• 제목/요약/키워드: selective detection

검색결과 576건 처리시간 0.028초

Adaptive Selective Compressive Sensing based Signal Acquisition Oriented toward Strong Signal Noise Scene

  • Wen, Fangqing;Zhang, Gong;Ben, De
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권9호
    • /
    • pp.3559-3571
    • /
    • 2015
  • This paper addresses the problem of signal acquisition with a sparse representation in a given orthonormal basis using fewer noisy measurements. The authors formulate the problem statement for randomly measuring with strong signal noise. The impact of white Gaussian signals noise on the recovery performance is analyzed to provide a theoretical basis for the reasonable design of the measurement matrix. With the idea that the measurement matrix can be adapted for noise suppression in the adaptive CS system, an adapted selective compressive sensing (ASCS) scheme is proposed whose measurement matrix can be updated according to the noise information fed back by the processing center. In terms of objective recovery quality, failure rate and mean-square error (MSE), a comparison is made with some nonadaptive methods and existing CS measurement approaches. Extensive numerical experiments show that the proposed scheme has better noise suppression performance and improves the support recovery of sparse signal. The proposed scheme should have a great potential and bright prospect of broadband signals such as biological signal measurement and radar signal detection.

Gas chromatograph-mass selective detector를 이용한 식육 중 잔류농약의 동시분석 (Simultaneous detection method for pesticide residues in meat by gas chromatograph-mass selective detector)

  • 홍인석;최윤화;권택부;이정학
    • 한국동물위생학회지
    • /
    • 제28권3호
    • /
    • pp.285-294
    • /
    • 2005
  • This study was conducted to investigate the extraction method for the determination of organochlorine, organophosphorus and synthetic pyrethroid pesticide residues in beef fat by gas chromatography-mass selective detector(GC-MSD). Twenty one pesticide residues in fat were determined using a simple and rapid procedure based on solid- phase extraction(SPE) clean-up cartridges with octadecyl $(C_{18})-bonded$ porous silica, florisil, $10\%$ deactivated florisil. a tandem $C_{18}$ and florisil and a tandem $C_{18}$ and $10\%$ deactivated florisil. Solvent-solvent extraction using acetonitrile was not satisfied to eliminate fat interference for pesticide residue analysis by GC-MSD, and the recoveries of the method in fat ranged from 16.2 to $57.3\%$ except DDT$(83.2\%)$. The recoveries of SPE methods using a tandem $C_{18}$ and Florisil was $59.6\~123.8\%$ except fenitrothion $(135.2\%)$. the SPE method was verified the satisfactory performance of pre-treatment for pesticide residues analysis in fat by GC-MSD. The efficiency of florisil deactivated with $10\%$ water has been not proved significantly on recoveries of pesticide residues in fat.

Manganese(II) Ion-Selective Membrane Electrode Based on N-(2-picolinamido ethyl)-Picolinamide as Neutral Carrier

  • Aghaie, M.;Giahi, M.;Zawari, M.
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권10호
    • /
    • pp.2980-2984
    • /
    • 2010
  • A new poly (vinyl chloride) (PVC) membrane electrode that is highly selective to $Mn^{+2}$ ions was prepared using N,N'-bis(2'-pyridinecarboxamide)-1,2-ethane ($bpenH_2$) as a suitable neutral carrier. This concentration range ($1.0{\times}10^{-5}$ to $1.0{\times}10^{-1}\;M$) with Nernstian slope of $29.3{\pm}0.5\;mV$ per decade. The detection limit and the response time of electrode were $8.0{\times}10^{-6}\;M$ and (${\leq}15\;s$) respectively. The membrane can be used for more than two months without observing any divergence. The electrodes exhibited excellent selectivity for $Mn^{+2}$ ion over other mono-, di- and trivalent cations. Selectivity coefficients were determined by the matched potential method (MPM). The electrode can be used in the pH range from 4.0 - 9.0. The isothermal coefficient of this electrode amounted to 0.00023 V/$^{\circ}C$. The stability constant (log $K_s$) of the $Mn^{+2}$ - $bpenH_2$ complex was determined at $25^{\circ}C$ by potentiometric titration in mixed aqueous solution. The proposed electrode was applied to the determination of $Mn^{+2}$ ions in real samples.

Lead(II)-selective Polymeric Electrode Using a Schiff Base Complex of N,N'-Bis-thiophene-2-ylmethylene-ethane-1,2-diamine as an Ion Carrier

  • Jeong, Tae-Jun;Jeong, Dae-Cheol;Lee, Hyo-Kyoung;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권8호
    • /
    • pp.1219-1224
    • /
    • 2005
  • We prepared lead ion-selective PVC membranes that were based on N,N'-bis-thiophene-2-ylmethylene-ethane-1,2-diamine as a membrane carrier. The membrane electrode has a linear dynamic range between 1.0 ${\times}$ $10^{-5}$ and 1.0 ${\times}$ $10^{-1}$ M with a Nernstian slope of 29.79 mV per decade, and its detection limit was 2.04 ${\times}$ $10^{-6}$ M at room temperature. The potentiometric response is independent of the pH of the solution in the pH range of 5-7. The proposed electrode revealed good selectivity and response for $Pb^{2+}$ over a wide variety of other metal ions in pH 5.0 buffer solutions, and there was good reproducibility of the base line on the subsequent measurements. The membrane electrode has a relatively fast response time, satisfactory reproducibility and a relatively long life time.

Development of a New Copper(II) Ion-selective Poly(vinyl chloride) Membrane Electrode Based on 2-Mercaptobenzoxazole

  • Akhond, Morteza;Ghaedi, Mehrorang;Tashkhourian, Javad
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권6호
    • /
    • pp.882-886
    • /
    • 2005
  • Copper(II) ion-selective PVC membrane electrode based on 2-mercaptobenzoxazole as a new ionophore and o-nitrophenyl octyl ether (o-NPOE) as plasticizer is proposed. This electrode revealed good selectivity for $Cu^{2+}$ over a wide variety of other metal ions. Effects of experimental parameters such as membrane composition, nature and amount of plasticizer, and concentration of internal solution on the potential response of $Cu^{2+}$ sensor were investigated. The electrode exhibits good response for $Cu^{2+}$ in a wide linear range of 5.0 ${\times}$ 10−.6-1.6 ${\times}$ $10^{-2}$ mol/L with a slope of 29.2 ${\pm}$ 2.0 mV/decade. The response time of the sensor is less than 10 s, and the detection limit is 2.0 ${\times}$ $10^{-6}$ mol/L. The electrode response was stable in pH range of 4-6. The lifetime of the electrode was about 2 months. The electrode revealed comparatively good selectivities with respect to many alkali, alkaline earth, and transition metal ions.

Improved Thiocyanate-Selective Electrode Based on Tetra(trimethylphenyl)-porphyrinato Manganese(III) Chloride: The Electronic and pH Effects

  • Seo, Hyung-Ran;Lee, Hyo-Kyoung;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권10호
    • /
    • pp.1484-1488
    • /
    • 2004
  • The thiocyanate-selective PVC membrane electrodes based on 5,10,15,20-tetrakis(2,4,6-trimethylphenyl)-porphyrinatomanganese(III) chloride [Mn(TMP)Cl] and 5,10,15,20-tetrakis(2,6-dichlorophenyl)porphyrinatomanganese(III) chloride $[Mn(Cl_8TPP)Cl]$ as ion carriers were investigated. The effect of ionophores, membrane compositions, plasticizers, and solution pHs on the response characteristics were studied. The Mn(TMP)Cl as an ionophore shows the best potentiometric sensitivity with a slope of -58.7 mV/decade and a detection limit of $log[SCN^-]$ = -6.90, and selectivity for thiocyanate over strong hydrophobic interfering anions such as ${ClO_4}^-$ and salicylate. The potentiometric response is affected by the electronic effect of the substituents and solution pHs. The presence of substituents with electron donating and more liphophilic characters around the ligated metal center produces an improved response toward $SCN^-$.

Synthesis of a New Hexadendates Schiff's Base and Its Application in the Fabrication of a Highly Selective Mercury(II) Sensor

  • Ganjali, M.R.;Norouzi, P.;Alizadeh, T.;Salavati-Niasari, M.
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권1호
    • /
    • pp.68-72
    • /
    • 2007
  • A new PVC membrane potentiometric sensor that is highly selective to Hg2+ ions was prepared, using bis(2-hydroxybenzophenone) butane-2,3-dihydrazone (HBBD) as an excellent hexadendates neutral carrier. The sensor works satisfactorily in the concentration range of 1.0 × 10-6 to 1.0 × 10-1 mol L-1 (detection limit 4 × 10-7 mol L-1) with a Nernstian slope of 29.7 mV per decade. This electrode showed a fast response time (~8 s) and was used for at least 12 weeks without any divergence. The sensor exhibits good Hg2+ selectivity for a broad range of common alkali, alkaline earth, transition and heavy metal ions (lithium, sodium, potassium, magnesium, calcium, copper, nickel, cobalt, zinc, cadmium, lead and lanthanum). The electrode response is pH independent in the range of 1.5-4.0. Furthermore, the developed sensor was successfully used as an indicator electrode in the potentiometric titration of mercury ions with potassium iodide and the direct determination of mercury in some binary and ternary mixtures.

Comparative Study of Holmium (III) Selective Sensors Based on Thiacalixarene and Calixarene Derivatives as an Ionophore

  • Singh, Sanjay;Rani, Geeta
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권7호
    • /
    • pp.2229-2237
    • /
    • 2012
  • The two chelates based on calix[4]arene and thiacalix[4]arene have been synthesized and used as neutral ionophores for preparing PVC based membrane sensor selective to $Ho^{3+}$ ion. The addition of potassium tetrakis(4-chlorophenyl)borate (KTpClPB) and various plasticizers, viz., NDPE, o-NPOE, DOP, TEP and DOS have been found to improve significantly the performance of the sensors. The best performance was obtained with the sensor no. 6 having membrane of $L_2$ with composition (w/w) ionophore (2%): KTpClPB (4%): PVC (37%): NDPE (57%). This sensor exhibits Nernatian response with slope $21.10{\pm}0.3mV/decade$ of activity in the concentration range $3.0{\times}10^{-8}-1.0{\times}10^{-2}M\;Ho^{3+}\;ion$, with a detection limit of $1.0{\times}10^{-8}M$. The proposed sensor performs satisfactorily over a wide pH range of 2.8-10, with a fast response time (5 s). The sensor was also found to work successfully in partially non-aqueous media up to 25% (v/v) content of methanol, ethanol and acetonitrile, and can be used for a period of 4 months without any significant drift in potential. The electrode was also used for the determination of $Ho^{3+}$ ions in synthetic mixtures of different ions and the determination of the arsenate ion in different water samples.

머신러닝을 이용한 에너지 선택적 유방촬영의 진단 정확도 향상에 관한 연구 (A Feasibility Study on the Improvement of Diagnostic Accuracy for Energy-selective Digital Mammography using Machine Learning)

  • 엄지수;이승완;김번영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권1호
    • /
    • pp.9-17
    • /
    • 2019
  • Although digital mammography is a representative method for breast cancer detection. It has a limitation in detecting and classifying breast tumor due to superimposed structures. Machine learning, which is a part of artificial intelligence fields, is a method for analysing a large amount of data using complex algorithms, recognizing patterns and making prediction. In this study, we proposed a technique to improve the diagnostic accuracy of energy-selective mammography by training data using the machine learning algorithm and using dual-energy measurements. A dual-energy images obtained from a photon-counting detector were used for the input data of machine learning algorithms, and we analyzed the accuracy of predicted tumor thickness for verifying the machine learning algorithms. The results showed that the classification accuracy of tumor thickness was above 95% and was improved with an increase of imput data. Therefore, we expect that the diagnostic accuracy of energy-selective mammography can be improved by using machine learning.

선택적 감쇄환경에서 분산안테나 간 주파수 오차 환경에 강인한 알라무티부호화 직교주파수분할다중방식 기반 간섭 제거기법 (Multiple Frequency Offsets Cancellation Scheme Based on Alamouti Coded OFDM for Distributed Antenna Systems in Selective Fading Channel)

  • 김봉석;최권휴
    • 한국통신학회논문지
    • /
    • 제38A권12호
    • /
    • pp.1039-1044
    • /
    • 2013
  • 선택적 감쇄채널 환경에서 분산안테나 간 주파수 오차에 의한 부반송파 간 간섭을 효율적으로 제거하는 알라무티부호화 직교주파수분할다중방식(Alamouti coded OFDM) 기반 간섭제거 기법을 제안한다. 일반적으로 간섭제거 방식에서는 초기검출 심볼로부터 간섭신호를 추정하고 추정한 간섭신호를 원래 수신 신호에서 제거함으로써 성능을 개선시킨다. 이때 초기 검출 심볼의 정확도가 높을수록 제거되는 부반송파간 간섭량 또한 증가하므로 간섭제거 방식에서 초기 검출심볼의 정확도는 매우 중요하다. 제안하는 방식은 초기 검출심볼을 얻는 과정에서 주파수 오차에 의한 부반송파간 간섭의 일부를 자체제거하는 알라무티부호화 직교주파수분할다중방식을 사용함으로써 그 정확도를 높인다. 따라서, 제안하는 방식은 단 1회의 제거과정을 수행함에도 수회의 반복연산을 필요로 하는 기존의 알라무티부호화 직교주파수분할다중방식을 사용한 간섭제거 방식에 비해 개선된 성능을 가진다.