• 제목/요약/키워드: sensor readout

검색결과 80건 처리시간 0.024초

1.5 V Sub-mW CMOS Interface Circuit for Capacitive Sensor Applications in Ubiquitous Sensor Networks

  • Lee, Sung-Sik;Lee, Ah-Ra;Je, Chang-Han;Lee, Myung-Lae;Hwang, Gunn;Choi, Chang-Auck
    • ETRI Journal
    • /
    • 제30권5호
    • /
    • pp.644-652
    • /
    • 2008
  • In this paper, a low-power CMOS interface circuit is designed and demonstrated for capacitive sensor applications, which is implemented using a standard 0.35-${\mu}m$ CMOS logic technology. To achieve low-power performance, the low-voltage capacitance-to-pulse-width converter based on a self-reset operation at a supply voltage of 1.5 V is designed and incorporated into a new interface circuit. Moreover, the external pulse signal for the reset operation is made unnecessary by the employment of the self-reset operation. At a low supply voltage of 1.5 V, the new circuit requires a total power consumption of 0.47 mW with ultra-low power dissipation of 157 ${\mu}W$ of the interface-circuit core. These results demonstrate that the new interface circuit with self-reset operation successfully reduces power consumption. In addition, a prototype wireless sensor-module with the proposed circuit is successfully implemented for practical applications. Consequently, the new CMOS interface circuit can be used for the sensor applications in ubiquitous sensor networks, where low-power performance is essential.

  • PDF

저잡음화 계측회로에 의한 다음극형 용존산소센서의 산소투과특성 (Oxygen Permeability Characteristics of the Multi-Cathode Type Dissolved Oxygen Sensor Using the Low Noise Measuring Circuit)

  • 이동희;김태진;김영환;성영권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.764-766
    • /
    • 1998
  • An evaluation method for oxygen permeable characteristics of the membrane covering to each cathode of multiple cathode - single anode type dissolved oxygen sensor, which has high reproducibility and is capable of measuring multiple components in solutions. For this purpose, a measuring circuit for the multiple cathode type DO sensor was designed to lower the noise signal by adapting a digital LPF to readout the sensor output accurately. Digital LPF is designed by setting up the transfer function to set the cutoff frequency to 10Hz, and the transfer function is programmed by C language, and then the filtering characteristics are evaluated with the simulation and experiments. Using this LPF added measuring circuit for the multiple cathode type DO sensor, we have obtained the calibration factor for each cathode to calibrate the variation of the output signals. The calibration factor was obtained by measuring the sensor output signal followed by oxygen partial pressure, using the same oxygen permeable membrane at each cathode of the multiple cathode type DO sensor.

  • PDF

LC 공진형 압력 센서를 이용한 돼지 경골 동맥의 실시간 혈압 측정 (Real-time Blood Pressure Monitoring in Porcine Tibial Artery Using LC Resonant Pressure Sensor)

  • 최원석;김진태;정연호
    • 한국전기전자재료학회논문지
    • /
    • 제25권6호
    • /
    • pp.445-450
    • /
    • 2012
  • We have developed an implantable wireless sensor for real time pressure monitoring of blood circulation system. MEMS (micro-electro-mechanical system) technology was adopted as a sensor development method. The sensor is composed of photolithographically patterned inductors and a distributed capacitor in gap between the inductors. A resulting LC resonant system produces its resonant frequency in range of 269 to 284 MHz at 740 mmHg. To read the resonant frequency changed by blood pressure variation, we developed a custom readout system based on a network analyzer functionality. The bench-top testing of the pressure sensors showed good mechanical and electrical functionality. A sensor was implanted into tibial artery of farm pig, and interrogated wirelessly with accurate readings of blood pressure. After 45 days, the sensor's electrical response and histopathology were studied with good frequency reading and biocompatibility.

Flexible tactile sensor array for foot pressure mapping system in a biped robot

  • Chuang, Cheng-Hsin;Liou, Yi-Rong;Shieh, Ming-Yuan
    • Smart Structures and Systems
    • /
    • 제9권6호
    • /
    • pp.535-547
    • /
    • 2012
  • Controlling the balance of motion in a context involving a biped robot navigating a rugged surface or a step is a difficult task. In the present study, a $3{\times}5$ flexible piezoelectric tactile sensor array is developed to provide a foot pressure map and zero moment point for a biped robot. We introduce an innovative concept involving structural electrodes on a piezoelectric film in order to improve the sensitivity. The tactile sensor consists of a polymer piezoelectric film, PVDF, between two patterned flexible print circuit substrates (FPC). Additionally, a silicon rubber bump-like structure is attached to the FPC and covered by a polydimethylsiloxane (PDMS) layer. Experimental results show that the output signal of the sensor exhibits a linear behavior within 0.2 N ~ 9 N, while its sensitivity is approximately 42 mV/N. According to the characteristic of the tactile sensor, the readout module is designed for an in-situ display of the pressure magnitudes and distribution within $3{\times}5$ taxels. Furthermore, the trajectory of the zero moment point (ZMP) can also be calculated by this program. Consequently, our tactile sensor module can provide the pressure map and ZMP information to the in-situ feedback to control the balance of moment for a biped robot.

기준신호 보상회로를 이용한 더블 샘플링 방식의 비냉각형 볼로미터 검출회로 설계에 관한 연구 (A Study on Double Sampling Design of CMOS ROIC for Uncooled Bolometer Infrared Sensor using Reference Signal Compensation Circuit)

  • 배영석;정은식;오주현;성만영
    • 한국전기전자재료학회논문지
    • /
    • 제23권2호
    • /
    • pp.89-92
    • /
    • 2010
  • A bolometer sensor used in an infrared thermal imaging system has many advantages on the process because it does not need a separate cooling system and its manufacturing is easy. However the sensitivity of the bolometer is low and the fixed pattern noise(FPN) is large, because the bolometer sensor is made by micro electro mechanical systems (MEMS). These problems can be fixed-by using the high performance readout integrated circuit(ROIC) with noise reduction techniques. In this paper, we propose differential delta sampling circuit to remove the mismatch noise of ROIC itself, the FPN of the bolometer. And for reduction of FPN noise, the reference signal compensation circuit which compensate the reference signal by using on-resistance of MOS transistor was proposed.

Electronics Design of the NISS onboard NEXTSat-1

  • Lee, Dae-Hee
    • 천문학회보
    • /
    • 제40권2호
    • /
    • pp.55.2-55.2
    • /
    • 2015
  • NISS is a unique spaceborne imaging spectrometer (R = 20) onboard the Korea's next micro-satellite NEXTSat-1 to investigate the star formation history of Universe in near infrared wavelength region (0.9 - 3.8 um), with a customized H1RG IR sensor(Jeong 2014). In this paper, we will introduce the compact electronics system (Fig. 1) as well as the novel readout method to reduce the 1/f noise for NISS.

  • PDF

더블패스 마하젠더 간섭계를 이용한 광섬유 레이저의 파장검출 (A wavelength readout of a fiber-optic tunable laser using a double-pass Mach-Zehnder Interferometer)

  • 박형준;김현진;송민호
    • 전자공학회논문지SC
    • /
    • 제46권1호
    • /
    • pp.43-48
    • /
    • 2009
  • 광섬유 격자 센서어레이용 파장가변 광섬유 레이저의 출력파장변화를 복조할 수 있는 시스템을 제안하였다. 광섬유 레이저는 반도체 광증폭기와 Fabry-Perot 필터를 이용하여 제작하였고, 더블패스 마하젠더 간섭계 구조를 적용하여, $90^{\circ}$위상차를 가지는 내부 트리거를 생성하였다. 내부 트리거를 이용하여 얻은 Lissajous 그래프에 원형 피팅을 적용하여 2.51 mrad의 평균위상오차를 얻었다. 실험을 통하여 파장가변필터의 비선형 동작 특성에 의한 광섬유 레이저의 비선형 출력을 확인하였다. 제안한 파장검출 방법을 적용하면 파장가변광원의 비선형성을 보상하여 광섬유격자 센서시스템을 위한 효율적인 광원으로 적용이 가능할 것으로 예상된다.

PC를 이용한 TLD 판독장치의 제작과 특성조사 (Construction of the TLD Readout System Using the Personal Computer and Its Characteristics)

  • 우홍;강희동;김도성
    • 센서학회지
    • /
    • 제7권5호
    • /
    • pp.342-349
    • /
    • 1998
  • 방사선 선량판독과 함께 열형광 현상의 연구가 가능한 다목적 TLD 판독장치를 제작하고 그 특성을 조사하였다. TLD에서 방출되는 열형광은 광전증배관과 전류-주파수 변환장치로 측정하였으며, 백금 열판을 사용하여 TLD를 가열하고 가온율을 선형적으로 변화시켰다. 개인용 컴퓨터와 interface board를 이용하여 전 장치를 제어하고 glow 곡선을 측정하였으며, 제어 소프트웨어로 자동이득조절이 가능하게 하였다. 제작한 TLD 판독장치는 선형적인 선량판독이 가능하였고 검출하한은 약 $10\;{\mu}Gy$였다.

  • PDF

Low-Noise MEMS Microphone Readout Integrated Circuit Using Positive Feedback Signal Amplification

  • Kim, Yi-Gyeong;Cho, Min-Hyung;Lee, Jaewoo;Jeon, Young-Deuk;Roh, Tae Moon;Lyuh, Chun-Gi;Yang, Woo Seok;Kwon, Jong-Kee
    • ETRI Journal
    • /
    • 제38권2호
    • /
    • pp.235-243
    • /
    • 2016
  • A low-noise readout integrated circuit (ROIC) for a microelectromechanical systems (MEMS) microphone is presented in this paper. A positive feedback signal amplification technique is applied at the front-end of the ROIC to minimize the effect of the output buffer noise. A feedback scheme in the source follower prevents degradation of the noise performance caused by both the noise of the input reference current and the noise of the power supply. A voltage booster adopts noise filters to cut out the noise of the sensor bias voltage. The prototype ROIC achieves an input referred noise (A-weighted) of -114.2 dBV over an audio bandwidth of 20 Hz to 20 kHz with a $136{\mu}A$ current consumption. The chip is occupied with an active area of $0.35mm^2$ and a chip area of $0.54mm^2$.

공통-모드 간섭 (CMI)에 강인한 2-전극 기반 심전도 계측 회로 (CMI Tolerant Readout IC for Two-Electrode ECG Recording)

  • 강상균;남경식;고형호
    • 센서학회지
    • /
    • 제32권6호
    • /
    • pp.432-440
    • /
    • 2023
  • This study introduces an efficient readout circuit designed for two-electrode electrocardiogram (ECG) recording, characterized by its low-noise and low-power consumption attributes. Unlike its three-electrode counterpart, the two-electrode ECG is susceptible to common-mode interference (CMI), causing signal distortion. To counter this, the proposed circuit integrates a common-mode charge pump (CMCP) with a window comparator, allowing for a CMI tolerance of up to 20 VPP. The CMCP design prevents the activation of electrostatic discharge (ESD) diodes and becomes operational only when CMI surpasses the predetermined range set by the window comparator. This ensures power efficiency and minimizes intermodulation distortion (IMD) arising from switching noise. To maintain ECG signal accuracy, the circuit employs a chopper-stabilized instrumentation amplifier (IA) for low-noise attributes, and to achieve high input impedance, it incorporates a floating high-pass filter (HPF) and a current-feedback instrumentation amplifier (CFIA). This comprehensive design integrates various components, including a QRS peak detector and serial peripheral interface (SPI), into a single 0.18-㎛ CMOS chip occupying 0.54 mm2. Experimental evaluations showed a 0.59 µVRMS noise level within a 1-100 Hz bandwidth and a power draw of 23.83 µW at 1.8 V.