• 제목/요약/키워드: seismic reduction

검색결과 528건 처리시간 0.026초

Seismic performance and damage assessment of reinforced concrete bridge piers with lap-spliced longitudinal steels

  • Chung, Young S.;Park, Chang K.;Lee, Eun H.
    • Structural Engineering and Mechanics
    • /
    • 제17권1호
    • /
    • pp.99-112
    • /
    • 2004
  • It is known that lap splices in the longitudinal reinforcement of reinforced concrete (RC) bridge columns are not desirable for seismic performance, but it is sometimes unavoidable. Lap splices were practically located in the potential plastic hinge region of most bridge columns that were constructed before the 1992 seismic design provisions of the Korea Bridge Design Specification. The objective of this research is to evaluate the seismic performance of reinforced concrete (RC) bridge piers with lap splicing of longitudinal reinforcement in the plastic hinge region, to develop an enhancement scheme for their seismic capacity by retrofitting with glassfiber sheets, and to assess a damage of bridge columns subjected to seismic loadings for the development of rational seismic design provisions in low or moderate seismicity region. Nine (9) test specimens with an aspect ratio of 4 were made with three confinement ratios and three types of lap splice. Quasi-static tests were conducted in a displacement-controlled way under three different axial loads. A significant reduction of displacement ductility was observed for test columns with lap splices of longitudinal reinforcements, whose displacement ductility could be greatly improved by externally wrapping with glassfiber sheets in the plastic hinge region. A damage of the limited ductile specimen was assessed to be relatively small.

Influence of the deteriorated anti-seismic devices on seismic performance and device behavior of continuous girder bridges

  • Shangtao Hu;Renkang Hu;Menggang Yang;Dongliang Meng
    • Earthquakes and Structures
    • /
    • 제24권5호
    • /
    • pp.333-343
    • /
    • 2023
  • Various seismic isolation and reduction devices have been applied to suppress the longitudinal vibration of continuous girder bridges. As representative devices, lead rubber bearing (LRB) and fluid viscous damper (FVD) might suffer from deterioration during the long-term service. This study aims to evaluate the impact of device deterioration on the seismic responses of continuous girder bridges and investigate the seismic behavior of deteriorated LRBs and FVDs. Seismic performance of a simplified bridge model was investigated, and the influence of device deterioration was evaluated by the coefficient of variation method. The contribution of LRB and FVD was assessed by the Sobol global sensitivity analysis method. Finally, the seismic behaviors of deteriorated LRBs and FVDs were discussed. The result shows that (i) the girder-pier relative displacement is the most sensitive to the changes in the deterioration level, (ii) the deterioration of FVD has a greater effect on the structural responses than that of LRB, (iii) FVD plays a major role in energy dissipation with a low degradation level while LRB is more essential in dissipating energy when suffering from high degradation level, (iv) the deteriorated devices are more likely to reach the ultimate state and thus be damaged.

축소 적층고무베어링을 설치한 시설물의 지반진동 분리에 관한 실험 연구 (An Experimental Study on the Base Isolation of Equipments using Small-Scale Laminated Rubber Bearings)

  • 민경원
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall
    • /
    • pp.351-358
    • /
    • 1999
  • The base-isolation technology is to set up LRB between the base of a building and the ground to protect the building from seismic force. As Korea belongs to the region of moderate or weak seismicity it is more resonable to apply the base-isolation technology of LRB in the field of the response reduction of equipments under machine or transportation vibrations than in the field of seismic response reduction of buildings, In this paper small-scale LRB's designed for the response reduction of equipments are manufactured and tested for thier performance. The shaking table test is conducted to analyze the characteristics of LRB such as the variation of natural frequencies damping ratios and equipments responses.

  • PDF

Seismic Performance and Retrofit of Circular Bridge Piers with Spliced Longitudinal Steel

  • Chung, Young-Soo;Lee, Jae-Hyung
    • KCI Concrete Journal
    • /
    • 제14권3호
    • /
    • pp.130-137
    • /
    • 2002
  • It is known that lap splice in the longitudinal reinforcement of reinforced concrete(RC) bridge columns is not desirable for seismic performance, but it is sometimes unavoidable. Lap splices were practically located in the potential plastic hinge region of most bridge columns that were constructed before the adoption of the seismic design provision of Korea Bridge Design Specification on 1992. The objective of this research is to evaluate the seismic performance of reinforced concrete(RC) bridge piers with lap splicing of longitudinal reinforcement in the plastic hinge region, to develop the enhancement scheme of their seismic capacity by retrofitting with glassfiber sheets, and to develop appropriate limited ductility design concept in low or moderate seismicity region. Nine test specimens in the aspect ratio of 4 were made with three confinement ratios and three types of lap splice. Quasi-static test was conducted in a displacement-controlled way under three different axial load levels. A significant reduction of displacement ductility ratios was observed for test columns with lap splices of longitudinal steels.

  • PDF

A Simple Procedure of Seismic Performance Evaluation for Unreinforced Masonry Buildings in Korea

  • Kim, Taewan
    • Architectural research
    • /
    • 제15권3호
    • /
    • pp.159-166
    • /
    • 2013
  • This study was aimed at analyzing the three-step seismic performance evaluation procedure of Korea Infrastructure Safety Cooperation and proposing a new procedure suitable for unreinforced masonry buildings in Korea. For the study, it was investigated the performance evaluation results of five example URM buildings. First of all, it was found that the performance evaluation procedure for the URM buildings should be different from that for the other structural systems. As a result, a simple procedure of seismic performance evaluation was proposed, which includes elimination of elastic and inelastic push-over analysis and reduction of performance levels and evaluation steps. With the simple procedure, the URM buildings could be evaluated more easily than the other structures. It would be expected that the procedure can provide structural engineers with a simple and easy way to evaluate the seismic performance of the Korean URM buildings. Nevertheless, the procedure must be revised continuously by reflecting new research products for the URM buildings in Korea.

비탄성 설계스펙트럼에 대한 이력거동 특성의 영향 (Effect of Hysteretic Characteristics on Inelastic Seismic Design Spectra)

  • 오영훈;한상환;이리형
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.207-214
    • /
    • 1997
  • Current seismic design code is based on the assumption that the designed structures would be behaved inelastically during a severe earthquake ground motion. For this reason, seismic design forces calculated by seismic codes are much lower than the forces generated by design earthquakes which makes structures responding elastically. Present procedures for calculating seismic design forces are based on the use of elastic spectra reduced by a strength reduction factors known as "response modificaion factor". The effect of hysteretic behavior, as well as maximum ductility ratio and period on the inelastic strength demand is investigated. Special emphasis is given to the effects of the hysteretic characteristics such as strength degradation or pinching. Results indicate that inelastic strength demands are strongly dependent on level of inelastic deformation, period and hysteretic behavior.

  • PDF

Seismic assessment of thin steel plate shear walls with outrigger system

  • Fathy, Ebtsam
    • Structural Engineering and Mechanics
    • /
    • 제74권2호
    • /
    • pp.267-282
    • /
    • 2020
  • The seismic performance and failure modes of the dual system of moment resisting frames and thin steel plate shear walls (TSPSWs) without and with one or two outrigger trusses are studied in this paper. These structural systems were utilized to resist vertical and lateral loads of 40-storey buildings. Detailed Finite element models associated with nonlinear time history analyses were used to examine seismic capacity and plastic mechanism of the buildings. The analyses were performed under increased levels of earthquake intensities. The models with one and two outriggers showed good performance during the maximum considered earthquake (MCE), while the stress of TSPSWs in the model without outrigger reached its ultimate value under this earthquake. The best seismic capacity was in favour of the model with two outriggers, where it is found that increasing the number of outriggers not only gives more reduction in lateral displacement but also reduces stress concentration on thin steel plate shear walls at outrigger floors, which caused the early failure of TSPSWs in model with one outrigger.

비내진 상세를 가진 RC 보-기둥 접합부의 지진 거동 (Seismic Behavior of Nonseismically Detailed Reinforced Concrete Beam-Column Joints)

  • 우성우;이한선
    • 콘크리트학회논문집
    • /
    • 제15권6호
    • /
    • pp.894-901
    • /
    • 2003
  • 본 연구의 목적은 비내진 상세를 가진 RC 구조물의 이력거동 특성과 내진성능 및 특성을 알아보기 위한 것이다. 이를 위해 10층 RC구조물의 내 외부 접합부를 선정하여 슬래브의 유무, 접합부내에서의 전단철근 유무, 외부 접합부의 보 하부 주근의 정착방향에 따라 6개의 1/3 축소 실험체를 만들어 반복횡하중 실험을 수행하였다. 실험결과 내부 접합부의 경우 슬래브의 유무에 관계없이 내진 비내진 상세의 상이에 따른 강도나 연성 능력의 변화는 크지 않는 것으로 나타났고, 외부 접합부의 경우 내부 접합부와는 달리 접합부 전단 보강근의 유무뿐만 아니라 하단 주철근 정착방향에서도 차이가 나기 때문에 비내진 상세의 강도나 연성 능력이 각각 10∼20%와 27% 정도 작은 것으로 나타났다. 또, 비내진 상세를 가지는 경우 국부 변형이 한 곳에서 집중되어 크게 나타남을 알 수 있으며, 슬래브가 있음으로 인해 휨에 의한 회전각을 억제하고 상향 전단변형을 억제하는 것으로 나타났다. 한편 보-기둥 접합부에서의 전단 보강근은 전단변형률에 거의 영향을 끼치지 않는 것으로 나타났다.

진동주기가 다른 듀얼프레임을 이용한 내진보강시스템의 성능검증을 위한 실험적 연구 (An Experiment Study on Verification for the Performance of Seismic Retrofit System Using of Dual Frame With Different Eigenperiod)

  • 오상훈;최광용;유홍식;김영주
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권5호
    • /
    • pp.91-100
    • /
    • 2018
  • 본 연구에서 제안하는 내진보강기법은 듀얼시스템으로 비내진상세로 설계된 저층구조물을 대상으로 적용하기 위한 기법이다. 듀얼시스템은 기존의 구조체, 외부보강체, 강재이력댐퍼로 구성되고 구조체와 외부보강체 사이에 강재이력댐퍼를 설치한다. 구조체와 외부보강체는 강성과 적재하중에 의해 서로 다른 주기에 의해 상대변위가 발생되고 강재이력댐퍼를 통해 지진에너지를 흡수한다. 본 연구에서 제안된 듀얼시스템의 내진성능을 검증하기 위해 동적실험을 수행한다. 동적 실험결과, 듀얼시스템 보강 시 에너지가 1.84배 더 많이 입력됨에도 불구하고 56%의 변형 저감과, 93%의 손상 저감이 됨에 따라 듀얼시스템 적용 시 내진성능을 향상시킬 것으로 판단된다. 그리고 연구결과는 듀얼시스템의 설계범위를 설정하기 위한 추후 연구의 기초자료로 제시하고자 한다.

Nonlinear, seismic response spectra of smart sliding isolated structures with independently variable MR dampers and variable stiffness SAIVS system

  • Nagarajaiah, Satish;Mao, Yuqing;Saharabudhe, Sanjay
    • Structural Engineering and Mechanics
    • /
    • 제24권3호
    • /
    • pp.375-393
    • /
    • 2006
  • Under high velocity, pulse type near source earthquakes semi-active control systems are very effective in reducing seismic response base isolated structures. Semi-active control systems can be classified as: 1) independently variable stiffness, 2) independently variable damping, and 3) combined variable stiffness and damping systems. Several researchers have studied the effectiveness of independently varying damping systems for seismic response reduction of base isolated structures. In this study effectiveness of a combined system consisting of a semi-active independently variable stiffness (SAIVS) device and a magnetorheological (MR) damper in reducing seismic response of base isolated structures is analytically investigated. The SAIVS device can vary the stiffness, and hence the period, of the isolation system; whereas, the MR damper enhances the energy dissipation characteristics of the isolation system. Two separate control algorithms, i.e., a nonlinear tangential stiffness moving average control algorithm for smooth switching of the SAIVS device and a Lyapunov based control algorithm for damping variation of MR damper, are developed. Single and multi degree of freedom systems consisting of sliding base isolation system and both the SAIVS device and MR damper are considered. Results are presented in the form of nonlinear response spectra, and effectiveness of combined variable stiffness and variable damping system in reducing seismic response of sliding base isolated structures is evaluated. It is shown that the combined variable stiffness and variable damping system leads to significant response reduction over cases with variable stiffness or variable damping systems acting independently, over a broad period range.