DOI QR코드

DOI QR Code

An Experiment Study on Verification for the Performance of Seismic Retrofit System Using of Dual Frame With Different Eigenperiod

진동주기가 다른 듀얼프레임을 이용한 내진보강시스템의 성능검증을 위한 실험적 연구

  • Received : 2018.06.05
  • Accepted : 2018.08.31
  • Published : 2018.09.01

Abstract

The new seismic retrofit system in study propose is the Dual system, which aims to be applied to the seismically vulnerable low-story buildings. The Dual system is composed of existing structure, external retrofit frame and hysteretic steel dampers installed between former two components. The Dual system dissipates the energy by plastic deformation of steel damper caused by relative displacement due to the differences in stiffness, weight, and eigenperiod of each components. The dynamic test with shaking table was performed to verify the seismic performance of the proposed Dual system. As a result of the dynamic test, it is expected that the Dual system will improve the seismic performance due to the reduction of strain of 56% and the damage reduction of 93%, even though the energy is 1.84 times higher than that of the dual system. And the results of the study are presented as basic data of the study for setting the design range of the dual system.

본 연구에서 제안하는 내진보강기법은 듀얼시스템으로 비내진상세로 설계된 저층구조물을 대상으로 적용하기 위한 기법이다. 듀얼시스템은 기존의 구조체, 외부보강체, 강재이력댐퍼로 구성되고 구조체와 외부보강체 사이에 강재이력댐퍼를 설치한다. 구조체와 외부보강체는 강성과 적재하중에 의해 서로 다른 주기에 의해 상대변위가 발생되고 강재이력댐퍼를 통해 지진에너지를 흡수한다. 본 연구에서 제안된 듀얼시스템의 내진성능을 검증하기 위해 동적실험을 수행한다. 동적 실험결과, 듀얼시스템 보강 시 에너지가 1.84배 더 많이 입력됨에도 불구하고 56%의 변형 저감과, 93%의 손상 저감이 됨에 따라 듀얼시스템 적용 시 내진성능을 향상시킬 것으로 판단된다. 그리고 연구결과는 듀얼시스템의 설계범위를 설정하기 위한 추후 연구의 기초자료로 제시하고자 한다.

Keywords

References

  1. ACI Committee 318 (2011), Building Code Requirements for Structural Concrete (ACI 318-11) and Commentary, American Concrete Institute, Farmington Hills, 213-214.
  2. AIK(2010), Guideline and Examples for Vibration Control System Design, Kimoondang, 34-39 (in Korean).
  3. Baek, E. L., Oh, S. H., Lee, S. H. (2014), Seismic Performance of an Existing Low-Rise Reinforced Concrete, J. of Earthq. Eng. Soc. of Korea, EESK, 18(5), 241-251 (in Korean). https://doi.org/10.5000/EESK.2014.18.5.241
  4. Japan Building Disaster Prevention Association, JBDPA(2001), Standard for Seismic Evaluation of Existing Reinforced Concrete Building. 30-35.
  5. Japan Building Disaster Prevention Association, JBDPA(2002), External Seismic Retrofit Manual. 3-5.
  6. Kim, K. M., , Oh, S. H., Choi, K. Y., Lee, J. H., Park, B. C. (2013), Quantitative Damage Index of RC Columns with Non-seismic Details, J. of Korea Ins. for Struct. Maint. and Insp., KSMI, 17(6), 11-20. (in Korean). https://doi.org/10.11112/jksmi.2013.17.6.011
  7. Kim, K. M., Lee, S. H., Oh, S. H. (2013), Seismic Performance Evaluation of Existing Low-rise RC Frames with Non-seismic Detail, J. of Earthq. Eng. Soc. of Korea, EESK, 18(5), 241-251. (in Korean). https://doi.org/10.5000/EESK.2014.18.5.241
  8. Lee, K. S., Wi, J. D., Kim, Y. I., Lee, H. H., (2009), Seismic Safety Evaluation of Korean R/C School Buildings Built in the 1980s, J. of Korea Ins. for Struct. Maint. and Insp., KSMI, 19(1), 013-022 (in Korean).
  9. Lee, K. S. (2015), Seismic Performance Evaluation of Medium-and Low-rise R/C Buildings Strengthened with RCSF, J. of Korea Ins. for Struct. Maint. and Insp., KSMI, 19(1), 013-022 (in Korean)
  10. Minister of Land, Infrastructure and Transport, MOLIT (2016), Seismic Design Ratio of National Buildings, Korea (in Korean).
  11. National Disaster Management Research Institute, NDMI (2000), Study on the Repair and Retrofit Techniques for Improving Seismic performance of Existing Structure, Korea, 33-40 (in Korean).
  12. National Emergency Management Agency, NEMA (2011), Master Plan for Seismic Retrofit of Existing Public Facilities, Korea, 112-113 (in Korean).
  13. Oh, S. H. (2002), Earthquake-Resistant Design Method for Buildings Based on Energy Balance, Goomi Book. 108-112 (in Korean).
  14. Oh, S. H. Choi, K. Y., Ryu, H. S. (2012), Structural Performance Evaluations of Steel Hysteretic Damper, J. of Korean Soc. of Steel Const., KSSC 24(4), 371-382 (In Korean). https://doi.org/10.7781/kjoss.2012.24.4.371
  15. Oh, S. H. Choi, K. Y., Ryu, H. S. (2013), An Experimental Research on the Seismic Retrofit System Using of Eigenperiod, Proceeding of Workshop .Korean Soc. of Steel Const, KSSC, 241-242 (In Korean).