• Title/Summary/Keyword: scrubbing

Search Result 149, Processing Time 0.027 seconds

Analysis of the Single Event Effect of the Science Technology Satellite-3 On-Board Computer under Proton Irradiation (과학기술위성 3호 온보드 컴퓨터의 양성자 빔에 의한 Single Event Effect 분석)

  • Kang, Dong-Soo;Oh, Dae-Soo;Ko, Dae-Ho;Baik, Jong-Chul;Kim, Hyung-Shin;Jhang, Kyoung-Son
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.12
    • /
    • pp.1174-1180
    • /
    • 2011
  • Field Programmable Gate Array(FPGA)s are replacing traditional integrated circuits for space applications due to their lower development cost as well as reconfigurability. However, they are very sensitive to single event upset (SEU) caused by space radiation environment. In order to mitigate the SEU, on-board computer of STSAT-3 employed a triple modular redundancy(TMR) and scrubbing scheme. Experimental results showed that upset threshold energy was improved from 10.6 MeV to 20.3 MeV when the TMR and the scrubbing were applied to the on-board computer. Combining the experimental results with the orbit simulation results, calculated bit-flip rate of on-board computer is 1.23 bit-flips/day assuming in the worst case of STSAT-3 orbit.

Development and Field Application of an Amphibious Scrubbing/Suction Dredging Machine with Cylindrical Rotating Brush and Turbidity Barrier (회전브러쉬와 혼탁방지막을 활용한 수륙양용형 Scrub/흡입 준설장치의 개발과 현장적용)

  • Joo, Jin Chul;Kim, Wontae;Kim, Hyunseung;Kim, Hyunseol;Song, Ho Myun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.9
    • /
    • pp.495-504
    • /
    • 2017
  • An amphibious scrubbing/suction dredging machine with cylindrical rotating brush, housing, and turbidity barrier was newly-developed to remove both sediments with about 10 cm thickness and periphyton attached on various structures in urban water-circulating systems through the scrubbing, suction, and dredging processes. Based on the field application and long-term monitoring, the increase in both suspended solids (SS) and turbidity of water during the scrubbing, suction, and dredging processes was negligible (p>0.05). In some cases, the turbidity of water initially increased, however, the turbidity was stabilized within 20 minutes from the start of dredging processes. The concentration changes in TN and TP of water were not statistically different (p>0.05) before and after the scrubbing, suction, and dredging processes, indicating that benthic nutrients released from sediments were not significantly diffused, and were not supposed to cause significant water pollution. Also, water treatment facilities along with an amphibious scrubbing/suction dredging machine could be more effective since the removal of contaminant loadings through the scrubbing, suction, and dredging processes was much greater than that through simple coagulation/precipitation processes. Finally, GPS-based realtime tracking and operation program have been developed and applied in various urban water-circulating systems, and development of driver cooperative autonomous driving system is in progress to eliminate the need for manual driving of an amphibious scrubbing/suction dredging machine.

Soil Washing에 의한 세슘과 코발트 오염 토양 복원기술 개발

  • 김계남;원휘준;오원진;김민길
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.337-339
    • /
    • 2003
  • The technology removing radionuclides from soil using soil washing was studied. The main radionuclides contaminated in the soil are Cs$^{137}$ and Co$^{60}$ . It is suitable that scrubbing time is 4 hours and a mixing ratio of soil weight and washing solution volume is 1:10. more than two times continuous scrubbing method with 0.5 M oxalic acid was needed to remove Cs$^{137}$ and Co$^{60}$ from soil more than 70%. Radionuclides removal efficiencies of recycling washing solutions recycled with strong acid resins until 5 times are similar to that of 0.5 M oxalic acid.

  • PDF

AN EXPERIMENTAL STUDY ON THE EFFECT OF DENTINAL PRETREATMENT ON BOND STRENGTH BETWEEN GLASS IONOMER CEMENT AND DENTIN (상아질 전처리 방법이 상아질과 Glass Ionomer Cement간의 결합강도에 미치는 영향에 대한 실험적 연구)

  • Chung, Sang-Baek;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.2
    • /
    • pp.355-364
    • /
    • 1992
  • This is a study on the effect of the dentinal pretreatment method to the bond strength between dentin and glass ionomer cement. In this study, 196 human molar teeth with sound crown were used. The dentin surfaces of these teeth were exposed with wet trimmer and polished with # 800 Emory paper and teeth were divided into 7 groups according to the pretreatment agent and method. Each group has 4 subroups of the kinds of glass ionomers. The shear bond strength were measured by Instron Universal Testing machine model 1122. The data of the evaluations were then subjected to statistical analysis using one way ANOVA and the result were as follows : 1. In Durelon liquid 20 sec scrubbing & Vitrebond filling subgroup, shear bond strength was highest with measurements of 72.41(kg/$cm^2$) and in no pretreatment & Shofu lining cement filling subgroup, lowest with measurements of 4.77(kg/$cm^2$). 2. In no pretreatment group, statistical significant differences were found between the subgroups of G-C lining cement and Shofu lining cement. 3. In Ketac conditioner 20 sec scrubbing group, Vitrebond were bonded stronger than others, and in Ketac conditioner 10 sec passive contact group, it has the significant difference with other glass ionomers except G-C lining cement. 4. The subgroup og G-C dentin conditioner 20 sec scrubbing & G-C lining cement filling was bonded to dentin stronger than the subgroup of no pretreatment & Shofu lining cement. In G-C dentin conditioner groups, both of 10 sec passive contact and 20 sec scrubbing, Vitrebond has highest bond strength among the subgroups. 5. The subgroup of Durelon liquid 10 sec passive contact & G-C lining cement filling was bonded to dentin stronger than the subgroup of no pretreatment & Shofu lining cement. Also in both Durelon liquid groups, Vitrebond were bonded to dentin with the highest strength among the subgroups.

  • PDF

Removal of Inorganic Odorous Compounds by Scrubbing Techniques using Silver Nano-particles (나노 은 입자 세정법을 이용한 무기 악취물질의 제거)

  • Shin, Seung-Kyu;Huyen, Tran;Song, Ji-Hyeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.6
    • /
    • pp.674-681
    • /
    • 2008
  • Silver as a metal catalyst has been used to remove odorous compounds. In this study, silver particles in nano sizes ($5{\sim}30nm$) were prepared on the surface of $NaHCO_3$, the supporting material, using a sputtering method. The silver nano-particles were dispersed by dissolving $Ag-NaHCO_3$ into water, and the dispersed silver nano-particles in the aqueous phase was applied to remove inorganic odor compounds, $NH_3$ and ${H_2}O$, in a scrubbing reactor. Since ammonia has high solubility, it was removed from the gas phase even by spraying water in the scrubber. However, the concentration of nitrate (${NO_3}^-$) ion increased only in the silver nano-particle solution, implying that the silver nano-particles oxidized ammonia. Hydrogen sulfide in the gas phase was rapidly removed by the silver nano-particles, and the concentration of sulfate (${SO_4}^{2-}$) ion increased with time due to the oxidation reaction by silver. As a result, the silver nano-particles in the aqueous solution can be successfully applied to remove odorous compounds without adding additional energy sources and producing any harmful byproducts.

The study on removal of slurry particles on W plug generated during tungsten CMP (WCMP에서 발생되는 W plug내 slurry particle제거에 관한 연구)

  • Yang, Chan-Ki;Kwon, Tae-Young;Hong, Yi-Koan;Kang, Young-Jae;Park, Jin-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.366-367
    • /
    • 2006
  • In general, HF chemistry lifts off the particles during scrubbing after polishing and effectively removes particles. It is sometimes impossible to apply HF chemistry on W plug due to the degradation of electrical characteristics of a device. In this paper, a post W CMP cleaning process is proposed to remove residue particles without applying HF chemistry. After W CMP, recessed plugs are created, therefore they easily trap slurry particles during CMP process. These particles in recessed plug are not easy to remove by brush scrubbing when $NH_4OH$ chemistry is used for the cleaning because the brush surface can not reach the recessed area of plugs. Buffing with oxide slurry was followed by W CMP due to its high selectivity to W. The buffing polishes only oxide slightly which creates higher plug profiles than surrounding oxide. Higher profiles make the brush contact much more effectively and result in a similar particle removal efficiency even in $NH_4OH$ cleaning to that in HF brush scrubbing.

  • PDF

Performance evaluation of an improved pool scrubbing system for thermally-induced steam generator tube rupture accident in OPR1000

  • Juhyeong Lee;Byeonghee Lee;Sung Joong Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1513-1525
    • /
    • 2024
  • An improved mitigation system for thermally-induced steam generator tube rupture accidents was introduced to prevent direct environmental release of fission products bypassing the containment in the OPR1000. This involves injecting bypassed steam into the containment, cooling, and decontaminating it using a water coolant tank. To evaluate its performance, a severe accident analysis was performed using the MELCOR 2.2 code for OPR1000. Simulation results show that the proposed system sufficiently prevented the release of radioactive nuclides (RNs) into the environment via containment injection. The pool scrubbing system effectively decontaminated the injected RN and consequently reduced the aerosol mass in the containment atmosphere. However, the decay heat of the collected RNs causes re-vaporization. To restrict the re-vaporization, an external water source was considered, where the decontamination performance was significantly improved, and the RNs were effectively isolated. However, due to the continuous evaporation of the feed water caused by decay heat, a substantial amount of steam is released into the containment. Despite the slight pressurization inside the containment by the injected and evaporated steam, the steam decreased the hydrogen mole fraction, thereby reducing the possibility of ignition.

Enhancement of HF Gas Removal Efficiency of a Scrubber in Semiconductor Manufacturing Process by using ANCOVA Technique (ANCOVA를 이용한 반도체공정 스크러버 HF 가스 제거 개선)

  • Kim, S.J.;Lee, M.;Xu, J.;Lim, S.;Lee, H.;Koo, J.
    • Journal of ILASS-Korea
    • /
    • v.18 no.2
    • /
    • pp.81-86
    • /
    • 2013
  • To comply with the regulation of the reinforcing Clean Air Conservation Act, it is necessary for the semiconductor manufacturers to develop effective low-concentration acid gas abatement system to treat the flue gas. The low-concentration acid gas was found to be harder to deal with than the high-concentration one. In this study, the effect of various potential treatments such as air-assist nozzle spraying, magnetizing the scrubbing water, and adding surfactants to spraying and scrubbing water were investigate through the application of the statistical ANCOVA method, which was proved to be very useful tool when the inlet concentration of acid gas could not be controlled precisely and it affected the removal efficiency of the abatement system.

Optimization of In-Line Dry Scrubbing FGD process using Calcium Hydroxide and Effect of Additives (소석회를 사용한 In-Line형 건식탈황공정의 최적화와 첨가제의 영향)

  • 박재만;신창섭
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.2
    • /
    • pp.102-111
    • /
    • 1997
  • An In-line dry scrubbing FGD process was investigated. Calcium hydroxide was entrained in flue gas and the SO$_2$ removal efficiency by humidity and additives were examined. The range of reaction temperature was $200^{\circ}C$~$500^{\circ}C$ and the concentration of $SO_2$ was around 900ppm. By the increase of humidity in flue gas, the removal efficiency was increased. The effect of NaOH as a additive was very high and got high conversion of $Ca(OH)_2$, however in case of RH 90%, it was reverse. The effect of particle size and flow rate were examined. And the reaction rate constant and effective diffusivity also calculated.

  • PDF