발전소 배관계의 내진해석 (Seismic Analysis of Power Plant Piping System)

  • 김정현;이영신;김연환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.480-485
    • /
    • 2011
  • In this study, the seismic analysis of power plant piping system was performed using finite element model. This study was performed by ANSYS 12.1. For qualification of power plant piping system, the response spectrum analysis was performed using the given operating basis earthquake(OBE) and safe shutdown earthquake(SSE) floor response spectrum. The maximum stresses of power plant piping system were 166 MPa under OBE condition and 281 MPa under SSE condition. Thus, it can shown that the structural integrity of tpower plant piping system has a stable structure for seismic load conditions.

  • PDF

등가단자유도 방법에 따른 다자유도 교량의 지진응답평가 (Evaluation of Seismic Response of Multi-Degree of Freedom Bridge Structures According to The ESDOF Method)

  • 송종걸;남왕현;정영화
    • 산업기술연구
    • /
    • 제25권A호
    • /
    • pp.23-30
    • /
    • 2005
  • The capacity spectrum method(CSM) can be used for the evaluation of inelastic maximum response of structures and has been recently used in the seismic design using the incorporation of pushover analysis and response spectrum method. To efficiently evaluate seismic performance of multi-degree-of freedom(MDOF) bridge structures, it is important that the equivalent response of MDOF bridge structures should be calculated. To calculate the equivalent response of MDOF system, equivalent responses are obtained by using Song method, Fajfar method and Calvi method. Also, those responses are applied to CSM method and seismic performance of bridge according to the ESDOF method are compared and evaluated straightforwardly.

  • PDF

Effect of slab stiffness on floor response spectrum and fragility of equipment in nuclear power plant building

  • Yousang Lee;Ju-Hyung Kim;Hong-Gun Park
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.3956-3972
    • /
    • 2023
  • The floor response spectrum (FRS) is used to evaluate the seismic demand of equipment installed in nuclear power plants. In the conventional design practice of NPP structure, the FRS is simplified using the lumped-mass stick model (LMSM), assuming the floor slab as a rigid diaphragm. In the present study, to study the variation of seismic response in a floor, the FRSs at different locations were generated by 3-D finite element model, and the response was compared to that of the rigid diaphragm model. The result showed that the FRS significantly varied due to the large opening in a floor, which was not captured by the rigid diaphragm model. Based on the result, seismic fragility analysis was performed for the anchorage of a heat exchanger, to investigate the effect of location-dependent FRS disparity on the high confidence low probability of failure (HCLPF).

비구조요소의 내진 설계를 위한 층응답스펙트럼 생성 기법 (A Method for Generating Floor Response Spectra for Seismic Design for Non-Structural Components)

  • 장성진;박동욱;김재봉
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권1호
    • /
    • pp.154-162
    • /
    • 2019
  • 세계적으로 지진과 같은 자연재해로 인한 대규모 피해가 증가하고 있다. 다양한 연구를 통하여 건물에 대한 내진성능은 확보되었으나, 비구조요소의 내진성능 확보 미흡으로 인하여 인명 피해 및 경제적 손실이 발생하고 있다. 비구조요소는 구조물에 설치되는 위치가 다양하고, 구조물의 위치에 따라 발생하는 진동특성이 다르므로 구조물의 위치별 응답스펙트럼이 필요하다. 또한 구조물의 형식과 구조물이 설치되는 위치에 따라 구조물에 발생하는 응답스펙트럼이 다르게 발생한다. 따라서 응답스펙트럼의 선정이 중요하므로 비구조요소에 작용하는 응답스펙트럼을 도출할 수 있는 명확한 방법이 필요하다. 본 논문에서는 응답스펙트럼을 도출하는 방법을 제안하였으며, 제안한 방법으로 국내에서 발생 가능한 지반응답스펙트럼과 구조시스템을 선정하여 구조해석을 수행하였다. 또한, 간단한 수식으로 응답스펙트럼을 도출하는 방법을 제안함으로서, 비구조요소의 내진시험에 필요한 응답스펙트럼을 생성할 수 있도록 하였다.

기존 학교 건축물의 내진성능평가 및 보강방안 제안 (Proposed Seismic Performance Evaluation Enhancement for Existing School Building)

  • 황지훈;장정현;양경석;최재혁
    • 교육시설 논문지
    • /
    • 제19권4호
    • /
    • pp.29-38
    • /
    • 2012
  • Recently large scale earthquake s are occurred around the world following the damage of buildings. So the interest of preparing for earthquake seismic design and seismic performance has becoming high. School buildings are though used for educational purpose; they are also used as emergency shelter for local residents during earthquake disaster. However, the current seismic design ratio of our country (Korea) is 3.7% and if massive earthquake is occurred it follows a serious damage. In order to overcome this situation, seismic performance evaluation is carried out for existing school building and an accurate and appropriate seismic retrofit is required based on performance evaluation to upgrade the existing school buildings. In this paper, nonlinear static analysis on existing school buildings for ATC-40 and FEMA-356 are carried out using the capacity spectrum method to evaluate seismic performance and to determine the need for retrofitting. In addition, after reinforcement to verify the effect of retrofit enhance the seismic performance is applied the seismic performance evaluation is carried out to verify the effect of seismic retrofit time history analysis using nonlinear dynamic analysis is also performed and nonlinear behavior of earthquake load of seismic retrofit of structures was also investigated.

면진된 모형디젤발전기의 지진응답실험 (The Shaking Table Test of Isolated Model EDG System)

  • 김민규;전영선
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.479-486
    • /
    • 2006
  • This paper presents tile results of experimental studies of the isolated Model EDG Systems. For the experimental work, the scaled model of EDG system and the isolation systems were developed. The target EDG model is 16PC2-5V400 which was manufactured by the SEMT Pielstick corporation. The Coil Spring and Viscous Damper Systems were selected for the isolation system. The Coil Spring and Viscous Damper systems can reduce not only seismic forces but also the operating vibration. For the input seismic motions, the scenario earthquake and the artificial earthquakes which were developed as NRC design spectrum and Uniform hazard Spectrum(UHS) were selected. As a result, at least 20% of seismic forces were decreased as the isolation system.

  • PDF

깊게 파인 온통기초가 구조물의 수평방향 설계스펙트럼에 미치는 영향 (Effect of a Sunken Mat Foundation on the Horizontal Design Spectrum of a Structure)

  • 김용석
    • 한국지진공학회논문집
    • /
    • 제25권4호
    • /
    • pp.169-177
    • /
    • 2021
  • In this paper, horizontal seismic responses of a structure built on a sunken mat foundation were compared with those built on a solid embedded mat foundation to investigate the effect of a sunken mat foundation on the horizontal response of a structure. Seismic analyses of a structure laid on the embedded mat foundation were performed by utilizing a pseudo-3D finite element software of P3DASS. Three bedrock earthquake records downloaded from the Pacific Earthquake Engineering Research Center database were scaled to reproduce weak-moderate earthquakes. Weak, medium, and stiff soil layers were considered for the seismic analyses of the structure-foundation-soil system. Parametric studies were performed for foundation radius, foundation embedment depth, and shear wave velocity of a soil layer to investigate their effect on the seismic response spectrum. The study result showed that the design spectrum of a structure built on a sunken mat foundation was similar to that with a solid embedded mat foundation showing a slight difference due to almost the same seismic base motion beneath both embedded foundations.

최근 백령도해역 발생지진의 지진원 및 응답스펙트럼 특성 분석 (Analysis of Characteristics of Seismic Source and Response Spectrum of Ground Motions from Recent Earthquake near the Backryoung Island)

  • 김준경
    • 지구물리와물리탐사
    • /
    • 제14권4호
    • /
    • pp.274-281
    • /
    • 2011
  • 최근 백령도 해역에서 발생한 규모 4.3에 해당하는 중규모 지진(2011년 6월 17일)으로부터 관측된 지반진동 파형을 이용하여 지진원 기구 및 수평 응답스펙트럼을 분석하였다. 분석결과를 한반도의 응력방향과 비교하였고 또한 국내 원자력 관련 구조물의 내진설계 기준과 국내 일반 구조물 및 건축물 내진설계기준과 각각 비교하였다. 지진원 연구에 이용된 지반진동은 3개 관측소(각 관측소에서 3성분)에서 관측된 전파형에 대해 모멘트텐서 기본식을 이용한 격자탐색법을 적용하여 분석하였다. 지진원기구에서 제시하는 주압축응력 방향은 ENE-WSW 방향으로 기존 한반도 전체의 주 응력방향과 대체로 유사하였다. 원자력 관련 구조물의 내진설계 기준과 국내 일반 구조물 및 건축물 내진설계기준과 각각 비교하였다. 국내 원자력시설물의 내진기준으로 이용되고 있는 Reg. Guide 1.60과 비교한 결과 특히 약 3 Hz 이상의 높은 고유진동수 영역에서 Reg. Guide 1.60 기준보다 높은 값을 보여 주었다. 또한 국내 일반 구조물 및 건축물 내진설계기준인 표준 설계응답스펙트럼을 비교한 결과 약 0.8초 이하의 단주기 영역의 전체 대역(SD 지반조건)에서 자료처리 결과가 기준을 크게 초과하였다. 향후 국내 지진활동 실정에 적합한 내진설계 기준 마련을 위해 관측자료의 질적 향상 및 양적인 축적 등을 통하여 특히 높은 고유진동수 대역에서 수평응답스펙트럼 기준의 보수성을 재고할 필요가 있다.

성능스펙트럼법을 이용한 기존 학교 건축물의 내진성능평가 및 보강효과 검증 (An Evaluation of Seismic Performance for Existing School Building Using Capacity Spectrum Method)

  • 장정현;황지훈;양경석;;최재혁
    • 공학기술논문지
    • /
    • 제5권1호
    • /
    • pp.11-18
    • /
    • 2012
  • Large scale earthquake was occurred in different parts of the world like Japan (in 1995), Republic of Pakistan (2005), in China (2008) etc and enormous structures were damaged. As a result of collapse of school buildings structures numerous students are died and it had a big impact on the international community. Therefore, the interest of preparing the seismic resistant school building structures in our country is increases as school building are used as emergency shelter for local residents. But the current standard of seismic design ratio of 3.7% is applied for school building in Korea which is only significant earthquake damage is expected. In order to overcome the current situation, seismic performance evaluation is carried out for the existing school building and an accurate and appropriate seismic retrofit is required based on performance evaluation to upgrade the existing school buildings. In this paper, nonlinear analysis on existing school buildings for ATC-40(Applied Technology Council, ATC) and FEMA-356(Federal Emergency Management Agency, FEMA) are carried out using the capacity spectrum method to evaluate seismic performance and to determine the need for retrofitting. In addition, after reinforcement to enhance the seismic performance is applied the seismic performance evaluation is carried out to verify the effectiveness of seismic retrofit.

중진지역 교량 내진설계와 응답수정계수 (Seismic Design of Bridges in Moderate Seismic Region and Response Modification Factors)

  • 국승규;이동욱
    • 한국전산구조공학회논문집
    • /
    • 제22권1호
    • /
    • pp.65-72
    • /
    • 2009
  • 도로교설계기준은 일반교량에 대한 내진설계방법으로 응답수정계수를 사용하는 스펙트럼해석법을 제시하고 있다. 그러나 중진지역이라는 한반도의 상황과 국내의 교량설계 및 시공환경에 대한 적용성은 아직 검증되지 않은 실정이다. 그러므로 도로교설계기준의 스펙트럼해석법을 적용하여 내진설계의 기본개념으로 제시되는 붕괴방지수준이 만족되는가에 대한 검토가 요구된다. 이 연구에서는 T형 및 ${\prod}$형 교각을 하부구조로 하는 두 개의 일반교량을 해석대상교량으로 선정하고, 중진지역의 설계조건과 스펙트럼해석법을 적용하여 내진설계를 수행하였다. 이 과정에서 응답수정계수의 역할과 붕괴방지수준의 만족여부를 검토하고, 그 결과를 토대로 설계기준에 보완해야 하는 사항을 제시하였다.