A Study on Vortex Pair Interaction with Fluid Free Surface (자유표면에 작용하는 와동 현상에 대한 연구)

  • Sohn K.;Ryu H. K.;Kim K. H.;Kim S. W.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.67-72
    • /
    • 2002
  • Today, the research to examine a fact that interaction between the air and the fluid free surface affects the steady state flow and air. We proved the interaction between vortex pairs and free surface on each condition that is created by the end of delta wings. another purpose of this study is to investigate the effect of surface active material which can change the surface tension and we must consider when we refer to turbulent flow on surface tension. therefore, this research examined the growth process of vortex pairs on condition of clean, contaminated free surface and wall after we made vortex pairs through counter rotating flaps. The results of this study suggest that vortex pairs in clean free surface rise safely but the vortex pairs in contaminated free surface and rigid, no slip is made secondary vortex or rebounding. However the secondary vortex in rigid, no slip is stronger than before, and we can find the vortex shape which roll up more completely. However, these will disappear by the effect of wall.

  • PDF

Fluid-elastic Instability Evaluation of Steam Generator Tubes

  • Cho, Young Ki;Park, Jai Hak
    • International Journal of Safety
    • /
    • v.11 no.1
    • /
    • pp.1-5
    • /
    • 2012
  • It has been reported that the plugged steam generator tube of Three Mile Island Unit 1 in America was damaged by growing flaw and then this steam generator tube destroyed the nearby steam generator tubes of normal state. On this account, stabilizer installation is necessary to prevent secondary damage of the steam generator tubes. The flow-induced vibration is one of the major causes of the fluid-elastic instability. To guarantee the structural integrity of steam generator tubes, the flow-induced vibration caused by the fluid-elastic instability is necessary to be suppressed. In this paper, the effective velocity and the critical velocity are calculated to evaluate the fluid-elastic instability. In addition, stability ratio value of the steam generator tubes is evaluated in order to propose one criterion when to determine stabilizer installation.

The Stability of Composite Pipes Conveying Fluid (유체유동에 의한 복합재료 파이프의 안정성 연구)

  • 최재운;송오섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.904-910
    • /
    • 2001
  • Static and oscillatory loss of stability of composite pipes conveying fluid is investigated. The theory of thin walled beams is applied and transverse shear, rotary inertia, primary and secondary warping effects are incorporated. The governing equations and the associated boundary conditions are derived through Hamilton's variational principle. The governing equations and the associated boundary conditions are transferred to eigenvalues problem which provides the information about the dynamic characteristics of the system. Numerical analysis is performed by using extended Gelerkin method. Critical velocity of fluid is investigated by increasing fiber angle and mass ratio of fluid to pipe including fluid.

  • PDF

Numerical analysis on heat transfer due to buoyancy force of viscoelastic fluid (점탄성 유체의 부력에 의한 열전달 수치해석)

  • Ahn S. T.;Sohn C. H.;Shin S. H.
    • Journal of computational fluids engineering
    • /
    • v.4 no.2
    • /
    • pp.9-16
    • /
    • 1999
  • The present study investigates flow character and heat transfer behaviors of viscoelastic non-Newtonian fluid in a 2:1 rectangular duct. An axially-constant heat flux on bottom wall and peripherally constant temperature boundary condition(H1) was adopted. The Reiner-Rivlin fluid model is used as the normal stress model for the viscoelastic fluid and temperature-dependent viscosity model is adopted. The present results show a signifiant change of the main flow field which causes a large heat transfer enhancement. This phenomena can be explained by the combined effect of buoyancy, temperature-dependent viscosity and viscoelastic property on the flow.

  • PDF

An Experimental Study on Heat Transfer Characteristics in the LHSS for Cool Thermal Air Conditioning (저온공조용 잠열 축열조의 열전달 특성에 관한 실험적 연구)

  • Seo, I.H.;Koh, J.Y.;Lee, C.M.;Yim, C.S.
    • Solar Energy
    • /
    • v.20 no.3
    • /
    • pp.11-19
    • /
    • 2000
  • In this study, the basic data which were required for development of LHSS(latent heat storage system) were experimentally obtained. Experiments were carried out under the following conditions. The initial temperatures of P.C.M. which were used by parameter is $5^{\circ}C,\;9^{\circ}C$ and $14^{\circ}C$. The conditions of working fluid are $-6^{\circ}C,\;-4^{\circ}C$, and $65{\ell}$/min.. The pure water of which the freezing point is $0^{\circ}C$ was filled in the system, and the Ethylene glycol(brine) was circulated through the 10 vertical tubes as a secondary fluid in order to cool the P.C.M. down. The inlet temperature of the secondary fluid and the initial temperature of the water were varied to investigate the effects of the important design parameters. The phenomenons of temperature conversion of P.C.M. were appeared for the conductive heat transfer and free convective heat transfer by buoyancy force in this storage unit system. In order to find the effective water circulation path, we obtained P.CM. temperature distributions of 5 parts in the storage tank during freezing process.

  • PDF

Numerical Analysis on the Low Momentum Fluid Flow Characteristics in Centrifugal Pump Impeller (원심 펌프 회전차 내부의 저 운동량 유동특성에 관한 수치적 연구)

  • 김세진;김동원;김윤제
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.05a
    • /
    • pp.151-157
    • /
    • 1999
  • In this study, tile characteristics of three dimensional flow fields in centrifugal flump impeller are investigated by numerically. Detailed analysis and understanding of flow field in centrifugal pump are very important to predict performance of components. The three dimensional viscous fluid flow in centrifugal pump is distingushed isentropic process region from irreversible process region by wall shear effect, secondary flow, centrifugal and Coriolis forces, variation of boudary layers. Development of low momentum region by viscous fluid flow in the centrifugal impeller causes stall and blockage which is irreversible process region, and resulting in decrease of the performance and efficiency of centrifugal pump. Especially, the result is that Coriolis and centrifugal forces are most powerful factors which are increasing the irreversible region.

  • PDF

Seismic Response Characteristics of Submerged Systems with Large Hydrodynamic Effect in Base-isolated Structure (지진절연 건물내 유체동적효과가 큰 수중계의 지진응답특성)

  • Shin, Tae-Myung;Kim, Kwang-Joon
    • Journal of KSNVE
    • /
    • v.7 no.4
    • /
    • pp.655-661
    • /
    • 1997
  • Base-isolation of a primary structure generally decrete the seismic response of its own and the secondary structure. It may cause an adverse effect on the seismic response of secondary system when the system is submerged and subject to a considerable hydrodynamic effect. In this paper, it is shown how, and how much, the base isolation of the primary structure can affect the secondary system response in extreme cases through dynamic analysis of a simplified coupled model for a submerged secondary system and a base-isolated primary structure. As an aseismatic design approach to reduce the response of the submerged system, optimization of the fluid gap, which controls the hydrodynamic mass effect, is performed. As an alternative approach in case where the control of fluid gap is unrealistic, application of base isolation to the submerged system is suggested. Effectiveness of various combinations of the primary base and secondary base isolations are compared.

  • PDF

Paleostress from Healed Microcracks and Fluid Inclusions in Quartz of the Jurassic Granites in the Southwestern Ogcheon Folded Belt (옥천습곡대 서남부지역에 분포하는 쥬라기 화강암류의 석영내 아문 미세균열 및 유체포유물을 이용한 고응력장)

  • Kang, Seong-Seung;Yoo, Bong-Chul;Jang, Bo-An;Kim, Cheong-Bin
    • Journal of the Korean earth science society
    • /
    • v.30 no.1
    • /
    • pp.19-32
    • /
    • 2009
  • Paleostress was interpreted by analyzing the healed microcracks and the secondary fluid inclusions in quartz of the Jurassic granites distributed in the southwestern Ogcheon Folded Belt, South Korea. The most dominant direction of healed microcracks in the study area was oriented $N30^{\circ}W$, and $N70^{\circ}W$ direction was also recognized. The formation temperatures of fluid inclusions were ranged $380-550^{\circ}C$ and the age of healed microcrack formations might have been approximately 166-200 Ma. Comparing the paleostress orientation obtained from the direction of healed microcracks to the formation age of healed microcracks estimated from the secondary fluid inclusions, it is considered that granitic rock body in study area was subject to a maximum horizontal principal stress along the NNW-SSE and WNW-ESE directions in the early Jurassic to middle Jurassic.

A Numerical Study on the Combustion Characteristics for Stoker Type Incinerator with Various Injection Type of Secondary Air (2차 공기 주입방식에 따른 스토커형 소각로의 연소특성에 관한 수치해석적 연구)

  • Jung, Jin;Kim, Chang-Nyeong;Cho, Young-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.835-842
    • /
    • 2003
  • A three dimensional numerical analysis has been conducted for a stoker type incinerator which has the capacity of 1.5 ton/hr. The objective of the present study is to predict the effects of swirl induced by secondary air and to find an optimal operating condition of the incinerator. In this study, combustion characteristics such as distributions of temperature, velocity and concentration of each species have been examined with various injection types of secondary air and with different flow rates of secondary air in the incinerator. It is found that the secondary air injection on the combustion process makes the path of fluid particle longer in the combustor and enhances the mixing between air and combustion gas by arousing a swirl. Therefore, the injection type of secondary air can be an important key in the design process of incinerator.