• 제목/요약/키워드: sensitive detection

검색결과 1,717건 처리시간 0.025초

Evaluation of a Fabricated Charge Sensitive Amplifier for a Semiconductor Radiation Detector

  • Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Lee, Jae-Hyung;Lee, Cheol-Ho
    • Journal of Radiation Protection and Research
    • /
    • 제35권2호
    • /
    • pp.81-84
    • /
    • 2010
  • A CSA(Charge Sensitive Amplifier) was designed and fabricated for application in a radiation detection system based on a semiconductor detector such as Si, SiC, CdZnTe and etc.. A fabricated hybrid.type CSA was evaluated by comparison with a commercially available CSA. A comparison was performed by using calculation of ENC (Equivalent Noise Charge) and by using energy resolutions of fabricated radiation detectors based on Si. In energy resolution comparison, a fabricated CSA showed almost the same performance compared with a commercial one. In this study, feasibility of a fabricated CSA was discussed.

Liquid Crystal Droplet Patterns to Monitor Catalase Activity at Femtomolar Levels

  • Yoon, Stephanie;Jang, Chang-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권9호
    • /
    • pp.2704-2710
    • /
    • 2014
  • Catalase (CAT) decomposes hydrogen peroxide that is toxic to the body. In this study, simple and sensitive detector has been developed for observing catalase activity using liquid crystal droplet system. Microscale LC droplet patterns are formed by spreading aldehyde-doped nematic liquid crystal on pre-treated glass slides. When hydrogen peroxide is added, aldehyde is oxidized and amphiphiles are formed. Dodecanoates cause the pattern to transit from bright to dark as they self-assemble to form a carboxyalte monolayer at the interface. When a drop of pre-incubated CAT and hydrogen peroxide mixture is placed onto the pattern, bright fan-shape is observed. This planar optical appearance indicates that catalase has decomposed hydrogen peroxide. Compared to the detectors that have been previously developed, this system is more sensitive with detection limit of 1fM. This research suggests further studies to be on LC droplet patterning to develop highly sensitive and methodologically simple sensors for various chemicals.

Significance of a Highly Specific and Sensitive Enzyme Linked Immunosorbent Assay on Evaluation of Environmental Toxicant-Mediated Allergic Responses

  • Kim, Hyoung-Ah;Yong Heo
    • Toxicological Research
    • /
    • 제17권
    • /
    • pp.197-199
    • /
    • 2001
  • Enhancement of antigen-specific IgE is a hallmark of allergic hyperresponsiveness, therefore it is necessary to adopt or develop a highly sensitive and specific assay for determination of allergen-specific IgE levels in vivo. In this presentation, we introduce an ELISA (enzyme linked immunosorbent assay) system developed to measure the levels of chicken egg ovalbumin (OVA)-specific IgE in serum. The ELISA method uses a commercially available purified rat anti-mouse IgE as a capture Ab and biotinylated OVA as a detection reagent. Avidin-peroxidase with its substrate is used for color development resulting in optical density measurement at 405 nm. The ELISA system produces a highly sensitive dose-response relation-ship between optical density levels and the dilution titer of the OVA-IgE standard serum but no cross-reaction with unrelated IgE or IgG. It is believed that the system is an Efficient tool to delineate an adjuvant effect of environmental pollutants on development of asthmatic and atopic responses.

  • PDF

고집적 메모리를 위한 새로운 테스트 알고리즘 (A New Test Algorithm for High-Density Memories)

  • Kang, Dong-Chual;Cho, Sang-Bock
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(2)
    • /
    • pp.59-62
    • /
    • 2000
  • As the density of memories increases, unwanted interference between cells and coupling noise between bit-lines are increased and testing high density memories for a high degree of fault coverage can require either a relatively large number of test vectors or a significant amount of additional test circuitry. From now on, conventional test algorithms have focused on faults between neighborhood cells, not neighborhood bit-lines. In this paper, a new algorithm for NPSFs, and neighborhood bit-line sensitive faults (NBLSFs) based on the NPSFs are proposed. Instead of the conventional five-cell and nine-cell physical neighborhood layouts to test memory cells, a three-cell layout which is minimum size for NBLSFs detection is used. To consider faults by maximum coupling noise by neighborhood bit-lines, we added refresh operation after write operation in the test procedure(i.e., write \longrightarrow refresh \longrightarrow read). Also, we present properties of the algorithm, such as its capability to detect stuck-at faults, transition faults, conventional pattern sensitive faults, and neighborhood bit-line sensitive faults.

  • PDF

Super Coupling Dual-gate Ion-Sensitive Field-Effect Transistors

  • Jang, Hyun-June;Cho, Won-Ju
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.239-239
    • /
    • 2013
  • For more than four decades, ion-sensitive field-effect transistor (ISFET) sensors that respond to the change of surface potential on a membrane have been intensively investigated in the chemical, environmental, and biological spheres, because of their potential, in particular their compatibility with CMOS manufacturing technology. Here, we demonstrate a new type of ISFET with dual-gate (DG) structure fabricated on ultra-thin body (UTB), which highly boosts sensitivity, as well as enhancing chemical stability. The classic ion-sensitive field-effect transistor (ISFET) has been confronted with chronic problems; the Nernstian response, and detection limit with in the Debye length. The super-coupling effects imposed on the ultra thin film serve to not only maximize sensitivity of the DG ISFET, but also to strongly suppress its leakage currents, leading to a better chemical stability. This geometry will allow the ISFET based biosensor platform to continue enhancement into the next decade.

  • PDF

Angle-sensitive Pixels Based on Subwavelength Compound Gratings

  • Meng, Yunlong;Hu, Xuemei;Yang, Cheng;Shen, Xinyu;Cao, Xueyun;Lin, Lankun;Yan, Feng;Yue, Tao
    • Current Optics and Photonics
    • /
    • 제6권4호
    • /
    • pp.359-366
    • /
    • 2022
  • In this paper, we present a new design for angle-sensitive pixels (ASPs). The proposed ASPs take advantage of subwavelength compound gratings to capture the light angle, which enables pixel size to reach the wavelength scale of 0.7 ㎛ × 0.7 ㎛. The subwavelength compound gratings are implemented by the wires of the readout circuit inherent to the standard complementary metal-oxide-semiconductor manufacturing process, thus avoiding additional off-chip optics or post-processing. This technique allows the use of two pixels for horizontal or vertical angle detection, and can determine the light's angle in the range from -45° to +45°. The proposed sensor enables surface-profile reconstruction of microscale samples using a lensless imaging system.

Nanosecond Gated Raman Spectroscopy for Standoff Detection of Hazardous Materials

  • Chung, Jin Hyuk;Cho, Soo Gyeong
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권12호
    • /
    • pp.3547-3552
    • /
    • 2014
  • Laser Raman spectroscopy is one of the most powerful technologies for standoff detection of hazardous materials including explosives. Supported by recent development of laser and sensitive ICCD camera, the technology can identify trace amount of unknown substances in a distance. Using this concept, we built a standoff detection system, in which nanosecond pulse laser and nanosecond gating ICCD technique were delicately devised to avoid the large background noise which suppressed weak Raman signals from the target sample. In standoff detection of explosives which have large kill radius, one of the most important technical issues is the detection distance from the target. Hence, we focused to increase the detection distance up to 54 m by careful optimization of optics and laser settings. The Raman spectra of hazardous materials observed at the distance of 54 m were fully identifiable. We succeeded to detect and identify eleven hazardous materials of liquid or solid particles, which were either explosives or chemical substances used frequently in chemical plants. We also performed experiments to establish the limit of detection (LOD) of HMX at 10 m, which was estimated to be 6 mg.

Statistics based localized damage detection using vibration response

  • Dorvash, Siavash;Pakzad, Shamim N.;LaCrosse, Elizabeth L.
    • Smart Structures and Systems
    • /
    • 제14권2호
    • /
    • pp.85-104
    • /
    • 2014
  • Damage detection is a challenging, complex, and at the same time very important research topic in civil engineering. Identifying the location and severity of damage in a structure, as well as the global effects of local damage on the performance of the structure are fundamental elements of damage detection algorithms. Local damage detection is essential for structural health monitoring since local damages can propagate and become detrimental to the functionality of the entire structure. Existing studies present several methods which utilize sensor data, and track global changes in the structure. The challenging issue for these methods is to be sensitive enough in identifYing local damage. Autoregressive models with exogenous terms (ARX) are a popular class of modeling approaches which are the basis for a large group of local damage detection algorithms. This study presents an algorithm, called Influence-based Damage Detection Algorithm (IDDA), which is developed for identification of local damage based on regression of the vibration responses. The formulation of the algorithm and the post-processing statistical framework is presented and its performance is validated through implementation on an experimental beam-column connection which is instrumented by dense-clustered wired and wireless sensor networks. While implementing the algorithm, two different sensor networks with different sensing qualities are utilized and the results are compared. Based on the comparison of the results, the effect of sensor noise on the performance of the proposed algorithm is observed and discussed in this paper.

Simple, Rapid and Sensitive Portable Molecular Diagnosis of SFTS Virus Using Reverse Transcriptional Loop-Mediated Isothermal Amplification (RT-LAMP)

  • Baek, Yun Hee;Cheon, Hyo-Soon;Park, Su-Jin;Lloren, Khristine Kaith S.;Ahn, Su Jeong;Jeong, Ju Hwan;Choi, Won-Suk;Yu, Min-Ah;Kwon, Hyeok-il;Kwon, Jin-Jung;Kim, Eun-Ha;Kim, Young-il;Antigua, Khristine Joy C.;Kim, Seok-Yong;Jeong, Hye Won;Choi, Young Ki;Song, Min-Suk
    • Journal of Microbiology and Biotechnology
    • /
    • 제28권11호
    • /
    • pp.1928-1936
    • /
    • 2018
  • Recently, human infections caused by severe fever with thrombocytopenia syndrome virus (SFTSV), which can lead to fatality, have dramatically increased in East Asia. With the unavailability of vaccines or antiviral drugs to prevent and/or treat SFTSV infection, early rapid diagnosis is critical for prevention and control of the disease. Here, we report the development of a simple, rapid and sensitive portable detection method for SFTSV infection applying reverse transcription-loop mediated isothermal amplification (RT-LAMP) combined with one-pot colorimetric visualization and electro-free reaction platform. This method utilizes a pocket warmer to facilitate diagnosis in a resource-limited setting. Specific primers were designed to target the highly-conserved region of L gene of SFTSV. The detection limit of the RT-LAMP assay was approximately $10^0$ viral genome copies from three different SFTSV strains. This assay exhibited comparable sensitivity to qRT-PCR and 10-fold more sensitivity than conventional RT-PCR, with a rapid detection time of 30 to 60 minutes. The RT-LAMP assay using SFTSV clinical specimens has demonstrated a similar detection rate to qRT-PCR and a higher detection rate compared to conventional RT-PCR. Moreover, there was no observed cross-reactive amplification of other human infectious viruses including Japanese Encephalitis Virus (JEV), Dengue, Enterovirus, Zika, Influenza and Middle East Respiratory Syndrome Coronavirus (MERS-CoV). This highly sensitive, electro- and equipment-free rapid colorimetric visualization method is feasible for resource-limited SFTSV field diagnosis.

Construction of High Sensitive Detection System for Endocrine Disruptors with Yeast n-Alkane-assimilating Yarrowia lipolytica

  • Cho, Eun-Min;Lee, Haeng-Seog;Eom, Chi-Yong;Ohta, Akinori
    • Journal of Microbiology and Biotechnology
    • /
    • 제20권11호
    • /
    • pp.1563-1570
    • /
    • 2010
  • To construct a highly sensitive detection system for endocrine disruptors (EDs), we have compared the activity of promoters with the n-alkane-inducible cytochrome P450 gene (ALK1), isocitrate lyase gene (ICL1), ribosomal protein S7 gene (RPS7), and the translation elongation factor-1${\alpha}$ gene (TEF1) for the heterologous gene in Yarrowia lipolytica. The promoters were introduced into the upstream of the lacZ or hERa reporter genes, respectively, and the activity was evaluated by ${\beta}$-galactosidase assay for lacZ and Western blot analysis for hER${\alpha}$. The expression analysis revealed that the ALK1 and ICL1 promoters were induced by n-decane and by EtOH, respectively. The constitutive promoter of RPS7 and TEF1 showed mostly a high level of expression in the presence of glucose and glycerol, respectively. In particular, the TEF1 promoter showed the highest ${\beta}$-galactosidase activity and a significant signal by Western blotting with the anti-estrogen receptor, compared with the other promoters. Moreover, the detection system was constructed with promoters linked to the upstream of the expression vector for the hER${\alpha}$ gene transformed into the Y. lipolytica with a chromosome-integrated lacZ reporter gene under the control of estrogen response elements (EREs). It was indicated that a combination of pTEF1p-hER${\alpha}$ and CXAU1-2XERE was the most effective system for the $E_2$-dependent induction of the ${\beta}$-galactosidase activity. This system showed the highest ${\beta}$-galactosidase activity at $10^{-6}\;M\;E_2$, and the activity could be detected at even the concentration of $10^{-10}\;M\;E_2$. As a result, we have constructed a strongly sensitive detection system with Y. lipolitica to evaluate recognized/suspected ED chemicals, such as natural/synthetic hormones, pesticides, and commercial chemicals. The results demonstrate the utility, sensitivity, and reproducibility of the system for identifying and characterizing environmental estrogens.