• Title/Summary/Keyword: selenium(Se)

Search Result 379, Processing Time 0.026 seconds

A Study for the Relation Between Selenoproteins and Korean Rectal Cancer Using Deuterium Collision Gas HPLC-ICP/MS (HPLC와 중수소 충돌기체 ICP/MS를 이용하여 분석한 셀레노단백질과 한국인 직장암과의 상관관계 연구)

  • Lee, Seo Young;Pak, Yong-Nam
    • Journal of the Korean Chemical Society
    • /
    • v.63 no.6
    • /
    • pp.420-426
    • /
    • 2019
  • Selenoproteins,in Korean blood serum, GPx, SelP, and SeAlb were separated and determined with the use of HPLC-ICP/MS. Deuterium was used as a collision gas and affinity column with ammonium formate was used as an eluting solvent for the accurate quantitation of selenoproteins in human blood serum. Certified reference material BCR 639 (133±12 ng g-1) was tested for the accuracy and the result was satisfactory 130±6 ng g-1. Blood serum for the rectal cancer and controlled groups were collected and analyzed to give 84±27 ng g-1, and 119±28 ng g-1, respectively. The difference was statistically obvious when t-test was performed (tcal 4.93 > t95% 2.04). The decrease for cancer group was more obvious for female and aged group. The distributions of three selenoproteins were similar with each other, which means rectal cancer group did not show any specificity for any selenoproteins. As cancer developed, GPx showed a slight decrease but not obvious while the total concentration was increasing particularly at the second stage of cancer.

Absorption and Distribution for Subtoxic Level of Selenite by Vascularly Perfused Small Intestine in Rats (랫드의 소장-혈관의 이중 관류를 통한 저독성 농도의 selenite 흡수와 분포)

  • Park, Yeong-Chul;Yoon, Mi-Sook;Kim, Jong-Bong
    • Journal of Life Science
    • /
    • v.20 no.2
    • /
    • pp.169-175
    • /
    • 2010
  • Intestinally absorptive and distributive aspects of the subtoxic level of selenite in rats were investigated using a double perfusion system. The double-perfusion technique is an in situ, in vitro preparation in which the intestinal lumen and its vasculature are perfused simultaneously. In the previous study, the subtoxic level of sodium selenite was determined to be 1.2 mM through inhibition of 3-0-methyl glucose (3MG) absorption. Thus, the selenite used to identify the intestinally absorptive mechanism of selenite was perfused at a luminal concentration of 1, 10, 50, 100 and $200\;{\mu}M$. Appearance of radiolabeled-Selenium (Se) was identified in three compartments: luminal perfusate, small intestine and vascular perfusate. Dose-response curves for Se in the three compartments indicate that selenite is absorbed by non-mediated passive diffusion. Regarding the distributive aspect, $21.02{\pm}3.92%$ of the total amount of selenite in the lumen was transported into the blood vessels across the small intestine. However, $4.75{\pm}1.75%$ of the total amount of selenite in the lumen is retained by the small intestine. Therefore, a total of $25.67{\pm}4.46%$ of the test dose was taken up from the luminal perfusate.

Characterization and deposition of Cu2ZnSnS4 film for thin solar cells via sol-gel method (Sol-gel법에 의한 박막태양전지용 Cu2ZnSnS4 박막의 증착과 특성)

  • Kim, Gwan-Tae;Lee, Sang-Hyun;Park, Byung-Ok
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.3
    • /
    • pp.127-133
    • /
    • 2012
  • To achieve low-cost and high-efficiency of thin-film solar cells applications, the sol-gel method that can be coated on a large area substrate, obtain homogeneous thin films of high purity was used. We studied structural and optical characteristics versus annealing temperature of $Cu_2ZnSnS_4$ which has kesterite structure by substitution low-cost sulfur (S) instead of high-cost selenium (Se). By analyzing XRD patterns, main peak was observed at $2{\theta}=28.5^{\circ}$ when Zn/Sn ratio is 0.8/1.2. And when we observed kesterite structure which has orientation of (112) direction, the more annealing temperature increase the bigger strength of (112) direction is. $Cu_2ZnSnS_4$ thin film showed characteristics of kesterite structure at $550^{\circ}C$. And when we calculated lattice constant, a = 5.5047 and $c=11.014{\AA}$ as same JCPDS (Joint Committee on Powder Standards) data measured. We measured optical transmittance to analyze optical characteristics. Optical transmittance was lower than 65 % at visible ray (${\lambda}=380{\sim}770nm$).

A Study on Bismuth tri-iodide for X-ray direct and digital imagers (직접방식 엑스선 검출기를 위한 $BiI_3$ 특성 연구)

  • Lee, S.H.;Kim, Y.S.;Kim, Y.B.;Jung, S.H.;Park, J.K.;Jung, W.B.;Jang, M.Y.;Mun, C.W.;Nam, S.H.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.27-31
    • /
    • 2009
  • Now a days, the Medical X-ray equipments has become digitalized from analog type such as film, cassette to CR, DR. And many scientists are still researching and developing the Medical X-ray equipment. In this study, we used the Bismuth tri-iodide to conversion material for digital X-ray equipments and we couldn't get the satisfying result than previous study, but it opened new possibility to cover the disadvantage of a-Se is high voltage aplly and difficultness of make. In this paper, we use $BiI_3$ powder(99.99%) as x-ray conversion material and make films that have thickness of 200um and the film size is $3cm{\times}3cm$. Also, we deposited an ITO(Indium Tin Oxide) electrode as top electrode and bottom electrode using a Magnetron Sputtering System. To evaluate a characteristics of the produced films, an electrical and structural properties are performed. Through a SEM analysis, we confirmed a surface and component part. And to analyze the electrical properties, darkcurrent, sensitivity and SNR(Signal to Noise Ratio) are measured. Darkcurrent is $1.6nA/cm^2$ and sensitivity is $0.629nC/cm^2$ and this study shows that the electrical properties of x-ray conversion material that made by screen printing method are similar to PVD method or better than that. This results suggest that $BiI_3$ is suitable for a replacement of a-Se because of the reduced manufacture processing and improved yield.

  • PDF

Study of Trace Element and PAHs Distribution for Extensive Regulation Establishment in Raw Material of Compost on Organic Resource (퇴비원료기준 확대설정을 위한 유기성자원의 미량원소 및 PAHs 분포 연구)

  • Lim, Dong-Kyu;Lee, Seung-Hwan;Kwon, Soon Ik;Seong, Ki-Seog;Lee, Jeong-Taek;Song, Beom-Heon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.6
    • /
    • pp.339-344
    • /
    • 2006
  • A lot of organic wastes have been produced from diverse industries, they must be tested by the regulation of fertilizer control act if reuse the organic wastes for agricultural utilization. The regulation has had only two criteria; the content of organic matter and 8 heavy metals. This study was conducted to evaluation trace element (boron, cobalt, molybdenum, and selenium) and distribution of organic compounds with different classification for complement the regulation in 16 organic waste materials(62 samples) collected from different regions and industries. Contents of boron(leather industry sludge, $154.2mg\;kg^{-1}$; food company sludge, $57.1mg\;kg^{-1}$), cobalt(industrial area sewage sludge, $95.2mg\;kg^{-1}$; metropolitan sewage sludge, $22.9mg\;kg^{-1}$), molybdenum(metropolitan sewage sludge, $40.1mg\;kg^{-1}$; food company sludge, $16.8mg\;kg^{-1}$), selenium (fiber industry sludge, $28.1mg\;kg^{-1}$; leather industry sludge, $16.9mg\;kg^{-1}$; food company sludge, $15.9mg\;kg^{-1}$) were highest compare to the other organic wastes. Total PAHs contents were the highest in paper-mill manufacture($3,462ug\;kg^{-1}$), and among the 16 PAHs, naphthalene, phenanthrene, pyrene, fluoroanthene, Anthracene and acenaphthene were detected more clearly than others in all kinds of organic resources.

Image Quality Evaluation of Medical Image Enhancement Parameters in the Digital Radiography System (디지털 방사선시스템에서 영상증강 파라미터의 영상특성 평가)

  • Kim, Chang-Soo;Kang, Se-Sik;Ko, Seong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.329-335
    • /
    • 2010
  • Digital imaging detectors can use a variety of detection materials to convert X-ray radiation either to light or directly to electron charge. Many detectors such as amorphous silicon flat panels, CCDs, and CMOS photodiode arrays incorporate a scintillator screen to convert x-ray to light. The digital radiography systems based on semiconductor detectors, commonly referred to as flat panel detectors, are gaining popularity in the clinical & hospital. The X-ray detectors are described between a-Silicon based indirect type and a-Selenium based direct type. The DRS of detectors is used to convert the x-ray to electron hole pairs. Image processing is described by specific image features: Latitude compression, Contrast enhancement, Edge enhancement, Look up table, Noise suppression. The image features are tuned independently. The final enhancement result is a combination of all image features. The parameters are altered by using specific image features in the different several hospitals. The image in a radiological report consists of two image evaluation processes: Clinical image parameters and MTF is a descriptor of the spatial resolution of a digital imaging system. We used the edge test phantom and exposure procedure described in the IEC 61267 to obtain an edge spread function from which the MTF is calculated. We can compare image in the processing parameters to change between original and processed image data. The angle of the edge with respect to the axes of detector was varied in order to determine the MTF as a function of direction. Each MTF is integrated within the spatial resolution interval of 1.35-11.70 cycles/mm at the 50% MTF point. Each image enhancement parameters consists of edge, frequency, contrast, LUT, noise, sensitometry curve, threshold level, windows. The digital device is also shown to have good uniformity of MTF and image parameters across its modality. The measurements reported here represent a comprehensive evaluation of digital radiography system designed for use in the DRS. The results indicate that the parameter enables very good image quality in the digital radiography. Of course, the quality of image from a parameter is determined by other digital devices in addition to the proper clinical image.

Studies on the Nutritional Components of Mugwort, Artemisia mongolica Fischer (참쑥의 영양성분에 관한 연구)

  • Sim, Young-Ja;Han, Yeong-Sil;Chun, Hui-Jung
    • Korean Journal of Food Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.49-53
    • /
    • 1992
  • This study was attempted to analyze amino acids, fatty acids, vitamins and minerals, reducing sugars and dietary fiber of Artemisia mongolica Fischer to establish the value as an useful vegetable. Total free amino acids of mugworts plucked in spring and autumn were 1048.1 mg% and 2187.1 mg% respectively. The contents of linoleic and linolenic acids were 76.7% in spring mugworts and 69.5% in autumn ones. Mugworts gathered in spring and autumn showed 0.16 mg% and 0.15 mg% for thiamin, 1.81 mg% and 1.74 mg% for riboflavin, 5.34 mg% and 5.36 mg% for niacin and 26.12 mg% and 25.21 mg% for ascorbic acid. Mineral contents of spring and autumn mugworts were 17.8 mg% and 20.5 mg% for iron, 0.3 ppm and 0.4 ppm for selenium. The contents of reducing sugar were fructose 9.75 mg% for spring, 9.78 mg% for autumn and the contents of dietary fiber were 37.57% for spring and 38.41% for autumn.

  • PDF

Development of 9th Revision Korean Food Composition Table and Its Major Changes (국가표준식품성분표 제9개정판의 구축 과정 및 주요 특징)

  • Park, Su-Hui;Kim, Se-Na;Lee, Sang Hoon;Choe, Jeong-Sook;Choi, Youngmin
    • Korean Journal of Community Nutrition
    • /
    • v.23 no.4
    • /
    • pp.352-365
    • /
    • 2018
  • Objectives: The Korean Food Composition Table (KFCT) was first published in 1970, and has since been updated every five years by the Rural Development Administration (RDA). This study was conducted to introduce the development strategies, features, and challenges of the $9^{th}$ revision of the KFCT. Methods: Due to the increasing demands of nutrient database users and generators, the RDA started a new research project in 2013 to improve the quantity and quality of data for the $9^{th}$ revision of the KFCT. Over 1,000 food items frequently consumed in Korea were selected as key foods using the results of the Korean National Health and Nutrition Examination Survey. About 200 raw materials and processed food items were collected and analyzed every year. Target nutrients that were analyzed by collaborative labs, such as, sugars, selenium, iodine, and biotin, were increased from 22 to 43. Analytical sample handling procedures and data quality evaluation systems were also established in collaboration with 10 contracted labs. Data were evaluated for data quality according to the FAO/INFOODS, CODEX, and AOAC guidelines. Results: The $9^{th}$ revision contains data on 3,000 food items and up to 43 and 140 food nutrients for the printed table and the excel database file, respectively. Overall, 1,485 data items were newly added, 973 of which were provided by the RDA and 512 were cited from foreign nutrient databases. The remaining 1,515 food items were maintained as in the $8^{th}$ revision. Conclusions: The KFCT provides the basic infrastructure for food and nutrition policy, research, and dietary practice in South Korea. The use of the KFCT has increased exponentially in the past few years in both public and private sectors; accordingly, increased efforts should be paid to the preparation, improvement, and maintenance of KFCT.

Comparison of Electrical Signal Properties about Top Electrode Size on Photoconductor Film (광도전체 필름 상부 전극크기에 따른 전기적 신호 특성 비교)

  • Kang, Sang-Sik;Jung, Bong-Jae;Noh, Si-Cheul;Cho, Chang-Hoon;Yoon, Ju-Sun;Jeon, Sung-Pyo;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.93-96
    • /
    • 2011
  • Currently, the development of direct conversion radiation detector using photoconductor materials is progressing in widely. Among of theses photoconductor materials, mercuric iodide compound than amorphous selenium has excellent absorption and sensitivity of high energy radiation. Also, the detection efficiency of signal generated in photoconductor film varies by electric filed and geometric distribution according to top-bottom electrode size. Therefore, in this work, the x-ray detection characteristics are investigated about the size of top electrode in $HgI_2$ photoconductor film. For sample fabrication, to solve the problem that is difficult to make a large area film, we used the spatial paste screen-print method. And the sample thickness is $150{\mu}m$ and an film area size is $3cm{\times}3cm$ on ITO-coated glass substrate. ITO(Indium-Tin-Oxide) electrode was used as top electrode using a magnetron sputtering system and each area is $3cm{\times}3cm$, $2cm{\times}2cm$ and $1cm{\times}1cm$. From experimental measurement, the dark current, sensitivity and SNR of the $HgI_2$ film are obtained from I-V test. From the experimental results, it shows that the sensitivity increases in accordance with the area of the electrode but the SNR is decreased because of the high dark current. Therefore, the optimized size of electrode is importance for the development of photoconductor based x-ray imaging detector.