has been conducted. By introducing stochastic analysis based on random vibration theory the reliability analysis which can determine the failure probabilities has been established.

  • PDF

급속시공용 복합신소재 교량상부구조의 구조 성능 (Structural Performance of an Advanced Compsites Bridge Superstructure for Rapid Installation)

  • 지효선
    • 복합신소재구조학회 논문집
    • /
    • 제1권1호
    • /
    • pp.34-45
    • /
    • 2010
  • This paper describes the design, manufacturing process, testing, application, and assessment of capacity-ratings of the first all advanced composites bridge on a public highway system. In order to verify the bridge design prior to the field application, a sub-scale bridge superstructure was built and tested in the laboratory. The field load test results were compared with those of the finite element analysis for the verification of validity. To investigate its in-service performance, field load testing and visual inspections were conducted under an actual service environment. The paper includes the presentation and discussion for advanced composites bridge capacity rating based on the stress modification coefficients obtained from the test results. The test result indicates that the advanced composites bridge has no structural problems and is structurally performing well in-service as expected. Since these composite materials are new to bridge applications, reliable data is not available for their in-service performance. The results may provide a baseline data for future field advanced composites bridge capacity rating assessments and also serve as part of a long-term performance of advanced composites bridge.

  • PDF

Wind-induced fragility assessment of protruding sign structures

  • Sim, Viriyavudh;Jung, WooYoung
    • Wind and Structures
    • /
    • 제31권5호
    • /
    • pp.381-392
    • /
    • 2020
  • Despite that the failure of sign structure may not have disastrous consequence, its sheer number still ensures the need for rigorous safety standard to regulate their maintenance and construction. During its service life, a sign structure is subject to extensive wind load, sometimes well over its permissible design load. A fragility analysis of a sign structure offers a tool for rational decision making and safety evaluation by using a probabilistic framework to consider the various sources of uncertainty that affect its performance. Wind fragility analysis was used to determine the performance of sign structure based on the performance of its connection components. In this study, basic wind fragility concepts and data required to support the fragility analysis of the sign structure such as sign panel's parameters, connection component's parameters, as well as wind load parameters were presented. Fragility and compound fragility analysis showed disparity between connection component. Additionally, reinforcement of the connection system was introduced as an example of the utilization of wind fragility results in the retrofit decision making.