Acknowledgement
Supported by : National Research Foundation of Korea (NRF)
References
- American Association of Physicists in Medicine (AAPM), Medical physics: the management of imaging dose during image-guided radiotherapy: report Task Group 75, AAPM Task Group 75, Med. Phys. 34 (2007) 4041. https://doi.org/10.1118/1.2775667
- L.K. Wagner, P.J. Eifel, R.A. Geise, Potential biological effects following high X-ray dose interventional procedures, J. Vasc. Interv. Radiol. 5 (1994) 71-81. https://doi.org/10.1016/S1051-0443(94)71456-1
- E.J. Hall, C.S. Wuu, Radiation-induced second cancers: the impact of 3D-CRT and IMRT, Int. J. Radiat. Oncol. Biol. Phys. 56 (2003) 83-88. https://doi.org/10.1016/S0360-3016(03)00073-7
-
A.D. Lazarine, Medical Physics Calculations with MCNP:
$^{TM}$ a Primer, Master of Science Thesis, Texas A&M University, College Station, TX, 2006. - C.R. Harrell, I.G. Zubal, Effect of Variance Reduction Techniques on Monte Carlo Simulated Energy Spectra. Bioengineering Conference, Proceedings of the 1991 IEEE Seventeenth Annual Northeast (Hartford, Connecticut), IEEE, New York, NY, 1991, pp. 97-98.
- D. Sarrut, L.L. Gulgues, Region-oriented CT image representation for reducing computing time of Monte Carlo simulations, Med. Phys. 35 (2008) 1452-1463. https://doi.org/10.1118/1.2884854
- D.E. Peplow, K. Verghese, Digital mammography image simulation using Monte Carlo, Med. Phys. 27 (2000) 568-579. https://doi.org/10.1118/1.598896
- J. Allison, K. Amako, J. Apostolakis, H. Araujo, P. Arce Dubois, M. Asai, G. Barrand, R. Capra, S. Chauvie, R. Chytracek, G.A.P. Cirrone, G.D. Cooperman, G. Cosmo, G. Cuttone, G.G. Daquino, M. Donszelmann, M. Dressel, G. Folger, F. Foppiano, J. Generowicz, V. Grichine, S. Guatelli, P. Gumplinger, A. Heikkinen, I. Hrivnacova, A. Howard, S. Incerti, V. Ivanchenko, T. Johnson, F. Jones, T. Koi, R. Kokoulin, M. Kossov, H. Kurashige, V. Lara, S. Larsson, F. Lei, O. Link, F. Longo, M. Maire, A. Mantero, B. Mascialino, I. McLaren, P. Mendez Lorenzo, K. Minamimoto, K. Murakami, P. Nieminen, L. Pandola, S. Parlati, L. Peralta, J. Perl, A. Pfeiffer, M.G. Pia, A. Ribon, P. Rodrigues, G. Russo, S. Sadilov, G. Santin, T. Sasaki, D. Smith, N. Starkov, S. Tanaka, E. Tcherniaev, B. Tome, A. Trindade, P. Truscott, L. Urban, M. Verderi, A. Walkden, J.P. Wellisch, D.C. Williams, D. Wright, H. Yoshida, Geant4 developments and applications, IEEE Trans. Nucl. Sci. 53 (2006) 270-278. https://doi.org/10.1109/TNS.2006.869826
- A.M. Wysocka-Rabin, S. Qamhiyeh, O. Jakel, Simulation of computed tomography (CT) images using a Monte Carlo approach, Nukleonika 56 (2011) 299-304.
- J.K. Shultis, R.E. Faw, Radiation Shielding, Chapter 11, American Nuclear Society, Inc., La Grange Park, IL, 2000, pp. 415-420.
- J.K. Shultis, R.E. Faw, Radiation Shielding, Chapter 11, American Nuclear Society, Inc., La Grange Park, IL, 2000, pp. 420-426.
- X-5 Monte Carlo Team, MCNP-A General Monte Carlo N-particle Transport Code, Version 5, Los Alamos National Laboratory, Los Alamos, NM, 2003.
- K. Cranley, B.J. Gilmore, G.W.A. Fogarty, L. Deponds, Catalogue of Diagnostic X-ray Spectra and Other Data (IPEM Report 78), Institute of Physics and Engineering in Medicine, York, UK, 1997.
- N. Keat, D. Platten, M. Lewis, S. Edyvean, ImPACT Scan Report 05071: Siemens Somatom Sensation Open CT Scanner Technical Evaluation. Imaging Performance Assessment of CT Scanners, Center for Evidence-based Purchasing, London, England, 2005.
-
Phantom Laboratory Inc, Catphan
$^{(R)}$ 500 and 600 Manual, Phantom Laboratory, Inc., New York, NY, 2010. - C. Lee, C. Lee, S.H. Park, J.K. Lee, Development of the two Korean adult tomographic computational phantoms for organ dosimetry, Med. Phys. 33 (2006) 380-390. https://doi.org/10.1118/1.2161405
Cited by
- Monte Carlo-Based Finite Element Method for the Study of Randomly Distributed Vacancy Defects in Graphene Sheets vol.2018, pp.None, 2015, https://doi.org/10.1155/2018/3037063
- Buckling Analysis of Vacancy-Defected Graphene Sheets by the Stochastic Finite Element Method vol.11, pp.9, 2015, https://doi.org/10.3390/ma11091545