• Title/Summary/Keyword: seismic earthquake response

Search Result 1,592, Processing Time 0.03 seconds

Sensitivity analysis of self-centering rocking steel braced frames to far-field and near-field earthquakes

  • Masoomeh Naraghi;S. Mohammad Mirhosseini;Hossein Rahami;Abdolreza S. Moghadam
    • Steel and Composite Structures
    • /
    • v.53 no.2
    • /
    • pp.155-167
    • /
    • 2024
  • Identifying the location of earthquake-induced damage in buildings and mitigating its impact, especially in low-damage systems such as rocking frames, is a significant challenge for structural engineers. Therefore, it is crucial to investigate the sensitivity and type of damage of buildings exposed to severe earthquakes to concentrate damage in predefined locations that can be repaired easily. This paper explores the seismic responses of a Self-Centering Rocking Steel Braced Frame (SCR-SBF) under far-field and near-field ground motions. This earthquake-resistant system includes components such as post-tensioning cables to provide frame self-centering, eliminate residual drift in the system, and replaceable fuses to concentrate the earthquake-induced damage. While previous studies have examined far and near-field earthquakes, their comparative influence on the seismic behavior of structures with a rocking system remains unexplored. This paper presents a novel investigation into the sensitivity of SCR-SBF structures to far and near-field earthquakes. Considering the critical effects of shock and impulse loads on rocking systems, the study aims to assess the effects of near-field earthquakes and compare them to far-field earthquakes on these systems. For this purpose, different response parameters have been calculated under records of far- and near-field earthquakes at three specific ground acceleration levels by incremental nonlinear dynamic analysis. Additionally, the seismic behavior of the SCR-SBF and Steel-Braced Frame (SBF) are compared for near and far-field ground motions. The results show that SCR-SBF systems have better resilience and reduced local failures compared to SBF systems under far and near-field earthquakes, requiring tailored design strategies.

Seismic Performance Enhancement of Residential Flat Plate Structure by Using Base Isolation Devices. (면진장치를 사용한 주거용 무량판구조의 내진성능 향상)

  • Lee, Hyun Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.185-191
    • /
    • 2007
  • For the seismic performance enhancement of residential flat plate structure and for the selection of earthquake records, the possibility of base isolation is evaluated and the time history results are reviewed. By evaluating a base isolated stiffness, a target period, and an envelope curve analysis, seismic performance of structure, which has strong rotational mode, is evaluated. For the propriety evaluation of earthquake records usage and scaling method, time history analysis is done with variables such as DBE(design base earthquake) level, MCE(maximum considerable earthquake) level, and 1.4DBE level. From the analysis results, following conclusions can be made; the earthquake records, which are used in base isolation analysis, should be selected by similar soil type which the structure is considered, and should be intensity scaled in a range of mean ${\pm}$ standard deviation of code based design response spectrum.

Seismic Response of Arch Structure according to the Aspect Ratio and Columns (아치구조물의 형상비와 하부구조에 따른 지진응답특성에 관한 연구)

  • Seok, Keun-Young;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.3
    • /
    • pp.71-78
    • /
    • 2012
  • The dynamic behavior of spatial structures is different depending on the aspect ration of arch structure, as the rise-span ratio or open-angle, and these spatial structures show differently the character of seismic response in accordance with stiffness and connection of the lower support structures that are directly influenced by earthquake. Therefore, in this paper, dynamic analysis is conducted for seismic response of single layer arch structures by the influence of column's stiffness and connection, to reflect the different vertical and horizontal vibration mode of single layer arch structures. The vertical response of single layer arch structures is more influence by lower columns and the influence of column's connection rotational stiffness is not large, except to the hinged connections.

Seismic response of foundation-mat structure subjected to local uplift

  • El Abbas, Nadia;Khamlichi, Abdellatif;Bezzazi, Mohammed
    • Coupled systems mechanics
    • /
    • v.5 no.4
    • /
    • pp.285-304
    • /
    • 2016
  • The effects of large rotations and p-delta on the dynamic response of a structure subjected to seismic loading and local uplift of its foundation were analyzed in this work. The structure was modeled by an equivalent flexible mat mounted on a rigid foundation that is supported either by a Winkler soil type or a rigid soil. The equations of motion of the system were derived by taking into account the equilibrium of the coupled foundation-mat system where the structure was idealized as a single-degree-of-freedom. The obtained nonlinear coupled system of ordinary differential equations was integrated by using an adequate numerical scheme. A parametric study was performed then in order to evaluate the maximum response of the system as function of the intensity of the earthquake, the slenderness of the structure, the ratio of the mass of the foundation to the mass of the structure. Three cases were considered: (i) local uplift of foundation under large rotation with the p-delta effect, (ii) local uplift of foundation under large rotation without including the p-delta effect, (iii) local uplift of foundation under small rotation. It was found that, in the considered ranges of parameters and for moderate earthquakes, assuming small rotation of foundation under seismic loading can yield more adverse structural response, while the p-delta effect has almost no effect.

Seismic response evaluation of fixed jacket-type offshore structures by random vibration analysis

  • Abdel Raheem, Shehata E.;Abdel Aal, Elsayed M.;AbdelShafy, Aly G.A.;Fahmy, Mohamed F.M.
    • Steel and Composite Structures
    • /
    • v.42 no.2
    • /
    • pp.209-219
    • /
    • 2022
  • Offshore platforms in seismically active areas must be designed to survive in the face of intense earthquakes without a global structural collapse. This paper scrutinizes the seismic performance of a newly designed and established jacket type offshore platform situated in the entrance of the Gulf of Suez region based on the API-RP2A normalized response spectra during seismic events. A nonlinear finite element model of a typical jacket type offshore platform is constructed taking into consideration the effect of structure-soil-interaction. Soil properties at the site were manipulated to generate the pile lateral soil properties in the form of load deflection curves, based on API-RP2A recommendations. Dynamic characteristics of the offshore platform, the response function, output power spectral density and transfer functions for different elements of the platform are discussed. The joints deflection and acceleration responses demands are presented. It is generally concluded that consideration of the interaction between structure, piles and soil leads to higher deflections and less stresses in platform elements due to soil elasticity, nonlinearity, and damping and leads to a more realistic platform design. The earthquake-based analysis for offshore platform structure is essential for the safe design and operation of offshore platforms.

A Study on the Ductility of Concrete-Filled Composite Columns under Cyclic Loading (반복하중을 받는 콘크리트충전 강합성 기둥의 연성에 관한 연구)

  • 송준엽;권영봉;김성곤
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.6
    • /
    • pp.11-19
    • /
    • 2001
  • A series of test on concrete-filled composite columns was preformed to evaluate structural performance under axial compression and cyclic lateral loading. It was presented that concrete-filled composite columns had high strength, high stiffness and large energy-absorption capacity on account of mutual confinement between the steel plate and filled-in concrete. A cross section analysis procedure developed to predict the moment-curvature relation of composite columns was proven to be on accurate and effective method. The ductility factor and the response modification factor were evaluated for the seismic design of concrete-filled composite columns. It was shown that concrete-filled composite columns could be used as a very efficient earthquake-resistant structural member.

  • PDF

The Estimation of the Floor Vibration in Structure for Application of Response Spectrum Analysis Method (응답스펙트럼 해석법을 이용한 건축 구조물의 바닥진동해석)

  • 이동근;김태호
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.169-178
    • /
    • 1998
  • In general, the response spectrum analysis method is widely used for seismic analysis of building structures, and the time history analysis is applied for computation of structural vibration caused by equipments, machines and moving loads, etc. However, compared with the response spectrum analysis method, the time history method is very complex, difficult and time consuming. In this study, the maximum responses for the vertical vibration are calculated conveniently by the response spectrum method. At first, Response spectrum and time history analysis for some earthquake excitations are carried out, and the accuracy of maximum displacements obtained from response spectrum analysis is investigated. Secondly, the process for the response spectrum analysis in excitation is calculated, and the maximum modal responses are combined by CQC method. Finally, results of the proposed method are compared with those of the time history analysis.

  • PDF

Characteristics of Spectral Matched Ground Motions Time Histories According to Seed Ground Motion Selection (원본 지반운동 시간이력에 따른 스펙트럼 부합 시간이력의 특성)

  • Choi, Da Seul;Ji, Hae Yeon;Kim, Jung Han
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.25 no.1
    • /
    • pp.43-52
    • /
    • 2021
  • According to several seismic design standards, a ground motion time history should be selected similar to the design response spectrum, or a ground motion time history should be modified by matching procedure to the design response spectrum through the time-domain method. For the response spectrum matching procedure, appropriate seed ground motions need to be selected to maintain recorded earthquake accelerogram characteristics. However, there are no specific criteria for selecting the seed ground motions for applying this methodology. In this study, the characteristics of ground motion time histories between seed motions and spectral matched motions were compared. Intensity measures used in the design were compared, and their change by spectral matching procedure was quantified. In addition, the seed ground motion sets were determined according to the response spectrum shape, and these sets analyzed the response of nonlinear and equivalent linear single degrees of freedom systems to present the seed motion selection conditions for spectral matching. As a result, several considerations for applying the time domain spectral matching method were presented.

Behavior Analysis on Earthquake-Induced Deformation of Quay Wall and Apron in Ground at Youngilman Port Considering Drainage Condition Using FEM Analysis (FEM 해석에 의한 지반배수조건에 따른 지진 시 영일만항의 케이슨식 안벽 및 배후지의 거동 분석)

  • Lee, Hak-Ju;Kang, Gi-Chun;Hwang, Woong-Ki;Lee, Min-Sun;Kim, Tae-Hyung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.6
    • /
    • pp.386-394
    • /
    • 2019
  • In this study, according to drainage condition (undrained and drained) in ground, the settlement and horizontal displacement of caisson quay wall and apron in Yeongilman port due to excess pore water pressure in ground induced by the magnitude 5.4 earthquake in Pohang on November 15, 2017. In general, seismic response analysis was carried out under undrained drainage condition, but in this study, drain drainage analysis was conducted to estimate displacement during earthquake as well as an additional displacement due to dissipation of excess pore water pressure after earthquake. The result of after earthquake can not be known under undrained drainage condition. Results cleary showed that the behavior of structure and ground was dependent on drainage condition in ground. Especially, based on the drained drainage condition, the additional displacement was clearly detected due to dissipation of excess pore water pressure after earthquake. Which indicates that both results are different to drainage condition in ground, and therefore, drainage condition analysis is necessary to accurately estimate the behavior of ground and structure in seismic response analysis.

Applicability of Beam Model among Earthquake Response Analysis Models of Liquid-Storage Tank (액체저장탱크의 지진응답해석 모델 중 빔 모델의 적용성)

  • Jin, Byeong-Moo;Jeon, Se-Jin;Kim, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.696-699
    • /
    • 2004
  • Generally, the time history analysis among seismic response analyses of a structure needs more times than static analysis. Therefore the mechanical model of a structure has been used as a simple lumped parameter model in time history analysis. For the most cases, the simple mechanical model shows the similar results to that of detailed finite element model. so it is reasonable to use the simple mode] in preliminary analysis. In seismic design of liquid storage tank, such as LNG storage tank, the lumped parameter mode] also is being used in preliminary analysis, however sometimes shows the differences to the results of detailed finite element model. Therefore in this study, the dynamic characteristics between lumped parameter model and detailed finite model is compared for the variables such as height/diameter of liquid-storage tank and thickness of wall, then the applicability of beam mode] to the seismic response analysis are evaluated for some liquid storage tanks.

  • PDF