• Title/Summary/Keyword: sensitivity experiment

Search Result 745, Processing Time 0.027 seconds

OPTIMAL SHAPE DESIGN OF A S-SHAPED SUBSONIC INTAKE USING NURBS (NURBS를 이용한 S형 천음속 흡입관 최적 설계)

  • Lee B.J.;Kim C.
    • Journal of computational fluids engineering
    • /
    • v.11 no.1 s.32
    • /
    • pp.57-66
    • /
    • 2006
  • An optimal shape design approach is presented for a subsonic S-shaped intake using aerodynamic sensitivity analysis. Two-equation turbulence model is employed to capture strong counter vortices in the S-shaped duct more precisely. Sensitivity analysis is performed for the three-dimensional Navier-Stokes equations coupled with two-equation turbulence models using a discrete adjoint method For code validation, the result of the flow solver is compared with experiment data and other computational results of bench marking test. To study the influence oj turbulence models and grid refinement on the duct flow analysis, the results from several turbulence models are compared with one another and the minimum number of grid points, which can yield an accurate solution is investigated The adjoint variable code is validated by comparing the complex step derivative results. To realize a sufficient and flexible design space, NURBS equations are introduced as a geometric representation and a new grid modification technique, Least Square NURBS Grid Approximation is applied With the verified flow solver, the sensitivity analysis code and the geometric modification technique, the optimization of S-shaped intake is carried out and the enhancement of overall intake performance is achieved The designed S-shaped duct is tested in several off-design conditions to confirm the robustness of the current design approach. As a result, the capability and the efficiency of the present design tools are successfully demonstrated in three-dimensional highly turbulent internal flow design and off-design conditions.

A Robust MRAC-based Speed Estimation Method to Improve the Performance of Sensorless Induction Motor Drive System in Low Speed (저속영역에서 센서리스 벡터제어 유도전동기의 성능을 향상시키기 위한 MRAC 기반의 강인한 속도 추정 기법)

  • 박철우;권우현
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.1
    • /
    • pp.37-46
    • /
    • 2004
  • A novel rotor speed estimation method using model reference adaptive control(MRAC) is proposed to improve the performance of a sensorless vector controller. In the proposed method, the stator current is used as the model variable for estimating the speed. In conventional MRAC methods, the relation between the two model errors and the speed estimation error is unclear. In the proposed method, the stator current error is represented as a function of the first degree for the error value in the speed estimation. Therefore, the proposed method can produce a fast speed estimation. The robustness of the rotor flux-based MRAC, back EMF-based MRAC, and proposed MRAC is compared based on a sensitivity function about each error of stator resistance, rotor time constant, mutual inductance. Consequently, the proposed method is much more robust than the conventional methods as regards errors in the mutual inductance, stator resistance. Therefore, the proposed method offers a considerable improvement in the performance of a sensorless vector controller at a low speed. In addition, the superiority of the proposed method and the validity of sensitivity functions were verified by simulation and experiment.

A High-sensitivity Passive Magnetic Transducer Based on PZT Plates and a Fe-Ni Fork Substrate

  • Li, Ping;Wen, Yumei;Jia, Chaobo;Li, Xinshen
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.271-275
    • /
    • 2011
  • This paper proposes a magnetoelectric (ME) composite transducer structure consisting of a magnetostrictive H-type Fe-Ni fork substrate and piezoelectric PZT plates. The fork composite structure has a higher ME voltage coefficient compared to other ME composite structures due to the higher quality (Q) factor. The ME sensitivity of the fork structure reaches 12 V/Oe (i.e., 150 V/cm Oe). The fork composite with two PZT plates electrically connected in series exhibits over 5 times higher ME voltage coefficient than the output of the rectangle structure in the same size. The experiment shows the composite of a Fe-Ni fork substrate and PZT plates has a significantly enhanced ME voltage coefficient and a higher ME sensitivity relative to the prior sandwiched composite laminates. By the use of a lock-in amplifier with 10 nV resolution, this transducer can detect a weak magnetic field of less than $10^{-12}$ T. This transducer can also be designed for a magnetoelectric energy harvester due to its passive high-efficiency ME energy conversion.

Development of Moving Magnet Type Optical Pickup Actuator (가동자석형 광 픽업 엑츄에이터의 개발)

  • Hur, Young-Jun;Kim, Yoon-Ki;Song, Myeong-Gyu;Kim, Sang-Ryong;Park, No-Cheol;Yoo, Jeong-Hoon;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.4 no.1
    • /
    • pp.23-28
    • /
    • 2008
  • In this paper we suggested the moving magnet type actuator for optical disc drive which has high frequency of flexible mode. Generally, moving magnet type actuator has the advantage for increase the frequency of flexible mode. But it has low driving sensitivity due to the weight of its moving part. To overcome this shortcoming, we designed the model with the closed electromagnetic circuit for tracking direction. In addition, we improved the driving sensitivity and frequency of flexible mode by using of DOE (design of experiment) procedure for EM circuit. Consequently, it is verified that final designed model satisfied with the desired specifications.

  • PDF

Improvement of the Ammonia Analysis by the Phenate Method in Water and Wastewater

  • Park, Ga-Eun;Oh, Ha-Na;Ahn, Sam-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.9
    • /
    • pp.2032-2038
    • /
    • 2009
  • The amount of phenol and NaOH for the colorimetric determination of ammonia in Korean standard methods (KSM) is found to be highly excessive compared to the standard methods of several other countries. The absorbance of indophenol formed by the Berthelot reaction for ammonia analysis was measured under the various reaction conditions classified in experiment groups 1, 2, 3, 4 and KSM and American standards methods (ASM), and the relationships between the absorbance of indophenol and concentration of ammonia were compared. The amount of phenol can be reduced to 10 g (current 25 g in KSM) and NaOH can be reduced to 1.76 g (current 11 g in KSM) for the preparation of 200 mL phenate solution, and the absorbance sensitivity increased. The concentration of the phenol and NaOH correlatively affect the pH of the solution, which is a critical variable in achieving the maximum sensitivity and rapid and stable color development.

Advanced On-chip SOL Calibration Method for Unknown Fixture De-embedding

  • Yoon, Changwook;Chen, Bichen;Ye, Xiaoning;Fan, Jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.4
    • /
    • pp.543-551
    • /
    • 2017
  • SOL (Short, Open and Load) calibration based on iterative error sensitivity is proposed in this paper. With advanced SOL calibration, unknown parasitic parameters at on-chip terminations are accurately estimated up to 20 GHz. Artificial terminations are designed on printed circuit board (PCB) to experiment the proposed method. On-chip SHORT, OPEN and LOAD fabricated inside silicon shows the accuracy of proposed calibration method through the comparison with known fixture S-parameter after de-embedding.

Performance Optimization of a Gas-Assisted Hydraulic Breaker with Dual Stroke (가스보조식 이중행정 유압브레이커의 성능 최적화)

  • Ryoo, Taek-Jik;Chang, Hyo-Whan
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.1
    • /
    • pp.11-19
    • /
    • 2010
  • A gas-assisted hydraulic breaker uses both hydraulic and pneumatic energies and the appropriate balance between them mostly effects its performance. Mathematical modeling of the breaker is established and verified by experiment. Through sensitivity analysis using AMESim, the key design parameters are selected, which mostly affect the performance of the breaker. Taguchi method is used to optimize the key design parameters to maximize the output power for long and short strokes through simulation. As the result, the output power as well as the impact energy are increased significantly compared with the existing design. The pressure pulsation in the supply line is reduced to a tolerable level and the dynamic characteristics of the piston displacement is also improved by the optimization.

  • PDF

2nd Order Deadbeat Controller Considering Calculation Time Delay and Sensitivity for UPS Inverter (연산시간지연 및 민감성을 고려한 UPS 인버터용 2차 데드비트 제어기)

  • Kim, Byoung-Jin;Choi, Jae-Ho;Jain , Amit
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.4
    • /
    • pp.170-178
    • /
    • 2001
  • Deadbeat technique has been proposed as a digital controller for an UPS inverter to achieve the fast, response to a load variation and to conserve a very low THD under a nonlinear load condition. This scheme contains a fatal drawback, sensitivity against parameter variation and calculation time delay. This paper proposes a second order deadbeat controller, which fundamentally solves the calculation time delay problem and certainly guarantees the robustness of the parameter's variation. RLP(Repetitive Load Predictor) which predicts the load current ahead of two sampling time and FVR(Fundamental Voltage Regulator) which eliminates the fundamental errors of the output voltage are also proposed for the second order deadbeat controller to apply to UPS inverter systems. These are shown theoretically and practically through simulation and experiment.

  • PDF

Identification of Parameter for Bearing Using Orbit Shapes (궤도형상 데이터를 이용한 베어링 파라미터 규명)

  • 이경백;김영배
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.672-675
    • /
    • 1997
  • This paper presents the identification of rotor dynamic parameters. The solution of the system equation can be obtained using least square method. The sensitivity analysis is performed to extract optimized solution, which is considered to be insensitive to inherent measurement errors. The cosine and sine term of orbit shapes can be obtained by experiment the orbit analysis at a different speed after doing orbit analysis at an arbitrary selected speed. This values measured time domain used to search the stiffness and damping coefficients of rotor bearing.

  • PDF

Vibration Analysis of Network Communication Equipment (네트워크 통신장비의 진동 해석)

  • Lee Jae-Hwan;Kim Jin-Sup;Kim Young-Jung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.467-472
    • /
    • 2006
  • The purpose of this paper is to check the structural safety of the network equipments by performing the static and dynamic finite element analysis. The stress and displacement of structures under static loading condition are evaluated to check whether satisfying the design requirement conditions. Since the computed natural frequencies are similar to the results of experiment. the model could be used for the response spectrum analysis where experimental acceleration value at each frequency are used as seismic input excitation. It is shown that the analysis results are a little bit larger than that of the experimental values. Also sensitivity analysis and optimization for the natural frequency are performed and it is found that the first natural frequency is very sensitive to the stiffness of the equipment.

  • PDF