• 제목/요약/키워드: series connection

검색결과 464건 처리시간 0.024초

Drought over Seoul and Its Association with Solar Cycles

  • Park, Jong-Hyeok;Chang, Heon-Young
    • Journal of Astronomy and Space Sciences
    • /
    • 제30권4호
    • /
    • pp.241-246
    • /
    • 2013
  • We have investigated drought periodicities occurred in Seoul to find out any indication of relationship between drought in Korea and solar activities. It is motivated, in view of solar-terrestrial connection, to search for an example of extreme weather condition controlled by solar activity. The periodicity of drought in Seoul has been re-examined using the wavelet transform technique as the consensus is not achieved yet. The reason we have chosen Seoul is because daily precipitation was recorded for longer than 200 years, which meets our requirement that analyses of drought frequency demand long-term historical data to ensure reliable estimates. We have examined three types of time series of the Effective Drought Index (EDI). We have directly analyzed EDI time series in the first place. And we have constructed and analyzed time series of histogram in which the number of days whose EDI is less than -1.5 for a given month of the year is given as a function of time, and one in which the number of occasions where EDI values of three consecutive days are all less than -1.5 is given as a function of time. All the time series data sets we analyzed are periodic. Apart from the annual cycle due to seasonal variations, periodicities shorter than the 11 year sunspot cycle, ~ 3, ~ 4, ~ 6 years, have been confirmed. Periodicities to which theses short periodicities (shorter than Hale period) may be corresponding are not yet known. Longer periodicities possibly related to Gleissberg cycles, ~ 55, ~ 120 years, can be also seen. However, periodicity comparable to the 11 year solar cycle seems absent in both EDI and the constructed data sets.

어텐션 기반 게이트 순환 유닛을 이용한 수동소나 신호분류 (Passive sonar signal classification using attention based gated recurrent unit)

  • 이기배;고건혁;이종현
    • 한국음향학회지
    • /
    • 제42권4호
    • /
    • pp.345-356
    • /
    • 2023
  • 수동소나의 표적신호는 수초 내 세기의 변화를 갖는 협대역 고조파 특성과 로이드 거울 효과에 의한 장시간 주파수 변이 특성을 나타낸다. 본 논문에서는 지역 및 전역적 시계열 특징을 학습하는 게이트 순환 유닛 기반의 신호분류 알고리즘을 제안한다. 제안하는 알고리즘은 게이트 순환 유닛을 이용한 다층 네트워크를 구성하고 확장된 연결을 통해 지역 및 전역적 시계열 특징들을 추출한다. 이후 어텐션 메커니즘을 학습하여 시계열 특징들을 가중하고 수동소나 신호를 분류한다. 공개된 수중 음향 데이터를 이용한 실험에서 제안된 네트워크는 96.50 %의 우수한 분류 정확도를 보였다. 이러한 결과는 기존의 잔차 연결된 게이트 순환 유닛 네트워크과 비교하여 4.17 % 높은 분류 정확도를 갖는다.

The Steel Coupling Beam-Wall Connections Strength

  • 박완신;윤현도
    • 콘크리트학회논문집
    • /
    • 제18권1호
    • /
    • pp.135-145
    • /
    • 2006
  • In high multistory reinforced concrete buildings, coupled shear walls can provide an efficient structural system to resist horizontal force due to wind and seismic effects. Coupled shear walls are usually built over the whole height of the building and re laid out either as a series of walls coupled by beams and/or slabs or a central core structure with openings to accommodate doors, elevators walls, windows and corridors. A number of recent studies have focused on examining the seismic response of concrete, steel, and composite coupling beams. However, since no specific equations are available for computing the bearing strength of steel coupling beam-wall connections, it is necessary to develop such strength equations. There were carried out analytical and experimental studies to develop the strength equations of steel coupling beam-connections. Experiments were conducted to determine the factors influencing the bearing strength of the steel coupling beam-wall connection. The results of the proposed equations were in good agreement with both test results and other test data from the literature. Finally, this paper provides background for design guidelines that include a design model to calculate the bearing strength of steel coupling beam-wall connections.

자속구속형 초전도 전류제한기의 용량증대를 위한 동작특성 (Operating Characteristics of Capacity Increase in a Flux-Lock Type Superconducting Fault Current Limiter)

  • 남긍현;최효상;박형민;조용선;이나영;한태희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.200-202
    • /
    • 2006
  • We investigated the operating characteristics of a flux-lock type superconducting fault current limiters according to the number of the serial connection each the superconducting element at the additive polarity winding of a transformer. This SFCL consists of two coils wound in parallel on the same iron core, and the secondary coil is connected to the elements in series. Operating characteristics can be controlled by adjusting the inductances and the winding directions of the coils. It turns ratio between the primary and the secondary coils is 63:21. The analysis of voltage, current, and resistance in serial connection each element was performed to increase the applied voltage of flux-lock type SFCL. When the applied voltage was 200/$\sqrt{3}[V_{rms}]$ with three elements connected in seres, the peak value of the line current increased up to 26,24[A]. On the other hands, resistive SFCL increased up to 36.35[A], under the same conditions. This enabled the flux-lock type SFCL to be easy to increase the capacity of power system.

  • PDF

YBCO의 직렬연결에 따른 자속구속형 초전도 한류기의 퀜치특성 (Quench Characteristics of Flux-Lock Type Superconducting Fault Current Limiter According to The Number of YBCO)

  • 이상일;박형민;최효상
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권8호
    • /
    • pp.329-333
    • /
    • 2006
  • We investigated the quench characteristics of a flux-lock type superconducting fault current limiter (SFCL) depending on the number of the serial connection between the superconducting elements at the subtractive polarity winding of a transformer. The flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil through an iron core, and the secondary coil is connected to the superconducting elements in series. The operation of the flux-lock type SFCL can be divided into the subtractive and the additive polarity windings depending on the winding directions between the primary and secondary coils. In this paper, the analyses of voltage, current, and resistance of superconducting elements in serial connection were performed to increase the power capacity of flux-lock type SFCL. The power burden was reduced through the simultaneous quenching between the superconducting elements. This enabled the flux-lock type SFCL to be easy to increase the capacity of power system.

15 kVA급 박막형 초전도 전류제한기의 한류특성 (Characteristics of 15 kVA Superconducting Fault Current Limiters Using Thin Films)

  • 최효상;현옥배;김혜림;황시돌
    • 한국전기전자재료학회논문지
    • /
    • 제13권12호
    • /
    • pp.1058-1062
    • /
    • 2000
  • We investigated resistive superconducting fault current limites (SFCLs) fabricated using YBCO thin films on 2-inch diameter sapphire substrates. Nearly identical SFCL units were prepared and tested. The units were connected in series and parallel to increase the current and voltage ratings. A serial connection of the units showed significantly unbalanced power dissipation between the units. This imbalance was removed by introducing a shunt resistor to the firstly quenched unit. Parallel connection of the units increased the current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current 25 A$\_$peak/, was produced and successfully tested at a 220 V$\_$rms/circuit. From the resistance increase, we estimated that the film temperature increased to 200 K in 5 msec, and 300 K in 120 msec. Successive quenches revealed that this system is stable without degradation in the current limiting capability under such thermal shocks as quenches at 220 V$\_$rms/.

  • PDF

120 kW급 태양광 발전시스템 설치 및 실 계통연계 운전 결과 평가 (Test Results Grid Connection of 120 kW Power Generation System)

  • 황정희;안교상;임희천;김수창;김신섭
    • 한국수소및신에너지학회논문집
    • /
    • 제17권3호
    • /
    • pp.338-346
    • /
    • 2006
  • In this paper, the test results of medium-size(120 kW class) PV system which was installed in the Taeahn thermal power station of Korea Western Power Co., Ltd., were summarized for developing the practical technology to applicate high voltage grid connection PV system. The 120 kW photovoltaic system which was consisted of 1,300 modules, PCS, and 150 kVA transformer station has been operated since Aug. 05, 2005. For verifying the modeling results of PV system, the operation data was compared with modeling results which was executed commercial PSCAD/EMTD and Psim tools. An equivalent circuit model of a solar cell has been also used for solar array modeling. A series of parameters required for array modeling have been estimated from general specification data of a solar module. A PWM voltage source inverter(VIS) and its current control scheme have been analyzed by using P&O (perturbation and Observation) MPPT algorithms technique.

15 kVA급 저항형 초전도 한류기의 전류제한특성 (Characteristics of 15 kVA superconducting fault current limiter)

  • Choi, Hyo-Sang;Kim, Hye-Rim;Hwang, Si-Dole;Kim, Sang-Joon;Lim, Hae-Ryong;Kim, In-Seon;Hyun, Ok-Bae
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.272-275
    • /
    • 2000
  • We investigated a resistive superconducting fault current limiter (SFCL) fabricated using YBCO thin films on 2-inch diameter sapphire substrates. Nearly identical SFCL units were prepared and tested. The units were connected in series and parallel to increase the current and voltage ratings. A serial connection of the units showed significantly unbalanced power dissipation between the units. This imbalance was removed by introducing a shunt resistor to the firstly quenched unit. Parallel connection of the units increased the current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current 25 Ap, was produced and successfully tested at a 220 V circuit. From the resistance increase, we estimated that the film temperature increases to 200 K in 5 msec, and 300 K in 120 msec. Successive quenches revealed that this system is stable without degradation in the current limiting capability under such thermal shocks as quenches at 220 V.

  • PDF

원통형 고체산화물 연료전지 스택 제작 및 성능평가 (Fabrication and Performance Evaluation of Tubular Solid Oxide Fuel Cells Stack)

  • 김완제;이승복;송락현;박석주;임탁형;이종원
    • 한국수소및신에너지학회논문집
    • /
    • 제24권6호
    • /
    • pp.467-471
    • /
    • 2013
  • In present work, optimized the manufacturing process of anode-supported tubular SOFCs cell and stack were studied. For this purpose, we first developed a high performance tubular SOFC cell, and then made electrical connection in series to get high voltage. The gas sealing was established by attaching single cells to alumina jig with ceramic bond. Through these process, we can obtain such high OVP as around 15V, which means that the electrical connection and gas sealing were optimized. Finally we developed a new tubular SOFC stack which shows a maximum power of 65W @ $800^{\circ}C$.

냉간성형강 벽체패널의 연결부실험 (Connection Tests for Cold-Formed Steel Wall Panels)

  • 이영기
    • 대한토목학회논문집
    • /
    • 제34권3호
    • /
    • pp.739-746
    • /
    • 2014
  • 본 연구의 대상은 석고보드와 냉간성형강 스터드로 구성된 벽체용 합성패널이다. 양면의 석고보드 사이에 위치한 스터드는 나사로 연결되어 있고, 이와 같은 연결부의 부분합성거동을 정량화하여 나사접합부의 단위미끄럼을 유발하는 단위길이 당 전단하중($S_{slip}$)을 산정하는 것이 목적이었다. 실험방법은 1962 AISI규준을 기초로 하여 실시하였다. 본 연구에서 산정한 $S_{slip}$값을 이용한 이론적 추정치와 기 발표된 공칭축강도의 실험값과의 비교에서 만족할 만한 결과를 도출하였다. 그러므로 본 연구의 결과는 연구범위와 유사한 냉간성형강 부재의 해석과 설계에 있어 구조 기술자에게 가치가 있는 정보를 제공할 것이다.