Seismic Analysis of Power Plant Piping System

발전소 배관계의 내진해석

  • 김정현 (충남대학교 기계설계공학과 대학원) ;
  • 이영신 (충남대학교 기계설계공학과) ;
  • 김연환 (한국전력공사 전력연구원)
  • Published : 2011.10.27

Abstract

In this study, the seismic analysis of power plant piping system was performed using finite element model. This study was performed by ANSYS 12.1. For qualification of power plant piping system, the response spectrum analysis was performed using the given operating basis earthquake(OBE) and safe shutdown earthquake(SSE) floor response spectrum. The maximum stresses of power plant piping system were 166 MPa under OBE condition and 281 MPa under SSE condition. Thus, it can shown that the structural integrity of tpower plant piping system has a stable structure for seismic load conditions.

Keywords