• Title/Summary/Keyword: scattered dose

Search Result 169, Processing Time 0.031 seconds

Calibration of HEPD on KOMPSAT-1 Using the KCCH Cyclotron

  • Shin, Young-Hoon;Rhee, Jin-Geun;Min, Kyoung-Wook;Lee, Chun-Sik;Lee, Ju-Hahn;Kwon, Young-Kwan;Kim, Jong-Chan;Ha, Jang-Ho;Park, Se-Hwan;Lee, Chang-Hack;Park, H.S.;Kim, Yong-Kyun;Chai, Jong-Seo;Kim, Yu-Seog;Lee, Hye-Young
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.208-213
    • /
    • 1999
  • Space Physics Sensor (SPS) on-board the KOMPSAT-1 consists of the High Energy Particle Detector (HEPD) and the Ionospheric Measurement Sensor (IMS). The HEPD is to characterize the low altitude high energy particle environment and the effects on the microelectronics due to these high energy Particles. It is composed of four sensors: Proton and Electron Spectrometer(PES), Linear Energy Transfer Spectrometer (LET), Total Dose Monitor (TDM), and Single Event Monitor(SEM). 35MeV proton beam from the medical KCCH cyclotron, at Korea Cancer Center Hospital in Seoul, is used to calibrate the PES. Primary proton beam of 35MeV scattered by polypropylene target is converted to various energy Protons according to the elastic collision kinematics. In this calibration, the threshold level of the proton in the PES can be determined and the energy ranges of PES channels are also calibrated.

  • PDF

THE ADAPTATION METHOD IN THE MONTE CARLO SIMULATION FOR COMPUTED TOMOGRAPHY

  • LEE, HYOUNGGUN;YOON, CHANGYEON;CHO, SEUNGRYONG;PARK, SUNG HO;LEE, WONHO
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.472-478
    • /
    • 2015
  • The patient dose incurred from diagnostic procedures during advanced radiotherapy has become an important issue. Many researchers in medical physics are using computational simulations to calculate complex parameters in experiments. However, extended computation times make it difficult for personal computers to run the conventional Monte Carlo method to simulate radiological images with high-flux photons such as images produced by computed tomography (CT). To minimize the computation time without degrading imaging quality, we applied a deterministic adaptation to the Monte Carlo calculation and verified its effectiveness by simulating CT image reconstruction for an image evaluation phantom (Catphan; Phantom Laboratory, New York NY, USA) and a human-like voxel phantom (KTMAN-2) (Los Alamos National Laboratory, Los Alamos, NM, USA). For the deterministic adaptation, the relationship between iteration numbers and the simulations was estimated and the option to simulate scattered radiation was evaluated. The processing times of simulations using the adaptive method were at least 500 times faster than those using a conventional statistical process. In addition, compared with the conventional statistical method, the adaptive method provided images that were more similar to the experimental images, which proved that the adaptive method was highly effective for a simulation that requires a large number of iterations-assuming no radiation scattering in the vicinity of detectors minimized artifacts in the reconstructed image.

ANTI-TUMOR EFFECTS OF VASCULAR ENDOTHELIAL GROWTH FACTOR INHIBITOR ON ORAL SQUAMOUS CELL CARCINOMA CELL LINES (혈관내피세포성장인자 억제제에 의한 구강편평상피세포암종 세포주의 성장 억제 효과)

  • Han, Se-Jin;Lee, Jae-Hoon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.2
    • /
    • pp.66-73
    • /
    • 2009
  • Tumor angiogenesis is a process leading to formation of blood vessels within tumors and is crucial for maintaining a supply of oxygen and nutrients to support tumor growth and metastasis. Vascular endothelial growth factor(VEGF) plays a key role in tumor angiogenesis including induction of endothelial cell proliferation, migration, survival and capillary tube formation. VEGF binds to two distinct receptors on endothelial cells. VEGFR-2 is considered to be the dominant signaling receptor for endothelial cell permeability, proliferation, and differentiation. Bevacizumab(Avastin, Genetech, USA) is a monoclonal antibody against vascular endothelial growth factor. It is used in the treatment of cancer, where it inhibits tumor growth by blocking the formation of new blood vessels. The goal of this study is to identify the anti-tumor effect of Bevacizumab(Avastin) for oral squamous cell carcinoma cell lines. Human squamous cell carcinoma cell line(HN4) was used in this study. We examined the sensitivity of HN4 cell line to Bevacizumab(Avastin) by using in vitro proliferation assays. The results were as follows. 1. In the result of MTT assay according to concentration of Bevacizumab(Avastin), antiproliferative effect for oral squamous cell carcinoma cell lines was observed. 2. The growth curve of cell line showed the gradual growth inhibition of oral squamous cell carcinoma cell lines after exposure of Bevacizumab(Avastin). 3. In the apoptotic index, groups inoculated Bevacizumab(Avastin) were higher than control groups. 4. In condition of serum starvation, VEGFR-2 did not show any detectable autophosphorylation, whereas the addition of VEGF activated the receptor. Suppression of phosphorylated VEGFR-2 and phosphorylated MAPK was observed following treatment with Bevacizumab(Avastin) in a dose-dependent manner. 5. In TEM view, dispersed nuclear membrane, scattered many cytoplasmic vacuoles and localized chromosomal margination after Bevacizumab(Avastin) treatment were observed. These findings suggest that Bevacizumab(Avastin) has the potential to inhibit MAPK pathway in proliferation of oral squamous cell carcinoma cell lines via inhibition of VEGF-dependent tumor growth.

Study on the pathogenesis of the piglets experimentally infected with Korean isolate of Aujeszky′s disease virus I. Histopathologic and electron microscopic observation (Aujeszky's disease virus 국내분리주 접종자돈의 병리발생에 관한 연구 I. 병리학적 및 전자현미경적 관찰)

  • 조우영;조성환;김재훈;박최규;황의경;조부제;정운선
    • Korean Journal of Veterinary Service
    • /
    • v.19 no.1
    • /
    • pp.1-29
    • /
    • 1996
  • This study was conducted to elucidate the pathogenesis of Aujeszky's disease virus(ADV) by histopathologic examination. The first Korean ADV Isolate, which was isolated from piglets with clinical signs of Aujeszky's disease in Yangsan(YS) county, Kyungnam province, was inoculated into 32 days old piglets with a dose of $10^{5.9}$$TCID_{50}/ml$ through intranasal or intramuscular route. These piglets were sacrificed at intervals of every 24hrs for 8 days. The virulence of YS strain was determined by the observation of clinical signs, gross findings, and histopathologic changes in tissues. The virus recovery test was performed from brain, spleen, lung and tonsil in cell culture. The pathogenesis of YS strain was determined by the observation of histopathologlc lesions in CNS and neuronal tracts. The major clinical signs were fever, anorexia, dyspnea, constipation, tremor, ataxia, circling movement, hindleg paralysis and salivation. The clinical signs were more severe in piglets of the group inoculated intranasally than those of the intramuscularly inoculated gorup. Lymphocytopenia was detected on day 5 to day 6 postinoculation (PI). The ADV was recovered from the tissue homogenates of tonsil, lung, spleen and cerebrum in cell culture. The highest virus titer was detected from tonsil between day 6 and day 7 PI. Reddish sublobar consolidation foci were scattered in the apical and cardiac lobes of lung. Although yellowish necrotic foci were detected in tonsil and liver, hemorrhagic lesions were mainly observed in heart, kidney and lymph nodes. Histopathologically, degeneration and necrosis of nerve cells, nonsuppurative meningoe-ncephalitis, nodular gliosis and perivascular cuffings were observed in CNS. Multifocal fibronecrotic foci were observed in lung, liver, lymph nodes and spleen. The major pathologic changes were detected in the midbrain, pons and medulla oblongata. Eosinophilic intranuclear inclusion bodies were mainly observed in epithelia and /or macrophages of tonsil, liver, lung, spleen and submandibular lymph nodes, and neurons of brain, respectively. Observation of viral particles at various stages of replication were possible from the endothelial cells of the alveolar capillaries and tonsillar crypt epithelia by transmission electron microscope.

  • PDF

The Srudy on the Relationship between blood Cyclosporin A level and Gingival Overgrowth in rats (Cyclosporin A 혈중농도와 백서 치은증식과의 관계)

  • Chung, Chan-Gill;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.1
    • /
    • pp.71-86
    • /
    • 1998
  • The purpose of this study was to evaluate clinically and histopathologically the effects to the periodontal tissue in rats after Cyclosporin A (CsA) administration and to determine whether there is a relationship between dosage of CsA or blood CsA level and the seventy of gingival overgrowth in rats. Twenty 6-week-old Sprauge-Dawley Fats were randomized into 4groups. The control group received olive oil only and the test group received daily CsA in olive oil via gastric feeding for 6weeks at a 3,10, and 30mg/kg. Rats were weighed to evaluate the systemic effect of drug and stone models were made from alginate impressions of upper and lover anterior region at 2 week interval. On completion of offal CsA administration, blood were collected and blood CsA levels were quantitated by TDxFLx analyzer. Rats were sacrificed an6 their upper and lower jaws were removed together with the surrounding gingiva and soft tissue for light microscopic examination. The results were as follows : 1. The weight gain of GsA-treated rats was much less than of the control group and central incisors were gradually displaced and separated in the test groups. 2. The extensive fibrovascular proliferation and scattered inflammatoy infiltrates in an edematous stroma were observed in enlarged gingiva of CsA-treated rats. 3. The increase in buccolingual, mesiodistal dimension of the anterior teeth and vertical height of the interdental papilla showed dose-dependent manner in CsA-treated rats. 4. Significant positive correlation exists between blood CsA level and the severity of gingival overgrowth in anterior teeth. This result indicates that the severity of gingival enlargement in CsA treated rats is correlated with dosage of CsA administration and blood CsA level.

  • PDF

Development of Highly Reliable Power and Communication System for Essential Instruments Under Severe Accidents in NPP

  • Choi, Bo Hwan;Jang, Gi Chan;Shin, Sung Min;Lee, Soo Ill;Kang, Hyun Gook;Rim, Chun Taek
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1206-1218
    • /
    • 2016
  • This article proposes a highly reliable power and communication system that guarantees the protection of essential instruments in a nuclear power plant under a severe accident. Both power and communication lines are established with not only conventional wired channels, but also the proposed wireless channels for emergency reserve. An inductive power transfer system is selected due to its robust power transfer characteristics under high temperature, high pressure, and highly humid environments with a large amount of scattered debris after a severe accident. A thermal insulation box and a glass-fiber reinforced plastic box are proposed to protect the essential instruments, including vulnerable electronic circuits, from extremely high temperatures of up to $627^{\circ}C$ and pressure of up to 5 bar. The proposed wireless power and communication system is experimentally verified by an inductive power transfer system prototype having a dipole coil structure and prototype Zigbee modules over a 7-m distance, where both the thermal insulation box and the glass-fiber reinforced plastic box are fabricated and tested using a high-temperature chamber. Moreover, an experiment on the effects of a high radiation environment on various electronic devices is conducted based on the radiation test having a maximum accumulated dose of 27 Mrad.

THE EFFECTS OF IRRADIATION AND CALCIUM-DEFICIENT DIET ON DENTIN AND CEMENTUM FORMATION OF RAT MOLAR (방사선조사와 저칼슘식이가 백서구치의 상아질과 백악질형성에 미치는 영향에 관한 실험적 연구)

  • Shin Jae-Chang;Hwang Eui-Hwan;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.87-109
    • /
    • 1998
  • The present study was designed to elucidate the effects of the Co-60 γ irradiation and/or calcium­deficient diet on the dentin and cementum formation of rat molar. The pregnant three-week old Sprague­Dawley rats were used for the study. The experimental group was divided into two groups, irradiation/normal diet group and irradiation/calcium-deficient diet group. The control group was non­irradiation/normal diet group. The abdomen of the rats at the 19th day of pregnancy were irradiated with single absorbed dose of 350cGy. The rat pups were sacrificed on the 14th day after delivery and the maxillae including molar tooth germ were taken. The specimens including the 1st molar tooth germ were prepared to make tissue sections for light and transmission electron microscopy. Some of tissue sections for light microscopy were stained immunohistochemically with anti-fibronectin antibody. The results were as follows; 1. The Hertwig's epithelial root sheath cells, which are related to the differentiation of the tooth-forming cells, showed irregular cellular arrangement, decrease of intercellular junctional complex, and decreased immunoreactivity to the fibronectin after irradiation. These were more severe in the irradiation/calcium-deficient diet group. 2. The cementoblasts at the cementum-forming area showed chromatin clumpings after irradiation. The immu noreactivity to the fibronectin was weaken after irradiation, especially irradiation/calcium-deficient diet group. 3. The odontoblasts at the dentin-forming area showed increase of lysosomes in the cytoplasm and destruction of intercellular junctional complex. The irradiation/calcium-deficient diet group showed decrease of number and density of the electron dense particles and a large number of vacuoles scattered in the dentin matrix. The immunoreactivity was weaken.

  • PDF

Calibration of HEPD on KOMPSAT-1 Using the KCCH Cyclotron

  • Shin, Young-Hoon;Rhee, Jin-Geun;Min, Kyoung-Wook;Lee, Chun-Sik;Lee, Ju-Hahn;Kwon, Young-Kwan;Kim, Jong-Chan;Ha, Jang-Ho;Park, Se-Hwan;Lee, Chang-Hack;Park, H.S.;Kim, Young-Kyun;Chai, Jong-Seo;Kim, Yu-Seong;Lee, Hye-Young
    • Korean Journal of Remote Sensing
    • /
    • v.15 no.4
    • /
    • pp.289-295
    • /
    • 1999
  • Space Physics Sensor (SPS) on-board the KOMPSAT-1 consists of the High Energy Particle Detector (HEPD) and the Ionospheric Measurement Sensor (IMS). The HEPD is to characterize the low altitude high energy particle environment and the effects on the microelectronics due to these high energy particles. It is composed of four sensors: Proton and Electron Spectrometer(PES), Linear Energy Transfer Spectrometer (LET), Total Dose Monitor (TDM), and Single Event Monitor (SEM). 35 MeV proton beam from the medical KCCH cyclotron, at Korea Cancer Center Hospital in Seoul, is used to calibrate the PES. Primary proton beam of 35MeV scattered by polypropylene target is converted to various energy protons according to the elastic collision kinematics. In this calibration, the threshold level of the proton in the PES can be determined and the energy ranges of PES channels are also calibrated.

A New Radiation-Shielding Device for Restraining Veterinary Patients

  • Songyi Kim;Minju Lee;Miju Oh;Yooyoung Lee;Jiyoung Ban;Jiwoon Park;Sojin Kim;Uhjin Kim;Jaepung Han;Dongwoo Chang
    • Journal of Veterinary Clinics
    • /
    • v.40 no.6
    • /
    • pp.429-437
    • /
    • 2023
  • In veterinary medicine, most radiographic images are obtained by restraining patients, inevitably exposing the restrainer to secondary scattered radiation. Radiation exposure can result in stochastic reactions such as cancer and genetic effects, as well as deterministic reactions such as skin burns, cataracts, and bone marrow suppression. Radiation-shielding equipment, including aprons, thyroid shields, eyewear, and gloves, can reduce radiation exposure. However, the risk of radiation exposure to the upper arms, face, and back remains, and lead aprons and thyroid shields are heavy, restricting movement. We designed a new radiation-shielding system and compared its shielding ability with those of conventional radiation-shielding systems. We hypothesized that the new shielding system would have a wider radiation-shielding range and similar shielding ability. The radiation exposure dose differed significantly between the conventional and new shielding systems in the forehead, chin, and bilateral upper arm areas (p < 0.001). When both systems were used together, the radiation-shielding ability was better than when only one system was used at all anatomical locations (p < 0.01). This study suggests that the new radiation-shielding system is essential and convenient for veterinary radiation workers because it is a step closer to radiation safety in veterinary radiography.

The Analysis of Dose in a Rectum by Multipurpose Brachytherapy Phantom (근접방사선치료용 다목적 팬톰을 이용한 직장 내 선량분석)

  • Huh, Hyun-Do;Kim, Seong-Hoon;Cho, Sam-Ju;Lee, Suk;Shin, Dong-Oh;Kwon, Soo-Il;Kim, Hun-Jung;Kim, Woo-Chul;K. Loh John-J.
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.223-229
    • /
    • 2005
  • Purpose: In this work we designed and made MPBP(Multi Purpose Brachytherapy Phantom). The MPBP enables one to reproduce the same patient set-up in MPBP as the treatment of the patient and we tried to get an exact analysis of rectal doses in the phantom without need of in-vivo dosimetry. Materials and Methods: Dose measurements were tried at a point of rectum 1, the reference point of rectum, with a diode detector for 4 patients treated with tandem and ovoid for a brachytherapy of a cervix cancer. Total 20 times of rectal dose measurements were made with 5 times a patient. The set-up variation of the diode detector was analyzed. The same patient set-ups were reproduced in self-made MPBP and then rectal doses were measured with TLD. Results: The measurement results of the diode detector showed that the set-up variation of the diode detector was the maximum $11.25{\pm}0.95mm$ in the y-direction for Patient 1 and the maximum $9.90{\pm}4.50mm,\;20.85{\pm}4.50mm,\;and\;19.15{\pm}3.33mm$ in the z-direction for Patient 2, 3, and 4, respectively. Un analyzing the degree of variation in 3 directions the more variation was showed in the z-direction than x- and y-direction except Patient 1. The results of TLD measurements in MPBP showed the relative maximum error of 8.6% and 7.7% at a point of rectum 1 for Patient 1 and 4, respectively and 1.7% and 1.2% for Patient 2 and 3, respectively. The doses measured at R1 and R2 were higher than those calculated except R point of Patient 2. this can be thought to related to the algorithm of dose calculation, whcih corrects for air and water but is guessed not to consider the correction for the scattered rays, but by considering the self-error (${\pm}5%$) TLD has the relative error of values measured and calculated was analyzed to be in a good agreement within 15%. Conclusion: The reproducibility of dose measurements under the same condition as the treatment could be achieved owing to the self-made MPMP and the dose at the point of interest could be analyzed accurately. If a treatment is peformed after achieving dose optimization using the data obtained in the phantom, dose will be able to be minimized to important organs.