• Title/Summary/Keyword: self-inspection

Search Result 270, Processing Time 0.023 seconds

Design and Implement a Smart Automobile Self-Diagnosis System based on The Driving information (자동차 주행정보를 활용한 스마트 자동차 자가 점검 시스템 설계 및 구현)

  • Kim, Min-Young;Jang, Jong-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.9
    • /
    • pp.2153-2159
    • /
    • 2013
  • In order to drive a vehicle safely, driver needs to check status of the car. Many moderns are having trouble to spare time to visit auto mechanic and have car mechanics to check their car other than their office hours. If the car status cannot be inspected regularly, it is likely to cause a big accident threatening the surroundings as well as driver's life. Inspection tool and system help driver to check their own vehicle status personally are required for preventing it. In this paper, it designed and realized system that records driving information based on changing data of vehicle (location and automotive internal data) and allows driver can check the vehicle status easily and further, driver can share the driving information with repair shop via the Internet to receive detailed inspection service for car status.

A Study on Safety Inspection Model for Small Scale Construction Field (중.소규모 건설현장 안전점검 모질 연구)

  • 안병수;양광모;강경식
    • Journal of the Korea Safety Management & Science
    • /
    • v.3 no.3
    • /
    • pp.11-21
    • /
    • 2001
  • Domestic construction industry has considerable level of construction performance and technology thanks to the economic development and as the result of performing diverse oversea construction project. However, construction disasters have been steadily increasing, and do severe disasters at faster pace. Most of such disasters happen at small and small medium-sized construction fields, which contract size is less than 10 billion won. small and medium-sized construction fields are not obliged to designate a safety manager, and have limitations in engaging self-regulating disaster prevention activities due to reduced budget for safety facilities. For the small and medium-sized construction sites with less than 10 billion won, the Ministry of Labor has been carrying out mobile inspections of construction safety. However, the effect so far is insignificant and an improvement plan is required. Therefore, in the present thesis, we derive problems appearing in the current construction safety mobile inspection system, investigate and study systems in foreign countries, and suggest an efficient and effective plan to operate safety technology inspections. First of all, we establish a standard to select sites to be inspected that are high in construction risk and disaster occurrence probability In addition, we suggest a plan to take administrative and judiciary measures based on the total score for disaster factors considering the disaster occurrence probability and the illegal practices. Furthermore, a scheme to maximize the effect of disaster prevention is sought by building an organic cooperative system between the Ministry of Labor, Korea Occupational Safety & Health Agency and other organizations specialized in instruction of construction disaster prevention. Finally, we induce a research conclusion that leads to self-regulating safety management through checking and instructing systematic management on mobile inspections.

  • PDF

Study on the Effectiveness of image inspection Replacement of the Periodontal disease Questionnaire in the Electronic Medical Record Environment (전자의무기록 의료 환경에서 치주 자가설문지의 영상 판독 대체 효용성에 대한 연구)

  • Maeng, You-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.4
    • /
    • pp.707-714
    • /
    • 2017
  • There have recently been an increasing number of reports claiming that the periodontal disease, the most typical oral disease, is closely associated with various systemic diseases such as cardiovascular disease. Therefore, it is imperative to explore the methods that can ensure effective and cost-effective monitoring of periodontal disease in specific population groups, as well as individuals in the electronic medical record environment. However, traditional periodontal examination methods, such as periodontal probe, are considerably demanding and time-consuming for dental specialists, and furthermore, cause the risk of bacteremia as they are invasive procedures. Thus, the objective of this study was to validate the capability of new method for screening the periodontal disease using the self-reported questionnaire for periodontitis which is the non-invasive procedure to replace radiography.

The Status of Maintenance of Exhaust Fans and Bag filters in Melting Processes in a foundry industrial complex (주물 공단 용해공정의 송풍기 및 백필터 관리 실태)

  • Kim, Tae Hyeung;Ha, Hyun Chul;Jeoung, Chun Hwa;Seo, Jeoung Yoon;Piao, Cheng Xu;Yang, Jun Ho;Li, Xiaoyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.3
    • /
    • pp.212-223
    • /
    • 2007
  • 18 Local exhaust ventilation systems in 10 melting companies located in an industrial complex were tested to know the status of maintenance. Test items were fan flowrates, fan static pressures, rotational speeds and differential pressures of bag filters. Only 22% of the tested fans has more than 80% flowrate efficiency. 44% of the fans has lower than 60% efficiency. The performance of the fans are not in a good status. For the fans with lower than 60% efficiency, the analysis shows that the lower flowrate might be caused by the degradation of fan performance. On the other hand, for the fan s with higher than 60% efficiency, the main cause of flowrate reduction might be too much pressure losses due to clogging of filter bags. The degradation of fans usually lead the reduction of hood capture efficiency, resulting in the increase of contaminant concentrations in workplace. To keep fans in good status, self inspections should be periodically conducted. This inspection should include the measurements of flowrate and pressures. The most important thing to be performed is the initial test of local exhaust ventilation system because the initial test data should be used to know the level of system degradation.

Shear Performance Analysis of One-way Hollow Slab According to Shear Reinforcement (전단 보강 유무에 따른 일방향 중공슬래브의 전단 성능 분석)

  • Yoon, Sung-Wook;Seok, Keun-Young;Kim, Gee-Cheol;Kang, Joo-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.97-104
    • /
    • 2014
  • Hollow slab is a floor system which reduces the load of vertical structural members and earthquake load by decreasing self-weight of slab. Although hollow slab can reduce self-weight of slab remarkably, flexural strength and shear strength reduce due to the hollow section inside the slab, so it is very important to predict structural behavior. In spite of plenty of domestic and foreign studies on hollow slab, there is a shortage of research on shear performance according to shear reinforcement of one-way hollow slab. Therefore, this study aims to verify the need for shear reinforcement of one-way hollow slab by analyzing failure modes of one-way hollow slab depending on the state of shear reinforcement and comparing shear strengths of estimation formula and experimental value with one another.

Behavior of Soft Ground Throughout Mock-up Test Using Low Self Weight Banking Method (경량성토 모형시험을 통한 연약지반상의 성토제체의 거동)

  • Kim, Sang Chel
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.85-91
    • /
    • 2011
  • This study aims at evaluating feasibility of Bottom ash-mixed Foam Cement Banking(BFCB) Method on the enhancement of soft soil, which is developed to reduce self-weight of banking by applying bottom ash and foam. to cement slurry. In order to measure the behavior of soil when BFCB layer was covered to soft ground, a testing equipment for mock-up test was fabricated and phased loads were applied up to measurement of yielding and ultimate strengths as well as movement of ground particles. In addition, these measured values such as settlement and heaving were compared with ones of surface-hardening method prevailing on soil improvement. As the result through mock-up test, BFCB showed lower values of ground deformation, while wider range of deformation was observed in compare to the other method. And settlement and heaving were measured lower, which implies the method developed is very effective to applicability of soft ground.

Evaluation on the Vibration Performance for Void-deck Slab Combined with Deck Plate and Polystyrene Void Foam (데크플레이트와 경량성형재가 결합된 중공슬래브의 진동성능에 대한 실물실험 평가)

  • Cho, Seung-Ho;Roh, Young-Sook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.3
    • /
    • pp.86-92
    • /
    • 2017
  • The possibility to development of floor vibration problem is larger in case of long span structure under service loads. Therefore, to improve the vibration performance of the floor, increasing of its thickness is a common method. But, increasing of thickness can lead to increase of slab self weight and reduce the effectiveness of the building. For this reason, attention for voided slab which reduces the self-weight is increasing. Hence, voided deck slab combined with deck plate and polystyrene void foam which has buoyancy prevention capacity and much developed construct ability has bee developed. By using the developed voided slab, vibration performance of a mock-up building structure has been investigated in the current study. The results according to analysis showed that they can be implemented in living and bedroom which are considered as 1st grade on the basis of "Residential Evaluation Guidelines for Vibration of Buildings" by the Architectural Institute of Japan.

A Study on the Improvement of Evaluation Indicators for Small Library Operations (작은도서관 운영평가 지표 개선에 관한 연구)

  • Kim, Bo-il
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.52 no.1
    • /
    • pp.5-34
    • /
    • 2018
  • The small library evaluation index, which was previously developed and is currently in use, needs to be improved because of two major reasons: inefficient allocation of points along with evaluation items and detailed indicators that are different from the actual environment of small libraries; and the lack of value as basic data for preparing policies relevant to small libraries. Therefore, the present study proposed a small library operation evaluation index (draft) that includes not only a quantitative evaluation but also a qualitative evaluation that allows the evaluation of the basic purpose and value of small libraries by reflecting the demands of the small libraries that are being evaluated. The proposed small library operation evaluation index (draft) was made to be an evaluation for self-inspection that enables small libraries to autonomously conduct operation evaluation and gauge their level by diversifying the evaluation methods and the evaluation scale of detailed indicators.

The Study on the Improvement Policy of the Pre and Post Regulation System of Radio Station (무선국 관리 사전규제 개선과 사후관리 효율화 방안에 대한 연구)

  • Kim, Ho-Yeong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.745-758
    • /
    • 2022
  • As the unlimited natural source of a country, radio waves are widely being used in the daily life toward knowledge based information society. Therefore it is necessary to provide a long term policy of radio waves management policies based on market situation to cope with rapidly changing wireless technology and effective use of radio resources. Literary survey and analysis were accomplished for the rules and regulations in the radio station approval system and post-approval policies for mobile communication service. In conclusion, this study propose an blanket radio approval policy as well as self declaration of conformity(SDoC) of radio waves technical regulation and advanced radio inspection procedure. This study has significance in providing reference for introducing deregulation policy in the radio communication imdustry.

Evaluation of Hydrophobic Performance and Durability of Concrete Coated with Cellulose Nanofiber Mixed Antifouling Coating Agent (셀룰로오스 나노섬유 혼합 방오코팅제가 도포된 콘크리트의 소수성능과 내구성능 평가)

  • Nak Sup Jang;Chi Hoon Nho;Hongseob Oh
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.1-8
    • /
    • 2023
  • Marine and hydraulic structures are subject to durability damage not only due to the penetration of sea water but also due to the attachment of marine organisms. Therefore, in this study, we tried to develop an antifouling coating agent with self-cleaning function for marine concrete. It was confirmed that the antifouling coating agent mixed with AKD, cellulose nanofibers and BADGE had sufficient antifouling performance at a well hydrophobicity of around 140° in contact angle and an inclination angle of 15°. In the abrasion resistance test of the surface, only a maximum loss of 0.015 g occurred. In the durability test, as a result of the chloride ion permeation test, almost no chloride ion permeation occurred in the variable where the coating agent was applied, and carbonation and freeze-thaw damage also rarely occurred, so it was analyzed that it was effective in securing durability of concrete.